Files
agent-radar 2ed3415fb7
Publish Claude Code Binaries / Stage and publish binaries (push) Canceled after 0s
Publish Tutti App Runtime / Build darwin-arm64 (push) Canceled after 0s
Publish Tutti App Runtime / Build darwin-amd64 (push) Canceled after 0s
Publish Tutti App Runtime / Build linux-amd64 (push) Canceled after 0s
Publish Tutti App Runtime / Build windows-amd64 (push) Canceled after 0s
Sync Tutti Agent Skills / sync (push) Canceled after 0s
Windows Agent Adapters / Test Windows agent adapters (push) Canceled after 0s
Windows Daemon Adapters / Test Windows daemon adapters (push) Canceled after 0s
Publish Tutti App Runtime / Publish runtime catalog (push) Canceled after 0s
源码快照 @ 2026-09-01 (source-only, 剔除非源码素材)
2026-09-01 20:17:27 +08:00

68 lines
2.4 KiB
Go

package agentstatus
import (
"context"
)
func (s Service) Probe(ctx context.Context, input ProbeInput) (ProbeResult, error) {
now := s.now()
specs, err := s.selectProviderSpecs(ctx, []string{input.Provider}, true)
if err != nil {
return ProbeResult{}, err
}
spec := specs[0]
if result, ok := unsupportedProviderProbeResult(spec, now); ok {
return result, nil
}
runtimeResolution := s.resolveProviderRuntime(ctx, spec)
status := s.statusForSpec(ctx, spec, now, statusDetectionOptions{
forceRefresh: true,
skipAdapterProbe: true,
})
result := ProbeResult{
Provider: spec.Provider,
CheckedAt: now,
BinaryPath: status.Adapter.BinaryPath,
Command: cloneStrings(runtimeResolution.AdapterCommand),
Checks: cloneProviderChecks(status.Checks),
LastError: cloneProviderLastError(status.LastError),
}
if !status.CLI.Installed {
result.Status = ProbeFailed
result.ReasonCode = "cli_not_found"
result.Message = "CLI binary not found"
return result, nil
}
if !status.Adapter.Installed {
if status.Availability.ReasonCode == "acp_adapter_launch_failed" {
return s.probeAdapterRuntimeCommand(ctx, spec, runtimeResolution, now), nil
}
result.Status = ProbeFailed
result.ReasonCode = firstNonBlank(status.Availability.ReasonCode, "acp_adapter_not_found")
result.Message = agentProviderProbeAdapterUnavailableMessage(result.ReasonCode)
return result, nil
}
// Codex availability is established by its formal app-server handshake. Do
// not let a preliminary structural diagnostic (or a version floor) return
// before we collect that primary runtime evidence.
if isCodexStatusSpec(spec) {
probed := s.probeAdapterRuntimeCommand(ctx, spec, runtimeResolution, now)
assessment := s.assessCodexRuntime(spec, runtimeResolution.CLIPath, probed, true, false)
if probed.Status == ProbeFailed && assessment.RepairPlan.Allowed {
probed.ReasonCode = assessment.RepairPlan.ReasonCode
probed.LastError = &ProviderLastError{Code: string(CodexErrPlatformPkgIncomplete), Message: probed.Message}
}
return probed, nil
}
if !providerCLIVersionMeetsMinimum(spec, status.CLI.Version) {
result.Status = ProbeFailed
result.ReasonCode = providerCLIVersionUnsupportedReasonCode(spec)
result.Message = "CLI version is below " + spec.MinVersion
return result, nil
}
probed := s.probeAdapterRuntimeCommand(ctx, spec, runtimeResolution, now)
probed.Checks = cloneProviderChecks(status.Checks)
return probed, nil
}