Files
沃巴蒂 ff22ed3a8b feat(deepdata): 引入修改密码、文件预览组件与清洗算子增强,deepflow 改名为 deep-flow
本次同步 09-12 至 09-28 的代码变更,主要内容:

新增功能
- 修改密码:后端新增 ChangePasswordRequest DTO 与UserController/UserService
  对应接口,前端新增 ChangePasswordDialog 并在 Header 接入入口
- 文件预览组件重构:file-preview 目录拆分出 VideoPreview(支持 blobUrl 直传)、
  ImagePreview、AudioPreview,index.tsx 统一调度各类型预览器
- 新增 my_ops 算子模块:markitdown_parser、mineru_pdf_parser、text_quality_evaluator
- 新增 tools/minio-file-server MinIO 文件服务

功能增强
- 数据清洗:cleaning_task_service/scheduler/routes 重构,
  data_juicer_executor 与 wrapper 增强,OperatorTable/LogsTable/TaskDetail 同步调整
- 数据标注:annotation sync.py、project.py 接口与schema 更新
- 数据采集、算子市场、首页与菜单路由相关页面调整
- DataJuicer 算子接入(useOperatorOperations、dj_ops_schema)

结构调整
- deepflow/ 更名为 deep-flow/(419 个文件重命名)
- 新增 helm 部署编排、GitHub Actions 之外的自建镜像构建脚本

未纳入本次提交
- scripts-backup/、runtime/python-executor-backup/、components_backup/(备份目录)
- *.backup*、__pycache__ 产物
- zh_core_web_sm-3.8.0-py3-none-any.whl(46MB 构建产物)
- DataX/(内嵌独立仓库,远程亦未收录其源码)
2026-10-03 22:44:56 +08:00

8413 lines
1.2 MiB
Plaintext
Raw Permalink Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
## Sheet1
| Item | Description |
| --- | --- |
| 001001A | Demolition of walls, slabs, kerbs, channels, catchwater base slabs, and the like up to 150 mm thick. Lime Concrete |
| 001001B | Demolition of walls, slabs, kerbs, channels, catchwater base slabs, and the like up to 150 mm thick. Cement Concrete |
| 001001C | Demolition of walls, slabs, kerbs, channels, catchwater base slabs, and the like up to 150 mm thick. Rein-forced Concrete |
| 001001D | Demolition of walls, slabs, kerbs, channels, catchwater base slabs, and the like up to 150 mm thick. Masonry, stonework and the like |
| 001002A | As for Item No. 001/001 but exceeding 150 mm thickness and also in columns and beams etc. Lime Concrete |
| 001002B | As for Item No. 001/001 but exceeding 150 mm thickness and also in columns and beams etc. Cement Concrete |
| 001002C | As for Item No. 001/001 but exceeding 150 mm thickness and also in columns and beams etc. Rein-forced Concrete |
| 001002D | As for Item No. 001/001 but exceeding 150 mm thickness and also in columns and beams etc. Masonry, stonework and the like |
| 001003A | Demolition of thrust blocks, piers etc. Lime Concrete |
| 001003B | Demolition of thrust blocks, piers etc. Cement Concrete |
| 001003C | Demolition of thrust blocks, piers etc. Rein-forced Concrete |
| 001004B | Extra over Item Nos. 001/001 to 001/003 for trimming and squaring face of concrete works. Cement Concrete |
| 001004C | Extra over Item Nos. 001/001 to 001/003 for trimming and squaring face of concrete works. Rein-forced Concrete |
| 001005 | Demolition of chain link fence. |
| 001006 | Demolition of fencing gate. |
| 001007 | General site clearance of the Site. |
| 001008 | Removal of disused sewers, drains or ducts:- 300 mm diameter and under. |
| 001009 | Removal of disused sewers, drains or ducts:- diameter exceeding 300 mm but not exceeding 600 mm. |
| 001010 | Removal of disused sewers, drains or ducts:- diameter exceeding 600 mm but not exceeding 900 mm. |
| 001011 | Removal of disused sewers, drains or ducts:- diameter exceeding 900 mm. |
| 001012 | Reprovisioning of maintenance yard. |
| 001013 | Cut grass and vines on service reservoir roof, storage grounds and station surroundings. |
| 001013a | Cut grass and vines on slopes or walls to a height of 3.5m above ground level or top of catchwater |
| 001013b | Cut grass and vines on slopes or walls to a height over 3.5m above ground level or top of catchwater |
| 001013c | As Item No. 001/014 but on slopes or walls to a vertical distance of 3.5m below ground level or top of catchwater |
| 001013d | As Item No. 001/015 but on slopes or walls to a vertical distance over 3.5m below ground level or top of catchwater |
| 001014 | Remove bushes and undergrowth including removal of roots and stumps. |
| 001014a | Remove bushes and undergrowth, including removal of roots and stumps, on slopes or walls to a height of 3.5m above ground level or top of catchwater |
| 001014b | Remove bushes and undergrowth, including removal of roots and stumps, on slopes or walls to a vertical distance of 3.5m below ground level or top of catchwater |
| 001014c | Remove bushes and undergrowth, including removal of roots and stumps, on slopes or walls to a height over 3.5m above ground level or top of catchwater |
| 001014d | Remove bushes and undergrowth, including removal of roots and stumps, on slopes or walls to a vertical distance over 3.5m below ground level or top of catchwater |
| 001015 | Remove bushes and undergrowth excluding removal of roots and stumps. |
| 001015a | Remove bushes and undergrowth, excluding removal of roots and stumps, on slopes or walls to a height of 3.5m above ground level or top of catchwater. |
| 001015b | Remove bushes and undergrowth, excluding removal of roots and stumps, on slopes or walls to a vertical distance of 3.5m below ground level or top of catchwater. |
| 001015c | Remove bushes and undergrowth, excluding removal of roots and stumps, on slopes or walls to a height over 3.5m above ground level or top of catchwater. |
| 001015d | Remove bushes and undergrowth, excluding removal of roots and stumps, on slopes or walls to a vertical distance over 3.5m below ground level or top of catchwater. |
| 001015e | Felling of trees, diameter at breast height not less than 95 mm but not exceeding 200 mm |
| 001015f | Felling of trees, diameter at breast height exceeding 200 mm but not exceeding 350 mm |
| 001015g | Felling of trees, diameter at breast height exceeding 350 mm but not exceeding 600 mm |
| 001015h | Felling of trees, diameter at breast height exceeding 600 mm but not exceeding 800 mm |
| 001015i | Felling of trees, diameter at breast height exceeding 800 mm but not exceeding 1000 mm |
| 001015j | Remove fallen trees, diameter at breast height not exceeding 350 mm |
| 001015k | Remove fallen trees, diameter at breast height exceeding 350 mm |
| 001015l | Grub out tree stumps, stump diameter at cut point measured not exceeding 600 mm |
| 001015m | Grub out tree stumps, stump diameter at cut point measured exceeding 600 mm |
| 001015n | Clearance of unwanted vegetation. |
| 001016 | Excavate in topsoil layer to a depth of 150 mm. |
| 001017 | Extra over Item No. 001/016 for stockpiling and re-spreading. |
| 001018 | Clear vegetation from chain link fence. |
| 001019 | Form path. |
| 001022 | Sort and deliver hard rocks and broken concrete. |
| 001023 | Sort and dispose of paper and cardboard packaging. |
| 001024 | Carry out sorting of tree/ yard waste, deliver to EPD’s shredding facilities or other yard waste treatment facilities other than landfill sites |
| 002001 | General excavation in all material, other than rock or artificial hard material. |
| 002002 | General excavation in rock or artificial hard material, blasting permitted. |
| 002003 | General excavation in rock or artificial hard material, blasting not permitted. |
| 002005 | Deposit fine fill or suitable material. |
| 002006 | Deposit fine fill or suitable materials behind retaining wall or in trenches. |
| 002007 | Deposit rock fill material above foundation. |
| 003001A | Excavation in trenches - up to 3 m width at original ground level All materials. Trench up to but not exceeding 1.5 m deep |
| 003001B | Excavation in trenches - up to 3 m width at original ground level All materials. That portion of trench exceeding 1.5 m but not exceeding 3 m deep |
| 003001C | Excavation in trenches - up to 3 m width at original ground level All materials. That portion of trench exceeding 3 m but not exceeding 4.5 m deep |
| 003001D | Excavation in trenches - up to 3 m width at original ground level All materials. That portion of trench exceeding 4.5 m deep |
| 003002A | Excavation in trenches - up to 3 m width at original ground level Extra over Item Nos. 003/001, 020/001 to 020/158, 020/182, 150/001 to 150/008, 181/001 to 181/034 for rock, blasting permitted. Trench up to but not exceeding 1.5 m deep |
| 003002B | Excavation in trenches - up to 3 m width at original ground level Extra over Item Nos. 003/001, 020/001 to 020/158, 020/182, 150/001 to 150/008, 181/001 to 181/034 for rock, blasting permitted. That portion of trench exceeding 1.5 m but not exceeding 3 m deep |
| 003002C | Excavation in trenches - up to 3 m width at original ground level Extra over Item Nos. 003/001, 020/001 to 020/158, 020/182, 150/001 to 150/008, 181/001 to 181/034 for rock, blasting permitted. That portion of trench exceeding 3 m but not exceeding 4.5 m deep |
| 003002D | Excavation in trenches - up to 3 m width at original ground level Extra over Item Nos. 003/001, 020/001 to 020/158, 020/182, 150/001 to 150/008, 181/001 to 181/034 for rock, blasting permitted. That portion of trench exceeding 4.5 m deep |
| 003003A | Excavation in trenches - up to 3 m width at original ground level Extra over Item Nos. 003/001, 020/001 to 020/158, 020/182, 150/001 to 150/008, 181/001 to 181/034 for rock, but blasting not permitted. Trench up to but not exceeding 1.5 m deep |
| 003003B | Excavation in trenches - up to 3 m width at original ground level Extra over Item Nos. 003/001, 020/001 to 020/158, 020/182, 150/001 to 150/008, 181/001 to 181/034 for rock, but blasting not permitted. That portion of trench exceeding 1.5 m but not exceeding 3 m deep |
| 003003C | Excavation in trenches - up to 3 m width at original ground level Extra over Item Nos. 003/001, 020/001 to 020/158, 020/182, 150/001 to 150/008, 181/001 to 181/034 for rock, but blasting not permitted. That portion of trench exceeding 3 m but not exceeding 4.5 m deep |
| 003003D | Excavation in trenches - up to 3 m width at original ground level Extra over Item Nos. 003/001, 020/001 to 020/158, 020/182, 150/001 to 150/008, 181/001 to 181/034 for rock, but blasting not permitted. That portion of trench exceeding 4.5 m deep |
| 003004A | Excavation in trenches - up to 3 m width at original ground level Extra over Item Nos. 003/001, 020/001 to 020/158, 020/182, 150/001 to 150/008, 181/001 to 181/034 for artificial hard material, blasting permitted. Trench up to but not exceeding 1.5 m deep |
| 003004B | Excavation in trenches - up to 3 m width at original ground level Extra over Item Nos. 003/001, 020/001 to 020/158, 020/182, 150/001 to 150/008, 181/001 to 181/034 for artificial hard material, blasting permitted. That portion of trench exceeding 1.5 m but not exceeding 3 m deep |
| 003004C | Excavation in trenches - up to 3 m width at original ground level Extra over Item Nos. 003/001, 020/001 to 020/158, 020/182, 150/001 to 150/008, 181/001 to 181/034 for artificial hard material, blasting permitted. That portion of trench exceeding 3 m but not exceeding 4.5 m deep |
| 003004D | Excavation in trenches - up to 3 m width at original ground level Extra over Item Nos. 003/001, 020/001 to 020/158, 020/182, 150/001 to 150/008, 181/001 to 181/034 for artificial hard material, blasting permitted. That portion of trench exceeding 4.5 m deep |
| 003005A | Excavation in trenches - up to 3 m width at original ground level Extra over Item Nos. 003/001, 020/001 to 020/158, 020/182, 150/001 to 150/008, 181/001 to 181/034 for artificial hard material, but blasting not permitted. Trench up to but not exceeding 1.5 m deep |
| 003005B | Excavation in trenches - up to 3 m width at original ground level Extra over Item Nos. 003/001, 020/001 to 020/158, 020/182, 150/001 to 150/008, 181/001 to 181/034 for artificial hard material, but blasting not permitted. That portion of trench exceeding 1.5 m but not exceeding 3 m deep |
| 003005C | Excavation in trenches - up to 3 m width at original ground level Extra over Item Nos. 003/001, 020/001 to 020/158, 020/182, 150/001 to 150/008, 181/001 to 181/034 for artificial hard material, but blasting not permitted. That portion of trench exceeding 3 m but not exceeding 4.5 m deep |
| 003005D | Excavation in trenches - up to 3 m width at original ground level Extra over Item Nos. 003/001, 020/001 to 020/158, 020/182, 150/001 to 150/008, 181/001 to 181/034 for artificial hard material, but blasting not permitted. That portion of trench exceeding 4.5 m deep |
| 004001A | Excavation in wells and trial holes - up to 3 m width at original ground level All materials. Well or trial hole, depth not exceeding 1.5 m deep |
| 004001B | Excavation in wells and trial holes - up to 3 m width at original ground level All materials. That portion of well or trial hole exceeding 1.5 m but not exceeding 3 m deep |
| 004001C | Excavation in wells and trial holes - up to 3 m width at original ground level All materials. That portion of well or trial hole exceeding 3 m but not exceeding 4.5 m deep |
| 004001D | Excavation in wells and trial holes - up to 3 m width at original ground level All materials. That portion of well or trial hole exceeding 4.5 m deep |
| 004002A | Excavation in wells and trial holes - up to 3 m width at original ground level Extra over Item No. 004/001 for rock, blasting permitted. Well or trial hole, depth not exceeding 1.5 m |
| 004002B | Excavation in wells and trial holes - up to 3 m width at original ground level Extra over Item No. 004/001 for rock, blasting permitted. That portion of well or trial hole exceeding 1.5 m but not exceeding 3 m deep |
| 004002C | Excavation in wells and trial holes - up to 3 m width at original ground level Extra over Item No. 004/001 for rock, blasting permitted. That portion of well or trial hole exceeding 3 m but not exceeding 4.5 m deep |
| 004002D | Excavation in wells and trial holes - up to 3 m width at original ground level Extra over Item No. 004/001 for rock, blasting permitted. That portion of well or trial hole exceeding 4.5 m deep |
| 004003A | Excavation in wells and trial holes - up to 3 m width at original ground level Extra over Item No. 004/001 for rock, but blasting not permitted. Well or trial hole, depth not exceeding 1.5 m deep |
| 004003B | Excavation in wells and trial holes - up to 3 m width at original ground level Extra over Item No. 004/001 for rock, but blasting not permitted. That portion of well or trial hole exceeding 1.5 m but not exceeding 3 m deep |
| 004003C | Excavation in wells and trial holes - up to 3 m width at original ground level Extra over Item No. 004/001 for rock, but blasting not permitted. That portion of well or trial hole exceeding 3 m but not exceeding 4.5 m deep |
| 004003D | Excavation in wells and trial holes - up to 3 m width at original ground level Extra over Item No. 004/001 for rock, but blasting not permitted. That portion of well or trial hole exceeding 4.5 m deep |
| 004004A | Excavation in wells and trial holes - up to 3 m width at original ground level Extra over Item No. 004/001 for artificial hard material, blasting permitted. Well or trial hole, depth not exceeding 1.5 m deep |
| 004004B | Excavation in wells and trial holes - up to 3 m width at original ground level Extra over Item No. 004/001 for artificial hard material, blasting permitted. That portion of well or trial hole exceeding 1.5 m but not exceeding 3 m deep |
| 004004C | Excavation in wells and trial holes - up to 3 m width at original ground level Extra over Item No. 004/001 for artificial hard material, blasting permitted. That portion of well or trial hole exceeding 3 m but not exceeding 4.5 m deep |
| 004004D | Excavation in wells and trial holes - up to 3 m width at original ground level Extra over Item No. 004/001 for artificial hard material, blasting permitted. That portion of well or trial hole exceeding 4.5 m deep |
| 004005A | Excavation in wells and trial holes - up to 3 m width at original ground level Extra over Item No. 004/001 for artificial hard material, but blasting not permitted. Well or trial hole, depth not exceeding 1.5 m deep |
| 004005B | Excavation in wells and trial holes - up to 3 m width at original ground level Extra over Item No. 004/001 for artificial hard material, but blasting not permitted. That portion of well or trial hole exceeding 1.5 m but not exceeding 3 m deep |
| 004005C | Excavation in wells and trial holes - up to 3 m width at original ground level Extra over Item No. 004/001 for artificial hard material, but blasting not permitted. That portion of well or trial hole exceeding 3 m but not exceeding 4.5 m deep |
| 004005D | Excavation in wells and trial holes - up to 3 m width at original ground level Extra over Item No. 004/001 for artificial hard material, but blasting not permitted. That portion of well or trial hole exceeding 4.5 m deep |
| 005001 | Excavation in headings and tunnels Excavation in all materials except rock. |
| 005002 | Excavation in headings and tunnels Excavation in rock requiring support, blasting permitted. |
| 005003 | Excavation in headings and tunnels Excavation in rock requiring support, but blasting not permitted. |
| 005004 | Excavation in headings and tunnels Excavation in rock not requiring support, blasting permitted. |
| 005005 | Excavation in headings and tunnels Excavation in rock not requiring support, but blasting not permitted. |
| 006001 | Excavation in bituminous materials and lean concrete. |
| 006002 | Excavation in plain concrete, reinforced concrete and hardcore. |
| 006003 | Sawing of road surface for flexible pavement Width not exceeding 6 mm; depth not exceeding 50 mm. |
| 006004 | Sawing of road surface for concrete slab Width not exceeding 5 mm; depth not exceeding 30 mm. |
| 006005 | Sawing of road surface for concrete slab Width not exceeding 5 mm; depth exceeding 30 mm but not exceeding 80 mm. |
| 006006 | Sawing of road surface for concrete slab Width exceeding 5 mm but not exceeding 10 mm; depth not exceeding 50 mm. |
| 006007 | Sawing of road surface for concrete slab Width exceeding 5 mm but not exceeding 10 mm; depth exceeding 50 mm but not exceeding 75 mm. |
| 009001 | General fill material provided by the Contractor. |
| 009002 | Stabilised fill provided by the Contractor. |
| 009003 | Topsoil provided by the Contractor. |
| 009004 | Sand in trench provided by the Contractor. |
| 009005 | 5 mm - 20 mm aggregate as general fill material provided by the Contractor. |
| 009006 | 300mm hardcores provided by the Contractor. |
| 009007 | Rock fill material above foundation provided by the Contractor. |
| 009008 | Rock fill material grade 200 provided by the Contractor. |
| 009009 | Rock fill material grade 400 provided by the Contractor. |
| 009010 | Rock fill material grade 700 provided by the Contractor. |
| 009011 | Rock armour Type 1 provided by the Contractor. |
| 009012 | Rock armour Type 2 provided by the Contractor. |
| 009013 | 5 mm - 20 mm aggregate in trench for bedding and surround to pipes provided by the Contractor. |
| 009014 | Graded filter behind retaining walls provided by the Contractor. |
| 009015 | Compaction of fill material Spread and level general, stabilised, fine, special or granular filling material and carry out "method" type compaction as specified in PS Clause 6.03. |
| 009016 | Compaction of fill material As Item No. 009/015, but compact to obtain a relative compaction as specified in GS Clauses 6.48, 6.49 and 6.54. |
| 009017 | Compaction of fill material Spread and level granular, stabilised, fine, special or granular filling materials behind walls or in trenches and carry out "method" type compaction as specified in PS Clause 6.03. |
| 009018 | Compaction of fill material As Item No. 009/017, but compact to obtain a relative compaction as specified in GS Clauses 6.48, 6.49 and 6.54. |
| 009019 | Compaction of fill material Compaction of rock fill material above foundation. |
| 020001A | Cast Iron/ Ductile Iron Pipe exposed or suspended in chamber. Nominal diameter of pipe 80 mm & under |
| 020001B | Cast Iron/ Ductile Iron Pipe exposed or suspended in chamber. Nominal diameter of pipe 100 mm |
| 020001C | Cast Iron/ Ductile Iron Pipe exposed or suspended in chamber. Nominal diameter of pipe 125 -150 mm |
| 020001D | Cast Iron/ Ductile Iron Pipe exposed or suspended in chamber. Nominal diameter of pipe 200 mm |
| 020001E | Cast Iron/ Ductile Iron Pipe exposed or suspended in chamber. Nominal diameter of pipe 250 mm |
| 020001F | Cast Iron/ Ductile Iron Pipe exposed or suspended in chamber. Nominal diameter of pipe 300 - 350 mm |
| 020001G | Cast Iron/ Ductile Iron Pipe exposed or suspended in chamber. Nominal diameter of pipe 400 mm |
| 020001H | Cast Iron/ Ductile Iron Pipe exposed or suspended in chamber. Nominal diameter of pipe 450 - 525mm |
| 020001I | Cast Iron/ Ductile Iron Pipe exposed or suspended in chamber. Nominal diameter of pipe 600 - 675mm |
| 020001J | Cast Iron/ Ductile Iron Pipe exposed or suspended in chamber. Nominal diameter of pipe 700 - 750 mm |
| 020001K | Cast Iron/ Ductile Iron Pipe exposed or suspended in chamber. Nominal diameter of pipe 800 mm |
| 020001L | Cast Iron/ Ductile Iron Pipe exposed or suspended in chamber. Nominal diameter of pipe 900 mm |
| 020001M | Cast Iron/ Ductile Iron Pipe exposed or suspended in chamber. Nominal diameter of pipe 1000 - 1100mm |
| 020001N | Cast Iron/ Ductile Iron Pipe exposed or suspended in chamber. Nominal diameter of pipe 1200 mm |
| 020001O | Cast Iron/ Ductile Iron Pipe exposed or suspended in chamber. Nominal diameter of pipe 1350 - 1400mm |
| 020002A | Bitumen lined steel pipe exposed or suspended in chamber. Nominal diameter of pipe 80 mm & under |
| 020002B | Bitumen lined steel pipe exposed or suspended in chamber. Nominal diameter of pipe 100 mm |
| 020002C | Bitumen lined steel pipe exposed or suspended in chamber. Nominal diameter of pipe 125 -150 mm |
| 020002D | Bitumen lined steel pipe exposed or suspended in chamber. Nominal diameter of pipe 200 mm |
| 020002E | Bitumen lined steel pipe exposed or suspended in chamber. Nominal diameter of pipe 250 mm |
| 020002F | Bitumen lined steel pipe exposed or suspended in chamber. Nominal diameter of pipe 300 - 350 mm |
| 020002G | Bitumen lined steel pipe exposed or suspended in chamber. Nominal diameter of pipe 400 mm |
| 020002H | Bitumen lined steel pipe exposed or suspended in chamber. Nominal diameter of pipe 450 - 525mm |
| 020002I | Bitumen lined steel pipe exposed or suspended in chamber. Nominal diameter of pipe 600 - 675mm |
| 020002J | Bitumen lined steel pipe exposed or suspended in chamber. Nominal diameter of pipe 700 - 750 mm |
| 020002K | Bitumen lined steel pipe exposed or suspended in chamber. Nominal diameter of pipe 800 mm |
| 020002L | Bitumen lined steel pipe exposed or suspended in chamber. Nominal diameter of pipe 900 mm |
| 020002M | Bitumen lined steel pipe exposed or suspended in chamber. Nominal diameter of pipe 1000 - 1100mm |
| 020002N | Bitumen lined steel pipe exposed or suspended in chamber. Nominal diameter of pipe 1200 mm |
| 020002O | Bitumen lined steel pipe exposed or suspended in chamber. Nominal diameter of pipe 1350 - 1400mm |
| 020002P | Bitumen lined steel pipe exposed or suspended in chamber. Nominal diameter of pipe 1600 mm |
| 020002Q | Bitumen lined steel pipe exposed or suspended in chamber. Nominal diameter of pipe 1800 mm |
| 020002R | Bitumen lined steel pipe exposed or suspended in chamber. Nominal diameter of pipe 1950 - 2100 mm |
| 020002S | Bitumen lined steel pipe exposed or suspended in chamber. Nominal diameter of pipe >2100 mm |
| 020003B | Concrete lined/Epoxy coated steel pipe exposed or suspended in chamber. Nominal diameter of pipe 100 mm |
| 020003C | Concrete lined/Epoxy coated steel pipe exposed or suspended in chamber. Nominal diameter of pipe 125 -150 mm |
| 020003D | Concrete lined/Epoxy coated steel pipe exposed or suspended in chamber. Nominal diameter of pipe 200 mm |
| 020003E | Concrete lined/Epoxy coated steel pipe exposed or suspended in chamber. Nominal diameter of pipe 250 mm |
| 020003F | Concrete lined/Epoxy coated steel pipe exposed or suspended in chamber. Nominal diameter of pipe 300 - 350 mm |
| 020003G | Concrete lined/Epoxy coated steel pipe exposed or suspended in chamber. Nominal diameter of pipe 400 mm |
| 020003H | Concrete lined/Epoxy coated steel pipe exposed or suspended in chamber. Nominal diameter of pipe 450 - 525mm |
| 020003I | Concrete lined/Epoxy coated steel pipe exposed or suspended in chamber. Nominal diameter of pipe 600 - 675mm |
| 020003J | Concrete lined/Epoxy coated steel pipe exposed or suspended in chamber. Nominal diameter of pipe 700 - 750 mm |
| 020003K | Concrete lined/Epoxy coated steel pipe exposed or suspended in chamber. Nominal diameter of pipe 800 mm |
| 020003L | Concrete lined/Epoxy coated steel pipe exposed or suspended in chamber. Nominal diameter of pipe 900 mm |
| 020003M | Concrete lined/Epoxy coated steel pipe exposed or suspended in chamber. Nominal diameter of pipe 1000 - 1100mm |
| 020003N | Concrete lined/Epoxy coated steel pipe exposed or suspended in chamber. Nominal diameter of pipe 1200 mm |
| 020003O | Concrete lined/Epoxy coated steel pipe exposed or suspended in chamber. Nominal diameter of pipe 1350 - 1400mm |
| 020003P | Concrete lined/Epoxy coated steel pipe exposed or suspended in chamber. Nominal diameter of pipe 1600 mm |
| 020003Q | Concrete lined/Epoxy coated steel pipe exposed or suspended in chamber. Nominal diameter of pipe 1800 mm |
| 020003R | Concrete lined/Epoxy coated steel pipe exposed or suspended in chamber. Nominal diameter of pipe 1950 - 2100 mm |
| 020004A | UPVC/ Black PE pipe exposed or suspended in chamber. Nominal diameter of pipe 15 mm |
| 020004B | UPVC/ Black PE pipe exposed or suspended in chamber. Nominal diameter of pipe 20 mm |
| 020004C | UPVC/ Black PE pipe exposed or suspended in chamber. Nominal diameter of pipe 25 mm |
| 020004D | UPVC/ Black PE pipe exposed or suspended in chamber. Nominal diameter of pipe 40 mm |
| 020004E | UPVC/ Black PE pipe exposed or suspended in chamber. Nominal diameter of pipe 50 mm |
| 020004F | UPVC/ Black PE pipe exposed or suspended in chamber. Nominal diameter of pipe 80 mm |
| 020004G | UPVC/ Black PE pipe exposed or suspended in chamber. Nominal diameter of pipe 100 mm |
| 020004H | UPVC/ Black PE pipe exposed or suspended in chamber. Nominal diameter of pipe 150 mm |
| 020004I | UPVC/ Black PE pipe exposed or suspended in chamber. Nominal diameter of pipe 200 mm |
| 020004J | UPVC/ Black PE pipe exposed or suspended in chamber. Nominal diameter of pipe 250 mm |
| 020005A | Lined G.I. pipe exposed or suspended in chamber. Nominal diameter of pipe 15 mm |
| 020005B | Lined G.I. pipe exposed or suspended in chamber. Nominal diameter of pipe 20 mm |
| 020005C | Lined G.I. pipe exposed or suspended in chamber. Nominal diameter of pipe 25 mm |
| 020005D | Lined G.I. pipe exposed or suspended in chamber. Nominal diameter of pipe 40 mm |
| 020005E | Lined G.I. pipe exposed or suspended in chamber. Nominal diameter of pipe 50 mm |
| 020005F | Lined G.I. pipe exposed or suspended in chamber. Nominal diameter of pipe 80 mm |
| 020005G | Lined G.I. pipe exposed or suspended in chamber. Nominal diameter of pipe 100 mm |
| 020005H | Lined G.I. pipe exposed or suspended in chamber. Nominal diameter of pipe 150 mm |
| 020006A | Stainless steel pipe exposed or suspended in chamber. Nominal diameter of pipe 15 mm |
| 020006B | Stainless steel pipe exposed or suspended in chamber. Nominal diameter of pipe 20 mm |
| 020006C | Stainless steel pipe exposed or suspended in chamber. Nominal diameter of pipe 25 mm |
| 020006D | Stainless steel pipe exposed or suspended in chamber. Nominal diameter of pipe 40 mm |
| 020006E | Stainless steel pipe exposed or suspended in chamber. Nominal diameter of pipe 50 mm |
| 020006F | Stainless steel pipe exposed or suspended in chamber. Nominal diameter of pipe 80 mm |
| 020006G | Stainless steel pipe exposed or suspended in chamber. Nominal diameter of pipe 100 mm |
| 020006H | Stainless steel pipe exposed or suspended in chamber. Nominal diameter of pipe 150 mm |
| 020006I | Stainless steel pipe exposed or suspended in chamber. Nominal diameter of pipe 200 mm |
| 020006aA | Corrugated stainless steel tube exposed or suspended in chamber. Nominal diameter of pipe 15 mm |
| 020006aB | Corrugated stainless steel tube exposed or suspended in chamber. Nominal diameter of pipe 20 mm |
| 020006aC | Corrugated stainless steel tube exposed or suspended in chamber. Nominal diameter of pipe 25 mm |
| 020006aD | Corrugated stainless steel tube exposed or suspended in chamber. Nominal diameter of pipe 40 mm |
| 020006aE | Corrugated stainless steel tube exposed or suspended in chamber. Nominal diameter of pipe 50 mm |
| 020006aF | Corrugated stainless steel tube exposed or suspended in chamber. Nominal diameter of pipe 80 mm |
| 020006aG | Corrugated stainless steel tube exposed or suspended in chamber. Nominal diameter of pipe 100 mm |
| 020006aH | Corrugated stainless steel tube exposed or suspended in chamber. Nominal diameter of pipe 150 mm |
| 020006aI | Corrugated stainless steel tube exposed or suspended in chamber. Nominal diameter of pipe 200 mm |
| 020007A | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 80 mm & under |
| 020007B | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 100 mm |
| 020007C | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 125 -150 mm |
| 020007D | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 200 mm |
| 020007E | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 250 mm |
| 020007F | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 300 - 350 mm |
| 020007G | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 400 mm |
| 020007H | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 450 - 525mm |
| 020007I | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 600 - 675mm |
| 020007J | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 700 - 750 mm |
| 020007K | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 800 mm |
| 020007L | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 900 mm |
| 020007M | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 1000 - 1100mm |
| 020007N | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 1200 mm |
| 020007O | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 1350 - 1400mm |
| 020008A | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 80 mm & under |
| 020008B | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 100 mm |
| 020008C | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 125 -150 mm |
| 020008D | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 200 mm |
| 020008E | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 250 mm |
| 020008F | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 300 - 350 mm |
| 020008G | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 400 mm |
| 020008H | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 450 - 525mm |
| 020008I | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 600 - 675mm |
| 020008J | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 700 - 750 mm |
| 020008K | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 800 mm |
| 020008L | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 900 mm |
| 020008M | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 1000 - 1100mm |
| 020008N | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 1200 mm |
| 020008O | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 1350 - 1400mm |
| 020009A | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 80 mm & under |
| 020009B | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 100 mm |
| 020009C | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 125 -150 mm |
| 020009D | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 200 mm |
| 020009E | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 250 mm |
| 020009F | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 300 - 350 mm |
| 020009G | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 400 mm |
| 020009H | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 450 - 525mm |
| 020009I | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 600 - 675mm |
| 020009J | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 700 - 750 mm |
| 020009K | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 800 mm |
| 020009L | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 900 mm |
| 020009M | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 1000 - 1100mm |
| 020009N | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 1200 mm |
| 020009O | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 1350 - 1400mm |
| 020010A | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 80 mm & under |
| 020010B | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 100 mm |
| 020010C | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 125 -150 mm |
| 020010D | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 200 mm |
| 020010E | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 250 mm |
| 020010F | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 300 - 350 mm |
| 020010G | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 400 mm |
| 020010H | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 450 - 525mm |
| 020010I | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 600 - 675mm |
| 020010J | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 700 - 750 mm |
| 020010K | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 800 mm |
| 020010L | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 900 mm |
| 020010M | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 1000 - 1100mm |
| 020010N | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 1200 mm |
| 020010O | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 1350 - 1400mm |
| 020011B | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 100 mm |
| 020011C | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 125 -150 mm |
| 020011D | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 200 mm |
| 020011E | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 250 mm |
| 020011F | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 300 - 350 mm |
| 020011G | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 400 mm |
| 020011H | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 450 - 525mm |
| 020011I | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 600 - 675mm |
| 020011J | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 700 - 750 mm |
| 020011K | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 800 mm |
| 020011L | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 900 mm |
| 020011M | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 1000 - 1100mm |
| 020011N | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 1200 mm |
| 020011O | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 1350 - 1400mm |
| 020012B | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 100 mm |
| 020012C | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 125 -150 mm |
| 020012D | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 200 mm |
| 020012E | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 250 mm |
| 020012F | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 300 - 350 mm |
| 020012G | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 400 mm |
| 020012H | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 450 - 525mm |
| 020012I | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 600 - 675mm |
| 020012J | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 700 - 750 mm |
| 020012K | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 800 mm |
| 020012L | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 900 mm |
| 020012M | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 1000 - 1100mm |
| 020012N | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 1200 mm |
| 020012O | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 1350 - 1400mm |
| 020013B | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 100 mm |
| 020013C | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 125 -150 mm |
| 020013D | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 200 mm |
| 020013E | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 250 mm |
| 020013F | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 300 - 350 mm |
| 020013G | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 400 mm |
| 020013H | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 450 - 525mm |
| 020013I | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 600 - 675mm |
| 020013J | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 700 - 750 mm |
| 020013K | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 800 mm |
| 020013L | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 900 mm |
| 020013M | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 1000 - 1100mm |
| 020013N | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 1200 mm |
| 020013O | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 1350 - 1400mm |
| 020013P | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 1600 mm |
| 020013Q | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 1800 mm |
| 020013R | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 1950 - 2100 mm |
| 020013S | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe >2100 mm |
| 020014B | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 100 mm |
| 020014C | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 125 -150 mm |
| 020014D | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 200 mm |
| 020014E | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 250 mm |
| 020014F | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 300 - 350 mm |
| 020014G | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 400 mm |
| 020014H | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 450 - 525mm |
| 020014I | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 600 - 675mm |
| 020014J | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 700 - 750 mm |
| 020014K | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 800 mm |
| 020014L | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 900 mm |
| 020014M | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 1000 - 1100mm |
| 020014N | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 1200 mm |
| 020014O | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 1350 - 1400mm |
| 020014P | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 1600 mm |
| 020014Q | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 1800 mm |
| 020014R | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 1950 - 2100 mm |
| 020014S | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe >2100 mm |
| 020015B | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 100 mm |
| 020015C | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 125 -150 mm |
| 020015D | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 200 mm |
| 020015E | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 250 mm |
| 020015F | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 300 - 350 mm |
| 020015G | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 400 mm |
| 020015H | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 450 - 525mm |
| 020015I | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 600 - 675mm |
| 020015J | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 700 - 750 mm |
| 020015K | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 800 mm |
| 020015L | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 900 mm |
| 020015M | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 1000 - 1100mm |
| 020015N | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 1200 mm |
| 020015O | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 1350 - 1400mm |
| 020015P | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 1600 mm |
| 020015Q | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 1800 mm |
| 020015R | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 1950 - 2100 mm |
| 020015S | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe >2100 mm |
| 020016B | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 100 mm |
| 020016C | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 125 -150 mm |
| 020016D | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 200 mm |
| 020016E | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 250 mm |
| 020016F | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 300 - 350 mm |
| 020016G | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 400 mm |
| 020016H | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 450 - 525mm |
| 020016I | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 600 - 675mm |
| 020016J | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 700 - 750 mm |
| 020016K | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 800 mm |
| 020016L | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 900 mm |
| 020016M | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 1000 - 1100mm |
| 020016N | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 1200 mm |
| 020016O | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 1350 - 1400mm |
| 020016P | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 1600 mm |
| 020016Q | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 1800 mm |
| 020016R | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 1950 - 2100 mm |
| 020016S | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe >2100 mm |
| 020017B | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 100 mm |
| 020017C | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 125 -150 mm |
| 020017D | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 200 mm |
| 020017E | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 250 mm |
| 020017F | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 300 - 350 mm |
| 020017G | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 400 mm |
| 020017H | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 450 - 525mm |
| 020017I | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 600 - 675mm |
| 020017J | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 700 - 750 mm |
| 020017K | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 800 mm |
| 020017L | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 900 mm |
| 020017M | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 1000 - 1100mm |
| 020017N | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 1200 mm |
| 020017O | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 1350 - 1400mm |
| 020017P | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 1600 mm |
| 020017Q | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 1800 mm |
| 020017R | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 1950 - 2100 mm |
| 020017S | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe >2100 mm |
| 020018B | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 100 mm |
| 020018C | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 125 -150 mm |
| 020018D | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 200 mm |
| 020018E | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 250 mm |
| 020018F | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 300 - 350 mm |
| 020018G | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 400 mm |
| 020018H | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 450 - 525mm |
| 020018I | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 600 - 675mm |
| 020018J | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 700 - 750 mm |
| 020018K | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 800 mm |
| 020018L | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 900 mm |
| 020018M | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 1000 - 1100mm |
| 020018N | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 1200 mm |
| 020018O | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 1350 - 1400mm |
| 020018P | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 1600 mm |
| 020018Q | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 1800 mm |
| 020018R | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 1950 - 2100 mm |
| 020018S | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe >2100 mm |
| 020019B | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 100 mm |
| 020019C | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 125 -150 mm |
| 020019D | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 200 mm |
| 020019E | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 250 mm |
| 020019F | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 300 - 350 mm |
| 020019G | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 400 mm |
| 020019H | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 450 - 525mm |
| 020019I | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 600 - 675mm |
| 020019J | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 700 - 750 mm |
| 020019K | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 800 mm |
| 020019L | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 900 mm |
| 020019M | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 1000 - 1100mm |
| 020019N | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 1200 mm |
| 020019O | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 1350 - 1400mm |
| 020019P | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 1600 mm |
| 020020B | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 100 mm |
| 020020C | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 125 -150 mm |
| 020020D | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 200 mm |
| 020020E | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 250 mm |
| 020020F | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 300 - 350 mm |
| 020020G | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 400 mm |
| 020020H | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 450 - 525mm |
| 020020I | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 600 - 675mm |
| 020020J | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 700 - 750 mm |
| 020020K | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 800 mm |
| 020020L | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 900 mm |
| 020020M | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 1000 - 1100mm |
| 020020N | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 1200 mm |
| 020020O | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 1350 - 1400mm |
| 020020P | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 1600 mm |
| 020021B | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 100 mm |
| 020021C | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 125 -150 mm |
| 020021D | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 200 mm |
| 020021E | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 250 mm |
| 020021F | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 300 - 350 mm |
| 020021G | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 400 mm |
| 020021H | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 450 - 525mm |
| 020021I | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 600 - 675mm |
| 020021J | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 700 - 750 mm |
| 020021K | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 800 mm |
| 020021L | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 900 mm |
| 020021M | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 1000 - 1100mm |
| 020021N | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 1200 mm |
| 020021O | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 1350 - 1400mm |
| 020021P | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 1600 mm |
| 020022B | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 100 mm |
| 020022C | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 125 -150 mm |
| 020022D | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 200 mm |
| 020022E | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 250 mm |
| 020022F | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 300 - 350 mm |
| 020022G | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 400 mm |
| 020022H | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 450 - 525mm |
| 020022I | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 600 - 675mm |
| 020022J | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 700 - 750 mm |
| 020022K | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 800 mm |
| 020022L | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 900 mm |
| 020022M | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 1000 - 1100mm |
| 020022N | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 1200 mm |
| 020022O | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 1350 - 1400mm |
| 020022P | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 1600 mm |
| 020023B | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 100 mm |
| 020023C | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 125 -150 mm |
| 020023D | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 200 mm |
| 020023E | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 250 mm |
| 020023F | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 300 - 350 mm |
| 020023G | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 400 mm |
| 020023H | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 450 - 525mm |
| 020023I | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 600 - 675mm |
| 020023J | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 700 - 750 mm |
| 020023K | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 800 mm |
| 020023L | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 900 mm |
| 020023M | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 1000 - 1100mm |
| 020023N | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 1200 mm |
| 020023O | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 1350 - 1400mm |
| 020023P | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 1600 mm |
| 020024B | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 100 mm |
| 020024C | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 125 -150 mm |
| 020024D | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 200 mm |
| 020024E | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 250 mm |
| 020024F | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 300 - 350 mm |
| 020024G | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 400 mm |
| 020024H | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 450 - 525mm |
| 020024I | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 600 - 675mm |
| 020024J | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 700 - 750 mm |
| 020024K | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 800 mm |
| 020024L | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 900 mm |
| 020024M | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 1000 - 1100mm |
| 020024N | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 1200 mm |
| 020024O | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 1350 - 1400mm |
| 020024P | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 1600 mm |
| 020025A | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 15 mm |
| 020025B | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 20 mm |
| 020025C | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 25 mm |
| 020025D | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 40 mm |
| 020025E | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 50 mm |
| 020025F | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 80 mm |
| 020025G | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 100 mm |
| 020025H | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 150 mm |
| 020025I | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 200 mm |
| 020025J | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 250 mm |
| 020026A | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 15 mm |
| 020026B | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 20 mm |
| 020026C | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 25 mm |
| 020026D | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 40 mm |
| 020026E | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 50 mm |
| 020026F | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 80 mm |
| 020026G | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 100 mm |
| 020026H | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 150 mm |
| 020026I | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 200 mm |
| 020026J | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 250 mm |
| 020027A | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 15 mm |
| 020027B | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 20 mm |
| 020027C | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 25 mm |
| 020027D | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 40 mm |
| 020027E | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 50 mm |
| 020027F | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 80 mm |
| 020027G | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 100 mm |
| 020027H | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 150 mm |
| 020027I | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 200 mm |
| 020027J | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 250 mm |
| 020028A | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 15 mm |
| 020028B | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 20 mm |
| 020028C | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 25 mm |
| 020028D | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 40 mm |
| 020028E | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 50 mm |
| 020028F | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 80 mm |
| 020028G | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 100 mm |
| 020028H | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 150 mm |
| 020028I | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 200 mm |
| 020028J | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 250 mm |
| 020029G | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 100 mm |
| 020029H | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 150 mm |
| 020029I | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 200 mm |
| 020029J | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 250 mm |
| 020030G | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 100 mm |
| 020030H | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 150 mm |
| 020030I | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 200 mm |
| 020030J | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 250 mm |
| 020031A | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 15 mm |
| 020031B | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 20 mm |
| 020031C | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 25 mm |
| 020031D | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 40 mm |
| 020031E | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 50 mm |
| 020031F | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 80 mm |
| 020031G | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 100 mm |
| 020031H | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 150 mm |
| 020032A | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 15 mm |
| 020032B | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 20 mm |
| 020032C | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 25 mm |
| 020032D | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 40 mm |
| 020032E | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 50 mm |
| 020032F | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 80 mm |
| 020032G | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 100 mm |
| 020032H | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 150 mm |
| 020033A | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 15 mm |
| 020033B | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 20 mm |
| 020033C | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 25 mm |
| 020033D | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 40 mm |
| 020033E | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 50 mm |
| 020033F | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 80 mm |
| 020033G | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 100 mm |
| 020033H | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 150 mm |
| 020034A | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 15 mm |
| 020034B | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 20 mm |
| 020034C | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 25 mm |
| 020034D | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 40 mm |
| 020034E | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 50 mm |
| 020034F | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 80 mm |
| 020034G | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 100 mm |
| 020034H | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 150 mm |
| 020035G | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 100 mm |
| 020035H | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 150 mm |
| 020036G | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 100 mm |
| 020036H | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 150 mm |
| 020037A | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 15 mm |
| 020037B | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 20 mm |
| 020037C | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 25 mm |
| 020037D | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 40 mm |
| 020037E | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 50 mm |
| 020037F | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 80 mm |
| 020037G | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 100 mm |
| 020037H | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 150 mm |
| 020037I | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 200 mm |
| 020037J | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 250 mm |
| 020038A | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 15 mm |
| 020038B | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 20 mm |
| 020038C | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 25 mm |
| 020038D | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 40 mm |
| 020038E | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 50 mm |
| 020038F | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 80 mm |
| 020038G | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 100 mm |
| 020038H | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 150 mm |
| 020038I | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 200 mm |
| 020038J | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 250 mm |
| 020039A | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 15 mm |
| 020039B | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 20 mm |
| 020039C | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 25 mm |
| 020039D | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 40 mm |
| 020039E | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 50 mm |
| 020039F | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 80 mm |
| 020039G | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 100 mm |
| 020039H | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 150 mm |
| 020039I | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 200 mm |
| 020039J | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 250 mm |
| 020040A | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 15 mm |
| 020040B | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 20 mm |
| 020040C | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 25 mm |
| 020040D | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 40 mm |
| 020040E | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 50 mm |
| 020040F | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 80 mm |
| 020040G | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 100 mm |
| 020040H | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 150 mm |
| 020040I | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 200 mm |
| 020040J | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 250 mm |
| 020041G | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 100 mm |
| 020041H | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 150 mm |
| 020041I | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 200 mm |
| 020041J | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 250 mm |
| 020042G | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 100 mm |
| 020042H | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 150 mm |
| 020042I | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 200 mm |
| 020042J | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 250 mm |
| 020043A | (G) Stainless Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 15 mm |
| 020043B | (G) Stainless Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 20 mm |
| 020043C | (G) Stainless Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 25 mm |
| 020043D | (G) Stainless Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 40 mm |
| 020043E | (G) Stainless Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 50 mm |
| 020043F | (G) Stainless Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 80 mm |
| 020043G | (G) Stainless Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 100 mm |
| 020043H | (G) Stainless Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 150 mm |
| 020043I | (G) Stainless Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 200 mm |
| 020044A | (G) Stainless Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 15 mm |
| 020044B | (G) Stainless Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 20 mm |
| 020044C | (G) Stainless Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 25 mm |
| 020044D | (G) Stainless Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 40 mm |
| 020044E | (G) Stainless Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 50 mm |
| 020044F | (G) Stainless Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 80 mm |
| 020044G | (G) Stainless Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 100 mm |
| 020044H | (G) Stainless Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 150 mm |
| 020044I | (G) Stainless Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 200 mm |
| 020045A | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 80 mm & under |
| 020045B | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 100 mm |
| 020045C | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 125 -150 mm |
| 020045D | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 200 mm |
| 020045E | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 250 mm |
| 020045F | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 300 - 350 mm |
| 020045G | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 400 mm |
| 020045H | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 450 - 525mm |
| 020045I | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 600 - 675mm |
| 020045J | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 700 - 750 mm |
| 020045K | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 800 mm |
| 020045L | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 900 mm |
| 020045M | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 1000 - 1100mm |
| 020045N | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 1200 mm |
| 020045O | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 1350 - 1400mm |
| 020046A | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 80 mm & under |
| 020046B | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 100 mm |
| 020046C | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 125 -150 mm |
| 020046D | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 200 mm |
| 020046E | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 250 mm |
| 020046F | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 300 - 350 mm |
| 020046G | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 400 mm |
| 020046H | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 450 - 525mm |
| 020046I | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 600 - 675mm |
| 020046J | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 700 - 750 mm |
| 020046K | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 800 mm |
| 020046L | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 900 mm |
| 020046M | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 1000 - 1100mm |
| 020046N | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 1200 mm |
| 020046O | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 1350 - 1400mm |
| 020047A | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 80 mm & under |
| 020047B | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 100 mm |
| 020047C | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 125 -150 mm |
| 020047D | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 200 mm |
| 020047E | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 250 mm |
| 020047F | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 300 - 350 mm |
| 020047G | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 400 mm |
| 020047H | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 450 - 525mm |
| 020047I | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 600 - 675mm |
| 020047J | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 700 - 750 mm |
| 020047K | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 800 mm |
| 020047L | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 900 mm |
| 020047M | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 1000 - 1100mm |
| 020047N | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 1200 mm |
| 020047O | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 1350 - 1400mm |
| 020048A | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 80 mm & under |
| 020048B | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 100 mm |
| 020048C | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 125 -150 mm |
| 020048D | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 200 mm |
| 020048E | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 250 mm |
| 020048F | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 300 - 350 mm |
| 020048G | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 400 mm |
| 020048H | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 450 - 525mm |
| 020048I | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 600 - 675mm |
| 020048J | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 700 - 750 mm |
| 020048K | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 800 mm |
| 020048L | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 900 mm |
| 020048M | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 1000 - 1100mm |
| 020048N | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 1200 mm |
| 020048O | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 1350 - 1400mm |
| 020049B | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 100 mm |
| 020049C | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 125 -150 mm |
| 020049D | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 200 mm |
| 020049E | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 250 mm |
| 020049F | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 300 - 350 mm |
| 020049G | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 400 mm |
| 020049H | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 450 - 525mm |
| 020049I | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 600 - 675mm |
| 020049J | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 700 - 750 mm |
| 020049K | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 800 mm |
| 020049L | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 900 mm |
| 020049M | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 1000 - 1100mm |
| 020049N | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 1200 mm |
| 020049O | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 1350 - 1400mm |
| 020050B | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 100 mm |
| 020050C | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 125 -150 mm |
| 020050D | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 200 mm |
| 020050E | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 250 mm |
| 020050F | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 300 - 350 mm |
| 020050G | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 400 mm |
| 020050H | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 450 - 525mm |
| 020050I | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 600 - 675mm |
| 020050J | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 700 - 750 mm |
| 020050K | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 800 mm |
| 020050L | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 900 mm |
| 020050M | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 1000 - 1100mm |
| 020050N | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 1200 mm |
| 020050O | (A) Cast Iron/Ductile Iron Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 1350 - 1400mm |
| 020051A | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 80 mm & under |
| 020051B | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 100 mm |
| 020051C | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 125 -150 mm |
| 020051D | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 200 mm |
| 020051E | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 250 mm |
| 020051F | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 300 - 350 mm |
| 020051G | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 400 mm |
| 020051H | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 450 - 525mm |
| 020051I | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 600 - 675mm |
| 020051J | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 700 - 750 mm |
| 020051K | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 800 mm |
| 020051L | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 900 mm |
| 020051M | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 1000 - 1100mm |
| 020051N | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 1200 mm |
| 020051O | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 1350 - 1400mm |
| 020051P | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 1600 mm |
| 020051Q | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 1800 mm |
| 020051R | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 1950 - 2100 mm |
| 020051S | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe >2100 mm |
| 020052A | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 80 mm & under |
| 020052B | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 100 mm |
| 020052C | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 125 -150 mm |
| 020052D | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 200 mm |
| 020052E | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 250 mm |
| 020052F | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 300 - 350 mm |
| 020052G | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 400 mm |
| 020052H | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 450 - 525mm |
| 020052I | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 600 - 675mm |
| 020052J | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 700 - 750 mm |
| 020052K | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 800 mm |
| 020052L | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 900 mm |
| 020052M | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 1000 - 1100mm |
| 020052N | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 1200 mm |
| 020052O | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 1350 - 1400mm |
| 020052P | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 1600 mm |
| 020052Q | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 1800 mm |
| 020052R | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 1950 - 2100 mm |
| 020052S | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe >2100 mm |
| 020053A | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 80 mm & under |
| 020053B | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 100 mm |
| 020053C | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 125 -150 mm |
| 020053D | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 200 mm |
| 020053E | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 250 mm |
| 020053F | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 300 - 350 mm |
| 020053G | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 400 mm |
| 020053H | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 450 - 525mm |
| 020053I | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 600 - 675mm |
| 020053J | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 700 - 750 mm |
| 020053K | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 800 mm |
| 020053L | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 900 mm |
| 020053M | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 1000 - 1100mm |
| 020053N | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 1200 mm |
| 020053O | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 1350 - 1400mm |
| 020053P | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 1600 mm |
| 020053Q | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 1800 mm |
| 020053R | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 1950 - 2100 mm |
| 020053S | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe >2100 mm |
| 020054A | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 80 mm & under |
| 020054B | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 100 mm |
| 020054C | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 125 -150 mm |
| 020054D | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 200 mm |
| 020054E | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 250 mm |
| 020054F | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 300 - 350 mm |
| 020054G | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 400 mm |
| 020054H | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 450 - 525mm |
| 020054I | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 600 - 675mm |
| 020054J | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 700 - 750 mm |
| 020054K | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 800 mm |
| 020054L | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 900 mm |
| 020054M | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 1000 - 1100mm |
| 020054N | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 1200 mm |
| 020054O | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 1350 - 1400mm |
| 020054P | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 1600 mm |
| 020054Q | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 1800 mm |
| 020054R | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 1950 - 2100 mm |
| 020054S | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe >2100 mm |
| 020055B | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 100 mm |
| 020055C | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 125 -150 mm |
| 020055D | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 200 mm |
| 020055E | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 250 mm |
| 020055F | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 300 - 350 mm |
| 020055G | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 400 mm |
| 020055H | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 450 - 525mm |
| 020055I | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 600 - 675mm |
| 020055J | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 700 - 750 mm |
| 020055K | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 800 mm |
| 020055L | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 900 mm |
| 020055M | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 1000 - 1100mm |
| 020055N | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 1200 mm |
| 020055O | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 1350 - 1400mm |
| 020055P | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 1600 mm |
| 020055Q | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 1800 mm |
| 020055R | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 1950 - 2100 mm |
| 020055S | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe >2100 mm |
| 020056B | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 100 mm |
| 020056C | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 125 -150 mm |
| 020056D | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 200 mm |
| 020056E | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 250 mm |
| 020056F | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 300 - 350 mm |
| 020056G | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 400 mm |
| 020056H | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 450 - 525mm |
| 020056I | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 600 - 675mm |
| 020056J | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 700 - 750 mm |
| 020056K | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 800 mm |
| 020056L | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 900 mm |
| 020056M | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 1000 - 1100mm |
| 020056N | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 1200 mm |
| 020056O | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 1350 - 1400mm |
| 020056P | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 1600 mm |
| 020056Q | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 1800 mm |
| 020056R | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 1950 - 2100 mm |
| 020056S | (B) Bitumen Lined Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe >2100 mm |
| 020057A | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 80 mm & under |
| 020057B | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 100 mm |
| 020057C | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 125 -150 mm |
| 020057D | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 200 mm |
| 020057E | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 250 mm |
| 020057F | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 300 - 350 mm |
| 020057G | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 400 mm |
| 020057H | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 450 - 525mm |
| 020057I | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 600 - 675mm |
| 020057J | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 700 - 750 mm |
| 020057K | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 800 mm |
| 020057L | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 900 mm |
| 020057M | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 1000 - 1100mm |
| 020057N | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 1200 mm |
| 020057O | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 1350 - 1400mm |
| 020057P | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 1600 mm |
| 020058A | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 80 mm & under |
| 020058B | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 100 mm |
| 020058C | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 125 -150 mm |
| 020058D | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 200 mm |
| 020058E | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 250 mm |
| 020058F | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 300 - 350 mm |
| 020058G | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 400 mm |
| 020058H | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 450 - 525mm |
| 020058I | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 600 - 675mm |
| 020058J | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 700 - 750 mm |
| 020058K | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 800 mm |
| 020058L | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 900 mm |
| 020058M | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 1000 - 1100mm |
| 020058N | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 1200 mm |
| 020058O | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 1350 - 1400mm |
| 020058P | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 1600 mm |
| 020059A | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 80 mm & under |
| 020059B | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 100 mm |
| 020059C | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 125 -150 mm |
| 020059D | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 200 mm |
| 020059E | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 250 mm |
| 020059F | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 300 - 350 mm |
| 020059G | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 400 mm |
| 020059H | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 450 - 525mm |
| 020059I | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 600 - 675mm |
| 020059J | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 700 - 750 mm |
| 020059K | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 800 mm |
| 020059L | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 900 mm |
| 020059M | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 1000 - 1100mm |
| 020059N | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 1200 mm |
| 020059O | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 1350 - 1400mm |
| 020059P | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 1600 mm |
| 020060A | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 80 mm & under |
| 020060B | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 100 mm |
| 020060C | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 125 -150 mm |
| 020060D | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 200 mm |
| 020060E | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 250 mm |
| 020060F | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 300 - 350 mm |
| 020060G | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 400 mm |
| 020060H | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 450 - 525mm |
| 020060I | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 600 - 675mm |
| 020060J | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 700 - 750 mm |
| 020060K | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 800 mm |
| 020060L | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 900 mm |
| 020060M | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 1000 - 1100mm |
| 020060N | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 1200 mm |
| 020060O | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 1350 - 1400mm |
| 020060P | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 1600 mm |
| 020061B | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 100 mm |
| 020061C | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 125 -150 mm |
| 020061D | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 200 mm |
| 020061E | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 250 mm |
| 020061F | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 300 - 350 mm |
| 020061G | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 400 mm |
| 020061H | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 450 - 525mm |
| 020061I | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 600 - 675mm |
| 020061J | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 700 - 750 mm |
| 020061K | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 800 mm |
| 020061L | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 900 mm |
| 020061M | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 1000 - 1100mm |
| 020061N | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 1200 mm |
| 020061O | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 1350 - 1400mm |
| 020061P | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 1600 mm |
| 020062B | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 100 mm |
| 020062C | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 125 -150 mm |
| 020062D | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 200 mm |
| 020062E | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 250 mm |
| 020062F | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 300 - 350 mm |
| 020062G | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 400 mm |
| 020062H | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 450 - 525mm |
| 020062I | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 600 - 675mm |
| 020062J | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 700 - 750 mm |
| 020062K | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 800 mm |
| 020062L | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 900 mm |
| 020062M | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 1000 - 1100mm |
| 020062N | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 1200 mm |
| 020062O | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 1350 - 1400mm |
| 020062P | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 1600 mm |
| 020063A | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 15 mm |
| 020063B | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 20 mm |
| 020063C | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 25 mm |
| 020063D | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 40 mm |
| 020063E | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 50 mm |
| 020063F | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 80 mm |
| 020063G | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 100 mm |
| 020063H | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 150 mm |
| 020063I | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 200 mm |
| 020063J | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 250 mm |
| 020064A | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 15 mm |
| 020064B | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 20 mm |
| 020064C | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 25 mm |
| 020064D | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 40 mm |
| 020064E | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 50 mm |
| 020064F | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 80 mm |
| 020064G | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 100 mm |
| 020064H | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 150 mm |
| 020064I | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 200 mm |
| 020064J | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 250 mm |
| 020065A | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 15 mm |
| 020065B | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 20 mm |
| 020065C | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 25 mm |
| 020065D | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 40 mm |
| 020065E | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 50 mm |
| 020065F | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 80 mm |
| 020065G | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 100 mm |
| 020065H | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 150 mm |
| 020065I | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 200 mm |
| 020065J | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 250 mm |
| 020066A | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 15 mm |
| 020066B | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 20 mm |
| 020066C | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 25 mm |
| 020066D | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 40 mm |
| 020066E | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 50 mm |
| 020066F | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 80 mm |
| 020066G | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 100 mm |
| 020066H | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 150 mm |
| 020066I | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 200 mm |
| 020066J | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 250 mm |
| 020067G | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 100 mm |
| 020067H | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 150 mm |
| 020067I | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 200 mm |
| 020067J | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 250 mm |
| 020068G | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 100 mm |
| 020068H | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 150 mm |
| 020068I | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 200 mm |
| 020068J | (D) UPVC Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 250 mm |
| 020069A | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 15 mm |
| 020069B | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 20 mm |
| 020069C | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 25 mm |
| 020069D | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 40 mm |
| 020069E | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 50 mm |
| 020069F | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 80 mm |
| 020069G | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 100 mm |
| 020069H | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 150 mm |
| 020070A | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 15 mm |
| 020070B | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 20 mm |
| 020070C | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 25 mm |
| 020070D | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 40 mm |
| 020070E | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 50 mm |
| 020070F | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 80 mm |
| 020070G | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 100 mm |
| 020070H | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 150 mm |
| 020071A | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 15 mm |
| 020071B | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 20 mm |
| 020071C | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 25 mm |
| 020071D | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 40 mm |
| 020071E | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 50 mm |
| 020071F | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 80 mm |
| 020071G | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 100 mm |
| 020071H | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 150 mm |
| 020072A | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 15 mm |
| 020072B | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 20 mm |
| 020072C | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 25 mm |
| 020072D | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 40 mm |
| 020072E | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 50 mm |
| 020072F | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 80 mm |
| 020072G | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 100 mm |
| 020072H | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 150 mm |
| 020073G | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 100 mm |
| 020073H | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 150 mm |
| 020074G | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 100 mm |
| 020074H | (E) Lined G.I. Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 150 mm |
| 020075A | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 15 mm |
| 020075B | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 20 mm |
| 020075C | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 25 mm |
| 020075D | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 40 mm |
| 020075E | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 50 mm |
| 020075F | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 80 mm |
| 020075G | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 100 mm |
| 020075H | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 150 mm |
| 020075I | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 200 mm |
| 020075J | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 250 mm |
| 020076A | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 15 mm |
| 020076B | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 20 mm |
| 020076C | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 25 mm |
| 020076D | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 40 mm |
| 020076E | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 50 mm |
| 020076F | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 80 mm |
| 020076G | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 100 mm |
| 020076H | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 150 mm |
| 020076I | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 200 mm |
| 020076J | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 250 mm |
| 020077A | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 15 mm |
| 020077B | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 20 mm |
| 020077C | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 25 mm |
| 020077D | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 40 mm |
| 020077E | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 50 mm |
| 020077F | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 80 mm |
| 020077G | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 100 mm |
| 020077H | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 150 mm |
| 020077I | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 200 mm |
| 020077J | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 250 mm |
| 020078A | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 15 mm |
| 020078B | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 20 mm |
| 020078C | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 25 mm |
| 020078D | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 40 mm |
| 020078E | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 50 mm |
| 020078F | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 80 mm |
| 020078G | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 100 mm |
| 020078H | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 150 mm |
| 020078I | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 200 mm |
| 020078J | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 250 mm |
| 020079G | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 100 mm |
| 020079H | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 150 mm |
| 020079I | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 200 mm |
| 020079J | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 250 mm |
| 020080G | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 100 mm |
| 020080H | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 150 mm |
| 020080I | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 200 mm |
| 020080J | (F) PE Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 250 mm |
| 020081A | (G) Stainless Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 15 mm |
| 020081B | (G) Stainless Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 20 mm |
| 020081C | (G) Stainless Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 25 mm |
| 020081D | (G) Stainless Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 40 mm |
| 020081E | (G) Stainless Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 50 mm |
| 020081F | (G) Stainless Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 80 mm |
| 020081G | (G) Stainless Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 100 mm |
| 020081H | (G) Stainless Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 150 mm |
| 020081I | (G) Stainless Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 200 mm |
| 020082A | (G) Stainless Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 15 mm |
| 020082B | (G) Stainless Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 20 mm |
| 020082C | (G) Stainless Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 25 mm |
| 020082D | (G) Stainless Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 40 mm |
| 020082E | (G) Stainless Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 50 mm |
| 020082F | (G) Stainless Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 80 mm |
| 020082G | (G) Stainless Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 100 mm |
| 020082H | (G) Stainless Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 150 mm |
| 020082I | (G) Stainless Steel Pipes in trench with granular bedding or concrete haunching (Type 1-3), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 200 mm |
| 020083A | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 80 mm & under |
| 020083B | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 100 mm |
| 020083C | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 125 -150 mm |
| 020083D | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 200 mm |
| 020083E | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 250 mm |
| 020083F | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 300 - 350 mm |
| 020083G | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 400 mm |
| 020083H | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 450 - 525mm |
| 020083I | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 600 - 675mm |
| 020083J | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 700 - 750 mm |
| 020083K | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 800 mm |
| 020083L | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 900 mm |
| 020083M | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 1000 - 1100mm |
| 020083N | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 1200 mm |
| 020083O | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 1350 - 1400mm |
| 020084A | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 80 mm & under |
| 020084B | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 100 mm |
| 020084C | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 125 -150 mm |
| 020084D | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 200 mm |
| 020084E | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 250 mm |
| 020084F | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 300 - 350 mm |
| 020084G | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 400 mm |
| 020084H | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 450 - 525mm |
| 020084I | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 600 - 675mm |
| 020084J | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 700 - 750 mm |
| 020084K | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 800 mm |
| 020084L | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 900 mm |
| 020084M | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 1000 - 1100mm |
| 020084N | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 1200 mm |
| 020084O | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 1350 - 1400mm |
| 020085A | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 80 mm & under |
| 020085B | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 100 mm |
| 020085C | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 125 -150 mm |
| 020085D | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 200 mm |
| 020085E | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 250 mm |
| 020085F | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 300 - 350 mm |
| 020085G | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 400 mm |
| 020085H | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 450 - 525mm |
| 020085I | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 600 - 675mm |
| 020085J | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 700 - 750 mm |
| 020085K | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 800 mm |
| 020085L | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 900 mm |
| 020085M | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 1000 - 1100mm |
| 020085N | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 1200 mm |
| 020085O | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 1350 - 1400mm |
| 020086A | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 80 mm & under |
| 020086B | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 100 mm |
| 020086C | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 125 -150 mm |
| 020086D | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 200 mm |
| 020086E | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 250 mm |
| 020086F | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 300 - 350 mm |
| 020086G | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 400 mm |
| 020086H | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 450 - 525mm |
| 020086I | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 600 - 675mm |
| 020086J | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 700 - 750 mm |
| 020086K | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 800 mm |
| 020086L | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 900 mm |
| 020086M | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 1000 - 1100mm |
| 020086N | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 1200 mm |
| 020086O | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 1350 - 1400mm |
| 020087B | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 100 mm |
| 020087C | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 125 -150 mm |
| 020087D | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 200 mm |
| 020087E | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 250 mm |
| 020087F | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 300 - 350 mm |
| 020087G | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 400 mm |
| 020087H | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 450 - 525mm |
| 020087I | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 600 - 675mm |
| 020087J | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 700 - 750 mm |
| 020087K | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 800 mm |
| 020087L | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 900 mm |
| 020087M | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 1000 - 1100mm |
| 020087N | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 1200 mm |
| 020087O | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 1350 - 1400mm |
| 020088B | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 100 mm |
| 020088C | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 125 -150 mm |
| 020088D | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 200 mm |
| 020088E | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 250 mm |
| 020088F | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 300 - 350 mm |
| 020088G | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 400 mm |
| 020088H | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 450 - 525mm |
| 020088I | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 600 - 675mm |
| 020088J | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 700 - 750 mm |
| 020088K | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 800 mm |
| 020088L | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 900 mm |
| 020088M | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 1000 - 1100mm |
| 020088N | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 1200 mm |
| 020088O | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 1350 - 1400mm |
| 020089A | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 80 mm & under |
| 020089B | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 100 mm |
| 020089C | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 125 -150 mm |
| 020089D | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 200 mm |
| 020089E | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 250 mm |
| 020089F | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 300 - 350 mm |
| 020089G | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 400 mm |
| 020089H | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 450 - 525mm |
| 020089I | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 600 - 675mm |
| 020089J | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 700 - 750 mm |
| 020089K | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 800 mm |
| 020089L | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 900 mm |
| 020089M | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 1000 - 1100mm |
| 020089N | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 1200 mm |
| 020089O | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 1350 - 1400mm |
| 020089P | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 1600 mm |
| 020089Q | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 1800 mm |
| 020089R | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 1950 - 2100 mm |
| 020089S | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe >2100 mm |
| 020090A | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 80 mm & under |
| 020090B | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 100 mm |
| 020090C | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 125 -150 mm |
| 020090D | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 200 mm |
| 020090E | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 250 mm |
| 020090F | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 300 - 350 mm |
| 020090G | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 400 mm |
| 020090H | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 450 - 525mm |
| 020090I | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 600 - 675mm |
| 020090J | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 700 - 750 mm |
| 020090K | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 800 mm |
| 020090L | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 900 mm |
| 020090M | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 1000 - 1100mm |
| 020090N | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 1200 mm |
| 020090O | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 1350 - 1400mm |
| 020090P | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 1600 mm |
| 020090Q | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 1800 mm |
| 020090R | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 1950 - 2100 mm |
| 020090S | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe >2100 mm |
| 020091A | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 80 mm & under |
| 020091B | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 100 mm |
| 020091C | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 125 -150 mm |
| 020091D | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 200 mm |
| 020091E | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 250 mm |
| 020091F | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 300 - 350 mm |
| 020091G | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 400 mm |
| 020091H | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 450 - 525mm |
| 020091I | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 600 - 675mm |
| 020091J | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 700 - 750 mm |
| 020091K | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 800 mm |
| 020091L | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 900 mm |
| 020091M | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 1000 - 1100mm |
| 020091N | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 1200 mm |
| 020091O | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 1350 - 1400mm |
| 020091P | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 1600 mm |
| 020091Q | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 1800 mm |
| 020091R | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 1950 - 2100 mm |
| 020091S | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe >2100 mm |
| 020092A | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 80 mm & under |
| 020092B | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 100 mm |
| 020092C | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 125 -150 mm |
| 020092D | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 200 mm |
| 020092E | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 250 mm |
| 020092F | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 300 - 350 mm |
| 020092G | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 400 mm |
| 020092H | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 450 - 525mm |
| 020092I | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 600 - 675mm |
| 020092J | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 700 - 750 mm |
| 020092K | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 800 mm |
| 020092L | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 900 mm |
| 020092M | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 1000 - 1100mm |
| 020092N | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 1200 mm |
| 020092O | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 1350 - 1400mm |
| 020092P | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 1600 mm |
| 020092Q | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 1800 mm |
| 020092R | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 1950 - 2100 mm |
| 020092S | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe >2100 mm |
| 020093B | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 100 mm |
| 020093C | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 125 -150 mm |
| 020093D | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 200 mm |
| 020093E | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 250 mm |
| 020093F | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 300 - 350 mm |
| 020093G | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 400 mm |
| 020093H | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 450 - 525mm |
| 020093I | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 600 - 675mm |
| 020093J | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 700 - 750 mm |
| 020093K | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 800 mm |
| 020093L | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 900 mm |
| 020093M | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 1000 - 1100mm |
| 020093N | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 1200 mm |
| 020093O | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 1350 - 1400mm |
| 020093P | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 1600 mm |
| 020093Q | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 1800 mm |
| 020093R | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 1950 - 2100 mm |
| 020093S | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe >2100 mm |
| 020094B | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 100 mm |
| 020094C | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 125 -150 mm |
| 020094D | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 200 mm |
| 020094E | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 250 mm |
| 020094F | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 300 - 350 mm |
| 020094G | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 400 mm |
| 020094H | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 450 - 525mm |
| 020094I | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 600 - 675mm |
| 020094J | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 700 - 750 mm |
| 020094K | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 800 mm |
| 020094L | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 900 mm |
| 020094M | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 1000 - 1100mm |
| 020094N | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 1200 mm |
| 020094O | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 1350 - 1400mm |
| 020094P | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 1600 mm |
| 020094Q | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 1800 mm |
| 020094R | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 1950 - 2100 mm |
| 020094S | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe >2100 mm |
| 020095A | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 80 mm & under |
| 020095B | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 100 mm |
| 020095C | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 125 -150 mm |
| 020095D | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 200 mm |
| 020095E | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 250 mm |
| 020095F | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 300 - 350 mm |
| 020095G | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 400 mm |
| 020095H | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 450 - 525mm |
| 020095I | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 600 - 675mm |
| 020095J | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 700 - 750 mm |
| 020095K | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 800 mm |
| 020095L | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 900 mm |
| 020095M | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 1000 - 1100mm |
| 020095N | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 1200 mm |
| 020095O | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 1350 - 1400mm |
| 020095P | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 1600 mm |
| 020096A | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 80 mm & under |
| 020096B | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 100 mm |
| 020096C | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 125 -150 mm |
| 020096D | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 200 mm |
| 020096E | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 250 mm |
| 020096F | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 300 - 350 mm |
| 020096G | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 400 mm |
| 020096H | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 450 - 525mm |
| 020096I | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 600 - 675mm |
| 020096J | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 700 - 750 mm |
| 020096K | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 800 mm |
| 020096L | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 900 mm |
| 020096M | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 1000 - 1100mm |
| 020096N | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 1200 mm |
| 020096O | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 1350 - 1400mm |
| 020096P | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 1600 mm |
| 020097A | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 80 mm & under |
| 020097B | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 100 mm |
| 020097C | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 125 -150 mm |
| 020097D | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 200 mm |
| 020097E | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 250 mm |
| 020097F | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 300 - 350 mm |
| 020097G | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 400 mm |
| 020097H | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 450 - 525mm |
| 020097I | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 600 - 675mm |
| 020097J | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 700 - 750 mm |
| 020097K | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 800 mm |
| 020097L | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 900 mm |
| 020097M | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 1000 - 1100mm |
| 020097N | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 1200 mm |
| 020097O | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 1350 - 1400mm |
| 020097P | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 1600 mm |
| 020098A | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 80 mm & under |
| 020098B | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 100 mm |
| 020098C | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 125 -150 mm |
| 020098D | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 200 mm |
| 020098E | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 250 mm |
| 020098F | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 300 - 350 mm |
| 020098G | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 400 mm |
| 020098H | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 450 - 525mm |
| 020098I | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 600 - 675mm |
| 020098J | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 700 - 750 mm |
| 020098K | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 800 mm |
| 020098L | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 900 mm |
| 020098M | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 1000 - 1100mm |
| 020098N | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 1200 mm |
| 020098O | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 1350 - 1400mm |
| 020098P | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 1600 mm |
| 020099B | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 100 mm |
| 020099C | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 125 -150 mm |
| 020099D | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 200 mm |
| 020099E | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 250 mm |
| 020099F | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 300 - 350 mm |
| 020099G | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 400 mm |
| 020099H | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 450 - 525mm |
| 020099I | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 600 - 675mm |
| 020099J | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 700 - 750 mm |
| 020099K | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 800 mm |
| 020099L | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 900 mm |
| 020099M | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 1000 - 1100mm |
| 020099N | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 1200 mm |
| 020099O | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 1350 - 1400mm |
| 020099P | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 1600 mm |
| 020100B | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 100 mm |
| 020100C | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 125 -150 mm |
| 020100D | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 200 mm |
| 020100E | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 250 mm |
| 020100F | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 300 - 350 mm |
| 020100G | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 400 mm |
| 020100H | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 450 - 525mm |
| 020100I | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 600 - 675mm |
| 020100J | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 700 - 750 mm |
| 020100K | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 800 mm |
| 020100L | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 900 mm |
| 020100M | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 1000 - 1100mm |
| 020100N | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 1200 mm |
| 020100O | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 1350 - 1400mm |
| 020100P | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 1600 mm |
| 020101A | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 15 mm |
| 020101B | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 20 mm |
| 020101C | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 25 mm |
| 020101D | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 40 mm |
| 020101E | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 50 mm |
| 020101F | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 80 mm |
| 020101G | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 100 mm |
| 020101H | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 150 mm |
| 020101I | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 200 mm |
| 020101J | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 250 mm |
| 020102A | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 15 mm |
| 020102B | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 20 mm |
| 020102C | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 25 mm |
| 020102D | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 40 mm |
| 020102E | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 50 mm |
| 020102F | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 80 mm |
| 020102G | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 100 mm |
| 020102H | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 150 mm |
| 020102I | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 200 mm |
| 020102J | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 250 mm |
| 020103A | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 15 mm |
| 020103B | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 20 mm |
| 020103C | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 25 mm |
| 020103D | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 40 mm |
| 020103E | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 50 mm |
| 020103F | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 80 mm |
| 020103G | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 100 mm |
| 020103H | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 150 mm |
| 020103I | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 200 mm |
| 020103J | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 250 mm |
| 020104A | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 15 mm |
| 020104B | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 20 mm |
| 020104C | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 25 mm |
| 020104D | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 40 mm |
| 020104E | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 50 mm |
| 020104F | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 80 mm |
| 020104G | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 100 mm |
| 020104H | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 150 mm |
| 020104I | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 200 mm |
| 020104J | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 250 mm |
| 020105G | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 100 mm |
| 020105H | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 150 mm |
| 020105I | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 200 mm |
| 020105J | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 250 mm |
| 020106G | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 100 mm |
| 020106H | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 150 mm |
| 020106I | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 200 mm |
| 020106J | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 250 mm |
| 020107A | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 15 mm |
| 020107B | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 20 mm |
| 020107C | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 25 mm |
| 020107D | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 40 mm |
| 020107E | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 50 mm |
| 020107F | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 80 mm |
| 020107G | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 100 mm |
| 020107H | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 150 mm |
| 020108A | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 15 mm |
| 020108B | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 20 mm |
| 020108C | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 25 mm |
| 020108D | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 40 mm |
| 020108E | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 50 mm |
| 020108F | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 80 mm |
| 020108G | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 100 mm |
| 020108H | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 150 mm |
| 020109A | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 15 mm |
| 020109B | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 20 mm |
| 020109C | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 25 mm |
| 020109D | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 40 mm |
| 020109E | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 50 mm |
| 020109F | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 80 mm |
| 020109G | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 100 mm |
| 020109H | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 150 mm |
| 020110A | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 15 mm |
| 020110B | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 20 mm |
| 020110C | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 25 mm |
| 020110D | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 40 mm |
| 020110E | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 50 mm |
| 020110F | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 80 mm |
| 020110G | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 100 mm |
| 020110H | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 150 mm |
| 020111G | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 100 mm |
| 020111H | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 150 mm |
| 020112G | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 100 mm |
| 020112H | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 150 mm |
| 020113A | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 15 mm |
| 020113B | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 20 mm |
| 020113C | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 25 mm |
| 020113D | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 40 mm |
| 020113E | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 50 mm |
| 020113F | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 80 mm |
| 020113G | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 100 mm |
| 020113H | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 150 mm |
| 020113I | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 200 mm |
| 020113J | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 250 mm |
| 020114A | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 15 mm |
| 020114B | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 20 mm |
| 020114C | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 25 mm |
| 020114D | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 40 mm |
| 020114E | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 50 mm |
| 020114F | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 80 mm |
| 020114G | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 100 mm |
| 020114H | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 150 mm |
| 020114I | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 200 mm |
| 020114J | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 250 mm |
| 020115A | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 15 mm |
| 020115B | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 20 mm |
| 020115C | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 25 mm |
| 020115D | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 40 mm |
| 020115E | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 50 mm |
| 020115F | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 80 mm |
| 020115G | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 100 mm |
| 020115H | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 150 mm |
| 020115I | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 200 mm |
| 020115J | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=2.5, T=3.5 Nominal diameter of pipe 250 mm |
| 020116A | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 15 mm |
| 020116B | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 20 mm |
| 020116C | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 25 mm |
| 020116D | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 40 mm |
| 020116E | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 50 mm |
| 020116F | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 80 mm |
| 020116G | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 100 mm |
| 020116H | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 150 mm |
| 020116I | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 200 mm |
| 020116J | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=3.5, T=4.5 Nominal diameter of pipe 250 mm |
| 020117G | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 100 mm |
| 020117H | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 150 mm |
| 020117I | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 200 mm |
| 020117J | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=4.5, T=5.5 Nominal diameter of pipe 250 mm |
| 020118G | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 100 mm |
| 020118H | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 150 mm |
| 020118I | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 200 mm |
| 020118J | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=5.5, T=6.5 Nominal diameter of pipe 250 mm |
| 020119A | (G) Stainless Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 15 mm |
| 020119B | (G) Stainless Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 20 mm |
| 020119C | (G) Stainless Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 25 mm |
| 020119D | (G) Stainless Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 40 mm |
| 020119E | (G) Stainless Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 50 mm |
| 020119F | (G) Stainless Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 80 mm |
| 020119G | (G) Stainless Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 100 mm |
| 020119H | (G) Stainless Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 150 mm |
| 020119I | (G) Stainless Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=0, T=1.5 Nominal diameter of pipe 200 mm |
| 020120A | (G) Stainless Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 15 mm |
| 020120B | (G) Stainless Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 20 mm |
| 020120C | (G) Stainless Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 25 mm |
| 020120D | (G) Stainless Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 40 mm |
| 020120E | (G) Stainless Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 50 mm |
| 020120F | (G) Stainless Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 80 mm |
| 020120G | (G) Stainless Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 100 mm |
| 020120H | (G) Stainless Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 150 mm |
| 020120I | (G) Stainless Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (End Product Specification) S=1.5, T=2.5 Nominal diameter of pipe 200 mm |
| 020121A | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 80 mm & under |
| 020121B | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 100 mm |
| 020121C | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 125 -150 mm |
| 020121D | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 200 mm |
| 020121E | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 250 mm |
| 020121F | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 300 - 350 mm |
| 020121G | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 400 mm |
| 020121H | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 450 - 525mm |
| 020121I | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 600 - 675mm |
| 020121J | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 700 - 750 mm |
| 020121K | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 800 mm |
| 020121L | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 900 mm |
| 020121M | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 1000 - 1100mm |
| 020121N | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 1200 mm |
| 020121O | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 1350 - 1400mm |
| 020122A | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 80 mm & under |
| 020122B | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 100 mm |
| 020122C | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 125 -150 mm |
| 020122D | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 200 mm |
| 020122E | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 250 mm |
| 020122F | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 300 - 350 mm |
| 020122G | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 400 mm |
| 020122H | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 450 - 525mm |
| 020122I | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 600 - 675mm |
| 020122J | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 700 - 750 mm |
| 020122K | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 800 mm |
| 020122L | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 900 mm |
| 020122M | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 1000 - 1100mm |
| 020122N | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 1200 mm |
| 020122O | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 1350 - 1400mm |
| 020123A | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 80 mm & under |
| 020123B | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 100 mm |
| 020123C | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 125 -150 mm |
| 020123D | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 200 mm |
| 020123E | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 250 mm |
| 020123F | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 300 - 350 mm |
| 020123G | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 400 mm |
| 020123H | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 450 - 525mm |
| 020123I | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 600 - 675mm |
| 020123J | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 700 - 750 mm |
| 020123K | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 800 mm |
| 020123L | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 900 mm |
| 020123M | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 1000 - 1100mm |
| 020123N | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 1200 mm |
| 020123O | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 1350 - 1400mm |
| 020124A | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 80 mm & under |
| 020124B | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 100 mm |
| 020124C | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 125 -150 mm |
| 020124D | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 200 mm |
| 020124E | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 250 mm |
| 020124F | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 300 - 350 mm |
| 020124G | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 400 mm |
| 020124H | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 450 - 525mm |
| 020124I | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 600 - 675mm |
| 020124J | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 700 - 750 mm |
| 020124K | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 800 mm |
| 020124L | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 900 mm |
| 020124M | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 1000 - 1100mm |
| 020124N | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 1200 mm |
| 020124O | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 1350 - 1400mm |
| 020125B | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 100 mm |
| 020125C | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 125 -150 mm |
| 020125D | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 200 mm |
| 020125E | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 250 mm |
| 020125F | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 300 - 350 mm |
| 020125G | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 400 mm |
| 020125H | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 450 - 525mm |
| 020125I | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 600 - 675mm |
| 020125J | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 700 - 750 mm |
| 020125K | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 800 mm |
| 020125L | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 900 mm |
| 020125M | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 1000 - 1100mm |
| 020125N | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 1200 mm |
| 020125O | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 1350 - 1400mm |
| 020126B | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 100 mm |
| 020126C | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 125 -150 mm |
| 020126D | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 200 mm |
| 020126E | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 250 mm |
| 020126F | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 300 - 350 mm |
| 020126G | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 400 mm |
| 020126H | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 450 - 525mm |
| 020126I | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 600 - 675mm |
| 020126J | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 700 - 750 mm |
| 020126K | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 800 mm |
| 020126L | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 900 mm |
| 020126M | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 1000 - 1100mm |
| 020126N | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 1200 mm |
| 020126O | (A) Cast Iron/Ductile Iron Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 1350 - 1400mm |
| 020127A | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 80 mm & under |
| 020127B | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 100 mm |
| 020127C | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 125 -150 mm |
| 020127D | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 200 mm |
| 020127E | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 250 mm |
| 020127F | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 300 - 350 mm |
| 020127G | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 400 mm |
| 020127H | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 450 - 525mm |
| 020127I | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 600 - 675mm |
| 020127J | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 700 - 750 mm |
| 020127K | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 800 mm |
| 020127L | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 900 mm |
| 020127M | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 1000 - 1100mm |
| 020127N | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 1200 mm |
| 020127O | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 1350 - 1400mm |
| 020127P | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 1600 mm |
| 020127Q | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 1800 mm |
| 020127R | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 1950 - 2100 mm |
| 020127S | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe >2100 mm |
| 020128A | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 80 mm & under |
| 020128B | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 100 mm |
| 020128C | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 125 -150 mm |
| 020128D | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 200 mm |
| 020128E | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 250 mm |
| 020128F | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 300 - 350 mm |
| 020128G | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 400 mm |
| 020128H | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 450 - 525mm |
| 020128I | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 600 - 675mm |
| 020128J | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 700 - 750 mm |
| 020128K | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 800 mm |
| 020128L | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 900 mm |
| 020128M | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 1000 - 1100mm |
| 020128N | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 1200 mm |
| 020128O | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 1350 - 1400mm |
| 020128P | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 1600 mm |
| 020128Q | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 1800 mm |
| 020128R | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 1950 - 2100 mm |
| 020128S | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe >2100 mm |
| 020129A | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 80 mm & under |
| 020129B | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 100 mm |
| 020129C | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 125 -150 mm |
| 020129D | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 200 mm |
| 020129E | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 250 mm |
| 020129F | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 300 - 350 mm |
| 020129G | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 400 mm |
| 020129H | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 450 - 525mm |
| 020129I | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 600 - 675mm |
| 020129J | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 700 - 750 mm |
| 020129K | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 800 mm |
| 020129L | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 900 mm |
| 020129M | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 1000 - 1100mm |
| 020129N | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 1200 mm |
| 020129O | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 1350 - 1400mm |
| 020129P | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 1600 mm |
| 020129Q | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 1800 mm |
| 020129R | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 1950 - 2100 mm |
| 020129S | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe >2100 mm |
| 020130A | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 80 mm & under |
| 020130B | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 100 mm |
| 020130C | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 125 -150 mm |
| 020130D | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 200 mm |
| 020130E | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 250 mm |
| 020130F | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 300 - 350 mm |
| 020130G | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 400 mm |
| 020130H | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 450 - 525mm |
| 020130I | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 600 - 675mm |
| 020130J | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 700 - 750 mm |
| 020130K | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 800 mm |
| 020130L | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 900 mm |
| 020130M | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 1000 - 1100mm |
| 020130N | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 1200 mm |
| 020130O | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 1350 - 1400mm |
| 020130P | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 1600 mm |
| 020130Q | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 1800 mm |
| 020130R | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 1950 - 2100 mm |
| 020130S | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe >2100 mm |
| 020131B | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 100 mm |
| 020131C | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 125 -150 mm |
| 020131D | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 200 mm |
| 020131E | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 250 mm |
| 020131F | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 300 - 350 mm |
| 020131G | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 400 mm |
| 020131H | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 450 - 525mm |
| 020131I | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 600 - 675mm |
| 020131J | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 700 - 750 mm |
| 020131K | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 800 mm |
| 020131L | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 900 mm |
| 020131M | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 1000 - 1100mm |
| 020131N | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 1200 mm |
| 020131O | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 1350 - 1400mm |
| 020131P | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 1600 mm |
| 020131Q | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 1800 mm |
| 020131R | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 1950 - 2100 mm |
| 020131S | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe >2100 mm |
| 020132B | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 100 mm |
| 020132C | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 125 -150 mm |
| 020132D | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 200 mm |
| 020132E | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 250 mm |
| 020132F | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 300 - 350 mm |
| 020132G | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 400 mm |
| 020132H | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 450 - 525mm |
| 020132I | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 600 - 675mm |
| 020132J | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 700 - 750 mm |
| 020132K | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 800 mm |
| 020132L | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 900 mm |
| 020132M | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 1000 - 1100mm |
| 020132N | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 1200 mm |
| 020132O | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 1350 - 1400mm |
| 020132P | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 1600 mm |
| 020132Q | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 1800 mm |
| 020132R | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 1950 - 2100 mm |
| 020132S | (B) Bitumen Lined Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe >2100 mm |
| 020133A | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 80 mm & under |
| 020133B | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 100 mm |
| 020133C | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 125 -150 mm |
| 020133D | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 200 mm |
| 020133E | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 250 mm |
| 020133F | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 300 - 350 mm |
| 020133G | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 400 mm |
| 020133H | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 450 - 525mm |
| 020133I | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 600 - 675mm |
| 020133J | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 700 - 750 mm |
| 020133K | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 800 mm |
| 020133L | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 900 mm |
| 020133M | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 1000 - 1100mm |
| 020133N | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 1200 mm |
| 020133O | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 1350 - 1400mm |
| 020133P | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 1600 mm |
| 020134A | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 80 mm & under |
| 020134B | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 100 mm |
| 020134C | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 125 -150 mm |
| 020134D | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 200 mm |
| 020134E | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 250 mm |
| 020134F | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 300 - 350 mm |
| 020134G | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 400 mm |
| 020134H | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 450 - 525mm |
| 020134I | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 600 - 675mm |
| 020134J | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 700 - 750 mm |
| 020134K | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 800 mm |
| 020134L | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 900 mm |
| 020134M | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 1000 - 1100mm |
| 020134N | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 1200 mm |
| 020134O | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 1350 - 1400mm |
| 020134P | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 1600 mm |
| 020135A | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 80 mm & under |
| 020135B | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 100 mm |
| 020135C | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 125 -150 mm |
| 020135D | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 200 mm |
| 020135E | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 250 mm |
| 020135F | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 300 - 350 mm |
| 020135G | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 400 mm |
| 020135H | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 450 - 525mm |
| 020135I | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 600 - 675mm |
| 020135J | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 700 - 750 mm |
| 020135K | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 800 mm |
| 020135L | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 900 mm |
| 020135M | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 1000 - 1100mm |
| 020135N | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 1200 mm |
| 020135O | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 1350 - 1400mm |
| 020135P | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 1600 mm |
| 020136A | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 80 mm & under |
| 020136B | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 100 mm |
| 020136C | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 125 -150 mm |
| 020136D | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 200 mm |
| 020136E | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 250 mm |
| 020136F | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 300 - 350 mm |
| 020136G | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 400 mm |
| 020136H | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 450 - 525mm |
| 020136I | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 600 - 675mm |
| 020136J | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 700 - 750 mm |
| 020136K | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 800 mm |
| 020136L | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 900 mm |
| 020136M | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 1000 - 1100mm |
| 020136N | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 1200 mm |
| 020136O | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 1350 - 1400mm |
| 020136P | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 1600 mm |
| 020137B | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 100 mm |
| 020137C | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 125 -150 mm |
| 020137D | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 200 mm |
| 020137E | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 250 mm |
| 020137F | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 300 - 350 mm |
| 020137G | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 400 mm |
| 020137H | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 450 - 525mm |
| 020137I | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 600 - 675mm |
| 020137J | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 700 - 750 mm |
| 020137K | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 800 mm |
| 020137L | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 900 mm |
| 020137M | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 1000 - 1100mm |
| 020137N | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 1200 mm |
| 020137O | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 1350 - 1400mm |
| 020137P | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 1600 mm |
| 020138B | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 100 mm |
| 020138C | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 125 -150 mm |
| 020138D | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 200 mm |
| 020138E | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 250 mm |
| 020138F | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 300 - 350 mm |
| 020138G | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 400 mm |
| 020138H | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 450 - 525mm |
| 020138I | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 600 - 675mm |
| 020138J | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 700 - 750 mm |
| 020138K | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 800 mm |
| 020138L | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 900 mm |
| 020138M | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 1000 - 1100mm |
| 020138N | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 1200 mm |
| 020138O | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 1350 - 1400mm |
| 020138P | (C) Concrete Lined/Epoxy Coated Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 1600 mm |
| 020139A | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 15 mm |
| 020139B | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 20 mm |
| 020139C | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 25 mm |
| 020139D | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 40 mm |
| 020139E | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 50 mm |
| 020139F | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 80 mm |
| 020139G | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 100 mm |
| 020139H | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 150 mm |
| 020139I | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 200 mm |
| 020139J | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 250 mm |
| 020140A | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 15 mm |
| 020140B | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 20 mm |
| 020140C | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 25 mm |
| 020140D | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 40 mm |
| 020140E | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 50 mm |
| 020140F | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 80 mm |
| 020140G | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 100 mm |
| 020140H | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 150 mm |
| 020140I | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 200 mm |
| 020140J | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 250 mm |
| 020141A | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 15 mm |
| 020141B | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 20 mm |
| 020141C | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 25 mm |
| 020141D | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 40 mm |
| 020141E | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 50 mm |
| 020141F | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 80 mm |
| 020141G | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 100 mm |
| 020141H | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 150 mm |
| 020141I | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 200 mm |
| 020141J | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 250 mm |
| 020142A | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 15 mm |
| 020142B | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 20 mm |
| 020142C | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 25 mm |
| 020142D | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 40 mm |
| 020142E | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 50 mm |
| 020142F | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 80 mm |
| 020142G | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 100 mm |
| 020142H | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 150 mm |
| 020142I | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 200 mm |
| 020142J | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 250 mm |
| 020143G | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 100 mm |
| 020143H | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 150 mm |
| 020143I | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 200 mm |
| 020143J | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 250 mm |
| 020144G | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 100 mm |
| 020144H | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 150 mm |
| 020144I | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 200 mm |
| 020144J | (D) UPVC Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 250 mm |
| 020145A | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 15 mm |
| 020145B | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 20 mm |
| 020145C | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 25 mm |
| 020145D | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 40 mm |
| 020145E | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 50 mm |
| 020145F | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 80 mm |
| 020145G | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 100 mm |
| 020145H | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 150 mm |
| 020146A | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 15 mm |
| 020146B | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 20 mm |
| 020146C | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 25 mm |
| 020146D | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 40 mm |
| 020146E | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 50 mm |
| 020146F | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 80 mm |
| 020146G | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 100 mm |
| 020146H | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 150 mm |
| 020147A | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 15 mm |
| 020147B | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 20 mm |
| 020147C | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 25 mm |
| 020147D | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 40 mm |
| 020147E | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 50 mm |
| 020147F | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 80 mm |
| 020147G | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 100 mm |
| 020147H | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 150 mm |
| 020148A | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 15 mm |
| 020148B | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 20 mm |
| 020148C | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 25 mm |
| 020148D | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 40 mm |
| 020148E | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 50 mm |
| 020148F | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 80 mm |
| 020148G | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 100 mm |
| 020148H | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 150 mm |
| 020149G | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 100 mm |
| 020149H | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 150 mm |
| 020150G | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 100 mm |
| 020150H | (E) Lined G.I. Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 150 mm |
| 020151A | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 15 mm |
| 020151B | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 20 mm |
| 020151C | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 25 mm |
| 020151D | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 40 mm |
| 020151E | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 50 mm |
| 020151F | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 80 mm |
| 020151G | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 100 mm |
| 020151H | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 150 mm |
| 020151I | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 200 mm |
| 020151J | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 250 mm |
| 020152A | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 15 mm |
| 020152B | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 20 mm |
| 020152C | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 25 mm |
| 020152D | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 40 mm |
| 020152E | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 50 mm |
| 020152F | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 80 mm |
| 020152G | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 100 mm |
| 020152H | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 150 mm |
| 020152I | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 200 mm |
| 020152J | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 250 mm |
| 020153A | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 15 mm |
| 020153B | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 20 mm |
| 020153C | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 25 mm |
| 020153D | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 40 mm |
| 020153E | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 50 mm |
| 020153F | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 80 mm |
| 020153G | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 100 mm |
| 020153H | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 150 mm |
| 020153I | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 200 mm |
| 020153J | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=2.5, T=3.5 Nominal diameter of pipe 250 mm |
| 020154A | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 15 mm |
| 020154B | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 20 mm |
| 020154C | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 25 mm |
| 020154D | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 40 mm |
| 020154E | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 50 mm |
| 020154F | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 80 mm |
| 020154G | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 100 mm |
| 020154H | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 150 mm |
| 020154I | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 200 mm |
| 020154J | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=3.5, T=4.5 Nominal diameter of pipe 250 mm |
| 020155G | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 100 mm |
| 020155H | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 150 mm |
| 020155I | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 200 mm |
| 020155J | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=4.5, T=5.5 Nominal diameter of pipe 250 mm |
| 020156G | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 100 mm |
| 020156H | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 150 mm |
| 020156I | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 200 mm |
| 020156J | (F) PE Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=5.5, T=6.5 Nominal diameter of pipe 250 mm |
| 020157A | (G) Stainless Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 15 mm |
| 020157B | (G) Stainless Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 20 mm |
| 020157C | (G) Stainless Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 25 mm |
| 020157D | (G) Stainless Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 40 mm |
| 020157E | (G) Stainless Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 50 mm |
| 020157F | (G) Stainless Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 80 mm |
| 020157G | (G) Stainless Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 100 mm |
| 020157H | (G) Stainless Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 150 mm |
| 020157I | (G) Stainless Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=0, T=1.5 Nominal diameter of pipe 200 mm |
| 020158AA | Extra over Item Nos. 020/007 to 020/158 for backfilling pipes in trench with sand |
| 020158BB | Extra over Item Nos. 020/007 to 020/158 for backfilling pipes in trench with granular sub-base |
| 020158A | (G) Stainless Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 15 mm |
| 020158B | (G) Stainless Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 20 mm |
| 020158C | (G) Stainless Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 25 mm |
| 020158D | (G) Stainless Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 40 mm |
| 020158E | (G) Stainless Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 50 mm |
| 020158F | (G) Stainless Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 80 mm |
| 020158G | (G) Stainless Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 100 mm |
| 020158H | (G) Stainless Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 150 mm |
| 020158I | (G) Stainless Steel Pipes in trench with concrete surround (Type 4), backfilling above a level of 300 mm above top of pipe (Method Specification) S=1.5, T=2.5 Nominal diameter of pipe 200 mm |
| 020159A | Extra over Item Nos. 020/001 to 020/158 for : Sluice, gate, reflux, air valve or flowmeter. Nominal diameter of valves and pipe fittings 80 mm & under |
| 020159B | Extra over Item Nos. 020/001 to 020/158 for : Sluice, gate, reflux, air valve or flowmeter. Nominal diameter of valves and pipe fittings 100 mm |
| 020159C | Extra over Item Nos. 020/001 to 020/158 for : Sluice, gate, reflux, air valve or flowmeter. Nominal diameter of valves and pipe fittings 125 -150 mm |
| 020159D | Extra over Item Nos. 020/001 to 020/158 for : Sluice, gate, reflux, air valve or flowmeter. Nominal diameter of valves and pipe fittings 200 mm |
| 020159E | Extra over Item Nos. 020/001 to 020/158 for : Sluice, gate, reflux, air valve or flowmeter. Nominal diameter of valves and pipe fittings 250 mm |
| 020159F | Extra over Item Nos. 020/001 to 020/158 for : Sluice, gate, reflux, air valve or flowmeter. Nominal diameter of valves and pipe fittings 300 - 350 mm |
| 020159G | Extra over Item Nos. 020/001 to 020/158 for : Sluice, gate, reflux, air valve or flowmeter. Nominal diameter of valves and pipe fittings 400 mm |
| 020159H | Extra over Item Nos. 020/001 to 020/158 for : Sluice, gate, reflux, air valve or flowmeter. Nominal diameter of valves and pipe fittings 450 - 525mm |
| 020159I | Extra over Item Nos. 020/001 to 020/158 for : Sluice, gate, reflux, air valve or flowmeter. Nominal diameter of valves and pipe fittings 600 - 675mm |
| 020159J | Extra over Item Nos. 020/001 to 020/158 for : Sluice, gate, reflux, air valve or flowmeter. Nominal diameter of valves and pipe fittings 700 - 750 mm |
| 020159K | Extra over Item Nos. 020/001 to 020/158 for : Sluice, gate, reflux, air valve or flowmeter. Nominal diameter of valves and pipe fittings 800 mm |
| 020159L | Extra over Item Nos. 020/001 to 020/158 for : Sluice, gate, reflux, air valve or flowmeter. Nominal diameter of valves and pipe fittings 900 mm |
| 020159M | Extra over Item Nos. 020/001 to 020/158 for : Sluice, gate, reflux, air valve or flowmeter. Nominal diameter of valves and pipe fittings 1000 - 1100mm |
| 020159N | Extra over Item Nos. 020/001 to 020/158 for : Sluice, gate, reflux, air valve or flowmeter. Nominal diameter of valves and pipe fittings 1200 mm |
| 020159O | Extra over Item Nos. 020/001 to 020/158 for : Sluice, gate, reflux, air valve or flowmeter. Nominal diameter of valves and pipe fittings 1350 - 1400mm |
| 020159P | Extra over Item Nos. 020/001 to 020/158 for : Sluice, gate, reflux, air valve or flowmeter. Nominal diameter of valves and pipe fittings 1600 mm |
| 020159Q | Extra over Item Nos. 020/001 to 020/158 for : Sluice, gate, reflux, air valve or flowmeter. Nominal diameter of valves and pipe fittings 1800 mm |
| 020159R | Extra over Item Nos. 020/001 to 020/158 for : Sluice, gate, reflux, air valve or flowmeter. Nominal diameter of valves and pipe fittings 1950 - 2100mm |
| 020159S | Extra over Item Nos. 020/001 to 020/158 for : Sluice, gate, reflux, air valve or flowmeter. Nominal diameter of valves and pipe fittings >2100 mm |
| 020160A | Extra over Item Nos. 020/001 to 020/158 for : Tee, angle branch or taper connection to steel pipe. Nominal diameter of valves and pipe fittings 80 mm & under |
| 020160B | Extra over Item Nos. 020/001 to 020/158 for : Tee, angle branch or taper connection to steel pipe. Nominal diameter of valves and pipe fittings 100 mm |
| 020160C | Extra over Item Nos. 020/001 to 020/158 for : Tee, angle branch or taper connection to steel pipe. Nominal diameter of valves and pipe fittings 125 -150 mm |
| 020160D | Extra over Item Nos. 020/001 to 020/158 for : Tee, angle branch or taper connection to steel pipe. Nominal diameter of valves and pipe fittings 200 mm |
| 020160E | Extra over Item Nos. 020/001 to 020/158 for : Tee, angle branch or taper connection to steel pipe. Nominal diameter of valves and pipe fittings 250 mm |
| 020160F | Extra over Item Nos. 020/001 to 020/158 for : Tee, angle branch or taper connection to steel pipe. Nominal diameter of valves and pipe fittings 300 - 350 mm |
| 020160G | Extra over Item Nos. 020/001 to 020/158 for : Tee, angle branch or taper connection to steel pipe. Nominal diameter of valves and pipe fittings 400 mm |
| 020160H | Extra over Item Nos. 020/001 to 020/158 for : Tee, angle branch or taper connection to steel pipe. Nominal diameter of valves and pipe fittings 450 - 525mm |
| 020160I | Extra over Item Nos. 020/001 to 020/158 for : Tee, angle branch or taper connection to steel pipe. Nominal diameter of valves and pipe fittings 600 - 675mm |
| 020160J | Extra over Item Nos. 020/001 to 020/158 for : Tee, angle branch or taper connection to steel pipe. Nominal diameter of valves and pipe fittings 700 - 750 mm |
| 020160K | Extra over Item Nos. 020/001 to 020/158 for : Tee, angle branch or taper connection to steel pipe. Nominal diameter of valves and pipe fittings 800 mm |
| 020160L | Extra over Item Nos. 020/001 to 020/158 for : Tee, angle branch or taper connection to steel pipe. Nominal diameter of valves and pipe fittings 900 mm |
| 020160M | Extra over Item Nos. 020/001 to 020/158 for : Tee, angle branch or taper connection to steel pipe. Nominal diameter of valves and pipe fittings 1000 - 1100mm |
| 020160N | Extra over Item Nos. 020/001 to 020/158 for : Tee, angle branch or taper connection to steel pipe. Nominal diameter of valves and pipe fittings 1200 mm |
| 020160O | Extra over Item Nos. 020/001 to 020/158 for : Tee, angle branch or taper connection to steel pipe. Nominal diameter of valves and pipe fittings 1350 - 1400mm |
| 020160P | Extra over Item Nos. 020/001 to 020/158 for : Tee, angle branch or taper connection to steel pipe. Nominal diameter of valves and pipe fittings 1600 mm |
| 020160Q | Extra over Item Nos. 020/001 to 020/158 for : Tee, angle branch or taper connection to steel pipe. Nominal diameter of valves and pipe fittings 1800 mm |
| 020160R | Extra over Item Nos. 020/001 to 020/158 for : Tee, angle branch or taper connection to steel pipe. Nominal diameter of valves and pipe fittings 1950 - 2100mm |
| 020160S | Extra over Item Nos. 020/001 to 020/158 for : Tee, angle branch or taper connection to steel pipe. Nominal diameter of valves and pipe fittings >2100 mm |
| 020161A | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 6 degree and up to 30 degree. Nominal diameter of valves and pipe fittings 80 mm & under |
| 020161B | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 6 degree and up to 30 degree. Nominal diameter of valves and pipe fittings 100 mm |
| 020161C | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 6 degree and up to 30 degree. Nominal diameter of valves and pipe fittings 125 -150 mm |
| 020161D | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 6 degree and up to 30 degree. Nominal diameter of valves and pipe fittings 200 mm |
| 020161E | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 6 degree and up to 30 degree. Nominal diameter of valves and pipe fittings 250 mm |
| 020161F | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 6 degree and up to 30 degree. Nominal diameter of valves and pipe fittings 300 - 350 mm |
| 020161G | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 6 degree and up to 30 degree. Nominal diameter of valves and pipe fittings 400 mm |
| 020161H | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 6 degree and up to 30 degree. Nominal diameter of valves and pipe fittings 450 - 525mm |
| 020161I | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 6 degree and up to 30 degree. Nominal diameter of valves and pipe fittings 600 - 675mm |
| 020161J | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 6 degree and up to 30 degree. Nominal diameter of valves and pipe fittings 700 - 750 mm |
| 020161K | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 6 degree and up to 30 degree. Nominal diameter of valves and pipe fittings 800 mm |
| 020161L | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 6 degree and up to 30 degree. Nominal diameter of valves and pipe fittings 900 mm |
| 020161M | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 6 degree and up to 30 degree. Nominal diameter of valves and pipe fittings 1000 - 1100mm |
| 020161N | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 6 degree and up to 30 degree. Nominal diameter of valves and pipe fittings 1200 mm |
| 020161O | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 6 degree and up to 30 degree. Nominal diameter of valves and pipe fittings 1350 - 1400mm |
| 020161P | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 6 degree and up to 30 degree. Nominal diameter of valves and pipe fittings 1600 mm |
| 020161Q | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 6 degree and up to 30 degree. Nominal diameter of valves and pipe fittings 1800 mm |
| 020161R | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 6 degree and up to 30 degree. Nominal diameter of valves and pipe fittings 1950 - 2100mm |
| 020161S | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 6 degree and up to 30 degree. Nominal diameter of valves and pipe fittings >2100 mm |
| 020162A | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 30 degree and up to 45 degree. Nominal diameter of valves and pipe fittings 80 mm & under |
| 020162B | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 30 degree and up to 45 degree. Nominal diameter of valves and pipe fittings 100 mm |
| 020162C | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 30 degree and up to 45 degree. Nominal diameter of valves and pipe fittings 125 -150 mm |
| 020162D | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 30 degree and up to 45 degree. Nominal diameter of valves and pipe fittings 200 mm |
| 020162E | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 30 degree and up to 45 degree. Nominal diameter of valves and pipe fittings 250 mm |
| 020162F | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 30 degree and up to 45 degree. Nominal diameter of valves and pipe fittings 300 - 350 mm |
| 020162G | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 30 degree and up to 45 degree. Nominal diameter of valves and pipe fittings 400 mm2 |
| 020162H | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 30 degree and up to 45 degree. Nominal diameter of valves and pipe fittings 450 - 525mm |
| 020162I | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 30 degree and up to 45 degree. Nominal diameter of valves and pipe fittings 600 - 675mm |
| 020162J | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 30 degree and up to 45 degree. Nominal diameter of valves and pipe fittings 700 - 750 mm |
| 020162K | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 30 degree and up to 45 degree. Nominal diameter of valves and pipe fittings 800 mm |
| 020162L | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 30 degree and up to 45 degree. Nominal diameter of valves and pipe fittings 900 mm |
| 020162M | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 30 degree and up to 45 degree. Nominal diameter of valves and pipe fittings 1000 - 1100mm |
| 020162N | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 30 degree and up to 45 degree. Nominal diameter of valves and pipe fittings 1200 mm |
| 020162O | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 30 degree and up to 45 degree. Nominal diameter of valves and pipe fittings 1350 - 1400mm |
| 020162P | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 30 degree and up to 45 degree. Nominal diameter of valves and pipe fittings 1600 mm |
| 020162Q | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 30 degree and up to 45 degree. Nominal diameter of valves and pipe fittings 1800 mm |
| 020162R | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 30 degree and up to 45 degree. Nominal diameter of valves and pipe fittings 1950 - 2100mm |
| 020162S | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 30 degree and up to 45 degree. Nominal diameter of valves and pipe fittings >2100 mm |
| 020163A | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 45 degree and up to 60 degree. Nominal diameter of valves and pipe fittings 80 mm & under |
| 020163B | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 45 degree and up to 60 degree. Nominal diameter of valves and pipe fittings 100 mm |
| 020163C | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 45 degree and up to 60 degree. Nominal diameter of valves and pipe fittings 125 -150 mm |
| 020163D | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 45 degree and up to 60 degree. Nominal diameter of valves and pipe fittings 200 mm |
| 020163E | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 45 degree and up to 60 degree. Nominal diameter of valves and pipe fittings 250 mm |
| 020163F | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 45 degree and up to 60 degree. Nominal diameter of valves and pipe fittings 300 - 350 mm |
| 020163G | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 45 degree and up to 60 degree. Nominal diameter of valves and pipe fittings 400 mm |
| 020163H | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 45 degree and up to 60 degree. Nominal diameter of valves and pipe fittings 450 - 525mm |
| 020163I | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 45 degree and up to 60 degree. Nominal diameter of valves and pipe fittings 600 - 675mm |
| 020163J | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 45 degree and up to 60 degree. Nominal diameter of valves and pipe fittings 700 - 750 mm |
| 020163K | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 45 degree and up to 60 degree. Nominal diameter of valves and pipe fittings 800 mm |
| 020163L | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 45 degree and up to 60 degree. Nominal diameter of valves and pipe fittings 900 mm |
| 020163M | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 45 degree and up to 60 degree. Nominal diameter of valves and pipe fittings 1000 - 1100mm |
| 020163N | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 45 degree and up to 60 degree. Nominal diameter of valves and pipe fittings 1200 mm |
| 020163O | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 45 degree and up to 60 degree. Nominal diameter of valves and pipe fittings 1350 - 1400mm |
| 020163P | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 45 degree and up to 60 degree. Nominal diameter of valves and pipe fittings 1600 mm |
| 020163Q | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 45 degree and up to 60 degree. Nominal diameter of valves and pipe fittings 1800 mm |
| 020163R | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 45 degree and up to 60 degree. Nominal diameter of valves and pipe fittings 1950 - 2100mm |
| 020163S | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 45 degree and up to 60 degree. Nominal diameter of valves and pipe fittings >2100 mm |
| 020164A | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 60 degree and up to 90 degree. Nominal diameter of valves and pipe fittings 80 mm & under |
| 020164B | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 60 degree and up to 90 degree. Nominal diameter of valves and pipe fittings 100 mm |
| 020164C | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 60 degree and up to 90 degree. Nominal diameter of valves and pipe fittings 125 -150 mm |
| 020164D | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 60 degree and up to 90 degree. Nominal diameter of valves and pipe fittings 200 mm |
| 020164E | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 60 degree and up to 90 degree. Nominal diameter of valves and pipe fittings 250 mm |
| 020164F | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 60 degree and up to 90 degree. Nominal diameter of valves and pipe fittings 300 - 350 mm |
| 020164G | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 60 degree and up to 90 degree. Nominal diameter of valves and pipe fittings 400 mm |
| 020164H | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 60 degree and up to 90 degree. Nominal diameter of valves and pipe fittings 450 - 525mm |
| 020164I | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 60 degree and up to 90 degree. Nominal diameter of valves and pipe fittings 600 - 675mm |
| 020164J | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 60 degree and up to 90 degree. Nominal diameter of valves and pipe fittings 700 - 750 mm |
| 020164K | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 60 degree and up to 90 degree. Nominal diameter of valves and pipe fittings 800 mm |
| 020164L | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 60 degree and up to 90 degree. Nominal diameter of valves and pipe fittings 900 mm |
| 020164M | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 60 degree and up to 90 degree. Nominal diameter of valves and pipe fittings 1000 - 1100mm |
| 020164N | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 60 degree and up to 90 degree. Nominal diameter of valves and pipe fittings 1200 mm |
| 020164O | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 60 degree and up to 90 degree. Nominal diameter of valves and pipe fittings 1350 - 1400mm |
| 020164P | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 60 degree and up to 90 degree. Nominal diameter of valves and pipe fittings 1600 mm |
| 020164Q | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 60 degree and up to 90 degree. Nominal diameter of valves and pipe fittings 1800 mm |
| 020164R | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 60 degree and up to 90 degree. Nominal diameter of valves and pipe fittings 1950 - 2100mm |
| 020164S | Extra over Item Nos. 020/001 to 020/158 for : Steel pipe gussetted bend over 60 degree and up to 90 degree. Nominal diameter of valves and pipe fittings >2100 mm |
| 020165A | Extra over Item Nos. 020/001 to 020/158 for : Weld ring flange to steel pipe. Nominal diameter of valves and pipe fittings 80 mm & under |
| 020165B | Extra over Item Nos. 020/001 to 020/158 for : Weld ring flange to steel pipe. Nominal diameter of valves and pipe fittings 100 mm |
| 020165C | Extra over Item Nos. 020/001 to 020/158 for : Weld ring flange to steel pipe. Nominal diameter of valves and pipe fittings 125 -150 mm |
| 020165D | Extra over Item Nos. 020/001 to 020/158 for : Weld ring flange to steel pipe. Nominal diameter of valves and pipe fittings 200 mm |
| 020165E | Extra over Item Nos. 020/001 to 020/158 for : Weld ring flange to steel pipe. Nominal diameter of valves and pipe fittings 250 mm |
| 020165F | Extra over Item Nos. 020/001 to 020/158 for : Weld ring flange to steel pipe. Nominal diameter of valves and pipe fittings 300 - 350 mm |
| 020165G | Extra over Item Nos. 020/001 to 020/158 for : Weld ring flange to steel pipe. Nominal diameter of valves and pipe fittings 400 mm |
| 020165H | Extra over Item Nos. 020/001 to 020/158 for : Weld ring flange to steel pipe. Nominal diameter of valves and pipe fittings 450 - 525mm |
| 020165I | Extra over Item Nos. 020/001 to 020/158 for : Weld ring flange to steel pipe. Nominal diameter of valves and pipe fittings 600 - 675mm |
| 020165J | Extra over Item Nos. 020/001 to 020/158 for : Weld ring flange to steel pipe. Nominal diameter of valves and pipe fittings 700 - 750 mm |
| 020165K | Extra over Item Nos. 020/001 to 020/158 for : Weld ring flange to steel pipe. Nominal diameter of valves and pipe fittings 800 mm |
| 020165L | Extra over Item Nos. 020/001 to 020/158 for : Weld ring flange to steel pipe. Nominal diameter of valves and pipe fittings 900 mm |
| 020165M | Extra over Item Nos. 020/001 to 020/158 for : Weld ring flange to steel pipe. Nominal diameter of valves and pipe fittings 1000 - 1100mm |
| 020165N | Extra over Item Nos. 020/001 to 020/158 for : Weld ring flange to steel pipe. Nominal diameter of valves and pipe fittings 1200 mm |
| 020165O | Extra over Item Nos. 020/001 to 020/158 for : Weld ring flange to steel pipe. Nominal diameter of valves and pipe fittings 1350 - 1400mm |
| 020165P | Extra over Item Nos. 020/001 to 020/158 for : Weld ring flange to steel pipe. Nominal diameter of valves and pipe fittings 1600 mm |
| 020165Q | Extra over Item Nos. 020/001 to 020/158 for : Weld ring flange to steel pipe. Nominal diameter of valves and pipe fittings 1800 mm |
| 020165R | Extra over Item Nos. 020/001 to 020/158 for : Weld ring flange to steel pipe. Nominal diameter of valves and pipe fittings 1950 - 2100mm |
| 020165S | Extra over Item Nos. 020/001 to 020/158 for : Weld ring flange to steel pipe. Nominal diameter of valves and pipe fittings >2100 mm |
| 020166F | Extra over Item Nos. 020/001 to 020/158 for : Ball valve. Nominal diameter of valves and pipe fittings 80 mm |
| 020166G | Extra over Item Nos. 020/001 to 020/158 for : Ball valve. Nominal diameter of valves and pipe fittings 100 mm |
| 020166H | Extra over Item Nos. 020/001 to 020/158 for : Ball valve. Nominal diameter of valves and pipe fittings 150 mm |
| 020167A | Extra over Item Nos. 020/001 to 020/158 for : U.P.V.C. pipe sockets. Nominal diameter of valves and pipe fittings 15 mm |
| 020167B | Extra over Item Nos. 020/001 to 020/158 for : U.P.V.C. pipe sockets. Nominal diameter of valves and pipe fittings 20 mm |
| 020167C | Extra over Item Nos. 020/001 to 020/158 for : U.P.V.C. pipe sockets. Nominal diameter of valves and pipe fittings 25 mm |
| 020167D | Extra over Item Nos. 020/001 to 020/158 for : U.P.V.C. pipe sockets. Nominal diameter of valves and pipe fittings 40 mm |
| 020167E | Extra over Item Nos. 020/001 to 020/158 for : U.P.V.C. pipe sockets. Nominal diameter of valves and pipe fittings 50 mm |
| 020167F | Extra over Item Nos. 020/001 to 020/158 for : U.P.V.C. pipe sockets. Nominal diameter of valves and pipe fittings 80 mm |
| 020167G | Extra over Item Nos. 020/001 to 020/158 for : U.P.V.C. pipe sockets. Nominal diameter of valves and pipe fittings 100 mm |
| 020167H | Extra over Item Nos. 020/001 to 020/158 for : U.P.V.C. pipe sockets. Nominal diameter of valves and pipe fittings 150 mm |
| 020167I | Extra over Item Nos. 020/001 to 020/158 for : U.P.V.C. pipe sockets. Nominal diameter of valves and pipe fittings 200 mm |
| 020167J | Extra over Item Nos. 020/001 to 020/158 for : U.P.V.C. pipe sockets. Nominal diameter of valves and pipe fittings 250 mm |
| 020168A | Extra over Item Nos. 020/001 to 020/158 for : U.P.V.C. pipe bends and elbows to any angle. Nominal diameter of valves and pipe fittings 15 mm |
| 020168B | Extra over Item Nos. 020/001 to 020/158 for : U.P.V.C. pipe bends and elbows to any angle. Nominal diameter of valves and pipe fittings 20 mm |
| 020168C | Extra over Item Nos. 020/001 to 020/158 for : U.P.V.C. pipe bends and elbows to any angle. Nominal diameter of valves and pipe fittings 25 mm |
| 020168D | Extra over Item Nos. 020/001 to 020/158 for : U.P.V.C. pipe bends and elbows to any angle. Nominal diameter of valves and pipe fittings 40 mm |
| 020168E | Extra over Item Nos. 020/001 to 020/158 for : U.P.V.C. pipe bends and elbows to any angle. Nominal diameter of valves and pipe fittings 50 mm |
| 020168F | Extra over Item Nos. 020/001 to 020/158 for : U.P.V.C. pipe bends and elbows to any angle. Nominal diameter of valves and pipe fittings 80 mm |
| 020168G | Extra over Item Nos. 020/001 to 020/158 for : U.P.V.C. pipe bends and elbows to any angle. Nominal diameter of valves and pipe fittings 100 mm |
| 020168H | Extra over Item Nos. 020/001 to 020/158 for : U.P.V.C. pipe bends and elbows to any angle. Nominal diameter of valves and pipe fittings 150 mm |
| 020168I | Extra over Item Nos. 020/001 to 020/158 for : U.P.V.C. pipe bends and elbows to any angle. Nominal diameter of valves and pipe fittings 200 mm |
| 020168J | Extra over Item Nos. 020/001 to 020/158 for : U.P.V.C. pipe bends and elbows to any angle. Nominal diameter of valves and pipe fittings 250 mm |
| 020169A | Extra over Item Nos. 020/001 to 020/158 for : Lined G.I. tees or Lined G.I. connectors and nipples. Nominal diameter of valves and pipe fittings 15 mm |
| 020169B | Extra over Item Nos. 020/001 to 020/158 for : Lined G.I. tees or Lined G.I. connectors and nipples. Nominal diameter of valves and pipe fittings 20 mm |
| 020169C | Extra over Item Nos. 020/001 to 020/158 for : Lined G.I. tees or Lined G.I. connectors and nipples. Nominal diameter of valves and pipe fittings 25 mm |
| 020169D | Extra over Item Nos. 020/001 to 020/158 for : Lined G.I. tees or Lined G.I. connectors and nipples. Nominal diameter of valves and pipe fittings 40 mm |
| 020169E | Extra over Item Nos. 020/001 to 020/158 for : Lined G.I. tees or Lined G.I. connectors and nipples. Nominal diameter of valves and pipe fittings 50 mm |
| 020169F | Extra over Item Nos. 020/001 to 020/158 for : Lined G.I. tees or Lined G.I. connectors and nipples. Nominal diameter of valves and pipe fittings 80 mm |
| 020169G | Extra over Item Nos. 020/001 to 020/158 for : Lined G.I. tees or Lined G.I. connectors and nipples. Nominal diameter of valves and pipe fittings 100 mm |
| 020169H | Extra over Item Nos. 020/001 to 020/158 for : Lined G.I. tees or Lined G.I. connectors and nipples. Nominal diameter of valves and pipe fittings 150 mm |
| 020170A | Extra over Item Nos. 020/001 to 020/158 for : Lined G.I. pipe bends and elbows to any angle. Nominal diameter of valves and pipe fittings 15 mm |
| 020170B | Extra over Item Nos. 020/001 to 020/158 for : Lined G.I. pipe bends and elbows to any angle. Nominal diameter of valves and pipe fittings 20 mm |
| 020170C | Extra over Item Nos. 020/001 to 020/158 for : Lined G.I. pipe bends and elbows to any angle. Nominal diameter of valves and pipe fittings 25 mm |
| 020170D | Extra over Item Nos. 020/001 to 020/158 for : Lined G.I. pipe bends and elbows to any angle. Nominal diameter of valves and pipe fittings 40 mm |
| 020170E | Extra over Item Nos. 020/001 to 020/158 for : Lined G.I. pipe bends and elbows to any angle. Nominal diameter of valves and pipe fittings 50 mm |
| 020170F | Extra over Item Nos. 020/001 to 020/158 for : Lined G.I. pipe bends and elbows to any angle. Nominal diameter of valves and pipe fittings 80 mm |
| 020170G | Extra over Item Nos. 020/001 to 020/158 for : Lined G.I. pipe bends and elbows to any angle. Nominal diameter of valves and pipe fittings 100 mm |
| 020170H | Extra over Item Nos. 020/001 to 020/158 for : Lined G.I. pipe bends and elbows to any angle. Nominal diameter of valves and pipe fittings 150 mm |
| 020171A | Extra over Item Nos. 020/001 to 020/158 for : Lined G.I. stop ends, plugs or strainers. Nominal diameter of valves and pipe fittings 15 mm |
| 020171B | Extra over Item Nos. 020/001 to 020/158 for : Lined G.I. stop ends, plugs or strainers. Nominal diameter of valves and pipe fittings 20 mm |
| 020171C | Extra over Item Nos. 020/001 to 020/158 for : Lined G.I. stop ends, plugs or strainers. Nominal diameter of valves and pipe fittings 25 mm |
| 020171D | Extra over Item Nos. 020/001 to 020/158 for : Lined G.I. stop ends, plugs or strainers. Nominal diameter of valves and pipe fittings 40 mm |
| 020171E | Extra over Item Nos. 020/001 to 020/158 for : Lined G.I. stop ends, plugs or strainers. Nominal diameter of valves and pipe fittings 50 mm |
| 020171F | Extra over Item Nos. 020/001 to 020/158 for : Lined G.I. stop ends, plugs or strainers. Nominal diameter of valves and pipe fittings 80 mm |
| 020171G | Extra over Item Nos. 020/001 to 020/158 for : Lined G.I. stop ends, plugs or strainers. Nominal diameter of valves and pipe fittings 100 mm |
| 020171H | Extra over Item Nos. 020/001 to 020/158 for : Lined G.I. stop ends, plugs or strainers. Nominal diameter of valves and pipe fittings 150 mm |
| 020172A | Extra over Item Nos. 020/001 to 020/158 for : Screw jointed valves or stopcocks for Lined G.I. Pipes. Nominal diameter of valves and pipe fittings 15 mm |
| 020172B | Extra over Item Nos. 020/001 to 020/158 for : Screw jointed valves or stopcocks for Lined G.I. Pipes. Nominal diameter of valves and pipe fittings 20 mm |
| 020172C | Extra over Item Nos. 020/001 to 020/158 for : Screw jointed valves or stopcocks for Lined G.I. Pipes. Nominal diameter of valves and pipe fittings 25 mm |
| 020172D | Extra over Item Nos. 020/001 to 020/158 for : Screw jointed valves or stopcocks for Lined G.I. Pipes. Nominal diameter of valves and pipe fittings 40 mm |
| 020172E | Extra over Item Nos. 020/001 to 020/158 for : Screw jointed valves or stopcocks for Lined G.I. Pipes. Nominal diameter of valves and pipe fittings 50 mm |
| 020172F | Extra over Item Nos. 020/001 to 020/158 for : Screw jointed valves or stopcocks for Lined G.I. Pipes. Nominal diameter of valves and pipe fittings 80 mm |
| 020172G | Extra over Item Nos. 020/001 to 020/158 for : Screw jointed valves or stopcocks for Lined G.I. Pipes. Nominal diameter of valves and pipe fittings 100 mm |
| 020173B | Extra over Item Nos. 020/001 to 020/158 for : Lined G.I. sockets, reducing sockets and bushings. Nominal diameter of valves and pipe fittings 20 mm |
| 020173C | Extra over Item Nos. 020/001 to 020/158 for : Lined G.I. sockets, reducing sockets and bushings. Nominal diameter of valves and pipe fittings 25 mm |
| 020173D | Extra over Item Nos. 020/001 to 020/158 for : Lined G.I. sockets, reducing sockets and bushings. Nominal diameter of valves and pipe fittings 40 mm |
| 020173E | Extra over Item Nos. 020/001 to 020/158 for : Lined G.I. sockets, reducing sockets and bushings. Nominal diameter of valves and pipe fittings 50 mm |
| 020173F | Extra over Item Nos. 020/001 to 020/158 for : Lined G.I. sockets, reducing sockets and bushings. Nominal diameter of valves and pipe fittings 80 mm |
| 020173G | Extra over Item Nos. 020/001 to 020/158 for : Lined G.I. sockets, reducing sockets and bushings. Nominal diameter of valves and pipe fittings 100 mm |
| 020173H | Extra over Item Nos. 020/001 to 020/158 for : Lined G.I. sockets, reducing sockets and bushings. Nominal diameter of valves and pipe fittings 150 mm |
| 020174A | Extra over Item Nos. 020/001 to 020/158 for : PE pipe bends and elbows to any angle. Nominal diameter of valves and pipe fittings 15 mm |
| 020174B | Extra over Item Nos. 020/001 to 020/158 for : PE pipe bends and elbows to any angle. Nominal diameter of valves and pipe fittings 20 mm |
| 020174C | Extra over Item Nos. 020/001 to 020/158 for : PE pipe bends and elbows to any angle. Nominal diameter of valves and pipe fittings 25 mm |
| 020174D | Extra over Item Nos. 020/001 to 020/158 for : PE pipe bends and elbows to any angle. Nominal diameter of valves and pipe fittings 40 mm |
| 020174E | Extra over Item Nos. 020/001 to 020/158 for : PE pipe bends and elbows to any angle. Nominal diameter of valves and pipe fittings 50 mm |
| 020174F | Extra over Item Nos. 020/001 to 020/158 for : PE pipe bends and elbows to any angle. Nominal diameter of valves and pipe fittings 80 mm |
| 020174G | Extra over Item Nos. 020/001 to 020/158 for : PE pipe bends and elbows to any angle. Nominal diameter of valves and pipe fittings 100 mm |
| 020174H | Extra over Item Nos. 020/001 to 020/158 for : PE pipe bends and elbows to any angle. Nominal diameter of valves and pipe fittings 150 mm |
| 020174I | Extra over Item Nos. 020/001 to 020/158 for : PE pipe bends and elbows to any angle. Nominal diameter of valves and pipe fittings 200 mm |
| 020174J | Extra over Item Nos. 020/001 to 020/158 for : PE pipe bends and elbows to any angle. Nominal diameter of valves and pipe fittings 250 mm |
| 020175A | Extra over Item Nos. 020/001 to 020/158 for : PE pipe couplers, adaptors or compression couplings. Nominal diameter of valves and pipe fittings 15 mm |
| 020175B | Extra over Item Nos. 020/001 to 020/158 for : PE pipe couplers, adaptors or compression couplings. Nominal diameter of valves and pipe fittings 20 mm |
| 020175C | Extra over Item Nos. 020/001 to 020/158 for : PE pipe couplers, adaptors or compression couplings. Nominal diameter of valves and pipe fittings 25 mm |
| 020175D | Extra over Item Nos. 020/001 to 020/158 for : PE pipe couplers, adaptors or compression couplings. Nominal diameter of valves and pipe fittings 40 mm |
| 020175E | Extra over Item Nos. 020/001 to 020/158 for : PE pipe couplers, adaptors or compression couplings. Nominal diameter of valves and pipe fittings 50 mm |
| 020175F | Extra over Item Nos. 020/001 to 020/158 for : PE pipe couplers, adaptors or compression couplings. Nominal diameter of valves and pipe fittings 80 mm |
| 020175G | Extra over Item Nos. 020/001 to 020/158 for : PE pipe couplers, adaptors or compression couplings. Nominal diameter of valves and pipe fittings 100 mm |
| 020175H | Extra over Item Nos. 020/001 to 020/158 for : PE pipe couplers, adaptors or compression couplings. Nominal diameter of valves and pipe fittings 150 mm |
| 020175I | Extra over Item Nos. 020/001 to 020/158 for : PE pipe couplers, adaptors or compression couplings. Nominal diameter of valves and pipe fittings 200 mm |
| 020175J | Extra over Item Nos. 020/001 to 020/158 for : PE pipe couplers, adaptors or compression couplings. Nominal diameter of valves and pipe fittings 250 mm |
| 020176A | Extra over Item Nos. 020/001 to 020/158 for : PE tees. Nominal diameter of valves and pipe fittings 15 mm |
| 020176B | Extra over Item Nos. 020/001 to 020/158 for : PE tees. Nominal diameter of valves and pipe fittings 20 mm |
| 020176C | Extra over Item Nos. 020/001 to 020/158 for : PE tees. Nominal diameter of valves and pipe fittings 25 mm |
| 020176D | Extra over Item Nos. 020/001 to 020/158 for : PE tees. Nominal diameter of valves and pipe fittings 40 mm |
| 020176E | Extra over Item Nos. 020/001 to 020/158 for : PE tees. Nominal diameter of valves and pipe fittings 50 mm |
| 020176F | Extra over Item Nos. 020/001 to 020/158 for : PE tees. Nominal diameter of valves and pipe fittings 80 mm |
| 020176G | Extra over Item Nos. 020/001 to 020/158 for : PE tees. Nominal diameter of valves and pipe fittings 100 mm |
| 020176H | Extra over Item Nos. 020/001 to 020/158 for : PE tees. Nominal diameter of valves and pipe fittings 150 mm |
| 020176I | Extra over Item Nos. 020/001 to 020/158 for : PE tees. Nominal diameter of valves and pipe fittings 200 mm |
| 020176J | Extra over Item Nos. 020/001 to 020/158 for : PE tees. Nominal diameter of valves and pipe fittings 250 mm |
| 020177A | Extra over Item Nos. 020/001 to 020/158 for : S.S. tees or S.S. connectors and nipples. Nominal diameter of valves and pipe fittings 15 mm |
| 020177B | Extra over Item Nos. 020/001 to 020/158 for : S.S. tees or S.S. connectors and nipples. Nominal diameter of valves and pipe fittings 20 mm |
| 020177C | Extra over Item Nos. 020/001 to 020/158 for : S.S. tees or S.S. connectors and nipples. Nominal diameter of valves and pipe fittings 25 mm |
| 020177D | Extra over Item Nos. 020/001 to 020/158 for : S.S. tees or S.S. connectors and nipples. Nominal diameter of valves and pipe fittings 40 mm |
| 020177E | Extra over Item Nos. 020/001 to 020/158 for : S.S. tees or S.S. connectors and nipples. Nominal diameter of valves and pipe fittings 50 mm |
| 020177F | Extra over Item Nos. 020/001 to 020/158 for : S.S. tees or S.S. connectors and nipples. Nominal diameter of valves and pipe fittings 80 mm |
| 020177G | Extra over Item Nos. 020/001 to 020/158 for : S.S. tees or S.S. connectors and nipples. Nominal diameter of valves and pipe fittings 100 mm |
| 020177H | Extra over Item Nos. 020/001 to 020/158 for : S.S. tees or S.S. connectors and nipples. Nominal diameter of valves and pipe fittings 150 mm |
| 020177I | Extra over Item Nos. 020/001 to 020/158 for : S.S. tees or S.S. connectors and nipples. Nominal diameter of valves and pipe fittings 200 mm |
| 020178A | Extra over Item Nos. 020/001 to 020/158 for : S.S. pipe bends and elbows to any angle. Nominal diameter of valves and pipe fittings 15 mm |
| 020178B | Extra over Item Nos. 020/001 to 020/158 for : S.S. pipe bends and elbows to any angle. Nominal diameter of valves and pipe fittings 20 mm |
| 020178C | Extra over Item Nos. 020/001 to 020/158 for : S.S. pipe bends and elbows to any angle. Nominal diameter of valves and pipe fittings 25 mm |
| 020178D | Extra over Item Nos. 020/001 to 020/158 for : S.S. pipe bends and elbows to any angle. Nominal diameter of valves and pipe fittings 40 mm |
| 020178E | Extra over Item Nos. 020/001 to 020/158 for : S.S. pipe bends and elbows to any angle. Nominal diameter of valves and pipe fittings 50 mm |
| 020178F | Extra over Item Nos. 020/001 to 020/158 for : S.S. pipe bends and elbows to any angle. Nominal diameter of valves and pipe fittings 80 mm |
| 020178G | Extra over Item Nos. 020/001 to 020/158 for : S.S. pipe bends and elbows to any angle. Nominal diameter of valves and pipe fittings 100 mm |
| 020178H | Extra over Item Nos. 020/001 to 020/158 for : S.S. pipe bends and elbows to any angle. Nominal diameter of valves and pipe fittings 150 mm |
| 020178I | Extra over Item Nos. 020/001 to 020/158 for : S.S. pipe bends and elbows to any angle. Nominal diameter of valves and pipe fittings 200 mm |
| 020179A | Extra over Item Nos. 020/001 to 020/158 for : S.S. stop ends, plugs or strainers. Nominal diameter of valves and pipe fittings 15 mm |
| 020179B | Extra over Item Nos. 020/001 to 020/158 for : S.S. stop ends, plugs or strainers. Nominal diameter of valves and pipe fittings 20 mm |
| 020179C | Extra over Item Nos. 020/001 to 020/158 for : S.S. stop ends, plugs or strainers. Nominal diameter of valves and pipe fittings 25 mm |
| 020179D | Extra over Item Nos. 020/001 to 020/158 for : S.S. stop ends, plugs or strainers. Nominal diameter of valves and pipe fittings 40 mm |
| 020179E | Extra over Item Nos. 020/001 to 020/158 for : S.S. stop ends, plugs or strainers. Nominal diameter of valves and pipe fittings 50 mm |
| 020179F | Extra over Item Nos. 020/001 to 020/158 for : S.S. stop ends, plugs or strainers. Nominal diameter of valves and pipe fittings 80 mm |
| 020179G | Extra over Item Nos. 020/001 to 020/158 for : S.S. stop ends, plugs or strainers. Nominal diameter of valves and pipe fittings 100 mm |
| 020179H | Extra over Item Nos. 020/001 to 020/158 for : S.S. stop ends, plugs or strainers. Nominal diameter of valves and pipe fittings 150 mm |
| 020179I | Extra over Item Nos. 020/001 to 020/158 for : S.S. stop ends, plugs or strainers. Nominal diameter of valves and pipe fittings 200 mm |
| 020180A | Extra over Item Nos. 020/001 to 020/158 for : S.S. screw jointed valves or stopcocks Nominal diameter of valves and pipe fittings 15 mm |
| 020180B | Extra over Item Nos. 020/001 to 020/158 for : S.S. screw jointed valves or stopcocks Nominal diameter of valves and pipe fittings 20 mm |
| 020180C | Extra over Item Nos. 020/001 to 020/158 for : S.S. screw jointed valves or stopcocks Nominal diameter of valves and pipe fittings 25 mm |
| 020180D | Extra over Item Nos. 020/001 to 020/158 for : S.S. screw jointed valves or stopcocks Nominal diameter of valves and pipe fittings 40 mm |
| 020180E | Extra over Item Nos. 020/001 to 020/158 for : S.S. screw jointed valves or stopcocks Nominal diameter of valves and pipe fittings 50 mm |
| 020180F | Extra over Item Nos. 020/001 to 020/158 for : S.S. screw jointed valves or stopcocks Nominal diameter of valves and pipe fittings 80 mm |
| 020180G | Extra over Item Nos. 020/001 to 020/158 for : S.S. screw jointed valves or stopcocks Nominal diameter of valves and pipe fittings 100 mm |
| 020181B | Extra over Item Nos. 020/001 to 020/158 for : S.S. sockets, reducing sockets and bushings. Nominal diameter of valves and pipe fittings 20 mm |
| 020181C | Extra over Item Nos. 020/001 to 020/158 for : S.S. sockets, reducing sockets and bushings. Nominal diameter of valves and pipe fittings 25 mm |
| 020181D | Extra over Item Nos. 020/001 to 020/158 for : S.S. sockets, reducing sockets and bushings. Nominal diameter of valves and pipe fittings 40 mm |
| 020181E | Extra over Item Nos. 020/001 to 020/158 for : S.S. sockets, reducing sockets and bushings. Nominal diameter of valves and pipe fittings 50 mm |
| 020181F | Extra over Item Nos. 020/001 to 020/158 for : S.S. sockets, reducing sockets and bushings. Nominal diameter of valves and pipe fittings 80 mm |
| 020181G | Extra over Item Nos. 020/001 to 020/158 for : S.S. sockets, reducing sockets and bushings. Nominal diameter of valves and pipe fittings 100 mm |
| 020181H | Extra over Item Nos. 020/001 to 020/158 for : S.S. sockets, reducing sockets and bushings. Nominal diameter of valves and pipe fittings 150 mm |
| 020181I | Extra over Item Nos. 020/001 to 020/158 for : S.S. sockets, reducing sockets and bushings. Nominal diameter of valves and pipe fittings 200 mm |
| 020182A | Extra over Item Nos. 020/001 to 020/158 for : Leakage collection system as shown in Drawing No. WSD 1.20. Nominal diameter of valves and pipe fittings 80 mm & under |
| 020182B | Extra over Item Nos. 020/001 to 020/158 for : Leakage collection system as shown in Drawing No. WSD 1.20. Nominal diameter of valves and pipe fittings 100 mm |
| 020182C | Extra over Item Nos. 020/001 to 020/158 for : Leakage collection system as shown in Drawing No. WSD 1.20. Nominal diameter of valves and pipe fittings 125 -150 mm |
| 020182D | Extra over Item Nos. 020/001 to 020/158 for : Leakage collection system as shown in Drawing No. WSD 1.20. Nominal diameter of valves and pipe fittings 200 mm |
| 020182E | Extra over Item Nos. 020/001 to 020/158 for : Leakage collection system as shown in Drawing No. WSD 1.20. Nominal diameter of valves and pipe fittings 250 mm |
| 020182F | Extra over Item Nos. 020/001 to 020/158 for : Leakage collection system as shown in Drawing No. WSD 1.20. Nominal diameter of valves and pipe fittings 300 - 350 mm |
| 020182G | Extra over Item Nos. 020/001 to 020/158 for : Leakage collection system as shown in Drawing No. WSD 1.20. Nominal diameter of valves and pipe fittings 400 mm |
| 020182H | Extra over Item Nos. 020/001 to 020/158 for : Leakage collection system as shown in Drawing No. WSD 1.20. Nominal diameter of valves and pipe fittings 450 - 525 mm |
| 020182I | Extra over Item Nos. 020/001 to 020/158 for : Leakage collection system as shown in Drawing No. WSD 1.20. Nominal diameter of valves and pipe fittings 600 - 675 mm |
| 020182J | Extra over Item Nos. 020/001 to 020/158 for : Leakage collection system as shown in Drawing No. WSD 1.20. Nominal diameter of valves and pipe fittings 700 - 750 mm |
| 020182K | Extra over Item Nos. 020/001 to 020/158 for : Leakage collection system as shown in Drawing No. WSD 1.20. Nominal diameter of valves and pipe fittings 800 mm |
| 020182L | Extra over Item Nos. 020/001 to 020/158 for : Leakage collection system as shown in Drawing No. WSD 1.20. Nominal diameter of valves and pipe fittings 900 mm |
| 020182M | Extra over Item Nos. 020/001 to 020/158 for : Leakage collection system as shown in Drawing No. WSD 1.20. Nominal diameter of valves and pipe fittings 1000 - 1100 mm |
| 020182N | Extra over Item Nos. 020/001 to 020/158 for : Leakage collection system as shown in Drawing No. WSD 1.20. Nominal diameter of valves and pipe fittings 1200 mm |
| 020182O | Extra over Item Nos. 020/001 to 020/158 for : Leakage collection system as shown in Drawing No. WSD 1.20. Nominal diameter of valves and pipe fittings 1350 - 1400 mm |
| 020182P | Extra over Item Nos. 020/001 to 020/158 for : Leakage collection system as shown in Drawing No. WSD 1.20. Nominal diameter of valves and pipe fittings 1600 mm |
| 020182Q | Extra over Item Nos. 020/001 to 020/158 for : Leakage collection system as shown in Drawing No. WSD 1.20. Nominal diameter of valves and pipe fittings 1800 mm |
| 020182R | Extra over Item Nos. 020/001 to 020/158 for : Leakage collection system as shown in Drawing No. WSD 1.20. Nominal diameter of valves and pipe fittings 1950 - 2100 mm |
| 020182S | Extra over Item Nos. 020/001 to 020/158 for : Leakage collection system as shown in Drawing No. WSD 1.20. Nominal diameter of valves and pipe fittings >2100 mm |
| 020183A | Flange joint Nominal diameter of pipe 80 mm & under |
| 020183B | Flange joint Nominal diameter of pipe 100 mm |
| 020183C | Flange joint Nominal diameter of pipe 125 -150 mm |
| 020183D | Flange joint Nominal diameter of pipe 200 mm |
| 020183E | Flange joint Nominal diameter of pipe 250 mm |
| 020183F | Flange joint Nominal diameter of pipe 300 - 350 mm |
| 020183G | Flange joint Nominal diameter of pipe 400 mm |
| 020183H | Flange joint Nominal diameter of pipe 450 - 525 mm |
| 020183I | Flange joint Nominal diameter of pipe 600 - 675 mm |
| 020183J | Flange joint Nominal diameter of pipe 700 - 750 mm |
| 020183K | Flange joint Nominal diameter of pipe 800 mm |
| 020183L | Flange joint Nominal diameter of pipe 900 mm |
| 020183M | Flange joint Nominal diameter of pipe 1000 - 1100 mm |
| 020183N | Flange joint Nominal diameter of pipe 1200 mm |
| 020183O | Flange joint Nominal diameter of pipe 1350 - 1400 mm |
| 020183P | Flange joint Nominal diameter of pipe 1600 mm |
| 020183Q | Flange joint Nominal diameter of pipe 1800 mm |
| 020183R | Flange joint Nominal diameter of pipe 1950 - 2100 mm |
| 020183S | Flange joint Nominal diameter of pipe >2100 mm |
| 020184A | Screwed joint Nominal diameter of pipe 80 mm & under |
| 020184B | Screwed joint Nominal diameter of pipe 100 mm |
| 020184C | Screwed joint Nominal diameter of pipe 125 -150 mm |
| 020184D | Screwed joint Nominal diameter of pipe 200 mm |
| 020184E | Screwed joint Nominal diameter of pipe 250 mm |
| 020184F | Screwed joint Nominal diameter of pipe 300 - 350 mm |
| 020184G | Screwed joint Nominal diameter of pipe 400 mm |
| 020184H | Screwed joint Nominal diameter of pipe 450 - 525 mm |
| 020184I | Screwed joint Nominal diameter of pipe 600 - 675 mm |
| 020185A | Bolted gland, screw gland or detachable pipe joint including mechanical flexible joint for ductile iron pipe Nominal diameter of pipe 80 mm & under |
| 020185B | Bolted gland, screw gland or detachable pipe joint including mechanical flexible joint for ductile iron pipe Nominal diameter of pipe 100 mm |
| 020185C | Bolted gland, screw gland or detachable pipe joint including mechanical flexible joint for ductile iron pipe Nominal diameter of pipe 125 -150 mm |
| 020185D | Bolted gland, screw gland or detachable pipe joint including mechanical flexible joint for ductile iron pipe Nominal diameter of pipe 200 mm |
| 020185E | Bolted gland, screw gland or detachable pipe joint including mechanical flexible joint for ductile iron pipe Nominal diameter of pipe 250 mm |
| 020185F | Bolted gland, screw gland or detachable pipe joint including mechanical flexible joint for ductile iron pipe Nominal diameter of pipe 300 - 350 mm |
| 020185G | Bolted gland, screw gland or detachable pipe joint including mechanical flexible joint for ductile iron pipe Nominal diameter of pipe 400 mm |
| 020185H | Bolted gland, screw gland or detachable pipe joint including mechanical flexible joint for ductile iron pipe Nominal diameter of pipe 450 - 525 mm |
| 020185I | Bolted gland, screw gland or detachable pipe joint including mechanical flexible joint for ductile iron pipe Nominal diameter of pipe 600 - 675 mm |
| 020185J | Bolted gland, screw gland or detachable pipe joint including mechanical flexible joint for ductile iron pipe Nominal diameter of pipe 700 - 750 mm |
| 020185K | Bolted gland, screw gland or detachable pipe joint including mechanical flexible joint for ductile iron pipe Nominal diameter of pipe 800 mm |
| 020185L | Bolted gland, screw gland or detachable pipe joint including mechanical flexible joint for ductile iron pipe Nominal diameter of pipe 900 mm |
| 020185M | Bolted gland, screw gland or detachable pipe joint including mechanical flexible joint for ductile iron pipe Nominal diameter of pipe 1000 - 1100 mm |
| 020186C | Slip-on type coupling joint Nominal diameter of pipe 125 -150 mm |
| 020186D | Slip-on type coupling joint Nominal diameter of pipe 200 mm |
| 020186E | Slip-on type coupling joint Nominal diameter of pipe 250 mm |
| 020186F | Slip-on type coupling joint Nominal diameter of pipe 300 - 350 mm |
| 020186G | Slip-on type coupling joint Nominal diameter of pipe 400 mm |
| 020186H | Slip-on type coupling joint Nominal diameter of pipe 450 - 525 mm |
| 020186I | Slip-on type coupling joint Nominal diameter of pipe 600 - 675 mm |
| 020186J | Slip-on type coupling joint Nominal diameter of pipe 700 - 750 mm |
| 020186K | Slip-on type coupling joint Nominal diameter of pipe 800 mm |
| 020186L | Slip-on type coupling joint Nominal diameter of pipe 900 mm |
| 020186M | Slip-on type coupling joint Nominal diameter of pipe 1000 - 1100 mm |
| 020186N | Slip-on type coupling joint Nominal diameter of pipe 1200 mm |
| 020186O | Slip-on type coupling joint Nominal diameter of pipe 1350 - 1400 mm |
| 020186P | Slip-on type coupling joint Nominal diameter of pipe 1600 mm |
| 020186Q | Slip-on type coupling joint Nominal diameter of pipe 1800 mm |
| 020186R | Slip-on type coupling joint Nominal diameter of pipe 1950 - 2100 mm |
| 020186S | Slip-on type coupling joint Nominal diameter of pipe >2100 mm |
| 020187C | Slip-on type flange adaptor joint Nominal diameter of pipe 125 -150 mm |
| 020187D | Slip-on type flange adaptor joint Nominal diameter of pipe 200 mm |
| 020187E | Slip-on type flange adaptor joint Nominal diameter of pipe 250 mm |
| 020187F | Slip-on type flange adaptor joint Nominal diameter of pipe 300 - 350 mm |
| 020187G | Slip-on type flange adaptor joint Nominal diameter of pipe 400 mm |
| 020187H | Slip-on type flange adaptor joint Nominal diameter of pipe 450 - 525 mm |
| 020187I | Slip-on type flange adaptor joint Nominal diameter of pipe 600 - 675 mm |
| 020187J | Slip-on type flange adaptor joint Nominal diameter of pipe 700 - 750 mm |
| 020187K | Slip-on type flange adaptor joint Nominal diameter of pipe 800 mm |
| 020187L | Slip-on type flange adaptor joint Nominal diameter of pipe 900 mm |
| 020187M | Slip-on type flange adaptor joint Nominal diameter of pipe 1000 - 1100 mm |
| 020187N | Slip-on type flange adaptor joint Nominal diameter of pipe 1200 mm |
| 020187O | Slip-on type flange adaptor joint Nominal diameter of pipe 1350 - 1400 mm |
| 020187P | Slip-on type flange adaptor joint Nominal diameter of pipe 1600 mm |
| 020187Q | Slip-on type flange adaptor joint Nominal diameter of pipe 1800 mm |
| 020187R | Slip-on type flange adaptor joint Nominal diameter of pipe 1950 - 2100 mm |
| 020187S | Slip-on type flange adaptor joint Nominal diameter of pipe >2100 mm |
| 020188C | Victaulic joint Nominal diameter of pipe 125 -150 mm |
| 020188D | Victaulic joint Nominal diameter of pipe 200 mm |
| 020188E | Victaulic joint Nominal diameter of pipe 250 mm |
| 020188F | Victaulic joint Nominal diameter of pipe 300 - 350 mm |
| 020188G | Victaulic joint Nominal diameter of pipe 400 mm |
| 020188H | Victaulic joint Nominal diameter of pipe 450 - 525 mm |
| 020188I | Victaulic joint Nominal diameter of pipe 600 - 675 mm |
| 020188J | Victaulic joint Nominal diameter of pipe 700 - 750 mm |
| 020188K | Victaulic joint Nominal diameter of pipe 800 mm |
| 020188L | Victaulic joint Nominal diameter of pipe 900 mm |
| 020188M | Victaulic joint Nominal diameter of pipe 1000 - 1100 mm |
| 020189A | Tyton' joint or automatic coupling Nominal diameter of pipe 80 mm & under |
| 020189B | Tyton' joint or automatic coupling Nominal diameter of pipe 100 mm |
| 020189C | Tyton' joint or automatic coupling Nominal diameter of pipe 125 -150 mm |
| 020189D | Tyton' joint or automatic coupling Nominal diameter of pipe 200 mm |
| 020189E | Tyton' joint or automatic coupling Nominal diameter of pipe 250 mm |
| 020189F | Tyton' joint or automatic coupling Nominal diameter of pipe 300 - 350 mm |
| 020189G | Tyton' joint or automatic coupling Nominal diameter of pipe 400 mm |
| 020189H | Tyton' joint or automatic coupling Nominal diameter of pipe 450 - 525 mm |
| 020189I | Tyton' joint or automatic coupling Nominal diameter of pipe 600 - 675 mm |
| 020190A | Electrically welded butt or lap joints to full thickness of standard pipe Nominal diameter of pipe 80 mm & under |
| 020190B | Electrically welded butt or lap joints to full thickness of standard pipe Nominal diameter of pipe 100 mm |
| 020190C | Electrically welded butt or lap joints to full thickness of standard pipe Nominal diameter of pipe 125 -150 mm |
| 020190D | Electrically welded butt or lap joints to full thickness of standard pipe Nominal diameter of pipe 200 mm |
| 020190E | Electrically welded butt or lap joints to full thickness of standard pipe Nominal diameter of pipe 250 mm |
| 020190F | Electrically welded butt or lap joints to full thickness of standard pipe Nominal diameter of pipe 300 - 350 mm |
| 020190G | Electrically welded butt or lap joints to full thickness of standard pipe Nominal diameter of pipe 400 mm |
| 020190H | Electrically welded butt or lap joints to full thickness of standard pipe Nominal diameter of pipe 450 - 525 mm |
| 020190I | Electrically welded butt or lap joints to full thickness of standard pipe Nominal diameter of pipe 600 - 675 mm |
| 020190J | Electrically welded butt or lap joints to full thickness of standard pipe Nominal diameter of pipe 700 - 750 mm |
| 020190K | Electrically welded butt or lap joints to full thickness of standard pipe Nominal diameter of pipe 800 mm |
| 020190L | Electrically welded butt or lap joints to full thickness of standard pipe Nominal diameter of pipe 900 mm |
| 020190M | Electrically welded butt or lap joints to full thickness of standard pipe Nominal diameter of pipe 1000 - 1100 mm |
| 020190N | Electrically welded butt or lap joints to full thickness of standard pipe Nominal diameter of pipe 1200 mm |
| 020190O | Electrically welded butt or lap joints to full thickness of standard pipe Nominal diameter of pipe 1350 - 1400 mm |
| 020190P | Electrically welded butt or lap joints to full thickness of standard pipe Nominal diameter of pipe 1600 mm |
| 020190Q | Electrically welded butt or lap joints to full thickness of standard pipe Nominal diameter of pipe 1800 mm |
| 020190R | Electrically welded butt or lap joints to full thickness of standard pipe Nominal diameter of pipe 1950 - 2100 mm |
| 020190S | Electrically welded butt or lap joints to full thickness of standard pipe Nominal diameter of pipe >2100 mm |
| 020191A | U.P.V.C. cold welded joint. Nominal diameter of pipe 15 mm |
| 020191B | U.P.V.C. cold welded joint. Nominal diameter of pipe 20 mm |
| 020191C | U.P.V.C. cold welded joint. Nominal diameter of pipe 25 mm |
| 020191D | U.P.V.C. cold welded joint. Nominal diameter of pipe 40 mm |
| 020191E | U.P.V.C. cold welded joint. Nominal diameter of pipe 50 mm |
| 020191F | U.P.V.C. cold welded joint. Nominal diameter of pipe 80 mm |
| 020191G | U.P.V.C. cold welded joint. Nominal diameter of pipe 100 mm |
| 020191H | U.P.V.C. cold welded joint. Nominal diameter of pipe 150 mm |
| 020191I | U.P.V.C. cold welded joint. Nominal diameter of pipe 200 mm |
| 020191J | U.P.V.C. cold welded joint. Nominal diameter of pipe 250 mm |
| 020192E | U.P.V.C. automatic push-in type joint. Nominal diameter of pipe 50 mm |
| 020192F | U.P.V.C. automatic push-in type joint. Nominal diameter of pipe 80 mm |
| 020192G | U.P.V.C. automatic push-in type joint. Nominal diameter of pipe 100 mm |
| 020192H | U.P.V.C. automatic push-in type joint. Nominal diameter of pipe 150 mm |
| 020192I | U.P.V.C. automatic push-in type joint. Nominal diameter of pipe 200 mm |
| 020192J | U.P.V.C. automatic push-in type joint. Nominal diameter of pipe 250 mm |
| 020193A | Electrofusion joint for PE pipes. Nominal diameter of pipe 15 mm |
| 020193B | Electrofusion joint for PE pipes. Nominal diameter of pipe 20 mm |
| 020193C | Electrofusion joint for PE pipes. Nominal diameter of pipe 25 mm |
| 020193D | Electrofusion joint for PE pipes. Nominal diameter of pipe 40 mm |
| 020193E | Electrofusion joint for PE pipes. Nominal diameter of pipe 50 mm |
| 020193F | Electrofusion joint for PE pipes. Nominal diameter of pipe 80 mm |
| 020193G | Electrofusion joint for PE pipes. Nominal diameter of pipe 100 mm |
| 020193H | Electrofusion joint for PE pipes. Nominal diameter of pipe 150 mm |
| 020193I | Electrofusion joint for PE pipes. Nominal diameter of pipe 200 mm |
| 020193J | Electrofusion joint for PE pipes. Nominal diameter of pipe 250 mm |
| 020193K | Electrofusion joint for PE pipes. Nominal diameter of pipe 300 - 350 mm |
| 020193L | Electrofusion joint for PE pipes. Nominal diameter of pipe 400 mm |
| 020193M | Electrofusion joint for PE pipes. Nominal diameter of pipe 450 - 525 mm |
| 020193N | Electrofusion joint for PE pipes. Nominal diameter of pipe 600 - 675 mm |
| 020194A | Butt welded joint for PE pipes. Nominal diameter of pipe 15 mm |
| 020194B | Butt welded joint for PE pipes. Nominal diameter of pipe 20 mm |
| 020194C | Butt welded joint for PE pipes. Nominal diameter of pipe 25 mm |
| 020194D | Butt welded joint for PE pipes. Nominal diameter of pipe 40 mm |
| 020194E | Butt welded joint for PE pipes. Nominal diameter of pipe 50 mm |
| 020194F | Butt welded joint for PE pipes. Nominal diameter of pipe 80 mm |
| 020194G | Butt welded joint for PE pipes. Nominal diameter of pipe 100 mm |
| 020194H | Butt welded joint for PE pipes. Nominal diameter of pipe 150 mm |
| 020194I | Butt welded joint for PE pipes. Nominal diameter of pipe 200 mm |
| 020194J | Butt welded joint for PE pipes. Nominal diameter of pipe 250 mm |
| 020195A | Mechanical coupling joint for PE pipes. Nominal diameter of pipe 15 mm |
| 020195B | Mechanical coupling joint for PE pipes. Nominal diameter of pipe 20 mm |
| 020195C | Mechanical coupling joint for PE pipes. Nominal diameter of pipe 25 mm |
| 020195D | Mechanical coupling joint for PE pipes. Nominal diameter of pipe 40 mm |
| 020195E | Mechanical coupling joint for PE pipes. Nominal diameter of pipe 50 mm |
| 020195F | Mechanical coupling joint for PE pipes. Nominal diameter of pipe 80 mm |
| 020195G | Mechanical coupling joint for PE pipes. Nominal diameter of pipe 100 mm |
| 020195H | Mechanical coupling joint for PE pipes. Nominal diameter of pipe 150 mm |
| 020195I | Mechanical coupling joint for PE pipes. Nominal diameter of pipe 200 mm |
| 020195J | Mechanical coupling joint for PE pipes. Nominal diameter of pipe 250 mm |
| 020195K | Mechanical coupling joint for PE pipes. Nominal diameter of pipe 300 - 350 mm |
| 020195L | Mechanical coupling joint for PE pipes. Nominal diameter of pipe 400 mm |
| 020195M | Mechanical coupling joint for PE pipes. Nominal diameter of pipe 450 - 525 mm |
| 020195N | Mechanical coupling joint for PE pipes. Nominal diameter of pipe 600 - 675 mm |
| 020196E | Flange joint for PE pipes. Nominal diameter of pipe 50 mm |
| 020196F | Flange joint for PE pipes. Nominal diameter of pipe 80 mm |
| 020196G | Flange joint for PE pipes. Nominal diameter of pipe 100 mm |
| 020196H | Flange joint for PE pipes. Nominal diameter of pipe 150 mm |
| 020196I | Flange joint for PE pipes. Nominal diameter of pipe 200 mm |
| 020196J | Flange joint for PE pipes. Nominal diameter of pipe 250 mm |
| 020197A | Welded joint for S.S. pipes. Nominal diameter of pipe 15 mm |
| 020197B | Welded joint for S.S. pipes. Nominal diameter of pipe 20 mm |
| 020197C | Welded joint for S.S. pipes. Nominal diameter of pipe 25 mm |
| 020197D | Welded joint for S.S. pipes. Nominal diameter of pipe 40 mm |
| 020197E | Welded joint for S.S. pipes. Nominal diameter of pipe 50 mm |
| 020197F | Welded joint for S.S. pipes. Nominal diameter of pipe 80 mm |
| 020197G | Welded joint for S.S. pipes. Nominal diameter of pipe 100 mm |
| 020197H | Welded joint for S.S. pipes. Nominal diameter of pipe 150 mm |
| 020197I | Welded joint for S.S. pipes. Nominal diameter of pipe 200 mm |
| 020198A | Flange joint for S.S. pipes. Nominal diameter of pipe 15 mm |
| 020198B | Flange joint for S.S. pipes. Nominal diameter of pipe 20 mm |
| 020198C | Flange joint for S.S. pipes. Nominal diameter of pipe 25 mm |
| 020198D | Flange joint for S.S. pipes. Nominal diameter of pipe 40 mm |
| 020198E | Flange joint for S.S. pipes. Nominal diameter of pipe 50 mm |
| 020198F | Flange joint for S.S. pipes. Nominal diameter of pipe 80 mm |
| 020198G | Flange joint for S.S. pipes. Nominal diameter of pipe 100 mm |
| 020198H | Flange joint for S.S. pipes. Nominal diameter of pipe 150 mm |
| 020198I | Flange joint for S.S. pipes. Nominal diameter of pipe 200 mm |
| 020199A | Threading G.I. pipes to the standard length (B.S. 21). Nominal diameter of pipe 15 mm |
| 020199B | Threading G.I. pipes to the standard length (B.S. 21). Nominal diameter of pipe 20 mm |
| 020199C | Threading G.I. pipes to the standard length (B.S. 21). Nominal diameter of pipe 25 mm |
| 020199D | Threading G.I. pipes to the standard length (B.S. 21). Nominal diameter of pipe 40 mm |
| 020199E | Threading G.I. pipes to the standard length (B.S. 21). Nominal diameter of pipe 50 mm |
| 020199F | Threading G.I. pipes to the standard length (B.S. 21). Nominal diameter of pipe 80 mm |
| 020199G | Threading G.I. pipes to the standard length (B.S. 21). Nominal diameter of pipe 100 mm |
| 020199H | Threading G.I. pipes to the standard length (B.S. 21). Nominal diameter of pipe 150 mm |
| 020200A | Threading S.S. pipes to the standard length. Nominal diameter of pipe 15 mm |
| 020200B | Threading S.S. pipes to the standard length. Nominal diameter of pipe 20 mm |
| 020200C | Threading S.S. pipes to the standard length. Nominal diameter of pipe 25 mm |
| 020200D | Threading S.S. pipes to the standard length. Nominal diameter of pipe 40 mm |
| 020200E | Threading S.S. pipes to the standard length. Nominal diameter of pipe 50 mm |
| 020200F | Threading S.S. pipes to the standard length. Nominal diameter of pipe 80 mm |
| 020200G | Threading S.S. pipes to the standard length. Nominal diameter of pipe 100 mm |
| 020200H | Threading S.S. pipes to the standard length. Nominal diameter of pipe 150 mm |
| 020201A | Prepare ends of steel pipe for butt welding. Nominal diameter of pipe 80 mm & under |
| 020201B | Prepare ends of steel pipe for butt welding. Nominal diameter of pipe 100 mm |
| 020201C | Prepare ends of steel pipe for butt welding. Nominal diameter of pipe 125 -150 mm |
| 020201D | Prepare ends of steel pipe for butt welding. Nominal diameter of pipe 200 mm |
| 020201E | Prepare ends of steel pipe for butt welding. Nominal diameter of pipe 250 mm |
| 020201F | Prepare ends of steel pipe for butt welding. Nominal diameter of pipe 300 - 350 mm |
| 020201G | Prepare ends of steel pipe for butt welding. Nominal diameter of pipe 400 mm |
| 020201H | Prepare ends of steel pipe for butt welding. Nominal diameter of pipe 450 - 525mm |
| 020201I | Prepare ends of steel pipe for butt welding. Nominal diameter of pipe 600 - 675mm |
| 020201J | Prepare ends of steel pipe for butt welding. Nominal diameter of pipe 700 - 750 mm |
| 020201K | Prepare ends of steel pipe for butt welding. Nominal diameter of pipe 800 mm |
| 020201L | Prepare ends of steel pipe for butt welding. Nominal diameter of pipe 900 mm |
| 020201M | Prepare ends of steel pipe for butt welding. Nominal diameter of pipe 1000 - 1100 mm |
| 020201N | Prepare ends of steel pipe for butt welding. Nominal diameter of pipe 1200 mm |
| 020201O | Prepare ends of steel pipe for butt welding. Nominal diameter of pipe 1350 - 1400 mm |
| 020201P | Prepare ends of steel pipe for butt welding. Nominal diameter of pipe 1600 mm |
| 020201Q | Prepare ends of steel pipe for butt welding. Nominal diameter of pipe 1800 mm |
| 020201R | Prepare ends of steel pipe for butt welding. Nominal diameter of pipe 1950 - 2100 mm |
| 020201S | Prepare ends of steel pipe for butt welding. Nominal diameter of pipe > 2100 mm |
| 020202A | Prepare ends of steel pipe for lap welding or Johnson coupling. Nominal diameter of pipe 80 mm & under |
| 020202B | Prepare ends of steel pipe for lap welding or Johnson coupling. Nominal diameter of pipe 100 mm |
| 020202C | Prepare ends of steel pipe for lap welding or Johnson coupling. Nominal diameter of pipe 125 -150 mm |
| 020202D | Prepare ends of steel pipe for lap welding or Johnson coupling. Nominal diameter of pipe 200 mm |
| 020202E | Prepare ends of steel pipe for lap welding or Johnson coupling. Nominal diameter of pipe 250 mm |
| 020202F | Prepare ends of steel pipe for lap welding or Johnson coupling. Nominal diameter of pipe 300 - 350 mm |
| 020202G | Prepare ends of steel pipe for lap welding or Johnson coupling. Nominal diameter of pipe 400 mm |
| 020202H | Prepare ends of steel pipe for lap welding or Johnson coupling. Nominal diameter of pipe 450 - 525mm |
| 020202I | Prepare ends of steel pipe for lap welding or Johnson coupling. Nominal diameter of pipe 600 - 675mm |
| 020202J | Prepare ends of steel pipe for lap welding or Johnson coupling. Nominal diameter of pipe 700 - 750 mm |
| 020202K | Prepare ends of steel pipe for lap welding or Johnson coupling. Nominal diameter of pipe 800 mm |
| 020202L | Prepare ends of steel pipe for lap welding or Johnson coupling. Nominal diameter of pipe 900 mm |
| 020202M | Prepare ends of steel pipe for lap welding or Johnson coupling. Nominal diameter of pipe 1000 - 1100 mm |
| 020202N | Prepare ends of steel pipe for lap welding or Johnson coupling. Nominal diameter of pipe 1200 mm |
| 020202O | Prepare ends of steel pipe for lap welding or Johnson coupling. Nominal diameter of pipe 1350 - 1400 mm |
| 020202P | Prepare ends of steel pipe for lap welding or Johnson coupling. Nominal diameter of pipe 1600 mm |
| 020202Q | Prepare ends of steel pipe for lap welding or Johnson coupling. Nominal diameter of pipe 1800 mm |
| 020202R | Prepare ends of steel pipe for lap welding or Johnson coupling. Nominal diameter of pipe 1950 - 2100 mm |
| 020202S | Prepare ends of steel pipe for lap welding or Johnson coupling. Nominal diameter of pipe > 2100 mm |
| 020204A | Prepare ends of C.I. or ductile iron pipe for 'Tyton' joint or bolted gland joint. Nominal diameter of pipe 80 mm & under |
| 020204B | Prepare ends of C.I. or ductile iron pipe for 'Tyton' joint or bolted gland joint. Nominal diameter of pipe 100 mm |
| 020204C | Prepare ends of C.I. or ductile iron pipe for 'Tyton' joint or bolted gland joint. Nominal diameter of pipe 125 -150 mm |
| 020204D | Prepare ends of C.I. or ductile iron pipe for 'Tyton' joint or bolted gland joint. Nominal diameter of pipe 200 mm |
| 020204E | Prepare ends of C.I. or ductile iron pipe for 'Tyton' joint or bolted gland joint. Nominal diameter of pipe 250 mm |
| 020204F | Prepare ends of C.I. or ductile iron pipe for 'Tyton' joint or bolted gland joint. Nominal diameter of pipe 300 - 350 mm |
| 020204G | Prepare ends of C.I. or ductile iron pipe for 'Tyton' joint or bolted gland joint. Nominal diameter of pipe 400 mm |
| 020204H | Prepare ends of C.I. or ductile iron pipe for 'Tyton' joint or bolted gland joint. Nominal diameter of pipe 450 - 525mm |
| 020204I | Prepare ends of C.I. or ductile iron pipe for 'Tyton' joint or bolted gland joint. Nominal diameter of pipe 600 - 675mm |
| 020204J | Prepare ends of C.I. or ductile iron pipe for 'Tyton' joint or bolted gland joint. Nominal diameter of pipe 700 - 750 mm |
| 020204K | Prepare ends of C.I. or ductile iron pipe for 'Tyton' joint or bolted gland joint. Nominal diameter of pipe 800 mm |
| 020204L | Prepare ends of C.I. or ductile iron pipe for 'Tyton' joint or bolted gland joint. Nominal diameter of pipe 900 mm |
| 020204M | Prepare ends of C.I. or ductile iron pipe for 'Tyton' joint or bolted gland joint. Nominal diameter of pipe 1000 - 1100 mm |
| 020204N | Prepare ends of C.I. or ductile iron pipe for 'Tyton' joint or bolted gland joint. Nominal diameter of pipe 1200 mm |
| 020204O | Prepare ends of C.I. or ductile iron pipe for 'Tyton' joint or bolted gland joint. Nominal diameter of pipe 1350 - 1400 mm |
| 020205A | Cut steel pipe at any angle to the centreline of pipe. Nominal diameter of pipe 80 mm & under |
| 020205B | Cut steel pipe at any angle to the centreline of pipe. Nominal diameter of pipe 100 mm |
| 020205C | Cut steel pipe at any angle to the centreline of pipe. Nominal diameter of pipe 125 -150 mm |
| 020205D | Cut steel pipe at any angle to the centreline of pipe. Nominal diameter of pipe 200 mm |
| 020205E | Cut steel pipe at any angle to the centreline of pipe. Nominal diameter of pipe 250 mm |
| 020205F | Cut steel pipe at any angle to the centreline of pipe. Nominal diameter of pipe 300 - 350 mm |
| 020205G | Cut steel pipe at any angle to the centreline of pipe. Nominal diameter of pipe 400 mm |
| 020205H | Cut steel pipe at any angle to the centreline of pipe. Nominal diameter of pipe 450 - 525mm |
| 020205I | Cut steel pipe at any angle to the centreline of pipe. Nominal diameter of pipe 600 - 675mm |
| 020205J | Cut steel pipe at any angle to the centreline of pipe. Nominal diameter of pipe 700 - 750 mm |
| 020205K | Cut steel pipe at any angle to the centreline of pipe. Nominal diameter of pipe 800 mm |
| 020205L | Cut steel pipe at any angle to the centreline of pipe. Nominal diameter of pipe 900 mm |
| 020205M | Cut steel pipe at any angle to the centreline of pipe. Nominal diameter of pipe 1000 - 1100 mm |
| 020205N | Cut steel pipe at any angle to the centreline of pipe. Nominal diameter of pipe 1200 mm |
| 020205O | Cut steel pipe at any angle to the centreline of pipe. Nominal diameter of pipe 1350 - 1400 mm |
| 020205P | Cut steel pipe at any angle to the centreline of pipe. Nominal diameter of pipe 1600 mm |
| 020205Q | Cut steel pipe at any angle to the centreline of pipe. Nominal diameter of pipe 1800 mm |
| 020205R | Cut steel pipe at any angle to the centreline of pipe. Nominal diameter of pipe 1950 - 2100 mm |
| 020205S | Cut steel pipe at any angle to the centreline of pipe. Nominal diameter of pipe > 2100 mm |
| 020206A | Cut C.I. Pipe. Nominal diameter of pipe 80 mm & under |
| 020206B | Cut C.I. Pipe. Nominal diameter of pipe 100 mm |
| 020206C | Cut C.I. Pipe. Nominal diameter of pipe 125 -150 mm |
| 020206D | Cut C.I. Pipe. Nominal diameter of pipe 200 mm |
| 020206E | Cut C.I. Pipe. Nominal diameter of pipe 250 mm |
| 020206F | Cut C.I. Pipe. Nominal diameter of pipe 300 - 350 mm |
| 020206G | Cut C.I. Pipe. Nominal diameter of pipe 400 mm |
| 020206H | Cut C.I. Pipe. Nominal diameter of pipe 450 - 525mm |
| 020207A | Cut ductile iron pipe. Nominal diameter of pipe 80 mm & under |
| 020207B | Cut ductile iron pipe. Nominal diameter of pipe 100 mm |
| 020207C | Cut ductile iron pipe. Nominal diameter of pipe 125 -150 mm |
| 020207D | Cut ductile iron pipe. Nominal diameter of pipe 200 mm |
| 020207E | Cut ductile iron pipe. Nominal diameter of pipe 250 mm |
| 020207F | Cut ductile iron pipe. Nominal diameter of pipe 300 - 350 mm |
| 020207G | Cut ductile iron pipe. Nominal diameter of pipe 400 mm |
| 020207H | Cut ductile iron pipe. Nominal diameter of pipe 450 - 525mm |
| 020207I | Cut ductile iron pipe. Nominal diameter of pipe 600 - 675mm |
| 020207J | Cut ductile iron pipe. Nominal diameter of pipe 700 - 750 mm |
| 020207K | Cut ductile iron pipe. Nominal diameter of pipe 800 mm |
| 020207L | Cut ductile iron pipe. Nominal diameter of pipe 900 mm |
| 020207M | Cut ductile iron pipe. Nominal diameter of pipe 1000 - 1100 mm |
| 020207N | Cut ductile iron pipe. Nominal diameter of pipe 1200 mm |
| 020207O | Cut ductile iron pipe. Nominal diameter of pipe 1350 - 1400 mm |
| 020208aN | Cut pipes rehabilitated with Tyfo Fibrwrap system Nominal diameter of pipe 1200 mm |
| 020208aO | Cut pipes rehabilitated with Tyfo Fibrwrap system Nominal diameter of pipe 1350 - 1400 mm |
| 020208aP | Cut pipes rehabilitated with Tyfo Fibrwrap system Nominal diameter of pipe 1600 mm |
| 020208M | Cut SL rehabilitated pipes Nominal diameter of pipe 1000 - 1100 mm |
| 020208N | Cut SL rehabilitated pipes Nominal diameter of pipe 1200 mm |
| 020209B | Cut CIPP or CFL rehabilitated pipes. Nominal diameter of pipe 100 mm |
| 020209C | Cut CIPP or CFL rehabilitated pipes. Nominal diameter of pipe 125 -150 mm |
| 020209D | Cut CIPP or CFL rehabilitated pipes. Nominal diameter of pipe 200 mm |
| 020209E | Cut CIPP or CFL rehabilitated pipes. Nominal diameter of pipe 250 mm |
| 020209F | Cut CIPP or CFL rehabilitated pipes. Nominal diameter of pipe 300 - 350 mm |
| 020209G | Cut CIPP or CFL rehabilitated pipes. Nominal diameter of pipe 400 mm |
| 020209H | Cut CIPP or CFL rehabilitated pipes. Nominal diameter of pipe 450 - 525mm |
| 020209I | Cut CIPP or CFL rehabilitated pipes. Nominal diameter of pipe 600 - 675mm |
| 020209J | Cut CIPP or CFL rehabilitated pipes. Nominal diameter of pipe 700 - 750 mm |
| 020209K | Cut CIPP or CFL rehabilitated pipes. Nominal diameter of pipe 800 mm |
| 020210B | Prepare ends of CIPP rehabilitated pipes for jointing including complete installation of stainless steel end rings with rubber gasket or insert rings. Nominal diameter of pipe 100 mm |
| 020210C | Prepare ends of CIPP rehabilitated pipes for jointing including complete installation of stainless steel end rings with rubber gasket or insert rings. Nominal diameter of pipe 125 -150 mm |
| 020210D | Prepare ends of CIPP rehabilitated pipes for jointing including complete installation of stainless steel end rings with rubber gasket or insert rings. Nominal diameter of pipe 200 mm |
| 020210E | Prepare ends of CIPP rehabilitated pipes for jointing including complete installation of stainless steel end rings with rubber gasket or insert rings. Nominal diameter of pipe 250 mm |
| 020210F | Prepare ends of CIPP rehabilitated pipes for jointing including complete installation of stainless steel end rings with rubber gasket or insert rings. Nominal diameter of pipe 300 - 350 mm |
| 020210G | Prepare ends of CIPP rehabilitated pipes for jointing including complete installation of stainless steel end rings with rubber gasket or insert rings. Nominal diameter of pipe 400 mm |
| 020210H | Prepare ends of CIPP rehabilitated pipes for jointing including complete installation of stainless steel end rings with rubber gasket or insert rings. Nominal diameter of pipe 450 - 525mm |
| 020210I | Prepare ends of CIPP rehabilitated pipes for jointing including complete installation of stainless steel end rings with rubber gasket or insert rings. Nominal diameter of pipe 600 - 675mm |
| 020210J | Prepare ends of CIPP rehabilitated pipes for jointing including complete installation of stainless steel end rings with rubber gasket or insert rings. Nominal diameter of pipe 700 - 750 mm |
| 020210K | Prepare ends of CIPP rehabilitated pipes for jointing including complete installation of stainless steel end rings with rubber gasket or insert rings. Nominal diameter of pipe 800 mm |
| 020211aM | Prepare ends of SL rehabilitated pipes for jointing including complete installation of stainless steel insert ring to the PE pipe. Nominal diameter of pipe 1000 - 1100 mm |
| 020211aN | Prepare ends of SL rehabilitated pipes for jointing including complete installation of stainless steel insert ring to the PE pipe. Nominal diameter of pipe 1200 mm |
| 020211C | Prepare ends of CFL rehabilitated pipes for jointing including complete installaion of stainless steel insert ring to the swaged PE pipe. Nominal diameter of pipe 125 -150 mm |
| 020211D | Prepare ends of CFL rehabilitated pipes for jointing including complete installaion of stainless steel insert ring to the swaged PE pipe. Nominal diameter of pipe 200 mm |
| 020211E | Prepare ends of CFL rehabilitated pipes for jointing including complete installaion of stainless steel insert ring to the swaged PE pipe. Nominal diameter of pipe 250 mm |
| 020211F | Prepare ends of CFL rehabilitated pipes for jointing including complete installaion of stainless steel insert ring to the swaged PE pipe. Nominal diameter of pipe 300 - 350 mm |
| 020212A | Cut C.I. pipes at W.S.D. depots. Nominal diameter of pipe 80 mm & under |
| 020212B | Cut C.I. pipes at W.S.D. depots. Nominal diameter of pipe 100 mm |
| 020212C | Cut C.I. pipes at W.S.D. depots. Nominal diameter of pipe 125 -150 mm |
| 020212D | Cut C.I. pipes at W.S.D. depots. Nominal diameter of pipe 200 mm |
| 020212E | Cut C.I. pipes at W.S.D. depots. Nominal diameter of pipe 250 mm |
| 020212F | Cut C.I. pipes at W.S.D. depots. Nominal diameter of pipe 300 - 350 mm |
| 020212G | Cut C.I. pipes at W.S.D. depots. Nominal diameter of pipe 400 mm |
| 020212H | Cut C.I. pipes at W.S.D. depots. Nominal diameter of pipe 450 - 525mm |
| 020212I | Cut C.I. pipes at W.S.D. depots. Nominal diameter of pipe 600 - 675mm |
| 020213N | Prepare ends of pipes rehabilitated by Tyfo Fibrwrap System for jointing including complete installation of stainless steel end rings and rubber gasket. Nominal diameter of pipe 1200mm |
| 020213O | Prepare ends of pipes rehabilitated by Tyfo Fibrwrap System for jointing including complete installation of stainless steel end rings and rubber gasket. Nominal diameter of pipe 1350 - 1400mm |
| 020213P | Prepare ends of pipes rehabilitated by Tyfo Fibrwrap System for jointing including complete installation of stainless steel end rings and rubber gasket. Nominal diameter of pipe 1600mm |
| 020214B | Cut ductile iron pipes at W.S.D. depots. Nominal diameter of pipe 100 mm |
| 020214C | Cut ductile iron pipes at W.S.D. depots. Nominal diameter of pipe 125 -150 mm |
| 020214D | Cut ductile iron pipes at W.S.D. depots. Nominal diameter of pipe 200 mm |
| 020214E | Cut ductile iron pipes at W.S.D. depots. Nominal diameter of pipe 250 mm |
| 020214F | Cut ductile iron pipes at W.S.D. depots. Nominal diameter of pipe 300 - 350 mm |
| 020214G | Cut ductile iron pipes at W.S.D. depots. Nominal diameter of pipe 400 mm |
| 020214H | Cut ductile iron pipes at W.S.D. depots. Nominal diameter of pipe 450 - 525mm |
| 020215A | Cut and prepare U.P.V.C. pipe for jointing. 15 mm |
| 020215B | Cut and prepare U.P.V.C. pipe for jointing. 20 mm |
| 020215C | Cut and prepare U.P.V.C. pipe for jointing. 25 mm |
| 020215D | Cut and prepare U.P.V.C. pipe for jointing. 40 mm |
| 020215E | Cut and prepare U.P.V.C. pipe for jointing. 50 mm |
| 020215F | Cut and prepare U.P.V.C. pipe for jointing. 80 mm |
| 020215G | Cut and prepare U.P.V.C. pipe for jointing. 100mm |
| 020215H | Cut and prepare U.P.V.C. pipe for jointing. 150mm |
| 020215I | Cut and prepare U.P.V.C. pipe for jointing. 200mm |
| 020215J | Cut and prepare U.P.V.C. pipe for jointing. 250mm |
| 020216A | Cut G.I. Pipe. 15 mm |
| 020216B | Cut G.I. Pipe. 20 mm |
| 020216C | Cut G.I. Pipe. 25 mm |
| 020216D | Cut G.I. Pipe. 40 mm |
| 020216E | Cut G.I. Pipe. 50 mm |
| 020216F | Cut G.I. Pipe. 80 mm |
| 020216G | Cut G.I. Pipe. 100mm |
| 020216H | Cut G.I. Pipe. 150mm |
| 020217A | Cut and prepare PE pipe for jointing. 15 mm |
| 020217B | Cut and prepare PE pipe for jointing. 20 mm |
| 020217C | Cut and prepare PE pipe for jointing. 25 mm |
| 020217D | Cut and prepare PE pipe for jointing. 40 mm |
| 020217E | Cut and prepare PE pipe for jointing. 50 mm |
| 020217F | Cut and prepare PE pipe for jointing. 80 mm |
| 020217G | Cut and prepare PE pipe for jointing. 100mm |
| 020217H | Cut and prepare PE pipe for jointing. 150mm |
| 020217I | Cut and prepare PE pipe for jointing. 200mm |
| 020217J | Cut and prepare PE pipe for jointing. 250mm |
| 020218A | Cut S.S. pipe. 15 mm |
| 020218B | Cut S.S. pipe. 20 mm |
| 020218C | Cut S.S. pipe. 25 mm |
| 020218D | Cut S.S. pipe. 40 mm |
| 020218E | Cut S.S. pipe. 50 mm |
| 020218F | Cut S.S. pipe. 80 mm |
| 020218G | Cut S.S. pipe. 100mm |
| 020218H | Cut S.S. pipe. 150mm |
| 030001A | Pick up from trench or chambers serviceable bitumen lined steel pipes, specials and fittings (excluding disconnection). Nominal diameter of pipe 80 mm & under |
| 030001B | Pick up from trench or chambers serviceable bitumen lined steel pipes, specials and fittings (excluding disconnection). Nominal diameter of pipe 100 mm |
| 030001C | Pick up from trench or chambers serviceable bitumen lined steel pipes, specials and fittings (excluding disconnection). Nominal diameter of pipe 125 -150 mm |
| 030001D | Pick up from trench or chambers serviceable bitumen lined steel pipes, specials and fittings (excluding disconnection). Nominal diameter of pipe 200 mm |
| 030001E | Pick up from trench or chambers serviceable bitumen lined steel pipes, specials and fittings (excluding disconnection). Nominal diameter of pipe 250 mm |
| 030001F | Pick up from trench or chambers serviceable bitumen lined steel pipes, specials and fittings (excluding disconnection). Nominal diameter of pipe 300 - 350 mm |
| 030001G | Pick up from trench or chambers serviceable bitumen lined steel pipes, specials and fittings (excluding disconnection). Nominal diameter of pipe 400 mm |
| 030001H | Pick up from trench or chambers serviceable bitumen lined steel pipes, specials and fittings (excluding disconnection). Nominal diameter of pipe 450 - 525 mm |
| 030001I | Pick up from trench or chambers serviceable bitumen lined steel pipes, specials and fittings (excluding disconnection). Nominal diameter of pipe 600 - 675 mm |
| 030001J | Pick up from trench or chambers serviceable bitumen lined steel pipes, specials and fittings (excluding disconnection). Nominal diameter of pipe 700 - 750 mm |
| 030001K | Pick up from trench or chambers serviceable bitumen lined steel pipes, specials and fittings (excluding disconnection). Nominal diameter of pipe 800 mm |
| 030001L | Pick up from trench or chambers serviceable bitumen lined steel pipes, specials and fittings (excluding disconnection). Nominal diameter of pipe 900 mm |
| 030001M | Pick up from trench or chambers serviceable bitumen lined steel pipes, specials and fittings (excluding disconnection). Nominal diameter of pipe 1000 - 1100 mm |
| 030001N | Pick up from trench or chambers serviceable bitumen lined steel pipes, specials and fittings (excluding disconnection). Nominal diameter of pipe 1200 mm |
| 030001O | Pick up from trench or chambers serviceable bitumen lined steel pipes, specials and fittings (excluding disconnection). Nominal diameter of pipe 1350 - 1400 mm |
| 030001P | Pick up from trench or chambers serviceable bitumen lined steel pipes, specials and fittings (excluding disconnection). Nominal diameter of pipe 1600 mm |
| 030001Q | Pick up from trench or chambers serviceable bitumen lined steel pipes, specials and fittings (excluding disconnection). Nominal diameter of pipe 1800 mm |
| 030001R | Pick up from trench or chambers serviceable bitumen lined steel pipes, specials and fittings (excluding disconnection). Nominal diameter of pipe 1950 - 2100 mm |
| 030001S | Pick up from trench or chambers serviceable bitumen lined steel pipes, specials and fittings (excluding disconnection). Nominal diameter of pipe > 2100 mm |
| 030002B | As for Item No. 030/001 but concrete lined/epoxy coated steel pipes, specials and fittings. Nominal diameter of pipe 100 mm |
| 030002C | As for Item No. 030/001 but concrete lined/epoxy coated steel pipes, specials and fittings. Nominal diameter of pipe 125 -150 mm |
| 030002D | As for Item No. 030/001 but concrete lined/epoxy coated steel pipes, specials and fittings. Nominal diameter of pipe 200 mm |
| 030002E | As for Item No. 030/001 but concrete lined/epoxy coated steel pipes, specials and fittings. Nominal diameter of pipe 250 mm |
| 030002F | As for Item No. 030/001 but concrete lined/epoxy coated steel pipes, specials and fittings. Nominal diameter of pipe 300 - 350 mm |
| 030002G | As for Item No. 030/001 but concrete lined/epoxy coated steel pipes, specials and fittings. Nominal diameter of pipe 400 mm |
| 030002H | As for Item No. 030/001 but concrete lined/epoxy coated steel pipes, specials and fittings. Nominal diameter of pipe 450 - 525 mm |
| 030002I | As for Item No. 030/001 but concrete lined/epoxy coated steel pipes, specials and fittings. Nominal diameter of pipe 600 - 675 mm |
| 030002J | As for Item No. 030/001 but concrete lined/epoxy coated steel pipes, specials and fittings. Nominal diameter of pipe 700 - 750 mm |
| 030002K | As for Item No. 030/001 but concrete lined/epoxy coated steel pipes, specials and fittings. Nominal diameter of pipe 800 mm |
| 030002L | As for Item No. 030/001 but concrete lined/epoxy coated steel pipes, specials and fittings. Nominal diameter of pipe 900 mm |
| 030002M | As for Item No. 030/001 but concrete lined/epoxy coated steel pipes, specials and fittings. Nominal diameter of pipe 1000 - 1100 mm |
| 030002N | As for Item No. 030/001 but concrete lined/epoxy coated steel pipes, specials and fittings. Nominal diameter of pipe 1200 mm |
| 030002O | As for Item No. 030/001 but concrete lined/epoxy coated steel pipes, specials and fittings. Nominal diameter of pipe 1350 - 1400 mm |
| 030002P | As for Item No. 030/001 but concrete lined/epoxy coated steel pipes, specials and fittings. Nominal diameter of pipe 1600 mm |
| 030002Q | As for Item No. 030/001 but concrete lined/epoxy coated steel pipes, specials and fittings. Nominal diameter of pipe 1800 mm |
| 030002R | As for Item No. 030/001 but concrete lined/epoxy coated steel pipes, specials and fittings. Nominal diameter of pipe 1950 - 2100 mm |
| 030003A | As for Item No. 030/001 but cast iron pipes, specials and fittings. Nominal diameter of pipe 80 mm & under |
| 030003B | As for Item No. 030/001 but cast iron pipes, specials and fittings. Nominal diameter of pipe 100 mm |
| 030003C | As for Item No. 030/001 but cast iron pipes, specials and fittings. Nominal diameter of pipe 125 -150 mm |
| 030003D | As for Item No. 030/001 but cast iron pipes, specials and fittings. Nominal diameter of pipe 200 mm |
| 030003E | As for Item No. 030/001 but cast iron pipes, specials and fittings. Nominal diameter of pipe 250 mm |
| 030003F | As for Item No. 030/001 but cast iron pipes, specials and fittings. Nominal diameter of pipe 300 - 350 mm |
| 030003G | As for Item No. 030/001 but cast iron pipes, specials and fittings. Nominal diameter of pipe 400 mm |
| 030003H | As for Item No. 030/001 but cast iron pipes, specials and fittings. Nominal diameter of pipe 450 - 525 mm |
| 030003I | As for Item No. 030/001 but cast iron pipes, specials and fittings. Nominal diameter of pipe 600 - 675 mm |
| 030004A | As for Item No. 030/001 but ductile iron pipes, specials and fittings. Nominal diameter of pipe 80 mm & under |
| 030004B | As for Item No. 030/001 but ductile iron pipes, specials and fittings. Nominal diameter of pipe 100 mm |
| 030004C | As for Item No. 030/001 but ductile iron pipes, specials and fittings. Nominal diameter of pipe 125 -150 mm |
| 030004D | As for Item No. 030/001 but ductile iron pipes, specials and fittings. Nominal diameter of pipe 200 mm |
| 030004E | As for Item No. 030/001 but ductile iron pipes, specials and fittings. Nominal diameter of pipe 250 mm |
| 030004F | As for Item No. 030/001 but ductile iron pipes, specials and fittings. Nominal diameter of pipe 300 - 350 mm |
| 030004G | As for Item No. 030/001 but ductile iron pipes, specials and fittings. Nominal diameter of pipe 400 mm |
| 030004H | As for Item No. 030/001 but ductile iron pipes, specials and fittings. Nominal diameter of pipe 450 - 525 mm |
| 030004I | As for Item No. 030/001 but ductile iron pipes, specials and fittings. Nominal diameter of pipe 600 - 675 mm |
| 030004J | As for Item No. 030/001 but ductile iron pipes, specials and fittings. Nominal diameter of pipe 700 - 750 mm |
| 030004K | As for Item No. 030/001 but ductile iron pipes, specials and fittings. Nominal diameter of pipe 800 mm |
| 030004L | As for Item No. 030/001 but ductile iron pipes, specials and fittings. Nominal diameter of pipe 900 mm |
| 030004M | As for Item No. 030/001 but ductile iron pipes, specials and fittings. Nominal diameter of pipe 1000 - 1100 mm |
| 030006A | As for Item No. 030/001 but sluice, gate, reflux, butterfly, air valve or flowmeter. Nominal diameter of pipe 80 mm & under |
| 030006B | As for Item No. 030/001 but sluice, gate, reflux, butterfly, air valve or flowmeter. Nominal diameter of pipe 100 mm |
| 030006C | As for Item No. 030/001 but sluice, gate, reflux, butterfly, air valve or flowmeter. Nominal diameter of pipe 125 -150 mm |
| 030006D | As for Item No. 030/001 but sluice, gate, reflux, butterfly, air valve or flowmeter. Nominal diameter of pipe 200 mm |
| 030006E | As for Item No. 030/001 but sluice, gate, reflux, butterfly, air valve or flowmeter. Nominal diameter of pipe 250 mm |
| 030006F | As for Item No. 030/001 but sluice, gate, reflux, butterfly, air valve or flowmeter. Nominal diameter of pipe 300 - 350 mm |
| 030006G | As for Item No. 030/001 but sluice, gate, reflux, butterfly, air valve or flowmeter. Nominal diameter of pipe 400 mm |
| 030006H | As for Item No. 030/001 but sluice, gate, reflux, butterfly, air valve or flowmeter. Nominal diameter of pipe 450 - 525 mm |
| 030006I | As for Item No. 030/001 but sluice, gate, reflux, butterfly, air valve or flowmeter. Nominal diameter of pipe 600 - 675 mm |
| 030006J | As for Item No. 030/001 but sluice, gate, reflux, butterfly, air valve or flowmeter. Nominal diameter of pipe 700 - 750 mm |
| 030006K | As for Item No. 030/001 but sluice, gate, reflux, butterfly, air valve or flowmeter. Nominal diameter of pipe 800 mm |
| 030006L | As for Item No. 030/001 but sluice, gate, reflux, butterfly, air valve or flowmeter. Nominal diameter of pipe 900 mm |
| 030006M | As for Item No. 030/001 but sluice, gate, reflux, butterfly, air valve or flowmeter. Nominal diameter of pipe 1000 - 1100 mm |
| 030006N | As for Item No. 030/001 but sluice, gate, reflux, butterfly, air valve or flowmeter. Nominal diameter of pipe 1200 mm |
| 030006O | As for Item No. 030/001 but sluice, gate, reflux, butterfly, air valve or flowmeter. Nominal diameter of pipe 1350 - 1400 mm |
| 030006P | As for Item No. 030/001 but sluice, gate, reflux, butterfly, air valve or flowmeter. Nominal diameter of pipe 1600 mm |
| 030006Q | As for Item No. 030/001 but sluice, gate, reflux, butterfly, air valve or flowmeter. Nominal diameter of pipe 1800 mm |
| 030006R | As for Item No. 030/001 but sluice, gate, reflux, butterfly, air valve or flowmeter. Nominal diameter of pipe 1950 - 2100 mm |
| 030007A | Pick up from trench or chambers serviceable U.P.V.C. pipes, specials and fittings. Nominal diameter of pipe 15 mm |
| 030007B | Pick up from trench or chambers serviceable U.P.V.C. pipes, specials and fittings. Nominal diameter of pipe 20 mm |
| 030007C | Pick up from trench or chambers serviceable U.P.V.C. pipes, specials and fittings. Nominal diameter of pipe 25 mm |
| 030007D | Pick up from trench or chambers serviceable U.P.V.C. pipes, specials and fittings. Nominal diameter of pipe 40 mm |
| 030007E | Pick up from trench or chambers serviceable U.P.V.C. pipes, specials and fittings. Nominal diameter of pipe 50 mm |
| 030007F | Pick up from trench or chambers serviceable U.P.V.C. pipes, specials and fittings. Nominal diameter of pipe 80 mm |
| 030007G | Pick up from trench or chambers serviceable U.P.V.C. pipes, specials and fittings. Nominal diameter of pipe 100mm |
| 030007H | Pick up from trench or chambers serviceable U.P.V.C. pipes, specials and fittings. Nominal diameter of pipe 150mm |
| 030007I | Pick up from trench or chambers serviceable U.P.V.C. pipes, specials and fittings. Nominal diameter of pipe 200mm |
| 030007J | Pick up from trench or chambers serviceable U.P.V.C. pipes, specials and fittings. Nominal diameter of pipe 250mm |
| 030008A | Pick up from trench or chambers serviceable G.I. pipes, specials and fittings. Nominal diameter of pipe 15 mm |
| 030008B | Pick up from trench or chambers serviceable G.I. pipes, specials and fittings. Nominal diameter of pipe 20 mm |
| 030008C | Pick up from trench or chambers serviceable G.I. pipes, specials and fittings. Nominal diameter of pipe 25 mm |
| 030008D | Pick up from trench or chambers serviceable G.I. pipes, specials and fittings. Nominal diameter of pipe 40 mm |
| 030008E | Pick up from trench or chambers serviceable G.I. pipes, specials and fittings. Nominal diameter of pipe 50 mm |
| 030008F | Pick up from trench or chambers serviceable G.I. pipes, specials and fittings. Nominal diameter of pipe 80 mm |
| 030008G | Pick up from trench or chambers serviceable G.I. pipes, specials and fittings. Nominal diameter of pipe 100mm |
| 030008H | Pick up from trench or chambers serviceable G.I. pipes, specials and fittings. Nominal diameter of pipe 150mm |
| 030009 | Pick up 150 mm (6 in) pedestal fire hydrant. |
| 030010 | Pick up heavy draw-off fire hydrant. |
| 030011 | Pick up swan neck hydrant. |
| 030012 | Installation of 150 mm (6 in) pedestal hydrant. |
| 030013 | Installation of swan neck hydrant. |
| 030014 | Installation of heavy draw-off hydrant as shown in Drawing No. SK 957 (from the flange of the bolted gland socket/flange adaptor onward). |
| 030015 | Installation of type I (DN 100) DI fire hydrant cap. |
| 030016 | Installation of type II (DN 80) DI fire hydrant cap. |
| 030017 | Supply identification tapes for water mains as shown in Drawing No. WSD 1.31. |
| 030018 | Supply and lay identification tapes for water mains as shown in Drawing No. WSD 1.31. |
| 030019A | Clean thoroughly the inside and outside of site serviceable bitumen lined steel pipes or GRP pipes, specials and fittings. Nominal diameter of pipe 80mm & under |
| 030019B | Clean thoroughly the inside and outside of site serviceable bitumen lined steel pipes or GRP pipes, specials and fittings. Nominal diameter of pipe 100mm |
| 030019C | Clean thoroughly the inside and outside of site serviceable bitumen lined steel pipes or GRP pipes, specials and fittings. Nominal diameter of pipe 125 -150mm |
| 030019D | Clean thoroughly the inside and outside of site serviceable bitumen lined steel pipes or GRP pipes, specials and fittings. Nominal diameter of pipe 200mm |
| 030019E | Clean thoroughly the inside and outside of site serviceable bitumen lined steel pipes or GRP pipes, specials and fittings. Nominal diameter of pipe 250mm |
| 030019F | Clean thoroughly the inside and outside of site serviceable bitumen lined steel pipes or GRP pipes, specials and fittings. Nominal diameter of pipe 300 - 350mm |
| 030019G | Clean thoroughly the inside and outside of site serviceable bitumen lined steel pipes or GRP pipes, specials and fittings. Nominal diameter of pipe 400mm |
| 030019H | Clean thoroughly the inside and outside of site serviceable bitumen lined steel pipes or GRP pipes, specials and fittings. Nominal diameter of pipe 450 - 525mm |
| 030019I | Clean thoroughly the inside and outside of site serviceable bitumen lined steel pipes or GRP pipes, specials and fittings. Nominal diameter of pipe 600 - 675mm |
| 030019J | Clean thoroughly the inside and outside of site serviceable bitumen lined steel pipes or GRP pipes, specials and fittings. Nominal diameter of pipe 700 - 750mm |
| 030019K | Clean thoroughly the inside and outside of site serviceable bitumen lined steel pipes or GRP pipes, specials and fittings. Nominal diameter of pipe 800 mm |
| 030019L | Clean thoroughly the inside and outside of site serviceable bitumen lined steel pipes or GRP pipes, specials and fittings. Nominal diameter of pipe 900 mm |
| 030019M | Clean thoroughly the inside and outside of site serviceable bitumen lined steel pipes or GRP pipes, specials and fittings. Nominal diameter of pipe 1000 - 1100 mm |
| 030019N | Clean thoroughly the inside and outside of site serviceable bitumen lined steel pipes or GRP pipes, specials and fittings. Nominal diameter of pipe 1200 mm |
| 030019O | Clean thoroughly the inside and outside of site serviceable bitumen lined steel pipes or GRP pipes, specials and fittings. Nominal diameter of pipe 1350 - 1400 mm |
| 030019P | Clean thoroughly the inside and outside of site serviceable bitumen lined steel pipes or GRP pipes, specials and fittings. Nominal diameter of pipe 1600 mm |
| 030019Q | Clean thoroughly the inside and outside of site serviceable bitumen lined steel pipes or GRP pipes, specials and fittings. Nominal diameter of pipe 1800 mm |
| 030019R | Clean thoroughly the inside and outside of site serviceable bitumen lined steel pipes or GRP pipes, specials and fittings. Nominal diameter of pipe 1950 - 2100 mm |
| 030019S | Clean thoroughly the inside and outside of site serviceable bitumen lined steel pipes or GRP pipes, specials and fittings. Nominal diameter of pipe > 2100 mm |
| 030020A | As for Item No. 030/019 but concrete lined steel pipes, specials and fittings. Nominal diameter of pipe 80mm & under |
| 030020B | As for Item No. 030/019 but concrete lined steel pipes, specials and fittings. Nominal diameter of pipe 100mm |
| 030020C | As for Item No. 030/019 but concrete lined steel pipes, specials and fittings. Nominal diameter of pipe 125 -150mm |
| 030020D | As for Item No. 030/019 but concrete lined steel pipes, specials and fittings. Nominal diameter of pipe 200mm |
| 030020E | As for Item No. 030/019 but concrete lined steel pipes, specials and fittings. Nominal diameter of pipe 250mm |
| 030020F | As for Item No. 030/019 but concrete lined steel pipes, specials and fittings. Nominal diameter of pipe 300 - 350mm |
| 030020G | As for Item No. 030/019 but concrete lined steel pipes, specials and fittings. Nominal diameter of pipe 400mm |
| 030020H | As for Item No. 030/019 but concrete lined steel pipes, specials and fittings. Nominal diameter of pipe 450 - 525mm |
| 030020I | As for Item No. 030/019 but concrete lined steel pipes, specials and fittings. Nominal diameter of pipe 600 - 675mm |
| 030020J | As for Item No. 030/019 but concrete lined steel pipes, specials and fittings. Nominal diameter of pipe 700 - 750mm |
| 030020K | As for Item No. 030/019 but concrete lined steel pipes, specials and fittings. Nominal diameter of pipe 800 mm |
| 030020L | As for Item No. 030/019 but concrete lined steel pipes, specials and fittings. Nominal diameter of pipe 900 mm |
| 030020M | As for Item No. 030/019 but concrete lined steel pipes, specials and fittings. Nominal diameter of pipe 1000 - 1100 mm |
| 030020N | As for Item No. 030/019 but concrete lined steel pipes, specials and fittings. Nominal diameter of pipe 1200 mm |
| 030020O | As for Item No. 030/019 but concrete lined steel pipes, specials and fittings. Nominal diameter of pipe 1350 - 1400 mm |
| 030020P | As for Item No. 030/019 but concrete lined steel pipes, specials and fittings. Nominal diameter of pipe 1600 mm |
| 030021A | As for Item No. 030/019 but cast iron pipes, specials and fittings. Nominal diameter of pipe 80mm & under |
| 030021B | As for Item No. 030/019 but cast iron pipes, specials and fittings. Nominal diameter of pipe 100mm |
| 030021C | As for Item No. 030/019 but cast iron pipes, specials and fittings. Nominal diameter of pipe 125 -150mm |
| 030021D | As for Item No. 030/019 but cast iron pipes, specials and fittings. Nominal diameter of pipe 200mm |
| 030021E | As for Item No. 030/019 but cast iron pipes, specials and fittings. Nominal diameter of pipe 250mm |
| 030021F | As for Item No. 030/019 but cast iron pipes, specials and fittings. Nominal diameter of pipe 300 - 350mm |
| 030021G | As for Item No. 030/019 but cast iron pipes, specials and fittings. Nominal diameter of pipe 400mm |
| 030021H | As for Item No. 030/019 but cast iron pipes, specials and fittings. Nominal diameter of pipe 450 - 525mm |
| 030021I | As for Item No. 030/019 but cast iron pipes, specials and fittings. Nominal diameter of pipe 600 - 675mm |
| 030022A | As for Item No. 030/019 but ductile iron pipes, specials and fittings. Nominal diameter of pipe 80mm & under |
| 030022B | As for Item No. 030/019 but ductile iron pipes, specials and fittings. Nominal diameter of pipe 100mm |
| 030022C | As for Item No. 030/019 but ductile iron pipes, specials and fittings. Nominal diameter of pipe 125 -150mm |
| 030022D | As for Item No. 030/019 but ductile iron pipes, specials and fittings. Nominal diameter of pipe 200mm |
| 030022E | As for Item No. 030/019 but ductile iron pipes, specials and fittings. Nominal diameter of pipe 250mm |
| 030022F | As for Item No. 030/019 but ductile iron pipes, specials and fittings. Nominal diameter of pipe 300 - 350mm |
| 030022G | As for Item No. 030/019 but ductile iron pipes, specials and fittings. Nominal diameter of pipe 400mm |
| 030022H | As for Item No. 030/019 but ductile iron pipes, specials and fittings. Nominal diameter of pipe 450 - 525mm |
| 030022I | As for Item No. 030/019 but ductile iron pipes, specials and fittings. Nominal diameter of pipe 600 - 675mm |
| 030022J | As for Item No. 030/019 but ductile iron pipes, specials and fittings. Nominal diameter of pipe 700 - 750mm |
| 030022K | As for Item No. 030/019 but ductile iron pipes, specials and fittings. Nominal diameter of pipe 800 mm |
| 030022L | As for Item No. 030/019 but ductile iron pipes, specials and fittings. Nominal diameter of pipe 900 mm |
| 030022M | As for Item No. 030/019 but ductile iron pipes, specials and fittings. Nominal diameter of pipe 1000 - 1100 mm |
| 030024A | Disconnect lead joint. Nominal diameter of pipe 80mm & under |
| 030024B | Disconnect lead joint. Nominal diameter of pipe 100mm |
| 030024C | Disconnect lead joint. Nominal diameter of pipe 125 -150mm |
| 030024D | Disconnect lead joint. Nominal diameter of pipe 200mm |
| 030024E | Disconnect lead joint. Nominal diameter of pipe 250mm |
| 030024F | Disconnect lead joint. Nominal diameter of pipe 300 - 350mm |
| 030024G | Disconnect lead joint. Nominal diameter of pipe 400mm |
| 030024H | Disconnect lead joint. Nominal diameter of pipe 450 - 525mm |
| 030024I | Disconnect lead joint. Nominal diameter of pipe 600 - 675mm |
| 030024J | Disconnect lead joint. Nominal diameter of pipe 700 - 750mm |
| 030024K | Disconnect lead joint. Nominal diameter of pipe 800 mm |
| 030024L | Disconnect lead joint. Nominal diameter of pipe 900 mm |
| 030024M | Disconnect lead joint. Nominal diameter of pipe 1000 - 1100 mm |
| 030024N | Disconnect lead joint. Nominal diameter of pipe 1200 mm |
| 030024O | Disconnect lead joint. Nominal diameter of pipe 1350 - 1400 mm |
| 030024P | Disconnect lead joint. Nominal diameter of pipe 1600 mm |
| 030025A | Disconnect flanged joint. Nominal diameter of pipe 80mm & under |
| 030025B | Disconnect flanged joint. Nominal diameter of pipe 100mm |
| 030025C | Disconnect flanged joint. Nominal diameter of pipe 125 -150mm |
| 030025D | Disconnect flanged joint. Nominal diameter of pipe 200mm |
| 030025E | Disconnect flanged joint. Nominal diameter of pipe 250mm |
| 030025F | Disconnect flanged joint. Nominal diameter of pipe 300 - 350mm |
| 030025G | Disconnect flanged joint. Nominal diameter of pipe 400mm |
| 030025H | Disconnect flanged joint. Nominal diameter of pipe 450 - 525mm |
| 030025I | Disconnect flanged joint. Nominal diameter of pipe 600 - 675mm |
| 030025J | Disconnect flanged joint. Nominal diameter of pipe 700 - 750mm |
| 030025K | Disconnect flanged joint. Nominal diameter of pipe 800 mm |
| 030025L | Disconnect flanged joint. Nominal diameter of pipe 900 mm |
| 030025M | Disconnect flanged joint. Nominal diameter of pipe 1000 - 1100 mm |
| 030025N | Disconnect flanged joint. Nominal diameter of pipe 1200 mm |
| 030025O | Disconnect flanged joint. Nominal diameter of pipe 1350 - 1400 mm |
| 030025P | Disconnect flanged joint. Nominal diameter of pipe 1600 mm |
| 030025Q | Disconnect flanged joint. Nominal diameter of pipe 1800 mm |
| 030025R | Disconnect flanged joint. Nominal diameter of pipe 1950 - 2100 mm |
| 030025S | Disconnect flanged joint. Nominal diameter of pipe > 2100 mm |
| 030026A | Disconnect screw joint. Nominal diameter of pipe 80mm & under |
| 030026B | Disconnect screw joint. Nominal diameter of pipe 100mm |
| 030026C | Disconnect screw joint. Nominal diameter of pipe 125 -150mm |
| 030026D | Disconnect screw joint. Nominal diameter of pipe 200mm |
| 030026E | Disconnect screw joint. Nominal diameter of pipe 250mm |
| 030026F | Disconnect screw joint. Nominal diameter of pipe 300 - 350mm |
| 030026G | Disconnect screw joint. Nominal diameter of pipe 400mm |
| 030026H | Disconnect screw joint. Nominal diameter of pipe 450 - 525mm |
| 030026I | Disconnect screw joint. Nominal diameter of pipe 600 - 675mm |
| 030027A | Disconnect detachable, screw gland or bolted joint including mechanical flexible type for ductile iron pipe. Nominal diameter of pipe 80mm & under |
| 030027B | Disconnect detachable, screw gland or bolted joint including mechanical flexible type for ductile iron pipe. Nominal diameter of pipe 100mm |
| 030027C | Disconnect detachable, screw gland or bolted joint including mechanical flexible type for ductile iron pipe. Nominal diameter of pipe 125 -150mm |
| 030027D | Disconnect detachable, screw gland or bolted joint including mechanical flexible type for ductile iron pipe. Nominal diameter of pipe 200mm |
| 030027E | Disconnect detachable, screw gland or bolted joint including mechanical flexible type for ductile iron pipe. Nominal diameter of pipe 250mm |
| 030027F | Disconnect detachable, screw gland or bolted joint including mechanical flexible type for ductile iron pipe. Nominal diameter of pipe 300 - 350mm |
| 030027G | Disconnect detachable, screw gland or bolted joint including mechanical flexible type for ductile iron pipe. Nominal diameter of pipe 400mm |
| 030027H | Disconnect detachable, screw gland or bolted joint including mechanical flexible type for ductile iron pipe. Nominal diameter of pipe 450 - 525mm |
| 030027I | Disconnect detachable, screw gland or bolted joint including mechanical flexible type for ductile iron pipe. Nominal diameter of pipe 600 - 675mm |
| 030027J | Disconnect detachable, screw gland or bolted joint including mechanical flexible type for ductile iron pipe. Nominal diameter of pipe 700 - 750mm |
| 030027K | Disconnect detachable, screw gland or bolted joint including mechanical flexible type for ductile iron pipe. Nominal diameter of pipe 800 mm |
| 030027L | Disconnect detachable, screw gland or bolted joint including mechanical flexible type for ductile iron pipe. Nominal diameter of pipe 900 mm |
| 030027M | Disconnect detachable, screw gland or bolted joint including mechanical flexible type for ductile iron pipe. Nominal diameter of pipe 1000 - 1100 mm |
| 030028A | Disconnect 'Tyton' joint or automatic coupling joint, including push-in type for ductile iron pipe. Nominal diameter of pipe 80mm & under |
| 030028B | Disconnect 'Tyton' joint or automatic coupling joint, including push-in type for ductile iron pipe. Nominal diameter of pipe 100mm |
| 030028C | Disconnect 'Tyton' joint or automatic coupling joint, including push-in type for ductile iron pipe. Nominal diameter of pipe 125 -150mm |
| 030028D | Disconnect 'Tyton' joint or automatic coupling joint, including push-in type for ductile iron pipe. Nominal diameter of pipe 200mm |
| 030028E | Disconnect 'Tyton' joint or automatic coupling joint, including push-in type for ductile iron pipe. Nominal diameter of pipe 250mm |
| 030028F | Disconnect 'Tyton' joint or automatic coupling joint, including push-in type for ductile iron pipe. Nominal diameter of pipe 300 - 350mm |
| 030028G | Disconnect 'Tyton' joint or automatic coupling joint, including push-in type for ductile iron pipe. Nominal diameter of pipe 400mm |
| 030028H | Disconnect 'Tyton' joint or automatic coupling joint, including push-in type for ductile iron pipe. Nominal diameter of pipe 450 - 525mm |
| 030028I | Disconnect 'Tyton' joint or automatic coupling joint, including push-in type for ductile iron pipe. Nominal diameter of pipe 600 - 675mm |
| 030029C | Disconnect 'Johnson' coupling joint. Nominal diameter of pipe 125 -150mm |
| 030029D | Disconnect 'Johnson' coupling joint. Nominal diameter of pipe 200mm |
| 030029E | Disconnect 'Johnson' coupling joint. Nominal diameter of pipe 250mm |
| 030029F | Disconnect 'Johnson' coupling joint. Nominal diameter of pipe 300 - 350mm |
| 030029G | Disconnect 'Johnson' coupling joint. Nominal diameter of pipe 400mm |
| 030029H | Disconnect 'Johnson' coupling joint. Nominal diameter of pipe 450 - 525mm |
| 030029I | Disconnect 'Johnson' coupling joint. Nominal diameter of pipe 600 - 675mm |
| 030029J | Disconnect 'Johnson' coupling joint. Nominal diameter of pipe 700 - 750mm |
| 030029K | Disconnect 'Johnson' coupling joint. Nominal diameter of pipe 800 mm |
| 030029L | Disconnect 'Johnson' coupling joint. Nominal diameter of pipe 900 mm |
| 030029M | Disconnect 'Johnson' coupling joint. Nominal diameter of pipe 1000 - 1100 mm |
| 030029N | Disconnect 'Johnson' coupling joint. Nominal diameter of pipe 1200 mm |
| 030029O | Disconnect 'Johnson' coupling joint. Nominal diameter of pipe 1350 - 1400 mm |
| 030029P | Disconnect 'Johnson' coupling joint. Nominal diameter of pipe 1600 mm |
| 030029Q | Disconnect 'Johnson' coupling joint. Nominal diameter of pipe 1800 mm |
| 030029R | Disconnect 'Johnson' coupling joint. Nominal diameter of pipe 1950 - 2100 mm |
| 030029S | Disconnect 'Johnson' coupling joint. Nominal diameter of pipe > 2100 mm |
| 030030C | Disconnect 'Johnson' flange joint. Nominal diameter of pipe 125 -150mm |
| 030030D | Disconnect 'Johnson' flange joint. Nominal diameter of pipe 200mm |
| 030030E | Disconnect 'Johnson' flange joint. Nominal diameter of pipe 250mm |
| 030030F | Disconnect 'Johnson' flange joint. Nominal diameter of pipe 300 - 350mm |
| 030030G | Disconnect 'Johnson' flange joint. Nominal diameter of pipe 400mm |
| 030030H | Disconnect 'Johnson' flange joint. Nominal diameter of pipe 450 - 525mm |
| 030030I | Disconnect 'Johnson' flange joint. Nominal diameter of pipe 600 - 675mm |
| 030030J | Disconnect 'Johnson' flange joint. Nominal diameter of pipe 700 - 750mm |
| 030030K | Disconnect 'Johnson' flange joint. Nominal diameter of pipe 800 mm |
| 030030L | Disconnect 'Johnson' flange joint. Nominal diameter of pipe 900 mm |
| 030030M | Disconnect 'Johnson' flange joint. Nominal diameter of pipe 1000 - 1100 mm |
| 030030N | Disconnect 'Johnson' flange joint. Nominal diameter of pipe 1200 mm |
| 030030O | Disconnect 'Johnson' flange joint. Nominal diameter of pipe 1350 - 1400 mm |
| 030030P | Disconnect 'Johnson' flange joint. Nominal diameter of pipe 1600 mm |
| 030030Q | Disconnect 'Johnson' flange joint. Nominal diameter of pipe 1800 mm |
| 030030R | Disconnect 'Johnson' flange joint. Nominal diameter of pipe 1950 - 2100 mm |
| 030030S | Disconnect 'Johnson' flange joint. Nominal diameter of pipe > 2100 mm |
| 030031A | Disconnect Victaulic joint. Nominal diameter of pipe 80mm & under |
| 030031B | Disconnect Victaulic joint. Nominal diameter of pipe 100mm |
| 030031C | Disconnect Victaulic joint. Nominal diameter of pipe 125 -150mm |
| 030031D | Disconnect Victaulic joint. Nominal diameter of pipe 200mm |
| 030031E | Disconnect Victaulic joint. Nominal diameter of pipe 250mm |
| 030031F | Disconnect Victaulic joint. Nominal diameter of pipe 300 - 350mm |
| 030031G | Disconnect Victaulic joint. Nominal diameter of pipe 400mm |
| 030031H | Disconnect Victaulic joint. Nominal diameter of pipe 450 - 525mm |
| 030031I | Disconnect Victaulic joint. Nominal diameter of pipe 600 - 675mm |
| 030031J | Disconnect Victaulic joint. Nominal diameter of pipe 700 - 750mm |
| 030031K | Disconnect Victaulic joint. Nominal diameter of pipe 800 mm |
| 030031L | Disconnect Victaulic joint. Nominal diameter of pipe 900 mm |
| 030032C | Strip external bituminous protection to pipes. Nominal diameter of pipe 125 -150mm |
| 030032D | Strip external bituminous protection to pipes. Nominal diameter of pipe 200mm |
| 030032E | Strip external bituminous protection to pipes. Nominal diameter of pipe 250mm |
| 030032F | Strip external bituminous protection to pipes. Nominal diameter of pipe 300 - 350mm |
| 030032G | Strip external bituminous protection to pipes. Nominal diameter of pipe 400mm |
| 030032H | Strip external bituminous protection to pipes. Nominal diameter of pipe 450 - 525mm |
| 030032I | Strip external bituminous protection to pipes. Nominal diameter of pipe 600 - 675mm |
| 030032J | Strip external bituminous protection to pipes. Nominal diameter of pipe 700 - 750mm |
| 030032K | Strip external bituminous protection to pipes. Nominal diameter of pipe 800 mm |
| 030032L | Strip external bituminous protection to pipes. Nominal diameter of pipe 900 mm |
| 030032M | Strip external bituminous protection to pipes. Nominal diameter of pipe 1000 - 1100 mm |
| 030032N | Strip external bituminous protection to pipes. Nominal diameter of pipe 1200 mm |
| 030032O | Strip external bituminous protection to pipes. Nominal diameter of pipe 1350 - 1400 mm |
| 030032P | Strip external bituminous protection to pipes. Nominal diameter of pipe 1600 mm |
| 030032Q | Strip external bituminous protection to pipes. Nominal diameter of pipe 1800 mm |
| 030032R | Strip external bituminous protection to pipes. Nominal diameter of pipe 1950 - 2100 mm |
| 030032S | Strip external bituminous protection to pipes. Nominal diameter of pipe > 2100 mm |
| 030033I | Strip internal bituminous lining to pipes. Nominal diameter of pipe 600 - 675mm |
| 030033J | Strip internal bituminous lining to pipes. Nominal diameter of pipe 700 - 750mm |
| 030033K | Strip internal bituminous lining to pipes. Nominal diameter of pipe 800 mm |
| 030033L | Strip internal bituminous lining to pipes. Nominal diameter of pipe 900 mm |
| 030033M | Strip internal bituminous lining to pipes. Nominal diameter of pipe 1000 - 1100 mm |
| 030033N | Strip internal bituminous lining to pipes. Nominal diameter of pipe 1200 mm |
| 030033O | Strip internal bituminous lining to pipes. Nominal diameter of pipe 1350 - 1400 mm |
| 030033P | Strip internal bituminous lining to pipes. Nominal diameter of pipe 1600 mm |
| 030033Q | Strip internal bituminous lining to pipes. Nominal diameter of pipe 1800 mm |
| 030033R | Strip internal bituminous lining to pipes. Nominal diameter of pipe 1950 - 2100 mm |
| 030033S | Strip internal bituminous lining to pipes. Nominal diameter of pipe > 2100 mm |
| 030034I | Sand blast steel pipe external surface with steel grits to remove rust. Nominal diameter of pipe 600 - 675mm |
| 030034J | Sand blast steel pipe external surface with steel grits to remove rust. Nominal diameter of pipe 700 - 750mm |
| 030034K | Sand blast steel pipe external surface with steel grits to remove rust. Nominal diameter of pipe 800 mm |
| 030034L | Sand blast steel pipe external surface with steel grits to remove rust. Nominal diameter of pipe 900 mm |
| 030034M | Sand blast steel pipe external surface with steel grits to remove rust. Nominal diameter of pipe 1000 - 1100 mm |
| 030034N | Sand blast steel pipe external surface with steel grits to remove rust. Nominal diameter of pipe 1200 mm |
| 030034O | Sand blast steel pipe external surface with steel grits to remove rust. Nominal diameter of pipe 1350 - 1400 mm |
| 030034P | Sand blast steel pipe external surface with steel grits to remove rust. Nominal diameter of pipe 1600 mm |
| 030034Q | Sand blast steel pipe external surface with steel grits to remove rust. Nominal diameter of pipe 1800 mm |
| 030034R | Sand blast steel pipe external surface with steel grits to remove rust. Nominal diameter of pipe 1950 - 2100 mm |
| 030034S | Sand blast steel pipe external surface with steel grits to remove rust. Nominal diameter of pipe > 2100 mm |
| 030035I | Sand blast steel pipe internal surface with steel grits to remove rust. Nominal diameter of pipe 600 - 675mm |
| 030035J | Sand blast steel pipe internal surface with steel grits to remove rust. Nominal diameter of pipe 700 - 750mm |
| 030035K | Sand blast steel pipe internal surface with steel grits to remove rust. Nominal diameter of pipe 800 mm |
| 030035L | Sand blast steel pipe internal surface with steel grits to remove rust. Nominal diameter of pipe 900 mm |
| 030035M | Sand blast steel pipe internal surface with steel grits to remove rust. Nominal diameter of pipe 1000 - 1100 mm |
| 030035N | Sand blast steel pipe internal surface with steel grits to remove rust. Nominal diameter of pipe 1200 mm |
| 030035O | Sand blast steel pipe internal surface with steel grits to remove rust. Nominal diameter of pipe 1350 - 1400 mm |
| 030035P | Sand blast steel pipe internal surface with steel grits to remove rust. Nominal diameter of pipe 1600 mm |
| 030035Q | Sand blast steel pipe internal surface with steel grits to remove rust. Nominal diameter of pipe 1800 mm |
| 030035R | Sand blast steel pipe internal surface with steel grits to remove rust. Nominal diameter of pipe 1950 - 2100 mm |
| 030035S | Sand blast steel pipe internal surface with steel grits to remove rust. Nominal diameter of pipe > 2100 mm |
| 030036A | Make internal protection to steel pipe joints, or cement mortar in the case of concrete lined pipes. Nominal diameter of pipe 80mm & under |
| 030036B | Make internal protection to steel pipe joints, or cement mortar in the case of concrete lined pipes. Nominal diameter of pipe 100mm |
| 030036C | Make internal protection to steel pipe joints, or cement mortar in the case of concrete lined pipes. Nominal diameter of pipe 125 -150mm |
| 030036D | Make internal protection to steel pipe joints, or cement mortar in the case of concrete lined pipes. Nominal diameter of pipe 200mm |
| 030036E | Make internal protection to steel pipe joints, or cement mortar in the case of concrete lined pipes. Nominal diameter of pipe 250mm |
| 030036F | Make internal protection to steel pipe joints, or cement mortar in the case of concrete lined pipes. Nominal diameter of pipe 300 - 350mm |
| 030036G | Make internal protection to steel pipe joints, or cement mortar in the case of concrete lined pipes. Nominal diameter of pipe 400mm |
| 030036H | Make internal protection to steel pipe joints, or cement mortar in the case of concrete lined pipes. Nominal diameter of pipe 450 - 525mm |
| 030036I | Make internal protection to steel pipe joints, or cement mortar in the case of concrete lined pipes. Nominal diameter of pipe 600 - 675mm |
| 030036J | Make internal protection to steel pipe joints, or cement mortar in the case of concrete lined pipes. Nominal diameter of pipe 700 - 750mm |
| 030036K | Make internal protection to steel pipe joints, or cement mortar in the case of concrete lined pipes. Nominal diameter of pipe 800 mm |
| 030036L | Make internal protection to steel pipe joints, or cement mortar in the case of concrete lined pipes. Nominal diameter of pipe 900 mm |
| 030036M | Make internal protection to steel pipe joints, or cement mortar in the case of concrete lined pipes. Nominal diameter of pipe 1000 - 1100 mm |
| 030036N | Make internal protection to steel pipe joints, or cement mortar in the case of concrete lined pipes. Nominal diameter of pipe 1200 mm |
| 030036O | Make internal protection to steel pipe joints, or cement mortar in the case of concrete lined pipes. Nominal diameter of pipe 1350 - 1400 mm |
| 030036P | Make internal protection to steel pipe joints, or cement mortar in the case of concrete lined pipes. Nominal diameter of pipe 1600 mm |
| 030036Q | Make internal protection to steel pipe joints, or cement mortar in the case of concrete lined pipes. Nominal diameter of pipe 1800 mm |
| 030036R | Make internal protection to steel pipe joints, or cement mortar in the case of concrete lined pipes. Nominal diameter of pipe 1950 - 2100 mm |
| 030036S | Make internal protection to steel pipe joints, or cement mortar in the case of concrete lined pipes. Nominal diameter of pipe > 2100 mm |
| 030037B | Make external protection to steel pipe joints with bitumen coatings. Nominal diameter of pipe 100mm |
| 030037C | Make external protection to steel pipe joints with bitumen coatings. Nominal diameter of pipe 125 -150mm |
| 030037D | Make external protection to steel pipe joints with bitumen coatings. Nominal diameter of pipe 200mm |
| 030037E | Make external protection to steel pipe joints with bitumen coatings. Nominal diameter of pipe 250mm |
| 030037F | Make external protection to steel pipe joints with bitumen coatings. Nominal diameter of pipe 300 - 350mm |
| 030037G | Make external protection to steel pipe joints with bitumen coatings. Nominal diameter of pipe 400mm |
| 030037H | Make external protection to steel pipe joints with bitumen coatings. Nominal diameter of pipe 450 - 525mm |
| 030037I | Make external protection to steel pipe joints with bitumen coatings. Nominal diameter of pipe 600 - 675mm |
| 030037J | Make external protection to steel pipe joints with bitumen coatings. Nominal diameter of pipe 700 - 750mm |
| 030037K | Make external protection to steel pipe joints with bitumen coatings. Nominal diameter of pipe 800 mm |
| 030037L | Make external protection to steel pipe joints with bitumen coatings. Nominal diameter of pipe 900 mm |
| 030037M | Make external protection to steel pipe joints with bitumen coatings. Nominal diameter of pipe 1000 - 1100 mm |
| 030037N | Make external protection to steel pipe joints with bitumen coatings. Nominal diameter of pipe 1200 mm |
| 030037O | Make external protection to steel pipe joints with bitumen coatings. Nominal diameter of pipe 1350 - 1400 mm |
| 030037P | Make external protection to steel pipe joints with bitumen coatings. Nominal diameter of pipe 1600 mm |
| 030037Q | Make external protection to steel pipe joints with bitumen coatings. Nominal diameter of pipe 1800 mm |
| 030037R | Make external protection to steel pipe joints with bitumen coatings. Nominal diameter of pipe 1950 - 2100 mm |
| 030037S | Make external protection to steel pipe joints with bitumen coatings. Nominal diameter of pipe > 2100 mm |
| 030038B | Make external protection to steel pipe joints using bituminous anti-corrosion tape. Nominal diameter of pipe 100mm |
| 030038C | Make external protection to steel pipe joints using bituminous anti-corrosion tape. Nominal diameter of pipe 125 -150mm |
| 030038D | Make external protection to steel pipe joints using bituminous anti-corrosion tape. Nominal diameter of pipe 200mm |
| 030038E | Make external protection to steel pipe joints using bituminous anti-corrosion tape. Nominal diameter of pipe 250mm |
| 030038F | Make external protection to steel pipe joints using bituminous anti-corrosion tape. Nominal diameter of pipe 300 - 350mm |
| 030038G | Make external protection to steel pipe joints using bituminous anti-corrosion tape. Nominal diameter of pipe 400mm |
| 030038H | Make external protection to steel pipe joints using bituminous anti-corrosion tape. Nominal diameter of pipe 450 - 525mm |
| 030038I | Make external protection to steel pipe joints using bituminous anti-corrosion tape. Nominal diameter of pipe 600 - 675mm |
| 030038J | Make external protection to steel pipe joints using bituminous anti-corrosion tape. Nominal diameter of pipe 700 - 750mm |
| 030038K | Make external protection to steel pipe joints using bituminous anti-corrosion tape. Nominal diameter of pipe 800 mm |
| 030038L | Make external protection to steel pipe joints using bituminous anti-corrosion tape. Nominal diameter of pipe 900 mm |
| 030038M | Make external protection to steel pipe joints using bituminous anti-corrosion tape. Nominal diameter of pipe 1000 - 1100 mm |
| 030038N | Make external protection to steel pipe joints using bituminous anti-corrosion tape. Nominal diameter of pipe 1200 mm |
| 030038O | Make external protection to steel pipe joints using bituminous anti-corrosion tape. Nominal diameter of pipe 1350 - 1400 mm |
| 030038P | Make external protection to steel pipe joints using bituminous anti-corrosion tape. Nominal diameter of pipe 1600 mm |
| 030038Q | Make external protection to steel pipe joints using bituminous anti-corrosion tape. Nominal diameter of pipe 1800 mm |
| 030038R | Make external protection to steel pipe joints using bituminous anti-corrosion tape. Nominal diameter of pipe 1950 - 2100 mm |
| 030038S | Make external protection to steel pipe joints using bituminous anti-corrosion tape. Nominal diameter of pipe > 2100 mm |
| 030039C | Make external protection to flanges, coupling & adaptors, using petroleum anti-corrosion tape. Nominal diameter of pipe 125 -150mm |
| 030039D | Make external protection to flanges, coupling & adaptors, using petroleum anti-corrosion tape. Nominal diameter of pipe 200mm |
| 030039E | Make external protection to flanges, coupling & adaptors, using petroleum anti-corrosion tape. Nominal diameter of pipe 250mm |
| 030039F | Make external protection to flanges, coupling & adaptors, using petroleum anti-corrosion tape. Nominal diameter of pipe 300 - 350mm |
| 030039G | Make external protection to flanges, coupling & adaptors, using petroleum anti-corrosion tape. Nominal diameter of pipe 400mm |
| 030039H | Make external protection to flanges, coupling & adaptors, using petroleum anti-corrosion tape. Nominal diameter of pipe 450 - 525mm |
| 030039I | Make external protection to flanges, coupling & adaptors, using petroleum anti-corrosion tape. Nominal diameter of pipe 600 - 675mm |
| 030039J | Make external protection to flanges, coupling & adaptors, using petroleum anti-corrosion tape. Nominal diameter of pipe 700 - 750mm |
| 030039K | Make external protection to flanges, coupling & adaptors, using petroleum anti-corrosion tape. Nominal diameter of pipe 800 mm |
| 030039L | Make external protection to flanges, coupling & adaptors, using petroleum anti-corrosion tape. Nominal diameter of pipe 900 mm |
| 030039M | Make external protection to flanges, coupling & adaptors, using petroleum anti-corrosion tape. Nominal diameter of pipe 1000 - 1100 mm |
| 030039N | Make external protection to flanges, coupling & adaptors, using petroleum anti-corrosion tape. Nominal diameter of pipe 1200 mm |
| 030039O | Make external protection to flanges, coupling & adaptors, using petroleum anti-corrosion tape. Nominal diameter of pipe 1350 - 1400 mm |
| 030039P | Make external protection to flanges, coupling & adaptors, using petroleum anti-corrosion tape. Nominal diameter of pipe 1600 mm |
| 030039Q | Make external protection to flanges, coupling & adaptors, using petroleum anti-corrosion tape. Nominal diameter of pipe 1800 mm |
| 030039R | Make external protection to flanges, coupling & adaptors, using petroleum anti-corrosion tape. Nominal diameter of pipe 1950 - 2100 mm |
| 030039S | Make external protection to flanges, coupling & adaptors, using petroleum anti-corrosion tape. Nominal diameter of pipe > 2100 mm |
| 030040C | Repair bitumen sheathing to steel pipes including handling. Nominal diameter of pipe 125 -150mm |
| 030040D | Repair bitumen sheathing to steel pipes including handling. Nominal diameter of pipe 200mm |
| 030040E | Repair bitumen sheathing to steel pipes including handling. Nominal diameter of pipe 250mm |
| 030040F | Repair bitumen sheathing to steel pipes including handling. Nominal diameter of pipe 300 - 350mm |
| 030040G | Repair bitumen sheathing to steel pipes including handling. Nominal diameter of pipe 400mm |
| 030040H | Repair bitumen sheathing to steel pipes including handling. Nominal diameter of pipe 450 - 525mm |
| 030040I | Repair bitumen sheathing to steel pipes including handling. Nominal diameter of pipe 600 - 675mm |
| 030040J | Repair bitumen sheathing to steel pipes including handling. Nominal diameter of pipe 700 - 750mm |
| 030040K | Repair bitumen sheathing to steel pipes including handling. Nominal diameter of pipe 800 mm |
| 030040L | Repair bitumen sheathing to steel pipes including handling. Nominal diameter of pipe 900 mm |
| 030040M | Repair bitumen sheathing to steel pipes including handling. Nominal diameter of pipe 1000 - 1100 mm |
| 030040N | Repair bitumen sheathing to steel pipes including handling. Nominal diameter of pipe 1200 mm |
| 030040O | Repair bitumen sheathing to steel pipes including handling. Nominal diameter of pipe 1350 - 1400 mm |
| 030040P | Repair bitumen sheathing to steel pipes including handling. Nominal diameter of pipe 1600 mm |
| 030040Q | Repair bitumen sheathing to steel pipes including handling. Nominal diameter of pipe 1800 mm |
| 030040R | Repair bitumen sheathing to steel pipes including handling. Nominal diameter of pipe 1950 - 2100 mm |
| 030040S | Repair bitumen sheathing to steel pipes including handling. Nominal diameter of pipe > 2100 mm |
| 030041C | Repair bitumen lining. Nominal diameter of pipe 125 -150mm |
| 030041D | Repair bitumen lining. Nominal diameter of pipe 200mm |
| 030041E | Repair bitumen lining. Nominal diameter of pipe 250mm |
| 030041F | Repair bitumen lining. Nominal diameter of pipe 300 - 350mm |
| 030041G | Repair bitumen lining. Nominal diameter of pipe 400mm |
| 030041H | Repair bitumen lining. Nominal diameter of pipe 450 - 525mm |
| 030041I | Repair bitumen lining. Nominal diameter of pipe 600 - 675mm |
| 030041J | Repair bitumen lining. Nominal diameter of pipe 700 - 750mm |
| 030041K | Repair bitumen lining. Nominal diameter of pipe 800 mm |
| 030041L | Repair bitumen lining. Nominal diameter of pipe 900 mm |
| 030041M | Repair bitumen lining. Nominal diameter of pipe 1000 - 1100 mm |
| 030041N | Repair bitumen lining. Nominal diameter of pipe 1200 mm |
| 030041O | Repair bitumen lining. Nominal diameter of pipe 1350 - 1400 mm |
| 030041P | Repair bitumen lining. Nominal diameter of pipe 1600 mm |
| 030041Q | Repair bitumen lining. Nominal diameter of pipe 1800 mm |
| 030041R | Repair bitumen lining. Nominal diameter of pipe 1950 - 2100 mm |
| 030041S | Repair bitumen lining. Nominal diameter of pipe > 2100 mm |
| 030042I | Repair internal lining to steel pipes with approved primer and 2 coats of approved epoxy paint provided by the Contractor. Nominal diameter of pipe 600 - 675mm |
| 030042J | Repair internal lining to steel pipes with approved primer and 2 coats of approved epoxy paint provided by the Contractor. Nominal diameter of pipe 700 - 750mm |
| 030042K | Repair internal lining to steel pipes with approved primer and 2 coats of approved epoxy paint provided by the Contractor. Nominal diameter of pipe 800 mm |
| 030042L | Repair internal lining to steel pipes with approved primer and 2 coats of approved epoxy paint provided by the Contractor. Nominal diameter of pipe 900 mm |
| 030042M | Repair internal lining to steel pipes with approved primer and 2 coats of approved epoxy paint provided by the Contractor. Nominal diameter of pipe 1000 - 1100 mm |
| 030042N | Repair internal lining to steel pipes with approved primer and 2 coats of approved epoxy paint provided by the Contractor. Nominal diameter of pipe 1200 mm |
| 030042O | Repair internal lining to steel pipes with approved primer and 2 coats of approved epoxy paint provided by the Contractor. Nominal diameter of pipe 1350 - 1400 mm |
| 030042P | Repair internal lining to steel pipes with approved primer and 2 coats of approved epoxy paint provided by the Contractor. Nominal diameter of pipe 1600 mm |
| 030042Q | Repair internal lining to steel pipes with approved primer and 2 coats of approved epoxy paint provided by the Contractor. Nominal diameter of pipe 1800 mm |
| 030042R | Repair internal lining to steel pipes with approved primer and 2 coats of approved epoxy paint provided by the Contractor. Nominal diameter of pipe 1950 - 2100 mm |
| 030042S | Repair internal lining to steel pipes with approved primer and 2 coats of approved epoxy paint provided by the Contractor. Nominal diameter of pipe > 2100 mm |
| 030043B | Provide 1:3 cement mortar and repair cement concrete lining. Nominal diameter of pipe 100mm |
| 030043C | Provide 1:3 cement mortar and repair cement concrete lining. Nominal diameter of pipe 125 -150mm |
| 030043D | Provide 1:3 cement mortar and repair cement concrete lining. Nominal diameter of pipe 200mm |
| 030043E | Provide 1:3 cement mortar and repair cement concrete lining. Nominal diameter of pipe 250mm |
| 030043F | Provide 1:3 cement mortar and repair cement concrete lining. Nominal diameter of pipe 300 - 350mm |
| 030043G | Provide 1:3 cement mortar and repair cement concrete lining. Nominal diameter of pipe 400mm |
| 030043H | Provide 1:3 cement mortar and repair cement concrete lining. Nominal diameter of pipe 450 - 525mm |
| 030043I | Provide 1:3 cement mortar and repair cement concrete lining. Nominal diameter of pipe 600 - 675mm |
| 030043J | Provide 1:3 cement mortar and repair cement concrete lining. Nominal diameter of pipe 700 - 750mm |
| 030043K | Provide 1:3 cement mortar and repair cement concrete lining. Nominal diameter of pipe 800 mm |
| 030044B | Provide 1:3 cement mortar and repair lining at end of ductile iron pipe, area not exceeding 0.01 m2. Nominal diameter of pipe 100mm |
| 030044C | Provide 1:3 cement mortar and repair lining at end of ductile iron pipe, area not exceeding 0.01 m2. Nominal diameter of pipe 125 -150mm |
| 030044D | Provide 1:3 cement mortar and repair lining at end of ductile iron pipe, area not exceeding 0.01 m2. Nominal diameter of pipe 200mm |
| 030044E | Provide 1:3 cement mortar and repair lining at end of ductile iron pipe, area not exceeding 0.01 m2. Nominal diameter of pipe 250mm |
| 030044F | Provide 1:3 cement mortar and repair lining at end of ductile iron pipe, area not exceeding 0.01 m2. Nominal diameter of pipe 300 - 350mm |
| 030044G | Provide 1:3 cement mortar and repair lining at end of ductile iron pipe, area not exceeding 0.01 m2. Nominal diameter of pipe 400mm |
| 030044H | Provide 1:3 cement mortar and repair lining at end of ductile iron pipe, area not exceeding 0.01 m2. Nominal diameter of pipe 450 - 525mm |
| 030044I | Provide 1:3 cement mortar and repair lining at end of ductile iron pipe, area not exceeding 0.01 m2. Nominal diameter of pipe 600 - 675mm |
| 030045B | Provide 1:3 cement mortar and repair lining at end of ductile iron pipe, area exceeding 0.01 m2 but not exceeding 0.1 m2. Nominal diameter of pipe 100mm |
| 030045C | Provide 1:3 cement mortar and repair lining at end of ductile iron pipe, area exceeding 0.01 m2 but not exceeding 0.1 m2. Nominal diameter of pipe 125 -150mm |
| 030045D | Provide 1:3 cement mortar and repair lining at end of ductile iron pipe, area exceeding 0.01 m2 but not exceeding 0.1 m2. Nominal diameter of pipe 200mm |
| 030045E | Provide 1:3 cement mortar and repair lining at end of ductile iron pipe, area exceeding 0.01 m2 but not exceeding 0.1 m2. Nominal diameter of pipe 250mm |
| 030045F | Provide 1:3 cement mortar and repair lining at end of ductile iron pipe, area exceeding 0.01 m2 but not exceeding 0.1 m2. Nominal diameter of pipe 300 - 350mm |
| 030045G | Provide 1:3 cement mortar and repair lining at end of ductile iron pipe, area exceeding 0.01 m2 but not exceeding 0.1 m2. Nominal diameter of pipe 400mm |
| 030045H | Provide 1:3 cement mortar and repair lining at end of ductile iron pipe, area exceeding 0.01 m2 but not exceeding 0.1 m2. Nominal diameter of pipe 450 - 525mm |
| 030045I | Provide 1:3 cement mortar and repair lining at end of ductile iron pipe, area exceeding 0.01 m2 but not exceeding 0.1 m2. Nominal diameter of pipe 600 - 675mm |
| 030046A | Repair packings of sluice valve. Nominal diameter of pipe 80mm & under |
| 030046B | Repair packings of sluice valve. Nominal diameter of pipe 100mm |
| 030046C | Repair packings of sluice valve. Nominal diameter of pipe 125 -150mm |
| 030046D | Repair packings of sluice valve. Nominal diameter of pipe 200mm |
| 030046E | Repair packings of sluice valve. Nominal diameter of pipe 250mm |
| 030046F | Repair packings of sluice valve. Nominal diameter of pipe 300 - 350mm |
| 030046G | Repair packings of sluice valve. Nominal diameter of pipe 400mm |
| 030046H | Repair packings of sluice valve. Nominal diameter of pipe 450 - 525mm |
| 030046I | Repair packings of sluice valve. Nominal diameter of pipe 600 - 675mm |
| 030046J | Repair packings of sluice valve. Nominal diameter of pipe 700 - 750mm |
| 030046K | Repair packings of sluice valve. Nominal diameter of pipe 800 mm |
| 030046L | Repair packings of sluice valve. Nominal diameter of pipe 900 mm |
| 030046M | Repair packings of sluice valve. Nominal diameter of pipe 1000 - 1100 mm |
| 030046N | Repair packings of sluice valve. Nominal diameter of pipe 1200 mm |
| 030047A | Cleaning and sterilization of fresh water pipelines. Nominal diameter of pipe 80mm & under |
| 030047B | Cleaning and sterilization of fresh water pipelines. Nominal diameter of pipe 100mm |
| 030047C | Cleaning and sterilization of fresh water pipelines. Nominal diameter of pipe 125 -150mm |
| 030047D | Cleaning and sterilization of fresh water pipelines. Nominal diameter of pipe 200mm |
| 030047E | Cleaning and sterilization of fresh water pipelines. Nominal diameter of pipe 250mm |
| 030047F | Cleaning and sterilization of fresh water pipelines. Nominal diameter of pipe 300 - 350mm |
| 030047G | Cleaning and sterilization of fresh water pipelines. Nominal diameter of pipe 400mm |
| 030047H | Cleaning and sterilization of fresh water pipelines. Nominal diameter of pipe 450 - 525mm |
| 030047I | Cleaning and sterilization of fresh water pipelines. Nominal diameter of pipe 600 - 675mm |
| 030047J | Cleaning and sterilization of fresh water pipelines. Nominal diameter of pipe 700 - 750mm |
| 030047K | Cleaning and sterilization of fresh water pipelines. Nominal diameter of pipe 800 mm |
| 030047L | Cleaning and sterilization of fresh water pipelines. Nominal diameter of pipe 900 mm |
| 030047M | Cleaning and sterilization of fresh water pipelines. Nominal diameter of pipe 1000 - 1100mm |
| 030047N | Cleaning and sterilization of fresh water pipelines. Nominal diameter of pipe 1200 mm |
| 030047O | Cleaning and sterilization of fresh water pipelines. Nominal diameter of pipe 1350 - 1400mm |
| 030047P | Cleaning and sterilization of fresh water pipelines. Nominal diameter of pipe 1600 mm |
| 030047Q | Cleaning and sterilization of fresh water pipelines. Nominal diameter of pipe 1800 mm |
| 030047R | Cleaning and sterilization of fresh water pipelines. Nominal diameter of pipe 1950 - 2100mm |
| 030047S | Cleaning and sterilization of fresh water pipelines. Nominal diameter of pipe > 2100 mm |
| 030048A | Cleaning and flushing of water pipelines. Nominal diameter of pipe 80mm & under |
| 030048B | Cleaning and flushing of water pipelines. Nominal diameter of pipe 100mm |
| 030048C | Cleaning and flushing of water pipelines. Nominal diameter of pipe 125 -150mm |
| 030048D | Cleaning and flushing of water pipelines. Nominal diameter of pipe 200mm |
| 030048E | Cleaning and flushing of water pipelines. Nominal diameter of pipe 250mm |
| 030048F | Cleaning and flushing of water pipelines. Nominal diameter of pipe 300 - 350mm |
| 030048G | Cleaning and flushing of water pipelines. Nominal diameter of pipe 400mm |
| 030048H | Cleaning and flushing of water pipelines. Nominal diameter of pipe 450 - 525mm |
| 030048I | Cleaning and flushing of water pipelines. Nominal diameter of pipe 600 - 675mm |
| 030048J | Cleaning and flushing of water pipelines. Nominal diameter of pipe 700 - 750mm |
| 030048K | Cleaning and flushing of water pipelines. Nominal diameter of pipe 800 mm |
| 030048L | Cleaning and flushing of water pipelines. Nominal diameter of pipe 900 mm |
| 030048M | Cleaning and flushing of water pipelines. Nominal diameter of pipe 1000 - 1100mm |
| 030048N | Cleaning and flushing of water pipelines. Nominal diameter of pipe 1200 mm |
| 030048O | Cleaning and flushing of water pipelines. Nominal diameter of pipe 1350 - 1400mm |
| 030048P | Cleaning and flushing of water pipelines. Nominal diameter of pipe 1600 mm |
| 030048Q | Cleaning and flushing of water pipelines. Nominal diameter of pipe 1800 mm |
| 030048R | Cleaning and flushing of water pipelines. Nominal diameter of pipe 1950 - 2100mm |
| 030048S | Cleaning and flushing of water pipelines. Nominal diameter of pipe > 2100 mm |
| 030049A | Swabbing pipelines. Nominal diameter of pipe 80mm & under |
| 030049B | Swabbing pipelines. Nominal diameter of pipe 100mm |
| 030049C | Swabbing pipelines. Nominal diameter of pipe 125 -150mm |
| 030049D | Swabbing pipelines. Nominal diameter of pipe 200mm |
| 030049E | Swabbing pipelines. Nominal diameter of pipe 250mm |
| 030049F | Swabbing pipelines. Nominal diameter of pipe 300 - 350mm |
| 030049G | Swabbing pipelines. Nominal diameter of pipe 400mm |
| 030049H | Swabbing pipelines. Nominal diameter of pipe 450 - 525mm |
| 030049I | Swabbing pipelines. Nominal diameter of pipe 600 - 675mm |
| 030050A | Hydrostatic pressure testing of pipelines. Nominal diameter of pipe 80mm & under |
| 030050B | Hydrostatic pressure testing of pipelines. Nominal diameter of pipe 100mm |
| 030050C | Hydrostatic pressure testing of pipelines. Nominal diameter of pipe 125 -150mm |
| 030050D | Hydrostatic pressure testing of pipelines. Nominal diameter of pipe 200mm |
| 030050E | Hydrostatic pressure testing of pipelines. Nominal diameter of pipe 250mm |
| 030050F | Hydrostatic pressure testing of pipelines. Nominal diameter of pipe 300 - 350mm |
| 030050G | Hydrostatic pressure testing of pipelines. Nominal diameter of pipe 400mm |
| 030050H | Hydrostatic pressure testing of pipelines. Nominal diameter of pipe 450 - 525mm |
| 030050I | Hydrostatic pressure testing of pipelines. Nominal diameter of pipe 600 - 675mm |
| 030050J | Hydrostatic pressure testing of pipelines. Nominal diameter of pipe 700 - 750mm |
| 030050K | Hydrostatic pressure testing of pipelines. Nominal diameter of pipe 800 mm |
| 030050L | Hydrostatic pressure testing of pipelines. Nominal diameter of pipe 900 mm |
| 030050M | Hydrostatic pressure testing of pipelines. Nominal diameter of pipe 1000 - 1100mm |
| 030050N | Hydrostatic pressure testing of pipelines. Nominal diameter of pipe 1200 mm |
| 030050O | Hydrostatic pressure testing of pipelines. Nominal diameter of pipe 1350 - 1400mm |
| 030050P | Hydrostatic pressure testing of pipelines. Nominal diameter of pipe 1600 mm |
| 030050Q | Hydrostatic pressure testing of pipelines. Nominal diameter of pipe 1800 mm |
| 030050R | Hydrostatic pressure testing of pipelines. Nominal diameter of pipe 1950 - 2100mm |
| 030050S | Hydrostatic pressure testing of pipelines. Nominal diameter of pipe > 2100 mm |
| 030051 | Supply detectable warning tapes for non-metallic water mains as shown in Drawing No. WSD 1.37. |
| 030052 | Supply and lay detectable warning tapes for non-metallic water mains as shown in Drawing No. WSD 1.37. |
| 030053 | Actuator for valve exercising. |
| 030053aA | Valve exercising. Nominal diameter of pipe 80mm & under |
| 030053aB | Valve exercising. Nominal diameter of pipe 100mm |
| 030053aC | Valve exercising. Nominal diameter of pipe 125 -150mm |
| 030053aD | Valve exercising. Nominal diameter of pipe 200mm |
| 030053aE | Valve exercising. Nominal diameter of pipe 250mm |
| 030053aF | Valve exercising. Nominal diameter of pipe 300 - 350mm |
| 030053aG | Valve exercising. Nominal diameter of pipe 400mm |
| 030053aH | Valve exercising. Nominal diameter of pipe 450 - 525mm |
| 030053aI | Valve exercising. Nominal diameter of pipe 600 - 675mm |
| 030053aJ | Valve exercising. Nominal diameter of pipe 700 - 750mm |
| 030053aK | Valve exercising. Nominal diameter of pipe 800 mm |
| 030053aL | Valve exercising. Nominal diameter of pipe 900 mm |
| 030053aM | Valve exercising. Nominal diameter of pipe 1000 - 1100mm |
| 030053aN | Valve exercising. Nominal diameter of pipe 1200 mm |
| 030053aO | Valve exercising. Nominal diameter of pipe 1350 - 1400mm |
| 030053aP | Valve exercising. Nominal diameter of pipe 1600 mm |
| 030053aQ | Valve exercising. Nominal diameter of pipe 1800 mm |
| 030053aR | Valve exercising. Nominal diameter of pipe 1950 - 2100mm |
| 030053aS | Valve exercising. Nominal diameter of pipe > 2100 mm |
| 030053bF | Extra over Item No. 030/053a for valve exercising using actuator. Nominal diameter of pipe 300 - 350mm |
| 030053bG | Extra over Item No. 030/053a for valve exercising using actuator. Nominal diameter of pipe 400mm |
| 030053bH | Extra over Item No. 030/053a for valve exercising using actuator. Nominal diameter of pipe 450 - 525mm |
| 030053bI | Extra over Item No. 030/053a for valve exercising using actuator. Nominal diameter of pipe 600 - 675mm |
| 030053bJ | Extra over Item No. 030/053a for valve exercising using actuator. Nominal diameter of pipe 700 - 750mm |
| 030053bK | Extra over Item No. 030/053a for valve exercising using actuator. Nominal diameter of pipe 800 mm |
| 030053bL | Extra over Item No. 030/053a for valve exercising using actuator. Nominal diameter of pipe 900 mm |
| 030053bM | Extra over Item No. 030/053a for valve exercising using actuator. Nominal diameter of pipe 1000 - 1100mm |
| 030053bN | Extra over Item No. 030/053a for valve exercising using actuator. Nominal diameter of pipe 1200 mm |
| 030053bO | Extra over Item No. 030/053a for valve exercising using actuator. Nominal diameter of pipe 1350 - 1400mm |
| 030053bP | Extra over Item No. 030/053a for valve exercising using actuator. Nominal diameter of pipe 1600 mm |
| 030053bQ | Extra over Item No. 030/053a for valve exercising using actuator. Nominal diameter of pipe 1800 mm |
| 030053bR | Extra over Item No. 030/053a for valve exercising using actuator. Nominal diameter of pipe 1950 - 2100mm |
| 030053bS | Extra over Item No. 030/053a for valve exercising using actuator. Nominal diameter of pipe > 2100 mm |
| 030054A | Valve closing operation. Nominal diameter of pipe 80mm & under |
| 030054B | Valve closing operation. Nominal diameter of pipe 100mm |
| 030054C | Valve closing operation. Nominal diameter of pipe 125 -150mm |
| 030054D | Valve closing operation. Nominal diameter of pipe 200mm |
| 030054E | Valve closing operation. Nominal diameter of pipe 250mm |
| 030054F | Valve closing operation. Nominal diameter of pipe 300 - 350mm |
| 030054G | Valve closing operation. Nominal diameter of pipe 400mm |
| 030054H | Valve closing operation. Nominal diameter of pipe 450 - 525mm |
| 030054I | Valve closing operation. Nominal diameter of pipe 600 - 675mm |
| 030054J | Valve closing operation. Nominal diameter of pipe 700 - 750mm |
| 030054K | Valve closing operation. Nominal diameter of pipe 800 mm |
| 030054L | Valve closing operation. Nominal diameter of pipe 900 mm |
| 030054M | Valve closing operation. Nominal diameter of pipe 1000 - 1100mm |
| 030054N | Valve closing operation. Nominal diameter of pipe 1200 mm |
| 030054O | Valve closing operation. Nominal diameter of pipe 1350 - 1400mm |
| 030054P | Valve closing operation. Nominal diameter of pipe 1600 mm |
| 030054Q | Valve closing operation. Nominal diameter of pipe 1800 mm |
| 030054R | Valve closing operation. Nominal diameter of pipe 1950 - 2100mm |
| 030054S | Valve closing operation. Nominal diameter of pipe > 2100 mm |
| 030055A | Valve opening operation. Nominal diameter of pipe 80mm & under |
| 030055B | Valve opening operation. Nominal diameter of pipe 100mm |
| 030055C | Valve opening operation. Nominal diameter of pipe 125 -150mm |
| 030055D | Valve opening operation. Nominal diameter of pipe 200mm |
| 030055E | Valve opening operation. Nominal diameter of pipe 250mm |
| 030055F | Valve opening operation. Nominal diameter of pipe 300 - 350mm |
| 030055G | Valve opening operation. Nominal diameter of pipe 400mm |
| 030055H | Valve opening operation. Nominal diameter of pipe 450 - 525mm |
| 030055I | Valve opening operation. Nominal diameter of pipe 600 - 675mm |
| 030055J | Valve opening operation. Nominal diameter of pipe 700 - 750mm |
| 030055K | Valve opening operation. Nominal diameter of pipe 800 mm |
| 030055L | Valve opening operation. Nominal diameter of pipe 900 mm |
| 030055M | Valve opening operation. Nominal diameter of pipe 1000 - 1100mm |
| 030055N | Valve opening operation. Nominal diameter of pipe 1200 mm |
| 030055O | Valve opening operation. Nominal diameter of pipe 1350 - 1400mm |
| 030055P | Valve opening operation. Nominal diameter of pipe 1600 mm |
| 030055Q | Valve opening operation. Nominal diameter of pipe 1800 mm |
| 030055R | Valve opening operation. Nominal diameter of pipe 1950 - 2100mm |
| 030055S | Valve opening operation. Nominal diameter of pipe > 2100 mm |
| 030056A | Vacuum cleaning of valve chamber. Nominal diameter of pipe 80mm & under |
| 030056B | Vacuum cleaning of valve chamber. Nominal diameter of pipe 100mm |
| 030056C | Vacuum cleaning of valve chamber. Nominal diameter of pipe 125 -150mm |
| 030056D | Vacuum cleaning of valve chamber. Nominal diameter of pipe 200mm |
| 030056E | Vacuum cleaning of valve chamber. Nominal diameter of pipe 250mm |
| 030056F | Vacuum cleaning of valve chamber. Nominal diameter of pipe 300 - 350mm |
| 030056G | Vacuum cleaning of valve chamber. Nominal diameter of pipe 400mm |
| 030056H | Vacuum cleaning of valve chamber. Nominal diameter of pipe 450 - 525mm |
| 030056I | Vacuum cleaning of valve chamber. Nominal diameter of pipe 600 - 675mm |
| 030056J | Vacuum cleaning of valve chamber. Nominal diameter of pipe 700 - 750mm |
| 030056K | Vacuum cleaning of valve chamber. Nominal diameter of pipe 800 mm |
| 030056L | Vacuum cleaning of valve chamber. Nominal diameter of pipe 900 mm |
| 030056M | Vacuum cleaning of valve chamber. Nominal diameter of pipe 1000 - 1100mm |
| 030056N | Vacuum cleaning of valve chamber. Nominal diameter of pipe 1200 mm |
| 030056O | Vacuum cleaning of valve chamber. Nominal diameter of pipe 1350 - 1400mm |
| 030056P | Vacuum cleaning of valve chamber. Nominal diameter of pipe 1600 mm |
| 030056Q | Vacuum cleaning of valve chamber. Nominal diameter of pipe 1800 mm |
| 030056R | Vacuum cleaning of valve chamber. Nominal diameter of pipe 1950 - 2100mm |
| 030056S | Vacuum cleaning of valve chamber. Nominal diameter of pipe > 2100 mm |
| 030057C | Additional random testing on electrofusion joints. Destructive testing on electrifusion joints. Nominal diameter of pipe > 25 mm |
| 030057D | Additional random testing on electrofusion joints. Destructive testing on electrifusion joints. Nominal diameter of pipe > 40 mm |
| 030057E | Additional random testing on electrofusion joints. Destructive testing on electrifusion joints. Nominal diameter of pipe > 50 mm |
| 030057F | Additional random testing on electrofusion joints. Destructive testing on electrifusion joints. Nominal diameter of pipe > 80 mm |
| 030057G | Additional random testing on electrofusion joints. Destructive testing on electrifusion joints. Nominal diameter of pipe > 100 mm |
| 030057H | Additional random testing on electrofusion joints. Destructive testing on electrifusion joints. Nominal diameter of pipe > 150 mm |
| 030057I | Additional random testing on electrofusion joints. Destructive testing on electrifusion joints. Nominal diameter of pipe > 200 mm |
| 030057J | Additional random testing on electrofusion joints. Destructive testing on electrifusion joints. Nominal diameter of pipe > 250 mm |
| 030058A | Sealing disused pipes. Nominal diameter of pipe 80mm & under |
| 030058B | Sealing disused pipes. Nominal diameter of pipe 100mm |
| 030058C | Sealing disused pipes. Nominal diameter of pipe 125 -150mm |
| 030058D | Sealing disused pipes. Nominal diameter of pipe 200mm |
| 030058E | Sealing disused pipes. Nominal diameter of pipe 250mm |
| 030058F | Sealing disused pipes. Nominal diameter of pipe 300 - 350mm |
| 030058G | Sealing disused pipes. Nominal diameter of pipe 400mm |
| 030058H | Sealing disused pipes. Nominal diameter of pipe 450 - 525mm |
| 030058I | Sealing disused pipes. Nominal diameter of pipe 600 - 675mm |
| 030058J | Sealing disused pipes. Nominal diameter of pipe 700 - 750mm |
| 030058K | Sealing disused pipes. Nominal diameter of pipe 800 mm |
| 030058L | Sealing disused pipes. Nominal diameter of pipe 900 mm |
| 030058M | Sealing disused pipes. Nominal diameter of pipe 1000 - 1100mm |
| 030058N | Sealing disused pipes. Nominal diameter of pipe 1200 mm |
| 030058O | Sealing disused pipes. Nominal diameter of pipe 1350 - 1400mm |
| 030058P | Sealing disused pipes. Nominal diameter of pipe 1600 mm |
| 030058Q | Sealing disused pipes. Nominal diameter of pipe 1800 mm |
| 030058R | Sealing disused pipes. Nominal diameter of pipe 1950 - 2100mm |
| 030058S | Sealing disused pipes. Nominal diameter of pipe > 2100 mm |
| 030059F | Filling disused pipes with grout. Nominal diameter of pipe 300 - 350mm |
| 030059G | Filling disused pipes with grout. Nominal diameter of pipe 400mm |
| 030059H | Filling disused pipes with grout. Nominal diameter of pipe 450 - 525mm |
| 030059I | Filling disused pipes with grout. Nominal diameter of pipe 600 - 675mm |
| 030059J | Filling disused pipes with grout. Nominal diameter of pipe 700 - 750mm |
| 030059K | Filling disused pipes with grout. Nominal diameter of pipe 800 mm |
| 030059L | Filling disused pipes with grout. Nominal diameter of pipe 900 mm |
| 030059M | Filling disused pipes with grout. Nominal diameter of pipe 1000 - 1100mm |
| 030059N | Filling disused pipes with grout. Nominal diameter of pipe 1200 mm |
| 030059O | Filling disused pipes with grout. Nominal diameter of pipe 1350 - 1400mm |
| 030059P | Filling disused pipes with grout. Nominal diameter of pipe 1600 mm |
| 030059Q | Filling disused pipes with grout. Nominal diameter of pipe 1800 mm |
| 030059R | Filling disused pipes with grout. Nominal diameter of pipe 1950 - 2100mm |
| 030059S | Filling disused pipes with grout. Nominal diameter of pipe > 2100 mm |
| 030060F | Filling disused pipes with foam concrete. Nominal diameter of pipe 300 - 350mm |
| 030060G | Filling disused pipes with foam concrete. Nominal diameter of pipe 400mm |
| 030060H | Filling disused pipes with foam concrete. Nominal diameter of pipe 450 - 525mm |
| 030060I | Filling disused pipes with foam concrete. Nominal diameter of pipe 600 - 675mm |
| 030060J | Filling disused pipes with foam concrete. Nominal diameter of pipe 700 - 750mm |
| 030060K | Filling disused pipes with foam concrete. Nominal diameter of pipe 800 mm |
| 030060L | Filling disused pipes with foam concrete. Nominal diameter of pipe 900 mm |
| 030060M | Filling disused pipes with foam concrete. Nominal diameter of pipe 1000 - 1100mm |
| 030060N | Filling disused pipes with foam concrete. Nominal diameter of pipe 1200 mm |
| 030060O | Filling disused pipes with foam concrete. Nominal diameter of pipe 1350 - 1400mm |
| 030060P | Filling disused pipes with foam concrete. Nominal diameter of pipe 1600 mm |
| 030060Q | Filling disused pipes with foam concrete. Nominal diameter of pipe 1800 mm |
| 030060R | Filling disused pipes with foam concrete. Nominal diameter of pipe 1950 - 2100mm |
| 030060S | Filling disused pipes with foam concrete. Nominal diameter of pipe > 2100 mm |
| 030061 | Provision of set of SACP system with Particular Design as specified in PS Clause 22.31 for protected pipe length not exceeding 100 m |
| 030062 | Extra over item no. 030/061 for additional protected pipe length |
| 030063 | Supply of pre-package Magnesium Anode exceeding 0.5m but not exceeding 1.0m long with chemical backfill and minimum 5m long cable as specified in PS Clause 22.32 |
| 030064 | Supply of pre-package Magnesium Anode exceeding 1.0m but not exceeding 1.5m long with chemical backfill and minimum 5m long cable as specified in PS Clause 22.32 |
| 030065 | Supply of Fibre-Reinforced Polymer (FRP) Mesh Grating (1m long x 1m width x 25mm thick) with WSD Logo as specified in PS Clause 22.32 |
| 030066 | Installation of pre-package Magnesium Anode as specified in PS Clause 22.32 |
| 030067 | Installation of Fibre-Reinforced Polymer (FRP) Mesh Grating as specified in PS Clause 22.32 |
| 030068 | Supply and installation of Control/Test Station with monitoring cable as specified in PS Clause 22.32 |
| 030069 | Maintenance and checking of each Control/Test Station of SACP system as specified in PS Clause 22.33 |
| 031001A | Temporary repair of pipes rehabilitated with Tyfo Fibrwrap System excluding works related to installation of double end rings as specified in PS Clause 22.18 and paragraph 2.2 in Appendix 22.38 to PS. Nominal diameter of pipe 1200 mm |
| 031001B | Temporary repair of pipes rehabilitated with Tyfo Fibrwrap System excluding works related to installation of double end rings as specified in PS Clause 22.18 and paragraph 2.2 in Appendix 22.38 to PS. Nominal diameter of pipe 1350 - 1400 mm |
| 031001C | Temporary repair of pipes rehabilitated with Tyfo Fibrwrap System excluding works related to installation of double end rings as specified in PS Clause 22.18 and paragraph 2.2 in Appendix 22.38 to PS. Nominal diameter of pipe 1600 mm |
| 031002A | Permanent repair of pipes rehabilitated with Tyfo Fibrwrap System excluding works related to installation of double end rings as specified in PS Clause 22.18 and paragraph 2.3 in Appendix 22.38 to PS. Nominal diameter of pipe 1200 mm |
| 031002B | Permanent repair of pipes rehabilitated with Tyfo Fibrwrap System excluding works related to installation of double end rings as specified in PS Clause 22.18 and paragraph 2.3 in Appendix 22.38 to PS. Nominal diameter of pipe 1350 - 1400 mm |
| 031002C | Permanent repair of pipes rehabilitated with Tyfo Fibrwrap System excluding works related to installation of double end rings as specified in PS Clause 22.18 and paragraph 2.3 in Appendix 22.38 to PS. Nominal diameter of pipe 1600 mm |
| 031003A | Set of double end rings including rubber gaskets for temporary repair and permanent repair of pipes rehabilitated with Tyfo Fibrwrap System as specified in PS Clause 22.18, paragraph 2 in Appendix 22.38 to PS and Annex 22.38A2. Nominal diameter of pipe 1200 mm |
| 031003B | Set of double end rings including rubber gaskets for temporary repair and permanent repair of pipes rehabilitated with Tyfo Fibrwrap System as specified in PS Clause 22.18, paragraph 2 in Appendix 22.38 to PS and Annex 22.38A2. Nominal diameter of pipe 1350 - 1400 mm |
| 031003C | Set of double end rings including rubber gaskets for temporary repair and permanent repair of pipes rehabilitated with Tyfo Fibrwrap System as specified in PS Clause 22.18, paragraph 2 in Appendix 22.38 to PS and Annex 22.38A2. Nominal diameter of pipe 1600 mm |
| 031004A | Maintenance of pipes rehabilitated with Tyfo Fibrwrap System after making welded tee connection as specified in PS Clause 22.18 and paragraph 2.3 in Appendix 22.38 to PS. Nominal diameter of pipe 1200 mm |
| 031004B | Maintenance of pipes rehabilitated with Tyfo Fibrwrap System after making welded tee connection as specified in PS Clause 22.18 and paragraph 2.3 in Appendix 22.38 to PS. Nominal diameter of pipe 1350 - 1400 mm |
| 031004C | Maintenance of pipes rehabilitated with Tyfo Fibrwrap System after making welded tee connection as specified in PS Clause 22.18 and paragraph 2.3 in Appendix 22.38 to PS. Nominal diameter of pipe 1600 mm |
| 031005A | Temporary work pits for rehabilitation of existing water mains. Nominal diameter of the pipe: DN125 to below DN300 |
| 031005B | Temporary work pits for rehabilitation of existing water mains. Nominal diameter of the pipe: DN300 to below DN600 |
| 031005C | Temporary work pits for rehabilitation of existing water mains. Nominal diameter of the pipe: DN600 to below DN1200 |
| 031005D | Temporary work pits for rehabilitation of existing water mains. Nominal diameter of the pipe: DN1200 to DN2500 or above |
| 031006A | Fully Structural Rehabilitation of existing water mains. Nominal diameter of the pipe: DN125 to below DN300 |
| 031006B | Fully Structural Rehabilitation of existing water mains. Nominal diameter of the pipe: DN300 to below DN600 |
| 031006C | Fully Structural Rehabilitation of existing water mains. Nominal diameter of the pipe: DN600 to below DN900 |
| 031006D | Fully Structural Rehabilitation of existing water mains. Nominal diameter of the pipe: DN900 to below DN1200 |
| 031006E | Fully Structural Rehabilitation of existing water mains. Nominal diameter of the pipe: DN1200 to below DN1800 |
| 031006F | Fully Structural Rehabilitation of existing water mains. Nominal diameter of the pipe: DN1800 to below DN2500 |
| 031006G | Fully Structural Rehabilitation of existing water mains. Nominal diameter of the pipe: DN2500 or above |
| 031007A | Semi-structural rehabilitation of existing water mains . Nominal diameter of the pipe: DN125 to below DN300 |
| 031007B | Semi-structural rehabilitation of existing water mains . Nominal diameter of the pipe: DN300 to below DN600 |
| 031007C | Semi-structural rehabilitation of existing water mains . Nominal diameter of the pipe: DN600 to below DN900 |
| 031007D | Semi-structural rehabilitation of existing water mains . Nominal diameter of the pipe: DN900 to below DN1200 |
| 031007E | Semi-structural rehabilitation of existing water mains. Nominal diameter of the pipe: DN1200 to below DN1800 |
| 031007F | Semi-structural rehabilitation of existing water mains . Nominal diameter of the pipe: DN1800 to below DN2500 |
| 031007G | Semi-structural rehabilitation of existing water mains. Nominal diameter of the pipe: DN2500 or above |
| 032001 | Rehabilitation of glass fibre reinforced plastic pipes with hand applied fibre reinforced plastic linings of Tyfo Fibrwrap System or approved products having equivalent functions and performance as specified in PS Clause 22.27. |
| 032002 | Rehabilitation of steel pipes with hand applied fibre reinforced plastic linings of Tyfo Fibrwrap System or approved products having equivalent functions and performance as specified in PS Clause 22.27. |
| 032003 | Rehabilitation of water retaining structures with hand applied fibre reinforced plastic linings having functions and performance as specified in PS Clause 23.08 |
| 040001A | Extra over Item Nos. 020/001, 020/002 and 020/003 for sleeving steel pipes as detailed in Drawing No. SK 3380/8. Nominal diameter of the inner pipe to be measured: 150 mm |
| 040001B | Extra over Item Nos. 020/001, 020/002 and 020/003 for sleeving steel pipes as detailed in Drawing No. SK 3380/8. Nominal diameter of the inner pipe to be measured: 200 mm |
| 040001C | Extra over Item Nos. 020/001, 020/002 and 020/003 for sleeving steel pipes as detailed in Drawing No. SK 3380/8. Nominal diameter of the inner pipe to be measured: 250 mm |
| 040001D | Extra over Item Nos. 020/001, 020/002 and 020/003 for sleeving steel pipes as detailed in Drawing No. SK 3380/8. Nominal diameter of the inner pipe to be measured: 300 mm |
| 040001E | Extra over Item Nos. 020/001, 020/002 and 020/003 for sleeving steel pipes as detailed in Drawing No. SK 3380/8. Nominal diameter of the inner pipe to be measured: 400 mm |
| 040001F | Extra over Item Nos. 020/001, 020/002 and 020/003 for sleeving steel pipes as detailed in Drawing No. SK 3380/8. Nominal diameter of the inner pipe to be measured: 450 mm |
| 040002 | Cut steel pipe longitudinally into two halves. |
| 040003A | Extra over Item Nos. 020/001, 020/002 and 020/003 for laying split steel sleeve pipe halves as detailed in Drawing No. SK 3380/8 to enclose a service pipe including positioning, sealing sleeve ends with wooden stoppers, and ready for welding. Nominal diameter of sleeve pipe: 300 mm |
| 040003B | Extra over Item Nos. 020/001, 020/002 and 020/003 for laying split steel sleeve pipe halves as detailed in Drawing No. SK 3380/8 to enclose a service pipe including positioning, sealing sleeve ends with wooden stoppers, and ready for welding. Nominal diameter of sleeve pipe: 400 mm |
| 040003C | Extra over Item Nos. 020/001, 020/002 and 020/003 for laying split steel sleeve pipe halves as detailed in Drawing No. SK 3380/8 to enclose a service pipe including positioning, sealing sleeve ends with wooden stoppers, and ready for welding. Nominal diameter of sleeve pipe: 450 mm |
| 040003D | Extra over Item Nos. 020/001, 020/002 and 020/003 for laying split steel sleeve pipe halves as detailed in Drawing No. SK 3380/8 to enclose a service pipe including positioning, sealing sleeve ends with wooden stoppers, and ready for welding. Nominal diameter of sleeve pipe: 500 mm |
| 040003E | Extra over Item Nos. 020/001, 020/002 and 020/003 for laying split steel sleeve pipe halves as detailed in Drawing No. SK 3380/8 to enclose a service pipe including positioning, sealing sleeve ends with wooden stoppers, and ready for welding. Nominal diameter of sleeve pipe: 550 mm |
| 040003F | Extra over Item Nos. 020/001, 020/002 and 020/003 for laying split steel sleeve pipe halves as detailed in Drawing No. SK 3380/8 to enclose a service pipe including positioning, sealing sleeve ends with wooden stoppers, and ready for welding. Nominal diameter of sleeve pipe: 600 mm |
| 040003G | Extra over Item Nos. 020/001, 020/002 and 020/003 for laying split steel sleeve pipe halves as detailed in Drawing No. SK 3380/8 to enclose a service pipe including positioning, sealing sleeve ends with wooden stoppers, and ready for welding. Nominal diameter of sleeve pipe: 700 mm |
| 040003H | Extra over Item Nos. 020/001, 020/002 and 020/003 for laying split steel sleeve pipe halves as detailed in Drawing No. SK 3380/8 to enclose a service pipe including positioning, sealing sleeve ends with wooden stoppers, and ready for welding. Nominal diameter of sleeve pipe: 750 mm |
| 040003I | Extra over Item Nos. 020/001, 020/002 and 020/003 for laying split steel sleeve pipe halves as detailed in Drawing No. SK 3380/8 to enclose a service pipe including positioning, sealing sleeve ends with wooden stoppers, and ready for welding. Nominal diameter of sleeve pipe: 800 mm |
| 040004A | Make electrically welded butt joints to full thickness of sleeve pipe. Nominal diameter of sleeve pipe: 300 mm |
| 040004B | Make electrically welded butt joints to full thickness of sleeve pipe. Nominal diameter of sleeve pipe: 400 mm |
| 040004C | Make electrically welded butt joints to full thickness of sleeve pipe. Nominal diameter of sleeve pipe: 450 mm |
| 040004D | Make electrically welded butt joints to full thickness of sleeve pipe. Nominal diameter of sleeve pipe: 500 mm |
| 040004E | Make electrically welded butt joints to full thickness of sleeve pipe. Nominal diameter of sleeve pipe: 550 mm |
| 040004F | Make electrically welded butt joints to full thickness of sleeve pipe. Nominal diameter of sleeve pipe: 600 mm |
| 040004G | Make electrically welded butt joints to full thickness of sleeve pipe. Nominal diameter of sleeve pipe: 700 mm |
| 040004H | Make electrically welded butt joints to full thickness of sleeve pipe. Nominal diameter of sleeve pipe: 750 mm |
| 040004I | Make electrically welded butt joints to full thickness of sleeve pipe. Nominal diameter of sleeve pipe: 800 mm |
| 040005a | Jacking of steel sleeve pipes of diameter not less than 2000mm, depth to invert exceeding S m but not exceeding T m. S=1.5 T=2.5 |
| 040005b | Jacking of steel sleeve pipes of diameter not less than 2000mm, depth to invert exceeding S m but not exceeding T m. S=2.5 T=3.5 |
| 040005c | Jacking of steel sleeve pipes of diameter not less than 2000mm, depth to invert exceeding S m but not exceeding T m. S=3.5 T=4.5 |
| 040005d | Jacking of steel sleeve pipes of diameter not less than 2000mm, depth to invert exceeding S m but not exceeding T m. S=4.5 T=5.5 |
| 040005e | Jacking of steel sleeve pipes of diameter not less than 2000mm, depth to invert exceeding S m but not exceeding T m. S=5.5 T=6.5 |
| 040005f | Jacking of steel sleeve pipes of diameter not less than 2000mm, depth to invert exceeding S m but not exceeding T m. S=6.5 T=7.5 |
| 040006 | Lay only epoxy coated steel pipes of diameter not less than 1600mm inside sleeve pipes installed by pipe jacking. |
| 041001 | Works for maintenance and repair of asbestos cement water mains of any size and for a total length not exceeding 4m, involving cutting and disposal and to be carried out by a registered asbestos contractor in accordance with Section D of Appendix 22.24 to the Particular Specification. |
| 041002 | Works for maintenance and repair of asbestos cement water mains of any size and for a total length not exceeding 4m, involving disconnecting, removal and disposal but not involving any breaking or cutting and to be carried out in accordance with Section F of Appendix 22.24 to the Particular Specification. |
| 041003 | Works for maintenance and repair of asbestos cement water mains of any size and for a total length not exceeding 4 m, involving cutting and disposal and to be carried out by the civil works contractor in accordance with the minimum requirements for works stated in Section G of Appendix 22.24 to the Particular Specification. |
| 041004 | Extra over Item No. 041/003 for works to be carried out by a registered asbestos contractor in accordance with the minimum requirements for works stated in Section G of Appendix 22.24 to the Particular Specification. |
| 041005 | Extra over for works for maintenance and repair of asbestos cement water mains of any size for each additional metre or part thereof in excess of 4m, to be carried out in accordance with Section D of Appendix 22.24 to the Particular Specification. |
| 041006 | Extra over for works for maintenance and repair of asbestos cement water mains of any size for each additional metre or part thereof in excess of 4m, to be carried out in accordance with Section F of Appendix 22.24 to the Particular Specification. |
| 041007 | Extra over for works for maintenance and repair of asbestos cement water mains of any size for each additional metre or part thereof in excess of 4m, to be carried out in accordance with Section G of Appendix 22.24 to the Particular Specification. |
| 041008 | Extra over Item Nos. 041/001 and 041/005 for removal of asbestos cement water mains of any size, encased in concrete and to be carried out by a registered asbestos contractor and supervised by a registered asbestos consultant in accordance with Section E of Appendix 22.24 to the Particular Specification. |
| 041009 | Supply personal protective equipment and decontamination facilities for temporary use by the Engineer for a period of 8 hours. |
| 041010 | Works for maintenance and repair of rehabilitated asbestos cement water mains of any size and for a total length not exceeding 4m, involving cutting and disposal and to be carried out by a registered asbestos contractor in accordance with Particular Specification Clause 22.18. |
| 041011 | Extra over for works for maintenance and repair of rehabilitated asbestos cement water mains of any size for each additional metre or part thereof in excess of 4m, to be carried out in accordance with Particular Specification Clause 22.18. |
| 042001 | Hot tapping to provide an opening of nominal size X mm not exceeding 100mm on existing pressurised water main. X = 50 |
| 042002 | Hot tapping to provide an opening of nominal size X mm not exceeding 100mm on existing pressurised water main. X = 100 |
| 042003 | Hot tapping to provide an opening of nominal size X mm exceeding 100mm by using electricity or hydraulic driven machine on existing pressurised water main:- X=150 |
| 042004 | Hot tapping to provide an opening of nominal size X mm exceeding 100mm by using electricity or hydraulic driven machine on existing pressurised water main:- X=200 |
| 042005 | Hot tapping to provide an opening of nominal size X mm exceeding 100mm by using electricity or hydraulic driven machine on existing pressurised water main:- X=250 |
| 042006 | Hot tapping to provide an opening of nominal size X mm exceeding 100mm by using electricity or hydraulic driven machine on existing pressurised water main:- X=300 |
| 042007 | Hot tapping to provide an opening of nominal size X mm not exceeding 100mm on existing blank flange. X = 50 |
| 042008 | Hot tapping to provide an opening of nominal size X mm not exceeding 100mm on existing blank flange. X = 100 |
| 042009 | Hot tapping to provide an opening of nominal size X mm exceeding 100mm by using electricity or hydraulic driven machine on existing blank flange:- X=150 |
| 042010 | Hot tapping to provide an opening of nominal size X mm exceeding 100mm by using electricity or hydraulic driven machine on existing blank flange:- X=200 |
| 042011 | Hot tapping to provide an opening of nominal size X mm exceeding 100mm by using electricity or hydraulic driven machine on existing blank flange:- X=250 |
| 042012 | Hot tapping to provide an opening of nominal size X mm exceeding 100mm by using electricity or hydraulic driven machine on existing blank flange:- X=300 |
| 043001A | Remove for reuse and refix brick or precast concrete valve chamber and metal covers Smaller than 180 mm x 180 mm. temporary road reinstatement |
| 043001B | Remove for reuse and refix brick or precast concrete valve chamber and metal covers Smaller than 180 mm x 180 mm. permanent road reinstatement |
| 043001C | Remove for reuse and refix brick or precast concrete valve chamber and metal covers Smaller than 180 mm x 180 mm. unpaved area, turfed and verge area and the like |
| 043002A | Remove for reuse and refix brick or precast concrete valve chamber and metal covers 180 mm x 180 mm. temporary road reinstatement |
| 043002B | Remove for reuse and refix brick or precast concrete valve chamber and metal covers 180 mm x 180 mm. permanent road reinstatement |
| 043002C | Remove for reuse and refix brick or precast concrete valve chamber and metal covers 180 mm x 180 mm. unpaved area, turfed and verge area and the like |
| 043003A | Remove for reuse and refix brick or precast concrete valve chamber and metal covers 300 mm x 200 mm or 285 mm x 200 mm. temporary road reinstatement |
| 043003B | Remove for reuse and refix brick or precast concrete valve chamber and metal covers 300 mm x 200 mm or 285 mm x 200 mm. permanent road reinstatement |
| 043003C | Remove for reuse and refix brick or precast concrete valve chamber and metal covers 300 mm x 200 mm or 285 mm x 200 mm . unpaved area, turfed and verge area and the like |
| 043004A | Remove for reuse and refix brick or precast concrete valve chamber and metal covers 300 mm x 300 mm. temporary road reinstatement |
| 043004B | Remove for reuse and refix brick or precast concrete valve chamber and metal covers 300 mm x 300 mm. permanent road reinstatement |
| 043004C | Remove for reuse and refix brick or precast concrete valve chamber and metal covers 300 mm x 300 mm. unpaved area, turfed and verge area and the like |
| 043005A | Remove for reuse and refix brick or precast concrete valve chamber and metal covers Larger than 300 mm x 300 mm. temporary road reinstatement |
| 043005B | Remove for reuse and refix brick or precast concrete valve chamber and metal covers Larger than 300 mm x 300 mm. permanent road reinstatement |
| 043005C | Remove for reuse and refix brick or precast concrete valve chamber and metal covers Larger than 300 mm x 300 mm. unpaved area, turfed and verge area and the like |
| 043006A | Replace sluice valves/gate valves buried underground 100 mm or smaller sluice valve/gate valve. temporary road reinstatement |
| 043006B | Replace sluice valves/gate valves buried underground 100 mm or smaller sluice valve/gate valve. permanent road reinstatement |
| 043006C | Replace sluice valves/gate valves buried underground 100 mm or smaller sluice valve/gate valve. unpaved area, turfed and verge area and the like |
| 043007A | Replace sluice valves/gate valves buried underground 150 mm sluice valve. temporary road reinstatement |
| 043007B | Replace sluice valves/gate valves buried underground 150 mm sluice valve. permanent road reinstatement |
| 043007C | Replace sluice valves/gate valves buried underground 150 mm sluice valve. unpaved area, turfed and verge area and the like |
| 043008A | Replace sluice valves/gate valves buried underground 200 mm sluice valve. temporary road reinstatement |
| 043008B | Replace sluice valves/gate valves buried underground 200 mm sluice valve. permanent road reinstatement |
| 043008C | Replace sluice valves/gate valves buried underground 200 mm sluice valve. unpaved area, turfed and verge area and the like |
| 043009A | Replace sluice valves/gate valves buried underground 250 mm sluice valve. temporary road reinstatement |
| 043009B | Replace sluice valves/gate valves buried underground 250 mm sluice valve. permanent road reinstatement |
| 043009C | Replace sluice valves/gate valves buried underground 250 mm sluice valve. unpaved area, turfed and verge area and the like |
| 043010A | Replace sluice valves/gate valves buried underground 300 mm sluice valve. temporary road reinstatement |
| 043010B | Replace sluice valves/gate valves buried underground 300 mm sluice valve. permanent road reinstatement |
| 043010C | Replace sluice valves/gate valves buried underground 300 mm sluice valve. unpaved area, turfed and verge area and the like |
| 043011A | Replace sluice valves/gate valves buried underground 375 mm sluice valve. temporary road reinstatement |
| 043011B | Replace sluice valves/gate valves buried underground 375 mm sluice valve. permanent road reinstatement |
| 043011C | Replace sluice valves/gate valves buried underground 375 mm sluice valve. unpaved area, turfed and verge area and the like |
| 043012A | Replace sluice valves/gate valves buried underground 400 mm sluice valve. temporary road reinstatement |
| 043012B | Replace sluice valves/gate valves buried underground 400 mm sluice valve. permanent road reinstatement |
| 043012C | Replace sluice valves/gate valves buried underground 400 mm sluice valve. unpaved area, turfed and verge area and the like |
| 043013A | Adjust and refix existing metal valve cover Smaller than 180 mm x 180 mm. temporary road reinstatement |
| 043013B | Adjust and refix existing metal valve cover Smaller than 180 mm x 180 mm. permanent road reinstatement |
| 043013C | Adjust and refix existing metal valve cover Smaller than 180 mm x 180 mm. unpaved area, turfed and verge area and the like |
| 043014A | Adjust and refix existing metal valve cover 180 mm x 180 mm. temporary road reinstatement |
| 043014B | Adjust and refix existing metal valve cover 180 mm x 180 mm. permanent road reinstatement |
| 043014C | Adjust and refix existing metal valve cover 180 mm x 180 mm. unpaved area, turfed and verge area and the like |
| 043015A | Adjust and refix existing metal valve cover 300 mm x 200 mm or 285 mm x 200 mm. temporary road reinstatement |
| 043015B | Adjust and refix existing metal valve cover 300 mm x 200 mm or 285 mm x 200 mm. permanent road reinstatement |
| 043015C | Adjust and refix existing metal valve cover 300 mm x 200 mm or 285 mm x 200 mm . unpaved area, turfed and verge area and the like |
| 043016A | Adjust and refix existing metal valve cover 300 mm x 300 mm. temporary road reinstatement |
| 043016B | Adjust and refix existing metal valve cover 300 mm x 300 mm. permanent road reinstatement |
| 043016C | Adjust and refix existing metal valve cover 300 mm x 300 mm. unpaved area, turfed and verge area and the like |
| 043017A | Adjust and refix existing metal valve cover Larger than 300 mm x 300 mm. temporary road reinstatement |
| 043017B | Adjust and refix existing metal valve cover Larger than 300 mm x 300 mm. permanent road reinstatement |
| 043017C | Adjust and refix existing metal valve cover Larger than 300 mm x 300 mm. unpaved area, turfed and verge area and the like |
| 043018A | Remove for re-use and refix brick or precast concrete value chamber and replace with new C.I. covers smaller than 180 mm x 180 mm. temporary road reinstatement |
| 043018B | Remove for re-use and refix brick or precast concrete value chamber and replace with new C.I. covers smaller than 180 mm x 180 mm. permanent road reinstatement |
| 043018C | Remove for re-use and refix brick or precast concrete value chamber and replace with new C.I. covers smaller than 180 mm x 180 mm. unpaved area, turfed and verge area and the like |
| 043019A | Remove for re-use and refix brick or precast concrete value chamber and replace with new C.I. covers 180 mm x 180 mm. temporary road reinstatement |
| 043019B | Remove for re-use and refix brick or precast concrete value chamber and replace with new C.I. covers 180 mm x 180 mm. permanent road reinstatement |
| 043019C | Remove for re-use and refix brick or precast concrete value chamber and replace with new C.I. covers 180 mm x 180 mm. unpaved area, turfed and verge area and the like |
| 043020A | Remove for re-use and refix brick or precast concrete value chamber and replace with new C.I. covers 285 mm x 200 mm. temporary road reinstatement |
| 043020B | Remove for re-use and refix brick or precast concrete value chamber and replace with new C.I. covers 285 mm x 200 mm. permanent road reinstatement |
| 043020C | Remove for re-use and refix brick or precast concrete value chamber and replace with new C.I. covers 285 mm x 200 mm. unpaved area, turfed and verge area and the like |
| 043021A | Remove for re-use and refix brick or precast concrete value chamber and replace with new D.I. covers smaller than 180 mm x 180 mm. temporary road reinstatement |
| 043021B | Remove for re-use and refix brick or precast concrete value chamber and replace with new D.I. covers smaller than 180 mm x 180 mm. permanent road reinstatement |
| 043021C | Remove for re-use and refix brick or precast concrete value chamber and replace with new D.I. covers smaller than 180 mm x 180 mm. unpaved area, turfed and verge area and the like |
| 043022A | Remove for re-use and refix brick or precast concrete value chamber and replace with new D.I. covers 180 mm x 180 mm. temporary road reinstatement |
| 043022B | Remove for re-use and refix brick or precast concrete value chamber and replace with new D.I. covers 180 mm x 180 mm. permanent road reinstatement |
| 043022C | Remove for re-use and refix brick or precast concrete value chamber and replace with new D.I. covers 180 mm x 180 mm. unpaved area, turfed and verge area and the like |
| 043023A | Remove for re-use and refix bick or precast concrete value chamber and replace with new D.I. covers 285 mm x 200 mm. temporary road reinstatement |
| 043023B | Remove for re-use and refix brick or precast concrete value chamber and replace with new D.I. covers 285 mm x 200 mm. permanent road reinstatement |
| 043023C | Remove for re-use and refix brick or precast concrete value chamber and replace with new D.I. covers 285 mm x 200 mm. unpaved area, turfed and verge area and the like |
| 043024A | Remove for re-use and refix brick or precast concrete value chamber and replace with new D.I. covers 300 mm x 300 mm. temporary road reinstatement |
| 043024B | Remove for re-use and refix brick or precast concrete value chamber and replace with new D.I. covers 300 mm x 300 mm. permanent road reinstatement |
| 043024C | Remove for re-use and refix brick or precast concrete value chamber and replace with new D.I. covers 300 mm x 300 mm. unpaved area, turfed and verge area and the like |
| 043025A | Remove for re-use and refix brick or precast concrete value chamber and replace with new D.I. covers 300 mm x 300 mm, but for frame 150mm thick. temporary road reinstatement |
| 043025B | Remove for re-use and refix brick or precast concrete value chamber and replace with new D.I. covers 300 mm x 300 mm, but for frame 150mm thick. permanent road reinstatement |
| 043025C | Remove for re-use and refix brick or precast concrete value chamber and replace with new D.I. covers 300 mm x 300 mm, but for frame 150mm thick. unpaved area, turfed and verge area and the like |
| 043026A | Remove for re-use and refix brick or precast concrete value chamber and replace with new D.I. covers Larger than 300 mm x 300 mm. temporary road reinstatement |
| 043026B | Remove for re-use and refix brick or precast concrete value chamber and replace with new D.I. covers Larger than 300 mm x 300 mm. permanent road reinstatement |
| 043026C | Remove for re-use and refix brick or precast concrete value chamber and replace with new D.I. covers Larger than 300 mm x 300 mm. unpaved area, turfed and verge area and the like |
| 043027A | Remove for re-use and refix brick or precast concrete value chamber and replace with new M.S. covers Larger than 300 mm x 300 mm. temporary road reinstatement |
| 043027B | Remove for re-use and refix brick or precast concrete value chamber and replace with new M.S. covers Larger than 300 mm x 300 mm. permanent road reinstatement |
| 043027C | Remove for re-use and refix brick or precast concrete value chamber and replace with new M.S. covers Larger than 300 mm x 300 mm. unpaved area, turfed and verge area and the like |
| 043028a | Adjust and replace with new C.I. covers Smaller than 180 mm x 180 mm. temporary road reinstatement |
| 043028b | Adjust and replace with new C.I. covers Smaller than 180 mm x 180 mm. permanent road reinstatement |
| 043028c | Adjust and replace with new C.I. covers Smaller than 180 mm x 180 mm. unpaved area, turfed and verge area and the like |
| 043029a | Adjust and replace with new C.I. covers 180 mm x 180 mm. temporary road reinstatement |
| 043029b | Adjust and replace with new C.I. covers 180 mm x 180 mm. permanent road reinstatement |
| 043029c | Adjust and replace with new C.I. covers 180 mm x 180 mm. unpaved area, turfed and verge area and the like |
| 043030a | Adjust and replace with new C.I. covers 285 mm x 200 mm. temporary road reinstatement |
| 043030b | Adjust and replace with new C.I. covers 285 mm x 200 mm. permanent road reinstatement |
| 043030c | Adjust and replace with new C.I. covers 285 mm x 200 mm. unpaved area, turfed and verge area and the like |
| 043031a | Adjust and replace with new D.I. covers Smaller than 180 mm x 180 mm. temporary road reinstatement |
| 043031b | Adjust and replace with new D.I. covers Smaller than 180 mm x 180 mm. permanent road reinstatement |
| 043031c | Adjust and replace with new D.I. covers Smaller than 180 mm x 180 mm. unpaved area, turfed and verge area and the like |
| 043032a | Adjust and replace with new D.I. covers 180 mm x 180 mm. temporary road reinstatement |
| 043032b | Adjust and replace with new D.I. covers 180 mm x 180 mm. permanent road reinstatement |
| 043032c | Adjust and replace with new D.I. covers 180 mm x 180 mm. unpaved area, turfed and verge area and the like |
| 043033a | Adjust and replace with new D.I. covers 285 mm x 200 mm. temporary road reinstatement |
| 043033b | Adjust and replace with new D.I. covers 285 mm x 200 mm. permanent road reinstatement |
| 043033c | Adjust and replace with new D.I. covers 285 mm x 200 mm. unpaved area, turfed and verge area and the like |
| 043034a | Adjust and replace with new D.I. covers 300 mm x 300 mm. temporary road reinstatement |
| 043034b | Adjust and replace with new D.I. covers 300 mm x 300 mm. permanent road reinstatement |
| 043034c | Adjust and replace with new D.I. covers 300 mm x 300 mm. unpaved area, turfed and verge area and the like |
| 043035a | Adjust and replace with new D.I. covers 300 mm x 300 mm, but for frame 150mm thick. temporary road reinstatement |
| 043035b | Adjust and replace with new D.I. covers 300 mm x 300 mm, but for frame 150mm thick. permanent road reinstatement |
| 043035c | Adjust and replace with new D.I. covers 300 mm x 300 mm, but for frame 150mm thick. unpaved area, turfed and verge area and the like |
| 043036a | Adjust and replace with new D.I. covers Larger than 300 mm x 300 mm. temporary road reinstatement |
| 043036b | Adjust and replace with new D.I. covers Larger than 300 mm x 300 mm. permanent road reinstatement |
| 043036c | Adjust and replace with new D.I. covers Larger than 300 mm x 300 mm. unpaved area, turfed and verge area and the like |
| 043037a | Adjust and replace with new M.S. covers Larger than 300 mm x 300 mm. temporary road reinstatement |
| 043037b | Adjust and replace with new M.S. covers Larger than 300 mm x 300 mm. permanent road reinstatement |
| 043037c | Adjust and replace with new M.S. covers Larger than 300 mm x 300 mm. unpaved area, turfed and verge area and the like |
| 043038 | Supply and install keyhole plug (SafePRO® EzeePlug® Model EP-04N with grey colour unless otherwise specified, or equivalent as approved by the Engineer) on cover's keyhole |
| 045001A | Installation of tee connection off completed and buried pipeline Tee-connection in carriageway, for temporary road reinstatement. Size of pipe off which connection is to be made 50 mm & under |
| 045001B | Installation of tee connection off completed and buried pipeline Tee-connection in carriageway, for temporary road reinstatement. Size of pipe off which connection is to be made 80 mm |
| 045001C | Installation of tee connection off completed and buried pipeline Tee-connection in carriageway, for temporary road reinstatement. Size of pipe off which connection is to be made 100 mm |
| 045001D | Installation of tee connection off completed and buried pipeline Tee-connection in carriageway, for temporary road reinstatement. Size of pipe off which connection is to be made 150 mm |
| 045001E | Installation of tee connection off completed and buried pipeline Tee-connection in carriageway, for temporary road reinstatement. Size of pipe off which connection is to be made 200 mm |
| 045001F | Installation of tee connection off completed and buried pipeline Tee-connection in carriageway, for temporary road reinstatement. Size of pipe off which connection is to be made 250 mm |
| 045001G | Installation of tee connection off completed and buried pipeline Tee-connection in carriageway, for temporary road reinstatement. Size of pipe off which connection is to be made 300 mm |
| 045001H | Installation of tee connection off completed and buried pipeline Tee-connection in carriageway, for temporary road reinstatement. Size of pipe off which connection is to be made 375 mm |
| 045001I | Installation of tee connection off completed and buried pipeline Tee-connection in carriageway, for temporary road reinstatement. Size of pipe off which connection is to be made 400 mm |
| 045002A | Installation of tee connection off completed and buried pipeline Tee-connection in carriageway, for temporary road reinstatement using saddle tee of PE Pipe. Size of pipe off which connection is to be made 50 mm & under |
| 045002B | Installation of tee connection off completed and buried pipeline Tee-connection in carriageway, for temporary road reinstatement using saddle tee of PE Pipe. Size of pipe off which connection is to be made 80 mm |
| 045002C | Installation of tee connection off completed and buried pipeline Tee-connection in carriageway, for temporary road reinstatement using saddle tee of PE Pipe. Size of pipe off which connection is to be made 100 mm |
| 045002D | Installation of tee connection off completed and buried pipeline Tee-connection in carriageway, for temporary road reinstatement using saddle tee of PE Pipe. Size of pipe off which connection is to be made 150 mm |
| 045002E | Installation of tee connection off completed and buried pipeline Tee-connection in carriageway, for temporary road reinstatement using saddle tee of PE Pipe. Size of pipe off which connection is to be made 200 mm |
| 045002F | Installation of tee connection off completed and buried pipeline Tee-connection in carriageway, for temporary road reinstatement using saddle tee of PE Pipe. Size of pipe off which connection is to be made 250 mm |
| 045003A | Installation of tee connection off completed and buried pipeline Tee-connection in footpath or cycle track, for temporary road reinstatement. Size of pipe off which connection is to be made 50 mm & under |
| 045003B | Installation of tee connection off completed and buried pipeline Tee-connection in footpath or cycle track, for temporary road reinstatement. Size of pipe off which connection is to be made 80 mm |
| 045003C | Installation of tee connection off completed and buried pipeline Tee-connection in footpath or cycle track, for temporary road reinstatement. Size of pipe off which connection is to be made 100 mm |
| 045003D | Installation of tee connection off completed and buried pipeline Tee-connection in footpath or cycle track, for temporary road reinstatement. Size of pipe off which connection is to be made 150 mm |
| 045003E | Installation of tee connection off completed and buried pipeline Tee-connection in footpath or cycle track, for temporary road reinstatement. Size of pipe off which connection is to be made 200 mm |
| 045003F | Installation of tee connection off completed and buried pipeline Tee-connection in footpath or cycle track, for temporary road reinstatement. Size of pipe off which connection is to be made 250 mm |
| 045003G | Installation of tee connection off completed and buried pipeline Tee-connection in footpath or cycle track, for temporary road reinstatement. Size of pipe off which connection is to be made 300 mm |
| 045003H | Installation of tee connection off completed and buried pipeline Tee-connection in footpath or cycle track, for temporary road reinstatement. Size of pipe off which connection is to be made 375 mm |
| 045003I | Installation of tee connection off completed and buried pipeline Tee-connection in footpath or cycle track, for temporary road reinstatement. Size of pipe off which connection is to be made 400 mm |
| 045004A | Installation of tee connection off completed and buried pipeline Tee-connection in footpath or cycle track, for temporary road reinstatement using saddle tee of PE Pipe. Size of pipe off which connection is to be made 50 mm & under |
| 045004B | Installation of tee connection off completed and buried pipeline Tee-connection in footpath or cycle track, for temporary road reinstatement using saddle tee of PE Pipe. Size of pipe off which connection is to be made 80 mm |
| 045004C | Installation of tee connection off completed and buried pipeline Tee-connection in footpath or cycle track, for temporary road reinstatement using saddle tee of PE Pipe. Size of pipe off which connection is to be made 100 mm |
| 045004D | Installation of tee connection off completed and buried pipeline Tee-connection in footpath or cycle track, for temporary road reinstatement using saddle tee of PE Pipe. Size of pipe off which connection is to be made 150 mm |
| 045004E | Installation of tee connection off completed and buried pipeline Tee-connection in footpath or cycle track, for temporary road reinstatement using saddle tee of PE Pipe. Size of pipe off which connection is to be made 200 mm |
| 045004F | Installation of tee connection off completed and buried pipeline Tee-connection in footpath or cycle track, for temporary road reinstatement using saddle tee of PE Pipe. Size of pipe off which connection is to be made 250 mm |
| 045005A | Installation of tee connection off completed and buried pipeline Tee-connection in carriageway, for permanent road reinstatement. Size of pipe off which connection is to be made 50 mm & under |
| 045005B | Installation of tee connection off completed and buried pipeline Tee-connection in carriageway, for permanent road reinstatement. Size of pipe off which connection is to be made 80 mm |
| 045005C | Installation of tee connection off completed and buried pipeline Tee-connection in carriageway, for permanent road reinstatement. Size of pipe off which connection is to be made 100 mm |
| 045005D | Installation of tee connection off completed and buried pipeline Tee-connection in carriageway, for permanent road reinstatement. Size of pipe off which connection is to be made 150 mm |
| 045005E | Installation of tee connection off completed and buried pipeline Tee-connection in carriageway, for permanent road reinstatement. Size of pipe off which connection is to be made 200 mm |
| 045005F | Installation of tee connection off completed and buried pipeline Tee-connection in carriageway, for permanent road reinstatement. Size of pipe off which connection is to be made 250 mm |
| 045005G | Installation of tee connection off completed and buried pipeline Tee-connection in carriageway, for permanent road reinstatement. Size of pipe off which connection is to be made 300 mm |
| 045005H | Installation of tee connection off completed and buried pipeline Tee-connection in carriageway, for permanent road reinstatement. Size of pipe off which connection is to be made 375 mm |
| 045005I | Installation of tee connection off completed and buried pipeline Tee-connection in carriageway, for permanent road reinstatement. Size of pipe off which connection is to be made 400 mm |
| 045006A | Installation of tee connection off completed and buried pipeline Tee-connection in carriageway, for permanent road reinstatement using saddle tee of PE Pipe. Size of pipe off which connection is to be made 50 mm & under |
| 045006B | Installation of tee connection off completed and buried pipeline Tee-connection in carriageway, for permanent road reinstatement using saddle tee of PE Pipe. Size of pipe off which connection is to be made 80 mm |
| 045006C | Installation of tee connection off completed and buried pipeline Tee-connection in carriageway, for permanent road reinstatement using saddle tee of PE Pipe. Size of pipe off which connection is to be made 100 mm |
| 045006D | Installation of tee connection off completed and buried pipeline Tee-connection in carriageway, for permanent road reinstatement using saddle tee of PE Pipe. Size of pipe off which connection is to be made 150 mm |
| 045006E | Installation of tee connection off completed and buried pipeline Tee-connection in carriageway, for permanent road reinstatement using saddle tee of PE Pipe. Size of pipe off which connection is to be made 200 mm |
| 045006F | Installation of tee connection off completed and buried pipeline Tee-connection in carriageway, for permanent road reinstatement using saddle tee of PE Pipe. Size of pipe off which connection is to be made 250 mm |
| 045007A | Installation of tee connection off completed and buried pipeline Tee-connection in footpath or cycle track, for permanent road reinstatement. Size of pipe off which connection is to be made 50 mm & under |
| 045007B | Installation of tee connection off completed and buried pipeline Tee-connection in footpath or cycle track, for permanent road reinstatement. Size of pipe off which connection is to be made 80 mm |
| 045007C | Installation of tee connection off completed and buried pipeline Tee-connection in footpath or cycle track, for permanent road reinstatement. Size of pipe off which connection is to be made 100 mm |
| 045007D | Installation of tee connection off completed and buried pipeline Tee-connection in footpath or cycle track, for permanent road reinstatement. Size of pipe off which connection is to be made 150 mm |
| 045007E | Installation of tee connection off completed and buried pipeline Tee-connection in footpath or cycle track, for permanent road reinstatement. Size of pipe off which connection is to be made 200 mm |
| 045007F | Installation of tee connection off completed and buried pipeline Tee-connection in footpath or cycle track, for permanent road reinstatement. Size of pipe off which connection is to be made 250 mm |
| 045007G | Installation of tee connection off completed and buried pipeline Tee-connection in footpath or cycle track, for permanent road reinstatement. Size of pipe off which connection is to be made 300 mm |
| 045007H | Installation of tee connection off completed and buried pipeline Tee-connection in footpath or cycle track, for permanent road reinstatement. Size of pipe off which connection is to be made 375 mm |
| 045007I | Installation of tee connection off completed and buried pipeline Tee-connection in footpath or cycle track, for permanent road reinstatement. Size of pipe off which connection is to be made 400 mm |
| 045008A | Installation of tee connection off completed and buried pipeline Tee-connection in footpath or cycle track, for permanent road reinstatement using saddle tee of PE Pipe. Size of pipe off which connection is to be made 50 mm & under |
| 045008B | Installation of tee connection off completed and buried pipeline Tee-connection in footpath or cycle track, for permanent road reinstatement using saddle tee of PE Pipe. Size of pipe off which connection is to be made 80 mm |
| 045008C | Installation of tee connection off completed and buried pipeline Tee-connection in footpath or cycle track, for permanent road reinstatement using saddle tee of PE Pipe. Size of pipe off which connection is to be made 100 mm |
| 045008D | Installation of tee connection off completed and buried pipeline Tee-connection in footpath or cycle track, for permanent road reinstatement using saddle tee of PE Pipe. Size of pipe off which connection is to be made 150 mm |
| 045008E | Installation of tee connection off completed and buried pipeline Tee-connection in footpath or cycle track, for permanent road reinstatement using saddle tee of PE Pipe. Size of pipe off which connection is to be made 200 mm |
| 045008F | Installation of tee connection off completed and buried pipeline Tee-connection in footpath or cycle track, for permanent road reinstatement using saddle tee of PE Pipe. Size of pipe off which connection is to be made 250 mm |
| 045009A | Installation of tee connection off completed and buried pipeline Tee-connection in unpaved area, turfed and verge area and the like. Size of pipe off which connection is to be made 50 mm & under |
| 045009B | Installation of tee connection off completed and buried pipeline Tee-connection in unpaved area, turfed and verge area and the like. Size of pipe off which connection is to be made 80 mm |
| 045009C | Installation of tee connection off completed and buried pipeline Tee-connection in unpaved area, turfed and verge area and the like. Size of pipe off which connection is to be made 100 mm |
| 045009D | Installation of tee connection off completed and buried pipeline Tee-connection in unpaved area, turfed and verge area and the like. Size of pipe off which connection is to be made 150 mm |
| 045009E | Installation of tee connection off completed and buried pipeline Tee-connection in unpaved area, turfed and verge area and the like. Size of pipe off which connection is to be made 200 mm |
| 045009F | Installation of tee connection off completed and buried pipeline Tee-connection in unpaved area, turfed and verge area and the like. Size of pipe off which connection is to be made 250 mm |
| 045009G | Installation of tee connection off completed and buried pipeline Tee-connection in unpaved area, turfed and verge area and the like. Size of pipe off which connection is to be made 300 mm |
| 045009H | Installation of tee connection off completed and buried pipeline Tee-connection in unpaved area, turfed and verge area and the like. Size of pipe off which connection is to be made 375 mm |
| 045009I | Installation of tee connection off completed and buried pipeline Tee-connection in unpaved area, turfed and verge area and the like. Size of pipe off which connection is to be made 400 mm |
| 045010A | Installation of tee connection off completed and buried pipeline Tee-connection in unpaved area, turfed and verge area and the like using saddle tee of PE Pipe. Size of pipe off which connection is to be made 50 mm & under |
| 045010B | Installation of tee connection off completed and buried pipeline Tee-connection in unpaved area, turfed and verge area and the like using saddle tee of PE Pipe. Size of pipe off which connection is to be made 80 mm |
| 045010C | Installation of tee connection off completed and buried pipeline Tee-connection in unpaved area, turfed and verge area and the like using saddle tee of PE Pipe. Size of pipe off which connection is to be made 100 mm |
| 045010D | Installation of tee connection off completed and buried pipeline Tee-connection in unpaved area, turfed and verge area and the like using saddle tee of PE Pipe. Size of pipe off which connection is to be made 150 mm |
| 045010E | Installation of tee connection off completed and buried pipeline Tee-connection in unpaved area, turfed and verge area and the like using saddle tee of PE Pipe. Size of pipe off which connection is to be made 200 mm |
| 045010F | Installation of tee connection off completed and buried pipeline Tee-connection in unpaved area, turfed and verge area and the like using saddle tee of PE Pipe. Size of pipe off which connection is to be made 250 mm |
| 045011A | Installation of tee connection off completed and buried pipeline Branch pipe in carriageway between 2 m and 8 m from the pipe junction, for temporary road reinstatement. Size of branch pipe 50 mm & under |
| 045011B | Installation of tee connection off completed and buried pipeline Branch pipe in carriageway between 2 m and 8 m from the pipe junction, for temporary road reinstatement. Size of branch pipe 80 mm |
| 045011C | Installation of tee connection off completed and buried pipeline Branch pipe in carriageway between 2 m and 8 m from the pipe junction, for temporary road reinstatement. Size of branch pipe 100 mm |
| 045011D | Installation of tee connection off completed and buried pipeline Branch pipe in carriageway between 2 m and 8 m from the pipe junction, for temporary road reinstatement. Size of branch pipe 150 mm |
| 045011E | Installation of tee connection off completed and buried pipeline Branch pipe in carriageway between 2 m and 8 m from the pipe junction, for temporary road reinstatement. Size of branch pipe 200 mm |
| 045011F | Installation of tee connection off completed and buried pipeline Branch pipe in carriageway between 2 m and 8 m from the pipe junction, for temporary road reinstatement. Size of branch pipe 250 mm |
| 045011G | Installation of tee connection off completed and buried pipeline Branch pipe in carriageway between 2 m and 8 m from the pipe junction, for temporary road reinstatement. Size of branch pipe 300 mm |
| 045011H | Installation of tee connection off completed and buried pipeline Branch pipe in carriageway between 2 m and 8 m from the pipe junction, for temporary road reinstatement. Size of branch pipe 375 mm |
| 045011I | Installation of tee connection off completed and buried pipeline Branch pipe in carriageway between 2 m and 8 m from the pipe junction, for temporary road reinstatement. Size of branch pipe 400 mm |
| 045012A | Installation of tee connection off completed and buried pipeline Branch pipe in footpath or cycle track between 2 m and 8 m from the pipe junction, for temporary road reinstatement. Size of branch pipe 50 mm & under |
| 045012B | Installation of tee connection off completed and buried pipeline Branch pipe in footpath or cycle track between 2 m and 8 m from the pipe junction, for temporary road reinstatement. Size of branch pipe 80 mm |
| 045012C | Installation of tee connection off completed and buried pipeline Branch pipe in footpath or cycle track between 2 m and 8 m from the pipe junction, for temporary road reinstatement. Size of branch pipe 100 mm |
| 045012D | Installation of tee connection off completed and buried pipeline Branch pipe in footpath or cycle track between 2 m and 8 m from the pipe junction, for temporary road reinstatement. Size of branch pipe 150 mm |
| 045012E | Installation of tee connection off completed and buried pipeline Branch pipe in footpath or cycle track between 2 m and 8 m from the pipe junction, for temporary road reinstatement. Size of branch pipe 200 mm |
| 045012F | Installation of tee connection off completed and buried pipeline Branch pipe in footpath or cycle track between 2 m and 8 m from the pipe junction, for temporary road reinstatement. Size of branch pipe 250 mm |
| 045012G | Installation of tee connection off completed and buried pipeline Branch pipe in footpath or cycle track between 2 m and 8 m from the pipe junction, for temporary road reinstatement. Size of branch pipe 300 mm |
| 045012H | Installation of tee connection off completed and buried pipeline Branch pipe in footpath or cycle track between 2 m and 8 m from the pipe junction, for temporary road reinstatement. Size of branch pipe 375 mm |
| 045012I | Installation of tee connection off completed and buried pipeline Branch pipe in footpath or cycle track between 2 m and 8 m from the pipe junction, for temporary road reinstatement. Size of branch pipe 400 mm |
| 045013A | Installation of tee connection off completed and buried pipeline Branch pipe in carriageway between 2 m and 8 m from the pipe junction, for permanent road reinstatement. Size of branch pipe 50 mm & under |
| 045013B | Installation of tee connection off completed and buried pipeline Branch pipe in carriageway between 2 m and 8 m from the pipe junction, for permanent road reinstatement. Size of branch pipe 80 mm |
| 045013C | Installation of tee connection off completed and buried pipeline Branch pipe in carriageway between 2 m and 8 m from the pipe junction, for permanent road reinstatement. Size of branch pipe 100 mm |
| 045013D | Installation of tee connection off completed and buried pipeline Branch pipe in carriageway between 2 m and 8 m from the pipe junction, for permanent road reinstatement. Size of branch pipe 150 mm |
| 045013E | Installation of tee connection off completed and buried pipeline Branch pipe in carriageway between 2 m and 8 m from the pipe junction, for permanent road reinstatement. Size of branch pipe 200 mm |
| 045013F | Installation of tee connection off completed and buried pipeline Branch pipe in carriageway between 2 m and 8 m from the pipe junction, for permanent road reinstatement. Size of branch pipe 250 mm |
| 045013G | Installation of tee connection off completed and buried pipeline Branch pipe in carriageway between 2 m and 8 m from the pipe junction, for permanent road reinstatement. Size of branch pipe 300 mm |
| 045013H | Installation of tee connection off completed and buried pipeline Branch pipe in carriageway between 2 m and 8 m from the pipe junction, for permanent road reinstatement. Size of branch pipe 375 mm |
| 045013I | Installation of tee connection off completed and buried pipeline Branch pipe in carriageway between 2 m and 8 m from the pipe junction, for permanent road reinstatement. Size of branch pipe 400 mm |
| 045014A | Installation of tee connection off completed and buried pipeline Branch pipe in footpath or cycle track between 2 m and 8 m from the pipe junction, for permanent road reinstatement. Size of branch pipe 50 mm & under |
| 045014B | Installation of tee connection off completed and buried pipeline Branch pipe in footpath or cycle track between 2 m and 8 m from the pipe junction, for permanent road reinstatement. Size of branch pipe 80 mm |
| 045014C | Installation of tee connection off completed and buried pipeline Branch pipe in footpath or cycle track between 2 m and 8 m from the pipe junction, for permanent road reinstatement. Size of branch pipe 100 mm |
| 045014D | Installation of tee connection off completed and buried pipeline Branch pipe in footpath or cycle track between 2 m and 8 m from the pipe junction, for permanent road reinstatement. Size of branch pipe 150 mm |
| 045014E | Installation of tee connection off completed and buried pipeline Branch pipe in footpath or cycle track between 2 m and 8 m from the pipe junction, for permanent road reinstatement. Size of branch pipe 200 mm |
| 045014F | Installation of tee connection off completed and buried pipeline Branch pipe in footpath or cycle track between 2 m and 8 m from the pipe junction, for permanent road reinstatement. Size of branch pipe 250 mm |
| 045014G | Installation of tee connection off completed and buried pipeline Branch pipe in footpath or cycle track between 2 m and 8 m from the pipe junction, for permanent road reinstatement. Size of branch pipe 300 mm |
| 045014H | Installation of tee connection off completed and buried pipeline Branch pipe in footpath or cycle track between 2 m and 8 m from the pipe junction, for permanent road reinstatement. Size of branch pipe 375 mm |
| 045014I | Installation of tee connection off completed and buried pipeline Branch pipe in footpath or cycle track between 2 m and 8 m from the pipe junction, for permanent road reinstatement. Size of branch pipe 400 mm |
| 045015A | Installation of tee connection off completed and buried pipeline Branch pipe in unpaved area, turfed and verge area and the like between 2 m and 8 m from the pipe junction. Size of branch pipe 50 mm & under |
| 045015B | Installation of tee connection off completed and buried pipeline Branch pipe in unpaved area, turfed and verge area and the like between 2 m and 8 m from the pipe junction. Size of branch pipe 80 mm |
| 045015C | Installation of tee connection off completed and buried pipeline Branch pipe in unpaved area, turfed and verge area and the like between 2 m and 8 m from the pipe junction. Size of branch pipe 100 mm |
| 045015D | Installation of tee connection off completed and buried pipeline Branch pipe in unpaved area, turfed and verge area and the like between 2 m and 8 m from the pipe junction. Size of branch pipe 150 mm |
| 045015E | Installation of tee connection off completed and buried pipeline Branch pipe in unpaved area, turfed and verge area and the like between 2 m and 8 m from the pipe junction. Size of branch pipe 200 mm |
| 045015F | Installation of tee connection off completed and buried pipeline Branch pipe in unpaved area, turfed and verge area and the like between 2 m and 8 m from the pipe junction. Size of branch pipe 250 mm |
| 045015G | Installation of tee connection off completed and buried pipeline Branch pipe in unpaved area, turfed and verge area and the like between 2 m and 8 m from the pipe junction. Size of branch pipe 300 mm |
| 045015H | Installation of tee connection off completed and buried pipeline Branch pipe in unpaved area, turfed and verge area and the like between 2 m and 8 m from the pipe junction. Size of branch pipe 375 mm |
| 045015I | Installation of tee connection off completed and buried pipeline Branch pipe in unpaved area, turfed and verge area and the like between 2 m and 8 m from the pipe junction. Size of branch pipe 400 mm |
| 046001 | Installation of mechanical locking devices for Tyco valves of all sizes |
| 050001 | Paint round head, octagonal type or multi pillar point type pedestal hydrant as shown in Drawing Nos. WSM 4.3 and WSD 1.34, paint supplied by the Contractor. |
| 050002 | As Item No. 050/001 but paint supplied by the Employer. |
| 050003 | As Item No. 050/001 but for swan neck hydrant. |
| 050004 | As Item No. 050/002 but for swan neck hydrant. |
| 050005 | Paint hydrant valve cover as shown in Drawing No. WSD 7.26, paint supplied by the Contractor. |
| 050006 | As Item No. 050/005 but paint supplied by the Employer. |
| 051001A | Scrape and rub down old paint works for pipes and specials and prepare for repainting. Nominal diameter of pipe/valve 80mm & under |
| 051001B | Scrape and rub down old paint works for pipes and specials and prepare for repainting. Nominal diameter of pipe/valve 100 mm |
| 051001C | Scrape and rub down old paint works for pipes and specials and prepare for repainting. Nominal diameter of pipe/valve 125 -150 mm |
| 051001D | Scrape and rub down old paint works for pipes and specials and prepare for repainting. Nominal diameter of pipe/valve 200 mm |
| 051001E | Scrape and rub down old paint works for pipes and specials and prepare for repainting. Nominal diameter of pipe/valve 250 mm |
| 051001F | Scrape and rub down old paint works for pipes and specials and prepare for repainting. Nominal diameter of pipe/valve 300 mm |
| 051001G | Scrape and rub down old paint works for pipes and specials and prepare for repainting. Nominal diameter of pipe/valve 350 -375 mm |
| 051001H | Scrape and rub down old paint works for pipes and specials and prepare for repainting. Nominal diameter of pipe/valve 400 mm |
| 051001I | Scrape and rub down old paint works for pipes and specials and prepare for repainting. Nominal diameter of pipe/valve 450 mm |
| 051001J | Scrape and rub down old paint works for pipes and specials and prepare for repainting. Nominal diameter of pipe/valve 500 mm |
| 051001K | Scrape and rub down old paint works for pipes and specials and prepare for repainting. Nominal diameter of pipe/valve 525 mm |
| 051001L | Scrape and rub down old paint works for pipes and specials and prepare for repainting. Nominal diameter of pipe/valve 600 mm |
| 051001M | Scrape and rub down old paint works for pipes and specials and prepare for repainting. Nominal diameter of pipe/valve 675 mm |
| 051001N | Scrape and rub down old paint works for pipes and specials and prepare for repainting. Nominal diameter of pipe/valve 700 mm |
| 051001O | Scrape and rub down old paint works for pipes and specials and prepare for repainting. Nominal diameter of pipe/valve 750 mm |
| 051001P | Scrape and rub down old paint works for pipes and specials and prepare for repainting. Nominal diameter of pipe/valve 800 mm |
| 051001Q | Scrape and rub down old paint works for pipes and specials and prepare for repainting. Nominal diameter of pipe/valve 900 mm |
| 051001R | Scrape and rub down old paint works for pipes and specials and prepare for repainting. Nominal diameter of pipe/valve 1000 mm |
| 051001S | Scrape and rub down old paint works for pipes and specials and prepare for repainting. Nominal diameter of pipe/valve 1050 mm |
| 051001T | Scrape and rub down old paint works for pipes and specials and prepare for repainting. Nominal diameter of pipe/valve 1100 mm |
| 051001U | Scrape and rub down old paint works for pipes and specials and prepare for repainting. Nominal diameter of pipe/valve 1200 mm |
| 051001V | Scrape and rub down old paint works for pipes and specials and prepare for repainting. Nominal diameter of pipe/valve 1350 mm |
| 051001W | Scrape and rub down old paint works for pipes and specials and prepare for repainting. Nominal diameter of pipe/valve 1400 mm |
| 051001X | Scrape and rub down old paint works for pipes and specials and prepare for repainting. Nominal diameter of pipe/valve 1800 mm |
| 051001Y | Scrape and rub down old paint works for pipes and specials and prepare for repainting. Nominal diameter of pipe/valve 1950 - 2100 mm |
| 051001Z | Scrape and rub down old paint works for pipes and specials and prepare for repainting. Nominal diameter of pipe/valve >2100 mm |
| 051002(I)A | Paint pipework including priming with approved primer and one coat of approved paint - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 80mm & under |
| 051002(I)B | Paint pipework including priming with approved primer and one coat of approved paint - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 100 mm |
| 051002(I)C | Paint pipework including priming with approved primer and one coat of approved paint - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 125 -150 mm |
| 051002(I)D | Paint pipework including priming with approved primer and one coat of approved paint - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 200 mm |
| 051002(I)E | Paint pipework including priming with approved primer and one coat of approved paint - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 250 mm |
| 051002(I)F | Paint pipework including priming with approved primer and one coat of approved paint - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 300 mm |
| 051002(I)G | Paint pipework including priming with approved primer and one coat of approved paint - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 350 -375 mm |
| 051002(I)H | Paint pipework including priming with approved primer and one coat of approved paint - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 400 mm |
| 051002(I)I | Paint pipework including priming with approved primer and one coat of approved paint - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 450 mm |
| 051002(I)J | Paint pipework including priming with approved primer and one coat of approved paint - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 500 mm |
| 051002(I)K | Paint pipework including priming with approved primer and one coat of approved paint - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 525 mm |
| 051002(I)L | Paint pipework including priming with approved primer and one coat of approved paint - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 600 mm |
| 051002(I)M | Paint pipework including priming with approved primer and one coat of approved paint - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 675 mm |
| 051002(I)N | Paint pipework including priming with approved primer and one coat of approved paint - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 700 mm |
| 051002(I)O | Paint pipework including priming with approved primer and one coat of approved paint - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 750 mm |
| 051002(I)P | Paint pipework including priming with approved primer and one coat of approved paint - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 800 mm |
| 051002(I)Q | Paint pipework including priming with approved primer and one coat of approved paint - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 900 mm |
| 051002(I)R | Paint pipework including priming with approved primer and one coat of approved paint - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1000 mm |
| 051002(I)S | Paint pipework including priming with approved primer and one coat of approved paint - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1050 mm |
| 051002(I)T | Paint pipework including priming with approved primer and one coat of approved paint - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1100 mm |
| 051002(II)A | Paint pipework including priming with approved primer and one coat of approved paint - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 80mm & under |
| 051002(II)B | Paint pipework including priming with approved primer and one coat of approved paint - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 100 mm |
| 051002(II)C | Paint pipework including priming with approved primer and one coat of approved paint - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 125 -150 mm |
| 051002(II)D | Paint pipework including priming with approved primer and one coat of approved paint - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 200 mm |
| 051002(II)E | Paint pipework including priming with approved primer and one coat of approved paint - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 250 mm |
| 051002(II)F | Paint pipework including priming with approved primer and one coat of approved paint - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 300 mm |
| 051002(II)G | Paint pipework including priming with approved primer and one coat of approved paint - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 350 -375 mm |
| 051002(II)H | Paint pipework including priming with approved primer and one coat of approved paint - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 400 mm |
| 051002(II)I | Paint pipework including priming with approved primer and one coat of approved paint - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 450 mm |
| 051002(II)J | Paint pipework including priming with approved primer and one coat of approved paint - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 500 mm |
| 051002(II)K | Paint pipework including priming with approved primer and one coat of approved paint - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 525 mm |
| 051002(II)L | Paint pipework including priming with approved primer and one coat of approved paint - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 600 mm |
| 051002(II)M | Paint pipework including priming with approved primer and one coat of approved paint - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 675 mm |
| 051002(II)N | Paint pipework including priming with approved primer and one coat of approved paint - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 700 mm |
| 051002(II)O | Paint pipework including priming with approved primer and one coat of approved paint - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 750 mm |
| 051002(II)P | Paint pipework including priming with approved primer and one coat of approved paint - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 800 mm |
| 051002(II)Q | Paint pipework including priming with approved primer and one coat of approved paint - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 900 mm |
| 051002(II)R | Paint pipework including priming with approved primer and one coat of approved paint - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1000 mm |
| 051002(II)S | Paint pipework including priming with approved primer and one coat of approved paint - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1050 mm |
| 051002(II)T | Paint pipework including priming with approved primer and one coat of approved paint - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1100 mm |
| 051003(I)A | Extra over Item No. 051/002 for each extra coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 80mm & under |
| 051003(I)B | Extra over Item No. 051/002 for each extra coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 100 mm |
| 051003(I)C | Extra over Item No. 051/002 for each extra coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 125 -150 mm |
| 051003(I)D | Extra over Item No. 051/002 for each extra coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 200 mm |
| 051003(I)E | Extra over Item No. 051/002 for each extra coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 250 mm |
| 051003(I)F | Extra over Item No. 051/002 for each extra coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 300 mm |
| 051003(I)G | Extra over Item No. 051/002 for each extra coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 350 -375 mm |
| 051003(I)H | Extra over Item No. 051/002 for each extra coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 400 mm |
| 051003(I)I | Extra over Item No. 051/002 for each extra coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 450 mm |
| 051003(I)J | Extra over Item No. 051/002 for each extra coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 500 mm |
| 051003(I)K | Extra over Item No. 051/002 for each extra coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 525 mm |
| 051003(I)L | Extra over Item No. 051/002 for each extra coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 600 mm |
| 051003(I)M | Extra over Item No. 051/002 for each extra coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 675 mm |
| 051003(I)N | Extra over Item No. 051/002 for each extra coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 700 mm |
| 051003(I)O | Extra over Item No. 051/002 for each extra coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 750 mm |
| 051003(I)P | Extra over Item No. 051/002 for each extra coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 800 mm |
| 051003(I)Q | Extra over Item No. 051/002 for each extra coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 900 mm |
| 051003(I)R | Extra over Item No. 051/002 for each extra coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1000 mm |
| 051003(I)S | Extra over Item No. 051/002 for each extra coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1050 mm |
| 051003(I)T | Extra over Item No. 051/002 for each extra coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1100 mm |
| 051003(II)A | Extra over Item No. 051/002 for each extra coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 80mm & under |
| 051003(II)B | Extra over Item No. 051/002 for each extra coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 100 mm |
| 051003(II)C | Extra over Item No. 051/002 for each extra coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 125 -150 mm |
| 051003(II)D | Extra over Item No. 051/002 for each extra coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 200 mm |
| 051003(II)E | Extra over Item No. 051/002 for each extra coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 250 mm |
| 051003(II)F | Extra over Item No. 051/002 for each extra coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 300 mm |
| 051003(II)G | Extra over Item No. 051/002 for each extra coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 350 -375 mm |
| 051003(II)H | Extra over Item No. 051/002 for each extra coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 400 mm |
| 051003(II)I | Extra over Item No. 051/002 for each extra coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 450 mm |
| 051003(II)J | Extra over Item No. 051/002 for each extra coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 500 mm |
| 051003(II)K | Extra over Item No. 051/002 for each extra coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 525 mm |
| 051003(II)L | Extra over Item No. 051/002 for each extra coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 600 mm |
| 051003(II)M | Extra over Item No. 051/002 for each extra coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 675 mm |
| 051003(II)N | Extra over Item No. 051/002 for each extra coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 700 mm |
| 051003(II)O | Extra over Item No. 051/002 for each extra coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 750 mm |
| 051003(II)P | Extra over Item No. 051/002 for each extra coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 800 mm |
| 051003(II)Q | Extra over Item No. 051/002 for each extra coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 900 mm |
| 051003(II)R | Extra over Item No. 051/002 for each extra coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1000 mm |
| 051003(II)S | Extra over Item No. 051/002 for each extra coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1050 mm |
| 051003(II)T | Extra over Item No. 051/002 for each extra coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1100 mm |
| 051004(I)A | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 80mm & under |
| 051004(I)B | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 100 mm |
| 051004(I)C | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 125 -150 mm |
| 051004(I)D | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 200 mm |
| 051004(I)E | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 250 mm |
| 051004(I)F | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 300 mm |
| 051004(I)G | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 350 -375 mm |
| 051004(I)H | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 400 mm |
| 051004(I)I | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 450 mm |
| 051004(I)J | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 500 mm |
| 051004(I)K | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 525 mm |
| 051004(I)L | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 600 mm |
| 051004(I)M | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 675 mm |
| 051004(I)N | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 700 mm |
| 051004(I)O | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 750 mm |
| 051004(I)P | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 800 mm |
| 051004(I)Q | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 900 mm |
| 051004(I)R | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1000 mm |
| 051004(I)S | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1050 mm |
| 051004(I)T | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1100 mm |
| 051004(I)U | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1200 mm |
| 051004(I)V | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1350 mm |
| 051004(I)W | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1400 mm |
| 051004(I)X | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1800 mm |
| 051004(I)Y | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1950 - 2100 mm |
| 051004(I)Z | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve >2100 mm |
| 051004(II)A | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 80mm & under |
| 051004(II)B | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 100 mm |
| 051004(II)C | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 125 -150 mm |
| 051004(II)D | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 200 mm |
| 051004(II)E | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 250 mm |
| 051004(II)F | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 300 mm |
| 051004(II)G | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 350 -375 mm |
| 051004(II)H | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 400 mm |
| 051004(II)I | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 450 mm |
| 051004(II)J | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 500 mm |
| 051004(II)K | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 525 mm |
| 051004(II)L | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 600 mm |
| 051004(II)M | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 675 mm |
| 051004(II)N | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 700 mm |
| 051004(II)O | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 750 mm |
| 051004(II)P | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 800 mm |
| 051004(II)Q | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 900 mm |
| 051004(II)R | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1000 mm |
| 051004(II)S | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1050 mm |
| 051004(II)T | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1100 mm |
| 051004(II)U | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1200 mm |
| 051004(II)V | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1350 mm |
| 051004(II)W | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1400 mm |
| 051004(II)X | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1800 mm |
| 051004(II)Y | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1950 - 2100 mm |
| 051004(II)Z | Paint pipework with one coat of approved bitumen - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve >2100 mm |
| 051005(I)A | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 80mm & under |
| 051005(I)B | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 100 mm |
| 051005(I)C | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 125 -150 mm |
| 051005(I)D | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 200 mm |
| 051005(I)E | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 250 mm |
| 051005(I)F | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 300 mm |
| 051005(I)G | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 350 -375 mm |
| 051005(I)H | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 400 mm |
| 051005(I)I | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 450 mm |
| 051005(I)J | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 500 mm |
| 051005(I)K | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 525 mm |
| 051005(I)L | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 600 mm |
| 051005(I)M | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 675 mm |
| 051005(I)N | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 700 mm |
| 051005(I)O | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 750 mm |
| 051005(I)P | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 800 mm |
| 051005(I)Q | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 900 mm |
| 051005(I)R | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1000 mm |
| 051005(I)S | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1050 mm |
| 051005(I)T | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1100 mm |
| 051005(I)U | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1200 mm |
| 051005(I)V | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1350 mm |
| 051005(I)W | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1400 mm |
| 051005(I)X | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1800 mm |
| 051005(I)Y | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1950 - 2100 mm |
| 051005(I)Z | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve >2100 mm |
| 051005(II)A | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 80mm & under |
| 051005(II)B | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 100 mm |
| 051005(II)C | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 125 -150 mm |
| 051005(II)D | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 200 mm |
| 051005(II)E | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 250 mm |
| 051005(II)F | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 300 mm |
| 051005(II)G | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 350 -375 mm |
| 051005(II)H | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 400 mm |
| 051005(II)I | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 450 mm |
| 051005(II)J | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 500 mm |
| 051005(II)K | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 525 mm |
| 051005(II)L | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 600 mm |
| 051005(II)M | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 675 mm |
| 051005(II)N | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 700 mm |
| 051005(II)O | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 750 mm |
| 051005(II)P | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 800 mm |
| 051005(II)Q | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 900 mm |
| 051005(II)R | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1000 mm |
| 051005(II)S | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1050 mm |
| 051005(II)T | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1100 mm |
| 051005(II)U | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1200 mm |
| 051005(II)V | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1350 mm |
| 051005(II)W | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1400 mm |
| 051005(II)X | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1800 mm |
| 051005(II)Y | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1950 - 2100 mm |
| 051005(II)Z | Extra over Item No. 051/004 for each additional coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve >2100 mm |
| 051006(I)I | Paint pipework including priming with approved primer and one coat of approved epoxy paint - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 450 mm |
| 051006(I)J | Paint pipework including priming with approved primer and one coat of approved epoxy paint - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 500 mm |
| 051006(I)K | Paint pipework including priming with approved primer and one coat of approved epoxy paint - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 525 mm |
| 051006(I)L | Paint pipework including priming with approved primer and one coat of approved epoxy paint - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 600 mm |
| 051006(I)M | Paint pipework including priming with approved primer and one coat of approved epoxy paint - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 675 mm |
| 051006(I)N | Paint pipework including priming with approved primer and one coat of approved epoxy paint - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 700 mm |
| 051006(I)O | Paint pipework including priming with approved primer and one coat of approved epoxy paint - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 750 mm |
| 051006(I)P | Paint pipework including priming with approved primer and one coat of approved epoxy paint - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 800 mm |
| 051006(I)Q | Paint pipework including priming with approved primer and one coat of approved epoxy paint - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 900 mm |
| 051006(I)R | Paint pipework including priming with approved primer and one coat of approved epoxy paint - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1000 mm |
| 051006(I)S | Paint pipework including priming with approved primer and one coat of approved epoxy paint - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1050 mm |
| 051006(I)T | Paint pipework including priming with approved primer and one coat of approved epoxy paint - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1100 mm |
| 051006(I)U | Paint pipework including priming with approved primer and one coat of approved epoxy paint - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1200 mm |
| 051006(I)V | Paint pipework including priming with approved primer and one coat of approved epoxy paint - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1350 mm |
| 051006(I)W | Paint pipework including priming with approved primer and one coat of approved epoxy paint - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1400 mm |
| 051006(I)X | Paint pipework including priming with approved primer and one coat of approved epoxy paint - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1800 mm |
| 051006(I)Y | Paint pipework including priming with approved primer and one coat of approved epoxy paint - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1950 - 2100 mm |
| 051006(I)Z | Paint pipework including priming with approved primer and one coat of approved epoxy paint - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve >2100 mm |
| 051006(II)I | Paint pipework including priming with approved primer and one coat of approved epoxy paint - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 450 mm |
| 051006(II)J | Paint pipework including priming with approved primer and one coat of approved epoxy paint - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 500 mm |
| 051006(II)K | Paint pipework including priming with approved primer and one coat of approved epoxy paint - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 525 mm |
| 051006(II)L | Paint pipework including priming with approved primer and one coat of approved epoxy paint - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 600 mm |
| 051006(II)M | Paint pipework including priming with approved primer and one coat of approved epoxy paint - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 675 mm |
| 051006(II)N | Paint pipework including priming with approved primer and one coat of approved epoxy paint - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 700 mm |
| 051006(II)O | Paint pipework including priming with approved primer and one coat of approved epoxy paint - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 750 mm |
| 051006(II)P | Paint pipework including priming with approved primer and one coat of approved epoxy paint - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 800 mm |
| 051006(II)Q | Paint pipework including priming with approved primer and one coat of approved epoxy paint - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 900 mm |
| 051006(II)R | Paint pipework including priming with approved primer and one coat of approved epoxy paint - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1000 mm |
| 051006(II)S | Paint pipework including priming with approved primer and one coat of approved epoxy paint - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1050 mm |
| 051006(II)T | Paint pipework including priming with approved primer and one coat of approved epoxy paint - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1100 mm |
| 051006(II)U | Paint pipework including priming with approved primer and one coat of approved epoxy paint - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1200 mm |
| 051006(II)V | Paint pipework including priming with approved primer and one coat of approved epoxy paint - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1350 mm |
| 051006(II)W | Paint pipework including priming with approved primer and one coat of approved epoxy paint - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1400 mm |
| 051006(II)X | Paint pipework including priming with approved primer and one coat of approved epoxy paint - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1800 mm |
| 051006(II)Y | Paint pipework including priming with approved primer and one coat of approved epoxy paint - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1950 - 2100 mm |
| 051006(II)Z | Paint pipework including priming with approved primer and one coat of approved epoxy paint - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve >2100 mm |
| 051007(I)U | Extra over Item No. 051/006 for each extra coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1200 mm |
| 051007(I)V | Extra over Item No. 051/006 for each extra coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1350 mm |
| 051007(I)W | Extra over Item No. 051/006 for each extra coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1400 mm |
| 051007(I)X | Extra over Item No. 051/006 for each extra coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1800 mm |
| 051007(I)Y | Extra over Item No. 051/006 for each extra coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1950 - 2100 mm |
| 051007(I)Z | Extra over Item No. 051/006 for each extra coat - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve >2100 mm |
| 051007(II)U | Extra over Item No. 051/006 for each extra coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1200 mm |
| 051007(II)V | Extra over Item No. 051/006 for each extra coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1350 mm |
| 051007(II)W | Extra over Item No. 051/006 for each extra coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1400 mm |
| 051007(II)X | Extra over Item No. 051/006 for each extra coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1800 mm |
| 051007(II)Y | Extra over Item No. 051/006 for each extra coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1950 - 2100 mm |
| 051007(II)Z | Extra over Item No. 051/006 for each extra coat - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve >2100 mm |
| 051008B | Scrape and rub down old paint work for sluice valve and prepare for painting. By-pass valve measured separately. Nominal diameter of pipe/valve 100 mm |
| 051008C | Scrape and rub down old paint work for sluice valve and prepare for painting. By-pass valve measured separately. Nominal diameter of pipe/valve 125 -150 mm |
| 051008D | Scrape and rub down old paint work for sluice valve and prepare for painting. By-pass valve measured separately. Nominal diameter of pipe/valve 200 mm |
| 051008E | Scrape and rub down old paint work for sluice valve and prepare for painting. By-pass valve measured separately. Nominal diameter of pipe/valve 250 mm |
| 051008F | Scrape and rub down old paint work for sluice valve and prepare for painting. By-pass valve measured separately. Nominal diameter of pipe/valve 300 mm |
| 051008G | Scrape and rub down old paint work for sluice valve and prepare for painting. By-pass valve measured separately. Nominal diameter of pipe/valve 350 -375 mm |
| 051008H | Scrape and rub down old paint work for sluice valve and prepare for painting. By-pass valve measured separately. Nominal diameter of pipe/valve 400 mm |
| 051008I | Scrape and rub down old paint work for sluice valve and prepare for painting. By-pass valve measured separately. Nominal diameter of pipe/valve 450 mm |
| 051008J | Scrape and rub down old paint work for sluice valve and prepare for painting. By-pass valve measured separately. Nominal diameter of pipe/valve 500 mm |
| 051008K | Scrape and rub down old paint work for sluice valve and prepare for painting. By-pass valve measured separately. Nominal diameter of pipe/valve 525 mm |
| 051008L | Scrape and rub down old paint work for sluice valve and prepare for painting. By-pass valve measured separately. Nominal diameter of pipe/valve 600 mm |
| 051008M | Scrape and rub down old paint work for sluice valve and prepare for painting. By-pass valve measured separately. Nominal diameter of pipe/valve 675 mm |
| 051008N | Scrape and rub down old paint work for sluice valve and prepare for painting. By-pass valve measured separately. Nominal diameter of pipe/valve 700 mm |
| 051008O | Scrape and rub down old paint work for sluice valve and prepare for painting. By-pass valve measured separately. Nominal diameter of pipe/valve 750 mm |
| 051008P | Scrape and rub down old paint work for sluice valve and prepare for painting. By-pass valve measured separately. Nominal diameter of pipe/valve 800 mm |
| 051008Q | Scrape and rub down old paint work for sluice valve and prepare for painting. By-pass valve measured separately. Nominal diameter of pipe/valve 900 mm |
| 051008R | Scrape and rub down old paint work for sluice valve and prepare for painting. By-pass valve measured separately. Nominal diameter of pipe/valve 1000 mm |
| 051008S | Scrape and rub down old paint work for sluice valve and prepare for painting. By-pass valve measured separately. Nominal diameter of pipe/valve 1050 mm |
| 051008T | Scrape and rub down old paint work for sluice valve and prepare for painting. By-pass valve measured separately. Nominal diameter of pipe/valve 1100 mm |
| 051008U | Scrape and rub down old paint work for sluice valve and prepare for painting. By-pass valve measured separately. Nominal diameter of pipe/valve 1200 mm |
| 051008V | Scrape and rub down old paint work for sluice valve and prepare for painting. By-pass valve measured separately. Nominal diameter of pipe/valve 1350 mm |
| 051008W | Scrape and rub down old paint work for sluice valve and prepare for painting. By-pass valve measured separately. Nominal diameter of pipe/valve 1400 mm |
| 051008X | Scrape and rub down old paint work for sluice valve and prepare for painting. By-pass valve measured separately. Nominal diameter of pipe/valve 1800 mm |
| 051008Y | Scrape and rub down old paint work for sluice valve and prepare for painting. By-pass valve measured separately. Nominal diameter of pipe/valve 1950 - 2100 mm |
| 051009(I)B | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 100 mm |
| 051009(I)C | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 125 -150 mm |
| 051009(I)D | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 200 mm |
| 051009(I)E | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 250 mm |
| 051009(I)F | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 300 mm |
| 051009(I)G | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 350 -375 mm |
| 051009(I)H | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 400 mm |
| 051009(I)I | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 450 mm |
| 051009(I)J | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 500 mm |
| 051009(I)K | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 525 mm |
| 051009(I)L | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 600 mm |
| 051009(I)M | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 675 mm |
| 051009(I)N | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 700 mm |
| 051009(I)O | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 750 mm |
| 051009(I)P | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 800 mm |
| 051009(I)Q | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 900 mm |
| 051009(I)R | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1000 mm |
| 051009(I)S | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1050 mm |
| 051009(I)T | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1100 mm |
| 051009(I)U | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1200 mm |
| 051009(I)V | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1350 mm |
| 051009(I)W | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1400 mm |
| 051009(I)X | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1800 mm |
| 051009(I)Y | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1950 - 2100 mm |
| 051009(II)B | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 100 mm |
| 051009(II)C | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 125 -150 mm |
| 051009(II)D | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 200 mm |
| 051009(II)E | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 250 mm |
| 051009(II)F | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 300 mm |
| 051009(II)G | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 350 -375 mm |
| 051009(II)H | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 400 mm |
| 051009(II)I | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 450 mm |
| 051009(II)J | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 500 mm |
| 051009(II)K | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 525 mm |
| 051009(II)L | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 600 mm |
| 051009(II)M | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 675 mm |
| 051009(II)N | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 700 mm |
| 051009(II)O | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 750 mm |
| 051009(II)P | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 800 mm |
| 051009(II)Q | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 900 mm |
| 051009(II)R | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1000 mm |
| 051009(II)S | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1050 mm |
| 051009(II)T | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1100 mm |
| 051009(II)U | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1200 mm |
| 051009(II)V | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1350 mm |
| 051009(II)W | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1400 mm |
| 051009(II)X | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1800 mm |
| 051009(II)Y | Paint sluice valve including priming with an approved primer, and one coat of approved paint. By-pass valve measured separately - paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1950 - 2100 mm |
| 051010(I)B | Extra over Item No. 051/009 for each additional coat- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 100 mm |
| 051010(I)C | Extra over Item No. 051/009 for each additional coat- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 125 -150 mm |
| 051010(I)D | Extra over Item No. 051/009 for each additional coat- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 200 mm |
| 051010(I)E | Extra over Item No. 051/009 for each additional coat- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 250 mm |
| 051010(I)F | Extra over Item No. 051/009 for each additional coat- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 300 mm |
| 051010(I)G | Extra over Item No. 051/009 for each additional coat- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 350 -375 mm |
| 051010(I)H | Extra over Item No. 051/009 for each additional coat- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 400 mm |
| 051010(I)I | Extra over Item No. 051/009 for each additional coat- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 450 mm |
| 051010(I)J | Extra over Item No. 051/009 for each additional coat- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 500 mm |
| 051010(I)K | Extra over Item No. 051/009 for each additional coat- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 525 mm |
| 051010(I)L | Extra over Item No. 051/009 for each additional coat- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 600 mm |
| 051010(I)M | Extra over Item No. 051/009 for each additional coat- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 675 mm |
| 051010(I)N | Extra over Item No. 051/009 for each additional coat- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 700 mm |
| 051010(I)O | Extra over Item No. 051/009 for each additional coat- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 750 mm |
| 051010(I)P | Extra over Item No. 051/009 for each additional coat- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 800 mm |
| 051010(I)Q | Extra over Item No. 051/009 for each additional coat- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 900 mm |
| 051010(I)R | Extra over Item No. 051/009 for each additional coat- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1000 mm |
| 051010(I)S | Extra over Item No. 051/009 for each additional coat- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1050 mm |
| 051010(I)T | Extra over Item No. 051/009 for each additional coat- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1100 mm |
| 051010(I)U | Extra over Item No. 051/009 for each additional coat- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1200 mm |
| 051010(II)B | Extra over Item No. 051/009 for each additional coat- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 100 mm |
| 051010(II)C | Extra over Item No. 051/009 for each additional coat- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 125 -150 mm |
| 051010(II)D | Extra over Item No. 051/009 for each additional coat- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 200 mm |
| 051010(II)E | Extra over Item No. 051/009 for each additional coat- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 250 mm |
| 051010(II)F | Extra over Item No. 051/009 for each additional coat- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 300 mm |
| 051010(II)G | Extra over Item No. 051/009 for each additional coat- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 350 -375 mm |
| 051010(II)H | Extra over Item No. 051/009 for each additional coat- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 400 mm |
| 051010(II)I | Extra over Item No. 051/009 for each additional coat- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 450 mm |
| 051010(II)J | Extra over Item No. 051/009 for each additional coat- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 500 mm |
| 051010(II)K | Extra over Item No. 051/009 for each additional coat- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 525 mm |
| 051010(II)L | Extra over Item No. 051/009 for each additional coat- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 600 mm |
| 051010(II)M | Extra over Item No. 051/009 for each additional coat- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 675 mm |
| 051010(II)N | Extra over Item No. 051/009 for each additional coat- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 700 mm |
| 051010(II)O | Extra over Item No. 051/009 for each additional coat- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 750 mm |
| 051010(II)P | Extra over Item No. 051/009 for each additional coat- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 800 mm |
| 051010(II)Q | Extra over Item No. 051/009 for each additional coat- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 900 mm |
| 051010(II)R | Extra over Item No. 051/009 for each additional coat- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1000 mm |
| 051010(II)S | Extra over Item No. 051/009 for each additional coat- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1050 mm |
| 051010(II)T | Extra over Item No. 051/009 for each additional coat- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1100 mm |
| 051010(II)U | Extra over Item No. 051/009 for each additional coat- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1200 mm |
| 051011(I)B | Paint sluice valve with one coat of approved bitumen. By-pass valve measured separately- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 100 mm |
| 051011(I)C | Paint sluice valve with one coat of approved bitumen. By-pass valve measured separately- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 125 -150 mm |
| 051011(I)D | Paint sluice valve with one coat of approved bitumen. By-pass valve measured separately- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 200 mm |
| 051011(I)E | Paint sluice valve with one coat of approved bitumen. By-pass valve measured separately- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 250 mm |
| 051011(I)F | Paint sluice valve with one coat of approved bitumen. By-pass valve measured separately- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 300 mm |
| 051011(I)G | Paint sluice valve with one coat of approved bitumen. By-pass valve measured separately- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 350 -375 mm |
| 051011(I)H | Paint sluice valve with one coat of approved bitumen. By-pass valve measured separately- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 400 mm |
| 051011(I)I | Paint sluice valve with one coat of approved bitumen. By-pass valve measured separately- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 450 mm |
| 051011(I)J | Paint sluice valve with one coat of approved bitumen. By-pass valve measured separately- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 500 mm |
| 051011(I)K | Paint sluice valve with one coat of approved bitumen. By-pass valve measured separately- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 525 mm |
| 051011(I)L | Paint sluice valve with one coat of approved bitumen. By-pass valve measured separately- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 600 mm |
| 051011(I)M | Paint sluice valve with one coat of approved bitumen. By-pass valve measured separately- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 675 mm |
| 051011(I)N | Paint sluice valve with one coat of approved bitumen. By-pass valve measured separately- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 700 mm |
| 051011(I)O | Paint sluice valve with one coat of approved bitumen. By-pass valve measured separately- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 750 mm |
| 051011(I)P | Paint sluice valve with one coat of approved bitumen. By-pass valve measured separately- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 800 mm |
| 051011(I)Q | Paint sluice valve with one coat of approved bitumen. By-pass valve measured separately- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 900 mm |
| 051011(I)R | Paint sluice valve with one coat of approved bitumen. By-pass valve measured separately- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1000 mm |
| 051011(I)S | Paint sluice valve with one coat of approved bitumen. By-pass valve measured separately- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1050 mm |
| 051011(I)T | Paint sluice valve with one coat of approved bitumen. By-pass valve measured separately- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1100 mm |
| 051011(I)U | Paint sluice valve with one coat of approved bitumen. By-pass valve measured separately- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1200 mm |
| 051011(II)B | Paint sluice valve with one coat of approved bitumen. By-pass valve measured separately- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 100 mm |
| 051011(II)C | Paint sluice valve with one coat of approved bitumen. By-pass valve measured separately- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 125 -150 mm |
| 051011(II)D | Paint sluice valve with one coat of approved bitumen. By-pass valve measured separately- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 200 mm |
| 051011(II)E | Paint sluice valve with one coat of approved bitumen. By-pass valve measured separately- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 250 mm |
| 051011(II)F | Paint sluice valve with one coat of approved bitumen. By-pass valve measured separately- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 300 mm |
| 051011(II)G | Paint sluice valve with one coat of approved bitumen. By-pass valve measured separately- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 350 -375 mm |
| 051011(II)H | Paint sluice valve with one coat of approved bitumen. By-pass valve measured separately- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 400 mm |
| 051011(II)I | Paint sluice valve with one coat of approved bitumen. By-pass valve measured separately- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 450 mm |
| 051011(II)J | Paint sluice valve with one coat of approved bitumen. By-pass valve measured separately- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 500 mm |
| 051011(II)K | Paint sluice valve with one coat of approved bitumen. By-pass valve measured separately- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 525 mm |
| 051011(II)L | Paint sluice valve with one coat of approved bitumen. By-pass valve measured separately- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 600 mm |
| 051011(II)M | Paint sluice valve with one coat of approved bitumen. By-pass valve measured separately- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 675 mm |
| 051011(II)N | Paint sluice valve with one coat of approved bitumen. By-pass valve measured separately- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 700 mm |
| 051011(II)O | Paint sluice valve with one coat of approved bitumen. By-pass valve measured separately- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 750 mm |
| 051011(II)P | Paint sluice valve with one coat of approved bitumen. By-pass valve measured separately- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 800 mm |
| 051011(II)Q | Paint sluice valve with one coat of approved bitumen. By-pass valve measured separately- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 900 mm |
| 051011(II)R | Paint sluice valve with one coat of approved bitumen. By-pass valve measured separately- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1000 mm |
| 051011(II)S | Paint sluice valve with one coat of approved bitumen. By-pass valve measured separately- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1050 mm |
| 051011(II)T | Paint sluice valve with one coat of approved bitumen. By-pass valve measured separately- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1100 mm |
| 051011(II)U | Paint sluice valve with one coat of approved bitumen. By-pass valve measured separately- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1200 mm |
| 051012(I)B | Extra over Item No. 051/011 for each additional coat of bitumen- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 100 mm |
| 051012(I)C | Extra over Item No. 051/011 for each additional coat of bitumen- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 125 -150 mm |
| 051012(I)D | Extra over Item No. 051/011 for each additional coat of bitumen- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 200 mm |
| 051012(I)E | Extra over Item No. 051/011 for each additional coat of bitumen- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 250 mm |
| 051012(I)F | Extra over Item No. 051/011 for each additional coat of bitumen- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 300 mm |
| 051012(I)G | Extra over Item No. 051/011 for each additional coat of bitumen- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 350 -375 mm |
| 051012(I)H | Extra over Item No. 051/011 for each additional coat of bitumen- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 400 mm |
| 051012(I)I | Extra over Item No. 051/011 for each additional coat of bitumen- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 450 mm |
| 051012(I)J | Extra over Item No. 051/011 for each additional coat of bitumen- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 500 mm |
| 051012(I)K | Extra over Item No. 051/011 for each additional coat of bitumen- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 525 mm |
| 051012(I)L | Extra over Item No. 051/011 for each additional coat of bitumen- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 600 mm |
| 051012(I)M | Extra over Item No. 051/011 for each additional coat of bitumen- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 675 mm |
| 051012(I)N | Extra over Item No. 051/011 for each additional coat of bitumen- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 700 mm |
| 051012(I)O | Extra over Item No. 051/011 for each additional coat of bitumen- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 750 mm |
| 051012(I)P | Extra over Item No. 051/011 for each additional coat of bitumen- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 800 mm |
| 051012(I)Q | Extra over Item No. 051/011 for each additional coat of bitumen- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 900 mm |
| 051012(I)R | Extra over Item No. 051/011 for each additional coat of bitumen- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1000 mm |
| 051012(I)S | Extra over Item No. 051/011 for each additional coat of bitumen- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1050 mm |
| 051012(I)T | Extra over Item No. 051/011 for each additional coat of bitumen- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1100 mm |
| 051012(I)U | Extra over Item No. 051/011 for each additional coat of bitumen- paint or bitumen provided by the Contractor. Nominal diameter of pipe/valve 1200 mm |
| 051012(II)B | Extra over Item No. 051/011 for each additional coat of bitumen- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 100 mm |
| 051012(II)C | Extra over Item No. 051/011 for each additional coat of bitumen- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 125 -150 mm |
| 051012(II)D | Extra over Item No. 051/011 for each additional coat of bitumen- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 200 mm |
| 051012(II)E | Extra over Item No. 051/011 for each additional coat of bitumen- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 250 mm |
| 051012(II)F | Extra over Item No. 051/011 for each additional coat of bitumen- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 300 mm |
| 051012(II)G | Extra over Item No. 051/011 for each additional coat of bitumen- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 350 -375 mm |
| 051012(II)H | Extra over Item No. 051/011 for each additional coat of bitumen- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 400 mm |
| 051012(II)I | Extra over Item No. 051/011 for each additional coat of bitumen- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 450 mm |
| 051012(II)J | Extra over Item No. 051/011 for each additional coat of bitumen- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 500 mm |
| 051012(II)K | Extra over Item No. 051/011 for each additional coat of bitumen- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 525 mm |
| 051012(II)L | Extra over Item No. 051/011 for each additional coat of bitumen- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 600 mm |
| 051012(II)M | Extra over Item No. 051/011 for each additional coat of bitumen- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 675 mm |
| 051012(II)N | Extra over Item No. 051/011 for each additional coat of bitumen- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 700 mm |
| 051012(II)O | Extra over Item No. 051/011 for each additional coat of bitumen- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 750 mm |
| 051012(II)P | Extra over Item No. 051/011 for each additional coat of bitumen- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 800 mm |
| 051012(II)Q | Extra over Item No. 051/011 for each additional coat of bitumen- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 900 mm |
| 051012(II)R | Extra over Item No. 051/011 for each additional coat of bitumen- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1000 mm |
| 051012(II)S | Extra over Item No. 051/011 for each additional coat of bitumen- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1050 mm |
| 051012(II)T | Extra over Item No. 051/011 for each additional coat of bitumen- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1100 mm |
| 051012(II)U | Extra over Item No. 051/011 for each additional coat of bitumen- paint or bitumen provided by the Employer. Nominal diameter of pipe/valve 1200 mm |
| 052001 | Remove paint from woodwork and prepare for repainting. |
| 052002 | Remove flaked paintwork for additional coat of paint. |
| 052003 | Remove whitewashed/distempered walls and ceiling for re-painting. |
| 052004 | Brush surface for painting. |
| 052005A | Waterproof cement paint on surfaces. 1 coat |
| 052005B | Waterproof cement paint on surfaces. 2 coats |
| 052006A | Waterproof cement paint on unplastered brick concrete surfaces. 1 coat |
| 052006B | Waterproof cement paint on unplastered brick concrete surfaces. 2 coats |
| 052007A | Plastic emulsion paint on plastered surfaces. 1 coat |
| 052007B | Plastic emulsion paint on plastered surfaces. 2 coats |
| 052008A | Plastic emulsion paint on unplastered surfaces. 1 coat |
| 052008B | Plastic emulsion paint on unplastered surfaces. 2 coats |
| 052009A | Bituminous paint to metal works. 1 coat |
| 052009B | Bituminous paint to metal works. 2 coats |
| 052010A | As Item No. 052/009 but in small patches not exceeding 0.21 m2 each. 1 coat |
| 052010B | As Item No. 052/009 but in small patches not exceeding 0.21 m2 each. 2 coats |
| 052011A | Bituminous compound to pipes, reservoirs, walls, etc. 1 coat |
| 052011B | Bituminous compound to pipes, reservoirs, walls, etc. 2 coats |
| 052012A | As Item No. 052/011, but for bituminous compound provided by the Employer. 1 coat |
| 052012B | As Item No. 052/011, but for bituminous compound provided by the Employer. 2 coats |
| 052013A | Good Year Black Coating' or equivalent to water tank. 1 coat |
| 052013B | Good Year Black Coating' or equivalent to water tank. 2 coats |
| 052014A | Sandtex' paint or approved equivalent to walls etc. 1 coat |
| 052014B | Sandtex' paint or approved equivalent to walls etc. 2 coats |
| 052015 | 1 coat of approved epoxy paint to the internal surfaces of water or liquid-retaining structures. |
| 052015a | 2 coats of approved epoxy paint to the steelworks of water or liquid-retaining structures. |
| 052016 | Protective coatings, including pretreatment, primer, undercoat and finish coat, to structural steel framework to salt water service reservoir roof decking in accordance with Particular Specification clause 18.04. |
| 052016a | 1 coat of Groman-nano GN8254 penetrating wall primer and 2 coats of Groman-nano GN8293 super HG exterior wall nano coating system or approved products having equivalent functions and performance on external walls or surfaces. |
| 052016b | 2 coats of water-based acrylic copolymer enamel finish to concrete or metal surface. |
| 052016c | 2 coats of zero volatile organic compound water-based acrylic copolymer enamel finish to concrete or metal surface. |
| 052017A | 2 coats of paint for block letters or figures on signboards, measuring scales etc. Height of letter or character not exceeding (mm) 25 |
| 052017B | 2 coats of paint for block letters or figures on signboards, measuring scales etc. Height of letter or character not exceeding (mm) 50 |
| 052017C | 2 coats of paint for block letters or figures on signboards, measuring scales etc. Height of letter or character not exceeding (mm) 100 |
| 052017D | 2 coats of paint for block letters or figures on signboards, measuring scales etc. Height of letter or character not exceeding (mm) 150 |
| 052017E | 2 coats of paint for block letters or figures on signboards, measuring scales etc. Height of letter or character not exceeding (mm) 225 |
| 052017F | 2 coats of paint for block letters or figures on signboards, measuring scales etc. Height of letter or character not exceeding (mm) 300 |
| 052018A | 2 coats of paint for Chinese characters on signboards, measuring scales etc. Height of letter or character not exceeding (mm) 25 |
| 052018B | 2 coats of paint for Chinese characters on signboards, measuring scales etc. Height of letter or character not exceeding (mm) 50 |
| 052018C | 2 coats of paint for Chinese characters on signboards, measuring scales etc. Height of letter or character not exceeding (mm) 100 |
| 052018D | 2 coats of paint for Chinese characters on signboards, measuring scales etc. Height of letter or character not exceeding (mm) 150 |
| 052018E | 2 coats of paint for Chinese characters on signboards, measuring scales etc. Height of letter or character not exceeding (mm) 225 |
| 052018F | 2 coats of paint for Chinese characters on signboards, measuring scales etc. Height of letter or character not exceeding (mm) 300 |
| 052019A | As Item No. 052/017, but for small letters. Height of letter or character not exceeding (mm) 25 |
| 052019B | As Item No. 052/017, but for small letters. Height of letter or character not exceeding (mm) 50 |
| 052019C | As Item No. 052/017, but for small letters. Height of letter or character not exceeding (mm) 100 |
| 052019D | As Item No. 052/017, but for small letters. Height of letter or character not exceeding (mm) 150 |
| 052019E | As Item No. 052/017, but for small letters. Height of letter or character not exceeding (mm) 225 |
| 052019F | As Item No. 052/017, but for small letters. Height of letter or character not exceeding (mm) 300 |
| 052020 | Repaint portable sign board (1,220 mm x 800 mm) as detailed on Drawing No. SK 2953/6. |
| 052021 | Paint valve position indicators as shown on Drawing No. W7162/1 and Drawing No. SK 3603/1 on vertical faces. |
| 052022A | Paint ref. A to C, E to H and L to wood, iron, steel, plaster, concrete, etc. First coat |
| 052022B | Paint ref. A to C, E to H and L to wood, iron, steel, plaster, concrete, etc. Each extra coat |
| 052022C | Paint ref. A to C, E to H and L to wood, iron, steel, plaster, concrete, etc. Finishing coat |
| 052023A | Paint ref. E, F and H to gates, fencing, gratings, guard bars, etc. First coat |
| 052023B | Paint ref. E, F and H to gates, fencing, gratings, guard bars, etc. Each extra coat |
| 052023C | Paint ref. E, F and H to gates, fencing, gratings, guard bars, etc. Finishing coat |
| 052024A | Paint ref. B, C, E and F to doors and door frames complete. First coat |
| 052024B | Paint ref. B, C, E and F to doors and door frames complete. Each extra coat |
| 052024C | Paint ref. B, C, E and F to doors and door frames complete. Finishing coat |
| 052025A | Paint ref. C, E and F to windows and frames. First coat |
| 052025B | Paint ref. C, E and F to windows and frames. Each extra coat |
| 052025C | Paint ref. C, E and F to windows and frames. Finishing coat |
| 052026A | Paint ref. H to chains, iron and other bars, straps to roofs etc. First coat |
| 052026B | Paint ref. H to chains, iron and other bars, straps to roofs etc. Each extra coat |
| 052026C | Paint ref. H to chains, iron and other bars, straps to roofs etc. Finishing coat |
| 052027 | Remove paint from chains, iron and other bars, straps to roofs etc. |
| 060011 | Installation of 15 mm diameter water meters in position. |
| 060011a | Extra over items no. 060/011 for installation of water meters located in remote area. |
| 060012 | As item no. 060/011, but for a batch of meters in the same estate or same village or no more than eight adjoining or adjacent buildings, the total number of meters exceeding 20 but not exceeding 50. |
| 060013 | As item no. 060/012, but for the total number of meters exceeding 50 but not exceeding 100. |
| 060014 | As item no. 060/012, but for the total number of meters exceeding 100 but not exceeding 500. |
| 060015 | As item no. 060/012, but for the total number of meters exceeding 500. |
| 060016 | Installation of 25 mm diameter water meters in position. |
| 060016a | Installation of 40 mm diameter water meters in position. |
| 060016b | Installation of 50 mm diameter water meters in position. |
| 060017 | Installation of 80 mm diameter water meters in position. |
| 060018 | Installation of 100 mm diameter water meters in position. |
| 060019 | Installation of 150 mm diameter water meters in position. |
| 060020 | Installation of 200 mm diameter water meters in position. |
| 060021 | Installation of 250 mm diameter water meters in position. |
| 060022 | Installation of 300 mm diameter water meters in position. |
| 060023 | Installation of 400 mm diameter water meters in position. |
| 060024 | Extra over items nos. 060/011 to 060/015 for execution of the work outside normal working hours. |
| 060024a | Extra over items no. 060/011 and 060/016 to 060/023 for provision of extra measures at site to facilitate installation of water meters. |
| 060024b | Extra over items no. 060/011 and 060/016 to 060/023 for supply and installation of pipeworks and accessories for pressure tapping point. |
| 060025 | Extra over item no. 060/016 for execution of the work outside normal working hours. |
| 060025a | Extra over item no. 060/016a for execution of the work outside normal working hours. |
| 060025b | Extra over item no. 060/016b for execution of the work outside normal working hours. |
| 060026 | Extra over item no. 060/017 for execution of the work outside normal working hours. |
| 060027 | Extra over item no. 060/018 for execution of the work outside normal working hours. |
| 060028 | Extra over item no. 060/019 for execution of the work outside normal working hours. |
| 060029 | Extra over item no. 060/020 for execution of the work outside normal working hours. |
| 060030 | Extra over item no. 060/021 for execution of the work outside normal working hours. |
| 060031 | Extra over item no. 060/022 for execution of the work outside normal working hours. |
| 060032 | Extra over item no. 060/023 for execution of the work outside normal working hours. |
| 060032a | Submission of unsuccessful water meter installation report and associated works, the total number of water meters installed unsuccessfully exceeding 0 but not exceeding 20. |
| 060032b | Extra over item no. 060/032a for each additional 20 numbers of water meters installed unsuccessfully or part thereof in excess of 20 numbers. |
| 061001 | Removal of 15 mm diameter water meters. |
| 061002 | As item no. 061/001, but for a batch of meters in the same estate or same village or no more than eight adjoining or adjacent buildings, the total number of meters exceeding 10 but not exceeding 50. |
| 061003 | As item no. 061/002, but for the total number of meters exceeding 50 but not exceeding 100. |
| 061004 | As item no. 061/002, but for the total number of meters exceeding 100 but not exceeding 500. |
| 061005 | As item no. 061/002, but for the total number of meters exceeding 500 but not exceeding 1,000. |
| 061006 | Removal of 25 mm to 50 mm diameter water meters. |
| 061007 | Removal of 80 mm diameter water meters. |
| 061008 | Removal of 100 mm diameter water meters. |
| 061009 | Removal of 150 mm diameter water meters. |
| 061010 | Removal of 200 mm diameter water meters. |
| 061011 | Removal of 250 mm diameter water meters. |
| 061012 | Removal of 300 mm diameter water meters. |
| 061013 | Removal of 400 mm diameter water meters. |
| 061014 | Abortive works for unsuccessful removal of 15mm diameter water meters. |
| 061015 | Abortive works for unsuccessful removal of 25 mm to 50 mm diameter water meters. |
| 061016 | Abortive works for unsuccessful removal of 80 mm diameter water meters. |
| 061017 | Abortive works for unsuccessful removal of 100 mm to 200 mm diameter water meters. |
| 061018 | Abortive works for unsuccessful removal of 250 mm to 300 mm diameter water meters. |
| 061019 | Abortive works for unsuccessful removal of 400 mm diameter water meters. |
| 061020 | Plumbing works at water meter position Supply and replacement of Loose Jumper Type Stopclock for 15 mm diameter water meter |
| 061021 | Plumbing works at water meter position Supply and replacement of Loose Jumper Type Stopclock for 25 mm diameter water meter |
| 061022 | Plumbing works at water meter position Supply and replacement of Loose Jumper Type Stopclock for 40 mm diameter water meter |
| 061023 | Plumbing works at water meter position Supply and replacement of pipe works, length not exceeding one metre at a water meter position for 15 mm diameter water meter |
| 061024 | Plumbing works at water meter position Supply and replacement of pipe works, length not exceeding one metre at a water meter position for 25 mm diameter water meter |
| 061025 | Plumbing works at water meter position Supply and replacement of pipe works, length not exceeding one metre at a water meter position for 40 mm diameter water meter |
| 061026 | Plumbing works at water meter position Supply and installation of fresh water supply pipes including all fittings to existing premises to form a new meter position as instructed and accepted by the Engineer. for 15 mm diameter water meter |
| 061027 | Plumbing works at water meter position Supply and installation of fresh water supply pipes including all fittings to existing premises to form a new meter position as instructed and accepted by the Engineer. for 25 mm diameter water meter |
| 061028 | Plumbing works at water meter position Supply and installation of fresh water supply pipes including all fittings to existing premises to form a new meter position as instructed and accepted by the Engineer. for 40 mm diameter water meter |
| 062001 | Inspection to inside service. |
| 062002 | Abortive works for unsuccessful inspection to inside service. |
| 063001 | Flow measurement by portable clamp-on type ultrasonic flow meter |
| 070001 | Convey sand, aggregate and spoil for a distance up to 2 km. |
| 070002 | Extra over Item No. 070/001 for each additional 1 km of conveyance or part thereof in excess of 2 km. |
| 070003 | Convey timber, cement, chemicals and miscellaneous building materials excluding sand and aggregate for a distance up to 2 km. |
| 070004 | Convey pipes, valves, specials, metal works, mechanical stores and equipment for a distance up to 2 km. |
| 070005 | Extra over Item No. 070/004 for each article with a total weight exceeding 50 kg but not exceeding 250 kg. |
| 070006 | Extra over Item No. 070/004 for each article with a total weight exceeding 250 kg but not exceeding 1 tonne. |
| 070007 | Extra over Item No. 070/004 for each article with a total weight in excess of 1 tonne. |
| 070008 | Extra over Item Nos. 070/003 and 070/004 for each additional 1 km of conveyance or part thereof in excess of 2 km. |
| 070009 | Extra over Item Nos. 070/001, 070/003 and 070/004 for each round trip across the harbour with a normal lorry load. |
| 070010 | Extra over Item Nos. 070/001 and 070/003 for each round trip across the harbour where load overhangs by 1.2 m or more. |
| 070011 | Extra over Item No. 070/003 for conveyance of chlorine or other toxic chemicals. |
| 070012 | Convey pipes, valves, specials, metal works, mechanical stores and equipment for each additional 180 m or part thereof in excess of 45 m. |
| 070013 | Convey spoil for each additional 180 m or part thereof in excess of 45 m. |
| 070014 | Convey materials or stores not covered by Item Nos. 070/012 and 070/013. |
| 070015 | Extra over Item No. 070/012 for each article exceeding 50 kg but not exceeding 250 kg in total weight. |
| 070016 | Extra over Item No. 070/012 for each article exceeding 250 kg in total weight. |
| 070017 | Extra over Item No. 070/012 for each rise in elevation of 30 m or part of 30 m in excess of an initial 30 m. |
| 070018 | Extra over Item No. 070/013 for each rise in elevation of 30 m or part of 30 m in excess of an initial 30 m. |
| 070019 | Extra over Item No. 070/014 for each rise in elevation of 30 m or part of 30 m in excess of an initial 30 m. |
| 070020 | Extra over Item No. 070/014 for conveyance of chlorine or other toxic chemicals. |
| 070021 | Convey by barge, junk or lighter, materials for concrete work including cement, aggregates, reinforcing bars, water and formwork, up to 4 km. |
| 070022 | Extra over Item No. 070/021 for each additional 2 km or part thereof in excess of 4 km. |
| 070023 | Convey by barge, junk or lighter, pipes, valves, pipe specials, metal works, mechanical stores and equipment up to 4 km. |
| 070024 | Convey by barge, junk or lighter, sludge, materials or stores not covered by Item Nos. 070/021 and 070/023 up to 4 km. |
| 070025 | Extra over Item Nos. 070/023 and 070/024 for each additional 2 km or part thereof in excess of 4 km. |
| 070026 | Extra over Item No. 070/021 when no pier or wharf is available at off-loading point. |
| 070027 | Extra over Item No. 070/023 when no pier or wharf is available at off-loading point. |
| 070028 | Extra over Item No. 070/024 when no pier or wharf is available at off-loading point. |
| 070029 | Extra over Item No. 070/024 for conveyance of chlorine or other toxic chemicals. |
| 070030 | Dispose sludge from treatment works, catchwater, tunnel, tunnel portal and the like and deliver to sewage treatment works or sludge disposal site. |
| 070031 | Dispose sludge cakes from treatment works, catchwater, tunnel, tunnel portal and the like and deliver to sludge disposal site. |
| 070032 | Extra over Item No. 070/031 for loading the sludge cakes fallen to the floor or into container instead of the tanker vehicle. |
| 070033 | Dispose chemical waste from treatment works, catchwater, tunnel, tunnel portal and the like and deliver to chemical waste disposal sites up to a distance of 2 km. |
| 070034 | Extra over Item No. 070/033 for each additional 1 km of conveyance or part thereof in excess of 2 km. |
| 080001 | Granular sub-base. |
| 080002 | Lean concrete roadbase. |
| 080003 | Bituminous roadbase. |
| 080004 | Bituminous regulating course. |
| 080005 | Fine cold asphalt regulating course. |
| 081001 | Establishment of paving machine. |
| 081001a | Establishment of paving machine outside normal working hours |
| 081002 | 37.5 mm nominal size bituminous base course. |
| 081003 | 28 mm nominal size bituminous base course. |
| 081004 | Bituminous wearing course. |
| 081005 | Fine cold asphalt. |
| 081006 | 10mm nominal size stone mastic asphalt (Grade 60-70 bitumen). |
| 081006a | 10mm nominal size stone mastic asphalt (polymer modified bitumen). |
| 081007 | 20mm nominal size stone mastic asphalt (Grade 60-70mm bitumen). |
| 081007a | Cushion course |
| 081008 | Polymer modified friction course. |
| 081009 | Porous friction course. |
| 081010 | Anti-skid surface dressing on flexible bituminous surfacing and concrete carriageway. |
| 081011 | Reinstatement of small areas for flexible surfacing Area not exceeding 2.0 m2. |
| 081012 | Reinstatement of small areas for flexible surfacing Area exceeding 2.0 m2 but not exceeding 4.0 m2. |
| 081013 | Coring of bituminous pavement 150 mm diameter core, depth not exceeding 70 mm. |
| 081014 | Coring of bituminous pavement Extra over Item No. 081/013 for each additional 10 mm of depth or part thereof in excess of 70 mm. |
| 081015 | Cold applied bitumen and resin bound aggregates, such as "Instant Fill" or products having equivalent functions and performance as approved by the Engineer for emergency road reinstatement. |
| 082001A | Concrete pavement of road slab, 100 mm thickness. Grade 40/20D |
| 082001B | Concrete pavement of road slab, 100 mm thickness. Grade 30/20D |
| 082001C | Concrete pavement of road slab, 100 mm thickness. Grade 30/20S |
| 082001D | Concrete pavement of road slab, 100 mm thickness. Grade 20/40S |
| 082001E | Concrete pavement of road slab, 100 mm thickness. Grade 20/20S |
| 082001F | Concrete pavement of road slab, 100 mm thickness. Grade 10/40S |
| 082001G | Concrete pavement of road slab, 100 mm thickness. Grade 10/20S |
| 082002A | Extra over Item No. 082/001 for each additional 25 mm of thickness or part thereof in excess of 100 mm. Grade 40/20D |
| 082002B | Extra over Item No. 082/001 for each additional 25 mm of thickness or part thereof in excess of 100 mm. Grade 30/20D |
| 082002C | Extra over Item No. 082/001 for each additional 25 mm of thickness or part thereof in excess of 100 mm. Grade 30/20S |
| 082002D | Extra over Item No. 082/001 for each additional 25 mm of thickness or part thereof in excess of 100 mm. Grade 20/40S |
| 082002E | Extra over Item No. 082/001 for each additional 25 mm of thickness or part thereof in excess of 100 mm. Grade 20/20S |
| 082002F | Extra over Item No. 082/001 for each additional 25 mm of thickness or part thereof in excess of 100 mm. Grade 10/40S |
| 082002G | Extra over Item No. 082/001 for each additional 25 mm of thickness or part thereof in excess of 100 mm. Grade 10/20S |
| 082003 | Extra over Item Nos. 082/001 to 082/002 for rapid hardening concrete. |
| 082004 | Expansion joint Thickness of slab not exceeding 185 mm. |
| 082005 | Expansion joint Thickness of slab exceeding 185 mm but not exceeding 235 mm. |
| 082006 | Expansion joint Thickness of slab exceeding 235 mm but not exceeding 310 mm. |
| 082007 | Longitudinal joint Slab of any thickness. |
| 082008 | Contraction joint Thickness of slab not exceeding 185 mm. |
| 082009 | Contraction joint Thickness of slab exceeding 185 mm but not exceeding 235 mm. |
| 082010 | Contraction joint Thickness of slab exceeding 235 mm but not exceeding 310 mm. |
| 082011 | Fibrous joint filler 10 mm thick. |
| 082012 | Fibrous joint filler 25 mm thick. |
| 082013 | Joint sealing groove Saw cut grooves in concrete pavement for joint sealant Width of groove (mm) Exceeding -- Not exceeding 10 Depth of groove (mm) Exceeding -- Not exceeding 15 |
| 082014 | Joint sealing groove Saw cut grooves in concrete pavement for joint sealant Width of groove (mm) Exceeding -- Not exceeding 10 Depth of groove (mm) Exceeding 15 Not exceeding 25 |
| 082015 | Joint sealing groove Saw cut grooves in concrete pavement for joint sealant Width of groove (mm) Exceeding 10 Not exceeding 15 Depth of groove (mm) Exceeding -- Not exceeding 15 |
| 082016 | Joint sealing groove Saw cut grooves in concrete pavement for joint sealant Width of groove (mm) Exceeding 10 Not exceeding 15 Depth of groove (mm) Exceeding 15 Not exceeding 20 |
| 082017 | Joint sealing groove Saw cut grooves in concrete pavement for joint sealant Width of groove (mm) Exceeding 10 Not exceeding 15 Depth of groove (mm) Exceeding 20 Not exceeding 25 |
| 082018 | Joint sealing groove Saw cut grooves in concrete pavement for joint sealant Width of groove (mm) Exceeding 15 Not exceeding 20 Depth of groove (mm) Exceeding -- Not exceeding 20 |
| 082019 | Joint sealing groove Saw cut grooves in concrete pavement for joint sealant Width of groove (mm) Exceeding 15 Not exceeding 20 Depth of groove (mm) Exceeding 20 Not exceeding 35 |
| 082020 | Joint sealing groove Saw cut grooves in concrete pavement for joint sealant Width of groove (mm) Exceeding 20 Not exceeding 25 Depth of groove (mm) Exceeding -- Not exceeding 20 |
| 082021 | Joint sealing groove Saw cut grooves in concrete pavement for joint sealant Width of groove (mm) Exceeding 20 Not exceeding 25 Depth of groove (mm) Exceeding 20 Not exceeding 40 |
| 082022 | Joint sealing groove Saw cut grooves in concrete pavement for joint sealant Width of groove (mm) Exceeding 25 Not exceeding 30 Depth of groove (mm) Exceeding -- Not exceeding 25 |
| 082023 | Joint sealing groove Saw cut grooves in concrete pavement for joint sealant Width of groove (mm) Exceeding 25 Not exceeding 30 Depth of groove (mm) Exceeding 25 Not exceeding 30 |
| 082024 | Joint sealing groove Saw cut grooves in concrete pavement for joint sealant Width of groove (mm) Exceeding 30 Not exceeding 35 Depth of groove (mm) Exceeding -- Not exceeding 25 |
| 082025 | Joint sealing groove Saw cut grooves in concrete pavement for joint sealant Width of groove (mm) Exceeding 30 Not exceeding 35 Depth of groove (mm) Exceeding 25 Not exceeding 30 |
| 082026 | Joint sealing groove Saw cut grooves in concrete pavement for joint sealant Width of groove (mm) Exceeding 35 Not exceeding 40 Depth of groove (mm) Exceeding -- Not exceeding 30 |
| 082027 | Joint sealing groove Saw cut grooves in concrete pavement for joint sealant Width of groove (mm) Exceeding 35 Not exceeding 40 Depth of groove (mm) Exceeding 30 Not exceeding 35 |
| 082028 | Cold applied joint sealant: Cross-sectional area of sealant not exceeding 100 mm2 |
| 082029 | Cold applied joint sealant: Cross-sectional area of sealant exceeding 100 mm2 but not exceeding 150 mm2. |
| 082030 | Cold applied joint sealant: Cross-sectional area of sealant exceeding 150 mm2 but not exceeding 200 mm2. |
| 082031 | Cold applied joint sealant: Cross-sectional area of sealant exceeding 200 mm2 but not exceeding 250 mm2. |
| 082032 | Cold applied joint sealant: Cross-sectional area of sealant exceeding 250 mm2 but not exceeding 300 mm2. |
| 082033 | Cold applied joint sealant: Cross-sectional area of sealant exceeding 300 mm2 but not exceeding 350 mm2. |
| 082034 | Cold applied joint sealant: Cross-sectional area of sealant exceeding 350 mm2 but not exceeding 400 mm2. |
| 082035 | Cold applied joint sealant: Cross-sectional area of sealant exceeding 400 mm2 but not exceeding 450 mm2. |
| 082036 | Cold applied joint sealant: Cross-sectional area of sealant exceeding 450 mm2 but not exceeding 500 mm2. |
| 082037 | Cold applied joint sealant: Cross-sectional area of sealant exceeding 500 mm2 but not exceeding 600 mm2. |
| 082038 | Cold applied joint sealant: Cross-sectional area of sealant exceeding 600 mm2 but not exceeding 700 mm2. |
| 082039 | Cold applied joint sealant: Cross-sectional area of sealant exceeding 700 mm2 but not exceeding 800 mm2. |
| 082040 | Cold applied joint sealant: Cross-sectional area of sealant exceeding 800 mm2 but not exceeding 900 mm2. |
| 082041 | Cold applied joint sealant: Cross-sectional area of sealant exceeding 900 mm2 but not exceeding 1000 mm2. |
| 082042 | Cold applied joint sealant: Cross-sectional area of sealant exceeding 1000 mm2 but not exceeding 1250 mm2. |
| 082043 | Cold applied joint sealant: Cross-sectional area of sealant exceeding 1250 mm2 but not exceeding 1500 mm2. |
| 082044 | Fine cold asphalt at joint. |
| 082045 | Remove joint fillers. |
| 082046 | Remove fine cold asphalt at joints. |
| 082047 | Remove Rigiflex or similar material. |
| 082048 | Concrete run-in: Area not exceeding 10 m2. |
| 082049 | Concrete run-in: Area exceeding 10 m2 but not exceeding 15 m2. |
| 082050 | Concrete run-in: Area exceeding 15 m2 but not exceeding 20 m2. |
| 082051 | Concrete run-in: Area exceeding 20 m2 but not exceeding 25 m2. |
| 082052 | Concrete run-in: Area exceeding 25 m2 but not exceeding 30 m2. |
| 082053 | Concrete run-in: Area exceeding 30 m2 but not exceeding 35 m2. |
| 082054 | Concrete run-in: Area exceeding 35 m2 but not exceeding 40 m2. |
| 082055 | Concrete run-in: Area exceeding 40 m2 but not exceeding 45 m2. |
| 082056 | Concrete run-in: Area exceeding 45 m2 but not exceeding 50 m2. |
| 082057 | Extra over Item No. 082/056 for the part of area in excess of 50 m2. |
| 082058 | Reinstatement of small areas for concrete pavement Area not exceeding 2.0 m2. |
| 082059 | Reinstatement of small areas for concrete pavement Area exceeding 2.0 m2 but not exceeding 4.0 m2. |
| 083001 | Backing and foundation to kerb with rigid pavement: Thickness of foundation not exceeding 150 mm. |
| 083002 | Backing and foundation to kerb with rigid pavement: Thickness of foundation exceeding 150 mm but not exceeding 200 mm. |
| 083003 | Backing and foundation to kerb with flexible pavement: Thickness of foundation not exceeding 150 mm. |
| 083004 | Backing and foundation to kerb with flexible pavement: Thickness of foundation exceeding 150 mm but not exceeding 200 mm. |
| 083005 | Backing and foundation to kerb with flexible pavement: Thickness of foundation exceeding 200 mm but not exceeding 250 mm. |
| 083006 | Backing and foundation to kerb with flexible pavement: Thickness of foundation exceeding 250 mm but not exceeding 300 mm. |
| 083007 | Backing and foundation to kerb with flexible pavement: Thickness of foundation exceeding 300 mm but not exceeding 350 mm. |
| 083008 | Supply precast concrete kerbs as shown in Drawing No. WSD 5.4. |
| 083009 | Remove kerb for reuse. |
| 083010 | Fix kerb. |
| 083011 | Grade 30/20 concrete Margin or edging. |
| 083012 | Grade 30/20 concrete Flat channel. |
| 083013 | Grade 30/20 concrete Dish channel. |
| 083014A | Concrete to footways, 50 mm thick. Grade 40/20D |
| 083014B | Concrete to footways, 50 mm thick. Grade 30/20D |
| 083014C | Concrete to footways, 50 mm thick. Grade 30/20S |
| 083014D | Concrete to footways, 50 mm thick. Grade 20/40S |
| 083014E | Concrete to footways, 50 mm thick. Grade 20/20S |
| 083014F | Concrete to footways, 50 mm thick. Grade 10/40S |
| 083014G | Concrete to footways, 50 mm thick. Grade 10/20S |
| 083015A | Extra over Item No. 083/014 for each additional 25 mm of thickness in excess of 50 mm. Grade 40/20D |
| 083015B | Extra over Item No. 083/014 for each additional 25 mm of thickness in excess of 50 mm. Grade 30/20D |
| 083015C | Extra over Item No. 083/014 for each additional 25 mm of thickness in excess of 50 mm. Grade 30/20S |
| 083015D | Extra over Item No. 083/014 for each additional 25 mm of thickness in excess of 50 mm. Grade 20/40S |
| 083015E | Extra over Item No. 083/014 for each additional 25 mm of thickness in excess of 50 mm. Grade 20/20S |
| 083015F | Extra over Item No. 083/014 for each additional 25 mm of thickness in excess of 50 mm. Grade 10/40S |
| 083015G | Extra over Item No. 083/014 for each additional 25 mm of thickness in excess of 50 mm. Grade 10/20S |
| 083016 | Extra over Item Nos. 083/014 and 083/015 for concrete footways, cycletracks and paved areas with rapid hardening concrete. |
| 083017 | Reinstatement of small areas for concrete footways, cycletracks and paved areas Area not exceeding 2.0 m2. |
| 083018 | Reinstatement of small areas for concrete footways, cycletracks and paved areas Area exceeding 2.0 m2 but not exceeding 4.0 m2. |
| 083019 | Remove precast concrete paving slab/block. |
| 083020 | Remove for re-use precast concrete paving slab/block. |
| 083021 | Precast concrete paving slabs. |
| 083022 | Precast concrete paving blocks 60 mm thick. |
| 083023 | Precast concrete paving blocks 80 mm thick. |
| 083024 | Lay only precast concrete paving slabs. |
| 083025 | Lay only precast concrete paving blocks. |
| 083026 | Remove tactile paving block/slab/sett of any materials, tactile clay paver/paving sett and tactile tile. |
| 083027 | Remove for re-use tactile paving block/slab/sett of any materials, tactile clay paver/paving sett and tactile tile. |
| 083028 | Supply and lay tactile paving block/slab/sett as shown in Drawing Nos. H 5118 and H 5123. |
| 083029 | Supply and lay tactile clay paver/paving sett as shown in Drawing Nos. H 5118 and H 5123. |
| 083030 | Supply and lay tactile artificial granite paving sett/block/slab as shown in Drawing Nos. H 5118 and H 5123. |
| 083031 | Supply and lay tactile natural granite paving block 200 mm x 100 mm, 50 mm to 60 mm thick, as shown in Drawing Nos. H 5118 and H 5123, any textured upper face. |
| 083032 | Supply and lay tactile natural granite paving slab 300 mm x 300 mm, 50 mm to 60 mm thick, as shown in Drawing Nos. H 5118 and H 5123, any textured upper face. |
| 083033 | Supply and lay tactile tile as shown in Drawing Nos. H 5118 and H 5123. |
| 083034 | Lay only tactile paving block/slab/sett of any materials, tactile clay paver/paving sett and tactile tile. |
| 083035 | PVC Speed Bumps Supply and fix 420 mm x 500 mm x 50 mm inner segment. |
| 083036 | PVC Speed Bumps Supply and fix 420 mm x 210 mm x 50 mm shoulder piece. |
| 083037 | PVC Speed Bumps Extra over Item Nos. 083/035 and 083/036 for removing existing speed bumps. |
| 083038 | PVC Speed Bumps Remove for reuse 420 mm x 500 mm x 50 mm inner segment. |
| 083039 | PVC Speed Bumps Remove for reuse 420 mm x 210 mm x 50 mm shoulder piece. |
| 083040 | PVC Speed Bumps Fix only 420 mm x 500 mm x 50 mm inner segment. |
| 083041 | PVC Speed Bumps Fix only 420 mm x 210 mm x 50 mm shoulder piece. |
| 090001 | Road markings Paint Areas. |
| 090002 | Road markings Paint Letter, numeral, symbol or Chinese character. |
| 090003 | Road markings Paint Directional arrow. |
| 090004 | Road markings Paint Yellow or white box junction. |
| 090005 | Themoplastic road marking (Plasticized Synthetic Hydrocarbon Resin) Areas. |
| 090006 | Themoplastic road marking (Plasticized Synthetic Hydrocarbon Resin) Letter, numeral, symbol or Chinese character. |
| 090007 | Themoplastic road marking (Plasticized Synthetic Hydrocarbon Resin) Directional arrow. |
| 090008 | Themoplastic road marking (Plasticized Synthetic Hydrocarbon Resin) Yellow or white box junction. |
| 090009 | Thermoplastic road marking (Alkyd Resin) Areas. |
| 090010 | Thermoplastic road marking (Alkyd Resin) Letter, numeral, symbol or Chinese character. |
| 090011 | Thermoplastic road marking (Alkyd Resin) Directional arrow. |
| 090012 | Thermoplastic road marking (Alkyd Resin) Yellow or white box junction. |
| 090013 | "Stamark" or similar approved road marking film Areas. |
| 090014 | "Stamark" or similar approved road marking film Letter or numeral. |
| 090015 | "Stamark" or similar approved road marking film Character. |
| 090016 | "Stamark" or similar approved road marking film Directional arrow. |
| 090017 | "Stamark" or similar approved road marking film Yellow or white box junction. |
| 090018 | Cold setting road marking Areas. |
| 090019 | Cold setting road marking Letter, numeral, symbol or Chinese character. |
| 090020 | Cold setting road marking Directional arrow. |
| 090021 | Cold setting road marking Yellow or white box junction. |
| 090022 | Retroflective road marking tape Areas. |
| 090023 | Retroflective road marking tape Letter, numeral, symbol or Chinese character. |
| 090024 | Retroflective road marking tape Directional arrow. |
| 090025 | Retroflective road marking tape Yellow or white box junction. |
| 090026 | Remove road paint or marking Areas. |
| 090027 | Remove road paint or marking Letter, numeral, symbol or Chinese character. |
| 090028 | Remove road paint or marking Directional arrow. |
| 090029 | Remove road paint or marking Yellow or white box junction. |
| 090030 | Remove thermoplastic marking Areas. |
| 090031 | Remove thermoplastic marking Letter, numeral, symbol or Chinese character. |
| 090032 | Remove thermoplastic marking Directional arrow. |
| 090033 | Remove thermoplastic marking Yellow or white box junction. |
| 091001 | Supply Road stud. |
| 091002 | Supply Non-depressible reflective road stud, white or coloured lens - one way. |
| 091003 | Supply Non-depressible reflective road stud, white or coloured lens - two way. |
| 091004 | Supply Depressible reflective road stud complete with removable insert. |
| 091005 | Supply Removable insert to depressible stud. |
| 091006 | Fix Road stud in flexible pavement. |
| 091007 | Fix Road stud in rigid pavement. |
| 091008 | Fix Non-depressible reflective road stud in flexible pavement. |
| 091009 | Fix Non-depressible reflective road stud in rigid pavement. |
| 091010 | Fix Depressible reflective road stud in flexible pavement. |
| 091011 | Fix Depressible reflective road stud in rigid pavement. |
| 091012 | Fix Removable insert to depressible stud. |
| 091013 | Remove Road stud in flexible pavement. |
| 091014 | Remove Road stud in rigid pavement. |
| 091015 | Remove Reflective road stud in flexible pavement, non-depressible or depressible. |
| 091016 | Remove Reflective road stud in rigid pavement, non-depressible or depressible. |
| 091017 | Remove Removable insert to depressible stud. |
| 091018 | Remove for re-use Road stud in flexible pavement. |
| 091019 | Remove for re-use Road stud in rigid pavement. |
| 091020 | Remove for re-use Reflective road stud in flexible pavement, non-depressible or depressible. |
| 091021 | Remove for re-use Reflective road stud in rigid pavement, non-depressible or depressible. |
| 091022 | Controller plinth type C 2000 as shown in Drawing No. H2163. |
| 091023 | Controller plinth type C 3000 as shown in Drawing No. H2164. |
| 091024 | Concrete bollard plinth as shown in Drawing Nos. H2140 and H2141. |
| 091025 | Traffic island with plan area not exceeding 2.0 m2. |
| 091026 | Traffic island with plan area exceeding 2.0 m2 but not exceeding 4.0 m2. |
| 091027 | Temporary P.V.C. cover to traffic signs not exceeding 1.0 m2. |
| 091028 | Clean Sign or plate area not exceeding 1.0 m2 and support. |
| 091029 | Clean Sign or plate, area exceeding 1.0 m2 and not exceeding 2.0 m2 and support. |
| 091030 | Clean Sign or plate, area exceeding 2.0 m2 and support. |
| 091031 | Remove Traffic sign and post. |
| 091032 | Remove Traffic sign. |
| 091033 | Remove Street name plate and support. |
| 091034 | Remove Street name plate. |
| 091035 | Remove Parking meter post. |
| 091036 | Remove Traffic signal pole. |
| 091037 | Remove Directional sign plate. |
| 091038 | Fix Traffic sign and post as shown in Drawing Nos. H2147 and H2148. |
| 091039 | Fix Traffic sign as shown in Drawing Nos. H2147 and H2148. |
| 091040 | Fix Street name plate and support (self mounting) as shown in Drawing No. H2205. |
| 091041 | Fix Street name plate and support (self mounting) as shown in Drawing No. H2205, but combined with tubular railing. |
| 091042 | Fix Street name plate onto support, wall tubular railing or ornamental railing as shown in Drawing No. H2206 & H2207. |
| 091043 | Fix Parking meter post. |
| 091044 | Fix Traffic sign pole as Drawing No. H2146. |
| 091045 | Fix Directional sign plate. |
| 091046 | Supply 3 mm aluminium directional sign backing plate. |
| 091047 | Supply Plain stove enameled street name plate. |
| 091048 | Supply "Scotchlite" street name plate. |
| 091049 | Supply "Scotchlite" traffic sign plate, area not exceeding 1.0 m2. |
| 091050 | Supply "Scotchlite" traffic sign plate, area exceeding 1.0 m2. |
| 091051 | Supply "Scotchlite" directional sign plate. |
| 091052 | Supply Traffic sign post. |
| 091053 | Supply Street name plate support. |
| 091054 | Supply Parking meter post. |
| 091055 | Supply Traffic signal pole. |
| 091056 | Remove for re-use Traffic sign and post. |
| 091057 | Remove for re-use Traffic sign. |
| 091058 | Remove for re-use Street name plate and support. |
| 091059 | Remove for re-use Street name plate. |
| 091060 | Remove for re-use Parking meter post. |
| 091061 | Remove for re-use Traffic signal pole. |
| 091062 | Remove for re-use Directional sign plate. |
| 095001A | Supply Ductile iron pipes. Nominal diameter of pipe 80mm & under |
| 095001B | Supply Ductile iron pipes. Nominal diameter of pipe 100mm |
| 095001C | Supply Ductile iron pipes. Nominal diameter of pipe 125 -150mm |
| 095001D | Supply Ductile iron pipes. Nominal diameter of pipe 200mm |
| 095001E | Supply Ductile iron pipes. Nominal diameter of pipe 250mm |
| 095001F | Supply Ductile iron pipes. Nominal diameter of pipe 300 - 350mm |
| 095001G | Supply Ductile iron pipes. Nominal diameter of pipe 400mm |
| 095001H | Supply Ductile iron pipes. Nominal diameter of pipe 450 - 525mm |
| 095001I | Supply Ductile iron pipes. Nominal diameter of pipe 600 - 675mm |
| 095002A | Supply Epoxy coated ductile iron pipes. Nominal diameter of pipe 80mm & under |
| 095002B | Supply Epoxy coated ductile iron pipes. Nominal diameter of pipe 100mm |
| 095002C | Supply Epoxy coated ductile iron pipes. Nominal diameter of pipe 125 -150mm |
| 095002D | Supply Epoxy coated ductile iron pipes. Nominal diameter of pipe 200mm |
| 095002E | Supply Epoxy coated ductile iron pipes. Nominal diameter of pipe 250mm |
| 095002F | Supply Epoxy coated ductile iron pipes. Nominal diameter of pipe 300 - 350mm |
| 095002G | Supply Epoxy coated ductile iron pipes. Nominal diameter of pipe 400mm |
| 095002H | Supply Epoxy coated ductile iron pipes. Nominal diameter of pipe 450 - 525mm |
| 095002I | Supply Epoxy coated ductile iron pipes. Nominal diameter of pipe 600 - 675mm |
| 095003B | Supply Bitumen lined steel pipes. Nominal diameter of pipe 100mm |
| 095003C | Supply Bitumen lined steel pipes. Nominal diameter of pipe 125 -150mm |
| 095003D | Supply Bitumen lined steel pipes. Nominal diameter of pipe 200mm |
| 095003E | Supply Bitumen lined steel pipes. Nominal diameter of pipe 250mm |
| 095003F | Supply Bitumen lined steel pipes. Nominal diameter of pipe 300 - 350mm |
| 095003G | Supply Bitumen lined steel pipes. Nominal diameter of pipe 400mm |
| 095003H | Supply Bitumen lined steel pipes. Nominal diameter of pipe 450 - 525mm |
| 095003I | Supply Bitumen lined steel pipes. Nominal diameter of pipe 600 - 675mm |
| 095003J | Supply Bitumen lined steel pipes. Nominal diameter of pipe 700 - 750mm |
| 095003K | Supply Bitumen lined steel pipes. Nominal diameter of pipe 800 mm |
| 095003L | Supply Bitumen lined steel pipes. Nominal diameter of pipe 900 mm |
| 095003M | Supply Bitumen lined steel pipes. Nominal diameter of pipe 1000 - 1100 mm |
| 095003N | Supply Bitumen lined steel pipes. Nominal diameter of pipe 1200 mm |
| 095003O | Supply Bitumen lined steel pipes. Nominal diameter of pipe 1350 - 1400 mm |
| 095003P | Supply Bitumen lined steel pipes. Nominal diameter of pipe 1600 mm |
| 095003Q | Supply Bitumen lined steel pipes. Nominal diameter of pipe 1800 mm |
| 095003R | Supply Bitumen lined steel pipes. Nominal diameter of pipe 1950 - 2100 mm |
| 095003S | Supply Bitumen lined steel pipes. Nominal diameter of pipe 2200 mm |
| 095003T | Supply Bitumen lined steel pipes. Nominal diameter of pipe 2400 mm |
| 095004B | Supply Concrete lined steel pipes. Nominal diameter of pipe 100mm |
| 095004C | Supply Concrete lined steel pipes. Nominal diameter of pipe 125 -150mm |
| 095004D | Supply Concrete lined steel pipes. Nominal diameter of pipe 200mm |
| 095004E | Supply Concrete lined steel pipes. Nominal diameter of pipe 250mm |
| 095004F | Supply Concrete lined steel pipes. Nominal diameter of pipe 300 - 350mm |
| 095004G | Supply Concrete lined steel pipes. Nominal diameter of pipe 400mm |
| 095004H | Supply Concrete lined steel pipes. Nominal diameter of pipe 450 - 525mm |
| 095004I | Supply Concrete lined steel pipes. Nominal diameter of pipe 600 - 675mm |
| 095004J | Supply Concrete lined steel pipes. Nominal diameter of pipe 700 - 750mm |
| 095004K | Supply Concrete lined steel pipes. Nominal diameter of pipe 800 mm |
| 095004L | Supply Concrete lined steel pipes. Nominal diameter of pipe 900 mm |
| 095005aC | Supply Epoxy coated steel pipes (PN 64). Nominal diameter of pipe 125 - 150 mm |
| 095005aD | Supply Epoxy coated steel pipes (PN 64). Nominal diameter of pipe 200 mm |
| 095005B | Supply Epoxy coated steel pipes. Nominal diameter of pipe 100mm |
| 095005C | Supply Epoxy coated steel pipes. Nominal diameter of pipe 125 -150mm |
| 095005D | Supply Epoxy coated steel pipes. Nominal diameter of pipe 200mm |
| 095005E | Supply Epoxy coated steel pipes. Nominal diameter of pipe 250mm |
| 095005F | Supply Epoxy coated steel pipes. Nominal diameter of pipe 300 - 350mm |
| 095005G | Supply Epoxy coated steel pipes. Nominal diameter of pipe 400mm |
| 095005H | Supply Epoxy coated steel pipes. Nominal diameter of pipe 450 - 525mm |
| 095005I | Supply Epoxy coated steel pipes. Nominal diameter of pipe 600 - 675mm |
| 095005J | Supply Epoxy coated steel pipes. Nominal diameter of pipe 700 - 750mm |
| 095005K | Supply Epoxy coated steel pipes. Nominal diameter of pipe 800 mm |
| 095005L | Supply Epoxy coated steel pipes. Nominal diameter of pipe 900 mm |
| 095005M | Supply Epoxy coated steel pipes. Nominal diameter of pipe 1000 - 1100 mm |
| 095005N | Supply Epoxy coated steel pipes. Nominal diameter of pipe 1200 mm |
| 095005O | Supply Epoxy coated steel pipes. Nominal diameter of pipe 1350 - 1400 mm |
| 095005P | Supply Epoxy coated steel pipes. Nominal diameter of pipe 1600 mm |
| 095006B | Supply U.P.V.C. pipes. Nominal diameter of pipe 20 mm |
| 095006C | Supply U.P.V.C. pipes. Nominal diameter of pipe 25 mm |
| 095006D | Supply U.P.V.C. pipes. Nominal diameter of pipe 40 mm |
| 095006E | Supply U.P.V.C. pipes. Nominal diameter of pipe 50 mm |
| 095006F | Supply U.P.V.C. pipes. Nominal diameter of pipe 80 mm |
| 095006G | Supply U.P.V.C. pipes. Nominal diameter of pipe 100 mm |
| 095006H | Supply U.P.V.C. pipes. Nominal diameter of pipe 150 mm |
| 095006I | Supply U.P.V.C. pipes. Nominal diameter of pipe 200 mm |
| 095006J | Supply U.P.V.C. pipes. Nominal diameter of pipe 250 mm |
| 095007B | Supply Lined G.I. pipes. Nominal diameter of pipe 20 mm |
| 095007C | Supply Lined G.I. pipes. Nominal diameter of pipe 25 mm |
| 095007D | Supply Lined G.I. pipes. Nominal diameter of pipe 40 mm |
| 095007E | Supply Lined G.I. pipes. Nominal diameter of pipe 50 mm |
| 095007F | Supply Lined G.I. pipes. Nominal diameter of pipe 80 mm |
| 095007G | Supply Lined G.I. pipes. Nominal diameter of pipe 100 mm |
| 095008B | Supply PE pipes. Nominal diameter of pipe 20 mm |
| 095008C | Supply PE pipes. Nominal diameter of pipe 25 mm |
| 095008D | Supply PE pipes. Nominal diameter of pipe 40 mm |
| 095008E | Supply PE pipes. Nominal diameter of pipe 50 mm |
| 095008F | Supply PE pipes. Nominal diameter of pipe 80 mm |
| 095008G | Supply PE pipes. Nominal diameter of pipe 100 mm |
| 095008H | Supply PE pipes. Nominal diameter of pipe 150 mm |
| 095008I | Supply PE pipes. Nominal diameter of pipe 200 mm |
| 095008J | Supply PE pipes. Nominal diameter of pipe 250 mm |
| 095009A | Supply UPVC Lined stainless steel pipes. Nominal diameter of pipe 15 mm |
| 095009B | Supply UPVC Lined stainless steel pipes. Nominal diameter of pipe 20 mm |
| 095009C | Supply UPVC Lined stainless steel pipes. Nominal diameter of pipe 25 mm |
| 095009D | Supply UPVC Lined stainless steel pipes. Nominal diameter of pipe 40 mm |
| 095009E | Supply UPVC Lined stainless steel pipes. Nominal diameter of pipe 50 mm |
| 095009F | Supply UPVC Lined stainless steel pipes. Nominal diameter of pipe 80 mm |
| 095009G | Supply UPVC Lined stainless steel pipes. Nominal diameter of pipe 100 mm |
| 095009H | Supply UPVC Lined stainless steel pipes. Nominal diameter of pipe 150 mm |
| 095009I | Supply UPVC Lined stainless steel pipes. Nominal diameter of pipe 200 mm |
| 095010A | Supply Stainless steel pipes. Nominal diameter of pipe 15 mm |
| 095010B | Supply Stainless steel pipes. Nominal diameter of pipe 20 mm |
| 095010C | Supply Stainless steel pipes. Nominal diameter of pipe 25 mm |
| 095010D | Supply Stainless steel pipes. Nominal diameter of pipe 40 mm |
| 095010E | Supply Stainless steel pipes. Nominal diameter of pipe 50 mm |
| 095010F | Supply Stainless steel pipes. Nominal diameter of pipe 80 mm |
| 095010G | Supply Stainless steel pipes. Nominal diameter of pipe 100 mm |
| 095010H | Supply Stainless steel pipes. Nominal diameter of pipe 150 mm |
| 095010I | Supply Stainless steel pipes. Nominal diameter of pipe 200 mm |
| 096001A | Supply Vertical gate valves with resilient seating. Nominal diameter of pipe 80mm & under |
| 096001B | Supply Vertical gate valves with resilient seating. Nominal diameter of pipe 100 mm |
| 096001C | Supply Vertical gate valves with resilient seating. Nominal diameter of pipe 125 -150 mm |
| 096001D | Supply Vertical gate valves with resilient seating. Nominal diameter of pipe 200 mm |
| 096001E | Supply Vertical gate valves with resilient seating. Nominal diameter of pipe 250 mm |
| 096001F | Supply Vertical gate valves with resilient seating. Nominal diameter of pipe 300 - 350 mm |
| 096001G | Supply Vertical gate valves with resilient seating. Nominal diameter of pipe 400mm |
| 096001H | Supply Vertical gate valves with resilient seating. Nominal diameter of pipe 450 - 525mm |
| 096001I | Supply Vertical gate valves with resilient seating. Nominal diameter of pipe 600 - 675mm |
| 096001J | Supply Vertical gate valves with resilient seating. Nominal diameter of pipe 700 - 750 mm |
| 096002A | Supply Vertical gate valves with copper alloy faced seating. Nominal diameter of pipe 80mm & under |
| 096002B | Supply Vertical gate valves with copper alloy faced seating. Nominal diameter of pipe 100 mm |
| 096002C | Supply Vertical gate valves with copper alloy faced seating. Nominal diameter of pipe 125 -150 mm |
| 096002D | Supply Vertical gate valves with copper alloy faced seating. Nominal diameter of pipe 200 mm |
| 096002E | Supply Vertical gate valves with copper alloy faced seating. Nominal diameter of pipe 250 mm |
| 096002F | Supply Vertical gate valves with copper alloy faced seating. Nominal diameter of pipe 300 - 350 mm |
| 096002G | Supply Vertical gate valves with copper alloy faced seating. Nominal diameter of pipe 400mm |
| 096002H | Supply Vertical gate valves with copper alloy faced seating. Nominal diameter of pipe 450 - 525mm |
| 096002I | Supply Vertical gate valves with copper alloy faced seating. Nominal diameter of pipe 600 - 675mm |
| 096002J | Supply Vertical gate valves with copper alloy faced seating. Nominal diameter of pipe 700 - 750 mm |
| 096003aa | Supply Vertical stainless steel gate valves.Nominal diameter of pipe80mm & under |
| 096003ab | Supply Vertical stainless steel gate valves.Nominal diameter of pipe100 mm |
| 096003ac | Supply Vertical stainless steel gate valves.Nominal diameter of pipe125 -150 mm |
| 096003ad | Supply Vertical stainless steel gate valves.Nominal diameter of pipe200 mm |
| 096003ae | Supply Vertical stainless steel gate valves.Nominal diameter of pipe250 mm |
| 096003af | Supply Vertical stainless steel gate valves.Nominal diameter of pipe300 - 350 mm |
| 096003bg | Supply Horizontal stainless steel gate valves.Nominal diameter of pipe400mm |
| 096003bh | Supply Horizontal stainless steel gate valves.Nominal diameter of pipe450 - 525mm |
| 096003bi | Supply Horizontal stainless steel gate valves.Nominal diameter of pipe600 - 675mm |
| 096003G | Supply Horizontal gate valves. Nominal diameter of pipe 400mm |
| 096003H | Supply Horizontal gate valves. Nominal diameter of pipe 450 - 525mm |
| 096003I | Supply Horizontal gate valves. Nominal diameter of pipe 600 - 675mm |
| 096003J | Supply Horizontal gate valves. Nominal diameter of pipe 700 - 750 mm |
| 096003K | Supply Horizontal gate valves. Nominal diameter of pipe 800 mm |
| 096003L | Supply Horizontal gate valves. Nominal diameter of pipe 900 mm |
| 096003M | Supply Horizontal gate valves. Nominal diameter of pipe 1000 - 1100 mm |
| 096003N | Supply Horizontal gate valves. Nominal diameter of pipe 1200 mm |
| 096004A | Supply Non-return valves. Nominal diameter of pipe 80mm & under |
| 096004B | Supply Non-return valves. Nominal diameter of pipe 100 mm |
| 096004C | Supply Non-return valves. Nominal diameter of pipe 125 -150 mm |
| 096004D | Supply Non-return valves. Nominal diameter of pipe 200 mm |
| 096004E | Supply Non-return valves. Nominal diameter of pipe 250 mm |
| 096004F | Supply Non-return valves. Nominal diameter of pipe 300 - 350 mm |
| 096004G | Supply Non-return valves. Nominal diameter of pipe 400mm |
| 096004H | Supply Non-return valves. Nominal diameter of pipe 450 - 525mm |
| 096004I | Supply Non-return valves. Nominal diameter of pipe 600 - 675mm |
| 096004J | Supply Non-return valves. Nominal diameter of pipe 700 - 750 mm |
| 096004K | Supply Non-return valves. Nominal diameter of pipe 800 mm |
| 096004L | Supply Non-return valves. Nominal diameter of pipe 900 mm |
| 096004M | Supply Non-return valves. Nominal diameter of pipe 1000 - 1100 mm |
| 096004N | Supply Non-return valves. Nominal diameter of pipe 1200 mm |
| 096005A | Supply Butterfly valves. Nominal diameter of pipe 80mm & under |
| 096005B | Supply Butterfly valves. Nominal diameter of pipe 100 mm |
| 096005C | Supply Butterfly valves. Nominal diameter of pipe 125 -150 mm |
| 096005D | Supply Butterfly valves. Nominal diameter of pipe 200 mm |
| 096005E | Supply Butterfly valves. Nominal diameter of pipe 250 mm |
| 096005F | Supply Butterfly valves. Nominal diameter of pipe 300 - 350 mm |
| 096005G | Supply Butterfly valves. Nominal diameter of pipe 400mm |
| 096005H | Supply Butterfly valves. Nominal diameter of pipe 450 - 525mm |
| 096005I | Supply Butterfly valves. Nominal diameter of pipe 600 - 675mm |
| 096005J | Supply Butterfly valves. Nominal diameter of pipe 700 - 750 mm |
| 096005K | Supply Butterfly valves. Nominal diameter of pipe 800 mm |
| 096005L | Supply Butterfly valves. Nominal diameter of pipe 900 mm |
| 096005M | Supply Butterfly valves. Nominal diameter of pipe 1000 - 1100 mm |
| 096006(I)A | Supply Steel tees or angle branches - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 80mm & under |
| 096006(I)B | Supply Steel tees or angle branches - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 100 mm |
| 096006(I)C | Supply Steel tees or angle branches - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 125 -150 mm |
| 096006(I)D | Supply Steel tees or angle branches - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 200 mm |
| 096006(I)E | Supply Steel tees or angle branches - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 250 mm |
| 096006(I)F | Supply Steel tees or angle branches - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 300 - 350 mm |
| 096006(I)G | Supply Steel. tees or angle branches - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 400mm |
| 096006(I)H | Supply Steel tees or angle branches - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 450 - 525mm |
| 096006(I)I | Supply Steel tees or angle branches - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 600 - 675mm |
| 096006(II)A | Supply Steel tees or angle branches - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 80mm & under |
| 096006(II)B | Supply Steel tees or angle branches - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 100 mm |
| 096006(II)C | Supply Steel tees or angle branches - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 125 -150 mm |
| 096006(II)D | Supply Steel tees or angle branches - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 200 mm |
| 096006(II)E | Supply Steel tees or angle branches - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 250 mm |
| 096006(II)F | Supply Steel tees or angle branches - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 300 - 350 mm |
| 096006(II)G | Supply Steel tees or angle branches - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 400mm |
| 096006(II)H | Supply Steel tees or angle branches - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 450 - 525mm |
| 096006(II)I | Supply Steel tees or angle branches - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 600 - 675mm |
| 096006(III)A | Supply Steel tees or angle branches - refer to making protection of epoxy coating etc. to fittings fabricated on site in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 80mm & under |
| 096006(III)B | Supply Steel tees or angle branches - refer to making protection of epoxy coating etc. to fittings fabricated on site in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 100 mm |
| 096006(III)C | Supply Steel tees or angle branches - refer to making protection of epoxy coating etc. to fittings fabricated on site in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 125 -150 mm |
| 096006(III)D | Supply Steel tees or angle branches - refer to making protection of epoxy coating etc. to fittings fabricated on site in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 200 mm |
| 096006(III)E | Supply Steel tees or angle branches - refer to making protection of epoxy coating etc. to fittings fabricated on site in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 250 mm |
| 096006(III)F | Supply Steel tees or angle branches - refer to making protection of epoxy coating etc. to fittings fabricated on site in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 300 - 350 mm |
| 096006(III)G | Supply Steel tees or angle branches - refer to making protection of epoxy coating etc. to fittings fabricated on site in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 400mm |
| 096006(III)H | Supply Steel tees or angle branches - refer to making protection of epoxy coating etc. to fittings fabricated on site in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 450 - 525mm |
| 096006(III)I | Supply Steel tees or angle branches - refer to making protection of epoxy coating etc. to fittings fabricated on site in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 600 - 675mm |
| 096007(I)I | Supply Steel concentric tapers - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 600 - 675mm |
| 096007(I)J | Supply Steel concentric tapers - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 700 - 750 mm |
| 096007(I)K | Supply Steel concentric tapers - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 800 mm |
| 096007(I)L | Supply Steel concentric tapers - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 900 mm |
| 096007(I)M | Supply Steel concentric tapers - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 1000 - 1100 mm |
| 096007(I)N | Supply Steel concentric tapers - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 1200 mm |
| 096007(II)I | Supply Steel concentric tapers - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 600 - 675mm |
| 096007(II)J | Supply Steel concentric tapers - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 700 - 750 mm |
| 096007(II)K | Supply Steel concentric tapers - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 800 mm |
| 096007(II)L | Supply Steel concentric tapers - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 900 mm |
| 096007(II)M | Supply Steel concentric tapers - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 1000 - 1100 mm |
| 096007(II)N | Supply Steel concentric tapers - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 1200 mm |
| 096007(III)I | Supply Steel concentric tapers - refer to making protection of epoxy coating etc. to fittings fabricated on site in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 600 - 675mm |
| 096007(III)J | Supply Steel concentric tapers - refer to making protection of epoxy coating etc. to fittings fabricated on site in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 700 - 750 mm |
| 096007(III)K | Supply Steel concentric tapers - refer to making protection of epoxy coating etc. to fittings fabricated on site in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 800 mm |
| 096007(III)L | Supply Steel concentric tapers - refer to making protection of epoxy coating etc. to fittings fabricated on site in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 900 mm |
| 096007(III)M | Supply Steel concentric tapers - refer to making protection of epoxy coating etc. to fittings fabricated on site in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 1000 - 1100 mm |
| 096007(III)N | Supply Steel concentric tapers - refer to making protection of epoxy coating etc. to fittings fabricated on site in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 1200 mm |
| 096008(I)C | Supply Steel blank flanges - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 125 -150 mm |
| 096008(I)D | Supply Steel blank flanges - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 200 mm |
| 096008(I)E | Supply Steel blank flanges - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 250 mm |
| 096008(I)F | Supply Steel blank flanges - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 300 - 350 mm |
| 096008(I)G | Supply Steel blank flanges - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 400mm |
| 096008(I)H | Supply Steel blank flanges - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 450 - 525mm |
| 096008(I)I | Supply Steel blank flanges - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 600 - 675mm |
| 096008(I)J | Supply Steel blank flanges - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 700 - 750 mm |
| 096008(I)K | Supply Steel blank flanges - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 800 mm |
| 096008(I)L | Supply Steel blank flanges - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 900 mm |
| 096008(I)M | Supply Steel blank flanges - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 1000 - 1100 mm |
| 096008(I)N | Supply Steel blank flanges - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 1200 mm |
| 096008(I)O | Supply Steel blank flanges - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 1350 - 1400 mm |
| 096008(I)P | Supply Steel blank flanges - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 1600 mm |
| 096008(I)Q | Supply Steel blank flanges - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 1800 mm |
| 096008(I)R | Supply Steel blank flanges - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 1950 - 2100 mm |
| 096008(I)S | Supply Steel blank flanges - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 2200 mm |
| 096008(I)T | Supply Steel blank flanges - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 2400 mm |
| 096008(II)C | Supply Steel blank flanges - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 125 -150 mm |
| 096008(II)D | Supply Steel blank flanges - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 200 mm |
| 096008(II)E | Supply Steel blank flanges - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 250 mm |
| 096008(II)F | Supply Steel blank flanges - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 300 - 350 mm |
| 096008(II)G | Supply Steel blank flanges - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 400mm |
| 096008(II)H | Supply Steel blank flanges - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 450 - 525mm |
| 096008(II)I | Supply Steel blank flanges - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 600 - 675mm |
| 096008(II)J | Supply Steel blank flanges - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 700 - 750 mm |
| 096008(II)K | Supply Steel blank flanges - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 800 mm |
| 096008(II)L | Supply Steel blank flanges - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 900 mm |
| 096008(II)M | Supply Steel blank flanges - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 1000 - 1100 mm |
| 096008(II)N | Supply Steel blank flanges - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 1200 mm |
| 096008(II)O | Supply Steel blank flanges - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 1350 - 1400 mm |
| 096008(II)P | Supply Steel blank flanges - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 1600 mm |
| 096008(II)Q | Supply Steel blank flanges - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 1800 mm |
| 096008(II)R | Supply Steel blank flanges - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 1950 - 2100 mm |
| 096008(II)S | Supply Steel blank flanges - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 2200 mm |
| 096008(II)T | Supply Steel blank flanges - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 2400 mm |
| 096009(I)C | Supply Steel gussetted bends to any angle - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 125 -150 mm |
| 096009(I)D | Supply Steel gussetted bends to any angle - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 200 mm |
| 096009(I)E | Supply Steel gussetted bends to any angle - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 250 mm |
| 096009(I)F | Supply Steel gussetted bends to any angle - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 300 - 350 mm |
| 096009(I)G | Supply Steel gussetted bends to any angle - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 400mm |
| 096009(I)H | Supply Steel gussetted bends to any angle - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 450 - 525mm |
| 096009(I)I | Supply Steel gussetted bends to any angle - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 600 - 675mm |
| 096009(I)J | Supply Steel gussetted bends to any angle - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 700 - 750 mm |
| 096009(I)K | Supply Steel gussetted bends to any angle - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 800 mm |
| 096009(I)L | Supply Steel gussetted bends to any angle - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 900 mm |
| 096009(I)M | Supply Steel gussetted bends to any angle - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 1000 - 1100 mm |
| 096009(I)N | Supply Steel gussetted bends to any angle - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 1200 mm |
| 096009(II)C | Supply Steel gussetted bends to any angle - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 125 -150 mm |
| 096009(II)D | Supply Steel gussetted bends to any angle - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 200 mm |
| 096009(II)E | Supply Steel gussetted bends to any angle - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 250 mm |
| 096009(II)F | Supply Steel gussetted bends to any angle - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 300 - 350 mm |
| 096009(II)G | Supply Steel gussetted bends to any angle - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 400mm |
| 096009(II)H | Supply Steel gussetted bends to any angle - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 450 - 525mm |
| 096009(II)I | Supply Steel gussetted bends to any angle - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 600 - 675mm |
| 096009(II)J | Supply Steel gussetted bends to any angle - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 700 - 750 mm |
| 096009(II)K | Supply Steel gussetted bends to any angle - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 800 mm |
| 096009(II)L | Supply Steel gussetted bends to any angle - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 900 mm |
| 096009(II)M | Supply Steel gussetted bends to any angle - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 1000 - 1100 mm |
| 096009(II)N | Supply Steel gussetted bends to any angle - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 1200 mm |
| 096009(III)C | Supply Steel gussetted bends to any angle - refer to making protection of epoxy coating etc. to fittings fabricated on site in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 125 -150 mm |
| 096009(III)D | Supply Steel gussetted bends to any angle - refer to making protection of epoxy coating etc. to fittings fabricated on site in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 200 mm |
| 096009(III)E | Supply Steel gussetted bends to any angle - refer to making protection of epoxy coating etc. to fittings fabricated on site in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 250 mm |
| 096009(III)F | Supply Steel gussetted bends to any angle - refer to making protection of epoxy coating etc. to fittings fabricated on site in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 300 - 350 mm |
| 096009(III)G | Supply Steel gussetted bends to any angle - refer to making protection of epoxy coating etc. to fittings fabricated on site in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 400mm |
| 096009(III)H | Supply Steel gussetted bends to any angle - refer to making protection of epoxy coating etc. to fittings fabricated on site in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 450 - 525mm |
| 096009(III)I | Supply Steel gussetted bends to any angle - refer to making protection of epoxy coating etc. to fittings fabricated on site in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 600 - 675mm |
| 096009(III)J | Supply Steel gussetted bends to any angle - refer to making protection of epoxy coating etc. to fittings fabricated on site in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 700 - 750 mm |
| 096009(III)K | Supply Steel gussetted bends to any angle - refer to making protection of epoxy coating etc. to fittings fabricated on site in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 800 mm |
| 096009(III)L | Supply Steel gussetted bends to any angle - refer to making protection of epoxy coating etc. to fittings fabricated on site in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 900 mm |
| 096009(III)M | Supply Steel gussetted bends to any angle - refer to making protection of epoxy coating etc. to fittings fabricated on site in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 1000 - 1100 mm |
| 096009(III)N | Supply Steel gussetted bends to any angle - refer to making protection of epoxy coating etc. to fittings fabricated on site in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 1200 mm |
| 096010(I)A | Supply Ring flanges to Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 80mm & under |
| 096010(I)B | Supply Ring flanges to Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 100 mm |
| 096010(I)C | Supply Ring flanges to Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 125 -150 mm |
| 096010(I)D | Supply Ring flanges to Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 200 mm |
| 096010(I)E | Supply Ring flanges to Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 250 mm |
| 096010(I)F | Supply Ring flanges to Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 300 - 350 mm |
| 096010(I)G | Supply Ring flanges to Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 400mm |
| 096010(I)H | Supply Ring flanges to Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 450 - 525mm |
| 096010(I)I | Supply Ring flanges to Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 600 - 675mm |
| 096010(I)J | Supply Ring flanges to Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 700 - 750 mm |
| 096010(I)K | Supply Ring flanges to Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 800 mm |
| 096010(I)L | Supply Ring flanges to Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 900 mm |
| 096010(I)M | Supply Ring flanges to Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 1000 - 1100 mm |
| 096010(I)N | Supply Ring flanges to Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 1200 mm |
| 096010(I)O | Supply Ring flanges to Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 1350 - 1400 mm |
| 096010(I)P | Supply Ring flanges to Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 1600 mm |
| 096010(I)Q | Supply Ring flanges to Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 1800 mm |
| 096010(I)R | Supply Ring flanges to Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 1950 - 2100 mm |
| 096010(I)S | Supply Ring flanges to Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 2200 mm |
| 096010(I)T | Supply Ring flanges to Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02. Nominal diameter of pipe 2400 mm |
| 096010(II)B | Supply Ring flanges to Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 100 mm |
| 096010(II)C | Supply Ring flanges to Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 125 -150 mm |
| 096010(II)D | Supply Ring flanges to Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 200 mm |
| 096010(II)E | Supply Ring flanges to Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 250 mm |
| 096010(II)F | Supply Ring flanges to Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 300 - 350 mm |
| 096010(II)G | Supply Ring flanges to Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 400mm |
| 096010(II)H | Supply Ring flanges to Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 450 - 525mm |
| 096010(II)I | Supply Ring flanges to Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 600 - 675mm |
| 096010(II)J | Supply Ring flanges to Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 700 - 750 mm |
| 096010(II)K | Supply Ring flanges to Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 800 mm |
| 096010(II)L | Supply Ring flanges to Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 900 mm |
| 096010(II)M | Supply Ring flanges to Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 1000 - 1100 mm |
| 096010(II)N | Supply Ring flanges to Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 1200 mm |
| 096010(II)O | Supply Ring flanges to Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 1350 - 1400 mm |
| 096010(II)P | Supply Ring flanges to Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 1600 mm |
| 096010(II)Q | Supply Ring flanges to Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 1800 mm |
| 096010(II)R | Supply Ring flanges to Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 1950 - 2100 mm |
| 096010(II)S | Supply Ring flanges to Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 2200 mm |
| 096010(II)T | Supply Ring flanges to Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02. Nominal diameter of pipe 2400 mm |
| 096010a(I)C | Supply Ring flanges to steel pipes (PN 64). -refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of Appendix 22.02 to PS. Nominal diameter of pipe 125 -150 mm |
| 096010a(I)D | Supply Ring flanges to steel pipes (PN 64). -refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of Appendix 22.02 to PS. Nominal diameter of pipe 200 mm |
| 096011(I)A | Supply D.I. concentric tapers - double socket or flange - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 80mm & under |
| 096011(I)B | Supply D.I. concentric tapers - double socket or flange - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 100 mm |
| 096011(I)C | Supply D.I. concentric tapers - double socket or flange - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 125 -150 mm |
| 096011(I)D | Supply D.I. concentric tapers - double socket or flange - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 200 mm |
| 096011(I)E | Supply D.I. concentric tapers - double socket or flange - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 250 mm |
| 096011(I)F | Supply D.I. concentric tapers - double socket or flange - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 300 - 350 mm |
| 096011(I)G | Supply D.I. concentric tapers - double socket or flange - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 400mm |
| 096011(I)H | Supply D.I. concentric tapers - double socket or flange - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 450 - 525mm |
| 096011(I)I | Supply D.I. concentric tapers - double socket or flange - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 600 - 675mm |
| 096011(II)A | Supply D.I. concentric tapers - double socket or flange - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 80mm & under |
| 096011(II)B | Supply D.I. concentric tapers - double socket or flange - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 100 mm |
| 096011(II)C | Supply D.I. concentric tapers - double socket or flange - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 125 -150 mm |
| 096011(II)D | Supply D.I. concentric tapers - double socket or flange - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 200 mm |
| 096011(II)E | Supply D.I. concentric tapers - double socket or flange - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 250 mm |
| 096011(II)F | Supply D.I. concentric tapers - double socket or flange - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 300 - 350 mm |
| 096011(II)G | Supply D.I. concentric tapers - double socket or flange - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 400mm |
| 096011(II)H | Supply D.I. concentric tapers - double socket or flange - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 450 - 525mm |
| 096011(II)I | Supply D.I. concentric tapers - double socket or flange - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 600 - 675mm |
| 096012(I)A | Supply D.I. pipe bends and elbows to any angle - refer to fittings with the epoxy coating respcetively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 80mm & under |
| 096012(I)B | Supply D.I. pipe bends and elbows to any angle - refer to fittings with the epoxy coating respcetively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 100 mm |
| 096012(I)C | Supply D.I. pipe bends and elbows to any angle - refer to fittings with the epoxy coating respcetively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 125 -150 mm |
| 096012(I)D | Supply D.I. pipe bends and elbows to any angle - refer to fittings with the epoxy coating respcetively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 200 mm |
| 096012(I)E | Supply D.I. pipe bends and elbows to any angle - refer to fittings with the epoxy coating respcetively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 250 mm |
| 096012(I)F | Supply D.I. pipe bends and elbows to any angle - refer to fittings with the epoxy coating respcetively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 300 - 350 mm |
| 096012(I)G | Supply D.I. pipe bends and elbows to any angle - refer to fittings with the epoxy coating respcetively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 400mm |
| 096012(I)H | Supply D.I. pipe bends and elbows to any angle - refer to fittings with the epoxy coating respcetively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 450 - 525mm |
| 096012(I)I | Supply D.I. pipe bends and elbows to any angle - refer to fittings with the epoxy coating respcetively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 600 - 675mm |
| 096012(II)A | Supply D.I. pipe bends and elbows to any angle - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 80mm & under |
| 096012(II)B | Supply D.I. pipe bends and elbows to any angle - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 100 mm |
| 096012(II)C | Supply D.I. pipe bends and elbows to any angle - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 125 -150 mm |
| 096012(II)D | Supply D.I. pipe bends and elbows to any angle - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 200 mm |
| 096012(II)E | Supply D.I. pipe bends and elbows to any angle - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 250 mm |
| 096012(II)F | Supply D.I. pipe bends and elbows to any angle - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 300 - 350 mm |
| 096012(II)G | Supply D.I. pipe bends and elbows to any angle - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 400mm |
| 096012(II)H | Supply D.I. pipe bends and elbows to any angle - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 450 - 525mm |
| 096012(II)I | Supply D.I. pipe bends and elbows to any angle - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 600 - 675mm |
| 096013(I)A | Supply D.I. Flange spigot or socket pieces - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 80mm & under |
| 096013(I)B | Supply D.I. Flange spigot or socket pieces - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 100 mm |
| 096013(I)C | Supply D.I. Flange spigot or socket pieces - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 125 -150 mm |
| 096013(I)D | Supply D.I. Flange spigot or socket pieces - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 200 mm |
| 096013(I)E | Supply D.I. Flange spigot or socket pieces - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 250 mm |
| 096013(I)F | Supply D.I. Flange spigot or socket pieces - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 300 - 350 mm |
| 096013(I)G | Supply D.I. Flange spigot or socket pieces - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 400mm |
| 096013(I)H | Supply D.I. Flange spigot or socket pieces - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 450 - 525mm |
| 096013(I)I | Supply D.I. Flange spigot or socket pieces - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 600 - 675mm |
| 096013(I)J | Supply D.I. Flange spigot or socket pieces - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 700 - 750 mm |
| 096013(I)K | Supply D.I. Flange spigot or socket pieces - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 800 mm |
| 096013(I)L | Supply D.I. Flange spigot or socket pieces - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 900 mm |
| 096013(I)M | Supply D.I. Flange spigot or socket pieces - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 1000 - 1100 mm |
| 096013(I)N | Supply D.I. Flange spigot or socket pieces - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 1200 mm |
| 096013(II)A | Supply D.I. Flange spigot or socket pieces - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 80mm & under |
| 096013(II)B | Supply D.I. Flange spigot or socket pieces - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 100 mm |
| 096013(II)C | Supply D.I. Flange spigot or socket pieces - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 125 -150 mm |
| 096013(II)D | Supply D.I. Flange spigot or socket pieces - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 200 mm |
| 096013(II)E | Supply D.I. Flange spigot or socket pieces - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 250 mm |
| 096013(II)F | Supply D.I. Flange spigot or socket pieces - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 300 - 350 mm |
| 096013(II)G | Supply D.I. Flange spigot or socket pieces - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 400mm |
| 096013(II)H | Supply D.I. Flange spigot or socket pieces - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 450 - 525mm |
| 096013(II)I | Supply D.I. Flange spigot or socket pieces - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 600 - 675mm |
| 096013(II)J | Supply D.I. Flange spigot or socket pieces - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 700 - 750 mm |
| 096013(II)K | Supply D.I. Flange spigot or socket pieces - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 800 mm |
| 096013(II)L | Supply D.I. Flange spigot or socket pieces - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 900 mm |
| 096013(II)M | Supply D.I. Flange spigot or socket pieces - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 1000 - 1100 mm |
| 096013(II)N | Supply D.I. Flange spigot or socket pieces - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 1200 mm |
| 096014A | Supply D.I. Caps. Nominal diameter of pipe 80mm & under |
| 096014B | Supply D.I. Caps. Nominal diameter of pipe 100 mm |
| 096014C | Supply D.I. Caps. Nominal diameter of pipe 125 -150 mm |
| 096014D | Supply D.I. Caps. Nominal diameter of pipe 200 mm |
| 096014E | Supply D.I. Caps. Nominal diameter of pipe 250 mm |
| 096014F | Supply D.I. Caps. Nominal diameter of pipe 300 - 350 mm |
| 096014G | Supply D.I. Caps. Nominal diameter of pipe 400mm |
| 096014H | Supply D.I. Caps. Nominal diameter of pipe 450 - 525mm |
| 096014I | Supply D.I. Caps. Nominal diameter of pipe 600 - 675mm |
| 096015A | Supply D.I. blank flanges. Nominal diameter of pipe 80mm & under |
| 096015B | Supply D.I. blank flanges. Nominal diameter of pipe 100 mm |
| 096015C | Supply D.I. blank flanges. Nominal diameter of pipe 125 -150 mm |
| 096015D | Supply D.I. blank flanges. Nominal diameter of pipe 200 mm |
| 096015E | Supply D.I. blank flanges. Nominal diameter of pipe 250 mm |
| 096015F | Supply D.I. blank flanges. Nominal diameter of pipe 300 - 350 mm |
| 096015G | Supply D.I. blank flanges. Nominal diameter of pipe 400mm |
| 096015H | Supply D.I. blank flanges. Nominal diameter of pipe 450 - 525mm |
| 096015I | Supply D.I. blank flanges. Nominal diameter of pipe 600 - 675mm |
| 096016(I)A | Supply D.I. tees - double socket flange branch or all flange branch - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 80mm & under |
| 096016(I)B | Supply D.I. tees - double socket flange branch or all flange branch - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 100 mm |
| 096016(I)C | Supply D.I. tees - double socket flange branch or all flange branch - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 125 -150 mm |
| 096016(I)D | Supply D.I. tees - double socket flange branch or all flange branch - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 200 mm |
| 096016(I)E | Supply D.I. tees - double socket flange branch or all flange branch - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 250 mm |
| 096016(I)F | Supply D.I. tees - double socket flange branch or all flange branch - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 300 - 350 mm |
| 096016(I)G | Supply D.I. tees - double socket flange branch or all flange branch - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 400mm |
| 096016(I)H | Supply D.I. tees - double socket flange branch or all flange branch - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 450 - 525mm |
| 096016(I)I | Supply D.I. tees - double socket flange branch or all flange branch - refer to fittings with the epoxy coating respective1y as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 600 - 675mm |
| 096016(II)A | Supply D.I. tees - double socket flange branch or all flange branch - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 80mm & under |
| 096016(II)B | Supply D.I. tees - double socket flange branch or all flange branch - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 100 mm |
| 096016(II)C | Supply D.I. tees - double socket flange branch or all flange branch - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 125 -150 mm |
| 096016(II)D | Supply D.I. tees - double socket flange branch or all flange branch - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 200 mm |
| 096016(II)E | Supply D.I. tees - double socket flange branch or all flange branch - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 250 mm |
| 096016(II)F | Supply D.I. tees - double socket flange branch or all flange branch - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 300 - 350 mm |
| 096016(II)G | Supply D.I. tees - double socket flange branch or all flange branch - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 400mm |
| 096016(II)H | Supply D.I. tees - double socket flange branch or all flange branch - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 450 - 525mm |
| 096016(II)I | Supply D.I. tees - double socket flange branch or all flange branch - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 600 - 675mm |
| 096017B | Supply Copper alloy gate valves. Nominal diameter of pipe 20 mm |
| 096017C | Supply Copper alloy gate valves. Nominal diameter of pipe 25 mm |
| 096017D | Supply Copper alloy gate valves. Nominal diameter of pipe 40 mm |
| 096017E | Supply Copper alloy gate valves. Nominal diameter of pipe 50 mm |
| 096017F | Supply Copper alloy gate valves. Nominal diameter of pipe 80 mm |
| 096017G | Supply Copper alloy gate valves. Nominal diameter of pipe 100 mm |
| 096018C | Supply Single air relief valves. Nominal diameter of pipe 25 mm |
| 096019E | Supply Double air relief valves. Nominal diameter of pipe 50 mm |
| 096019F | Supply Double air relief valves. Nominal diameter of pipe 80 mm |
| 096019G | Supply Double air relief valves. Nominal diameter of pipe 100 mm |
| 096019H | Supply Double air relief valves. Nominal diameter of pipe 150 mm |
| 096020A | Supply Brass stopcock. Nominal diameter of pipe 15 mm |
| 096020B | Supply Brass stopcock. Nominal diameter of pipe 20 mm |
| 096020C | Supply Brass stopcock. Nominal diameter of pipe 25 mm |
| 096020D | Supply Brass stopcock. Nominal diameter of pipe 40 mm |
| 096020E | Supply Brass stopcock. Nominal diameter of pipe 50 mm |
| 096021B | Supply U.P.V.C. pipes with socket end. Nominal diameter of pipe 20 mm |
| 096021C | Supply U.P.V.C. pipes with socket end. Nominal diameter of pipe 25 mm |
| 096021D | Supply U.P.V.C. pipes with socket end. Nominal diameter of pipe 40 mm |
| 096021E | Supply U.P.V.C. pipes with socket end. Nominal diameter of pipe 50 mm |
| 096021F | Supply U.P.V.C. pipes with socket end. Nominal diameter of pipe 80 mm |
| 096021G | Supply U.P.V.C. pipes with socket end. Nominal diameter of pipe 100 mm |
| 096021H | Supply U.P.V.C. pipes with socket end. Nominal diameter of pipe 150 mm |
| 096021I | Supply U.P.V.C. pipes with socket end. Nominal diameter of pipe 200 mm |
| 096021J | Supply U.P.V.C. pipes with socket end. Nominal diameter of pipe 250 mm |
| 096022B | Supply U.P.V.C. pipe bends and elbows to any angle. Nominal diameter of pipe 20 mm |
| 096022C | Supply U.P.V.C. pipe bends and elbows to any angle. Nominal diameter of pipe 25 mm |
| 096022D | Supply U.P.V.C. pipe bends and elbows to any angle. Nominal diameter of pipe 40 mm |
| 096022E | Supply U.P.V.C. pipe bends and elbows to any angle. Nominal diameter of pipe 50 mm |
| 096022F | Supply U.P.V.C. pipe bends and elbows to any angle. Nominal diameter of pipe 80 mm |
| 096022G | Supply U.P.V.C. pipe bends and elbows to any angle. Nominal diameter of pipe 100 mm |
| 096022H | Supply U.P.V.C. pipe bends and elbows to any angle. Nominal diameter of pipe 150 mm |
| 096022I | Supply U.P.V.C. pipe bends and elbows to any angle. Nominal diameter of pipe 200 mm |
| 096022J | Supply U.P.V.C. pipe bends and elbows to any angle. Nominal diameter of pipe 250 mm |
| 096023B | Supply U.P.V.C. caps with socket end. Nominal diameter of pipe 20 mm |
| 096023C | Supply U.P.V.C. caps with socket end. Nominal diameter of pipe 25 mm |
| 096023D | Supply U.P.V.C. caps with socket end. Nominal diameter of pipe 40 mm |
| 096023E | Supply U.P.V.C. caps with socket end. Nominal diameter of pipe 50 mm |
| 096023F | Supply U.P.V.C. caps with socket end. Nominal diameter of pipe 80 mm |
| 096023G | Supply U.P.V.C. caps with socket end. Nominal diameter of pipe 100 mm |
| 096023H | Supply U.P.V.C. caps with socket end. Nominal diameter of pipe 150 mm |
| 096023I | Supply U.P.V.C. caps with socket end. Nominal diameter of pipe 200 mm |
| 096023J | Supply U.P.V.C. caps with socket end. Nominal diameter of pipe 250 mm |
| 096024B | Supply U.P.V.C. tees. Nominal diameter of pipe 20 mm |
| 096024C | Supply U.P.V.C. tees. Nominal diameter of pipe 25 mm |
| 096024D | Supply U.P.V.C. tees. Nominal diameter of pipe 40 mm |
| 096024E | Supply U.P.V.C. tees. Nominal diameter of pipe 50 mm |
| 096024F | Supply U.P.V.C. tees. Nominal diameter of pipe 80 mm |
| 096024G | Supply U.P.V.C. tees. Nominal diameter of pipe 100 mm |
| 096024H | Supply U.P.V.C. tees. Nominal diameter of pipe 150 mm |
| 096024I | Supply U.P.V.C. tees. Nominal diameter of pipe 200 mm |
| 096024J | Supply U.P.V.C. tees. Nominal diameter of pipe 250 mm |
| 096025B | Supply U.P.V.C. sockets. Nominal diameter of pipe 20 mm |
| 096025C | Supply U.P.V.C. sockets. Nominal diameter of pipe 25 mm |
| 096025D | Supply U.P.V.C. sockets. Nominal diameter of pipe 40 mm |
| 096025E | Supply U.P.V.C. sockets. Nominal diameter of pipe 50 mm |
| 096025F | Supply U.P.V.C. sockets. Nominal diameter of pipe 80 mm |
| 096025G | Supply U.P.V.C. sockets. Nominal diameter of pipe 100 mm |
| 096025H | Supply U.P.V.C. sockets. Nominal diameter of pipe 150 mm |
| 096025I | Supply U.P.V.C. sockets. Nominal diameter of pipe 200 mm |
| 096025J | Supply U.P.V.C. sockets. Nominal diameter of pipe 250 mm |
| 096026C | Supply U.P.V.C. tee reducers or socket reducers. Nominal diameter of pipe 25 mm |
| 096026D | Supply U.P.V.C. tee reducers or socket reducers. Nominal diameter of pipe 40 mm |
| 096026E | Supply U.P.V.C. tee reducers or socket reducers. Nominal diameter of pipe 50 mm |
| 096026F | Supply U.P.V.C. tee reducers or socket reducers. Nominal diameter of pipe 80 mm |
| 096026G | Supply U.P.V.C. tee reducers or socket reducers. Nominal diameter of pipe 100 mm |
| 096026H | Supply U.P.V.C. tee reducers or socket reducers. Nominal diameter of pipe 150 mm |
| 096026I | Supply U.P.V.C. tee reducers or socket reducers. Nominal diameter of pipe 200 mm |
| 096026J | Supply U.P.V.C. tee reducers or socket reducers. Nominal diameter of pipe 250 mm |
| 096027E | Supply U.P.V.C. flange assemblies (stub flanges). Nominal diameter of pipe 50 mm |
| 096027F | Supply U.P.V.C. flange assemblies (stub flanges). Nominal diameter of pipe 80 mm |
| 096027G | Supply U.P.V.C. flange assemblies (stub flanges). Nominal diameter of pipe 100 mm |
| 096027H | Supply U.P.V.C. flange assemblies (stub flanges). Nominal diameter of pipe 150 mm |
| 096027I | Supply U.P.V.C. flange assemblies (stub flanges). Nominal diameter of pipe 200 mm |
| 096027J | Supply U.P.V.C. flange assemblies (stub flanges). Nominal diameter of pipe 250 mm |
| 096028B | Supply U.P.V.C. socket valves (nipple adaptors). Nominal diameter of pipe 20 mm |
| 096028C | Supply U.P.V.C. socket valves (nipple adaptors). Nominal diameter of pipe 25 mm |
| 096028D | Supply U.P.V.C. socket valves (nipple adaptors). Nominal diameter of pipe 40 mm |
| 096028E | Supply U.P.V.C. socket valves (nipple adaptors). Nominal diameter of pipe 50 mm |
| 096028F | Supply U.P.V.C. socket valves (nipple adaptors). Nominal diameter of pipe 80 mm |
| 096028G | Supply U.P.V.C. socket valves (nipple adaptors). Nominal diameter of pipe 100 mm |
| 096028H | Supply U.P.V.C. socket valves (nipple adaptors). Nominal diameter of pipe 150 mm |
| 096028I | Supply U.P.V.C. socket valves (nipple adaptors). Nominal diameter of pipe 200 mm |
| 096028J | Supply U.P.V.C. socket valves (nipple adaptors). Nominal diameter of pipe 250 mm |
| 096029B | Supply U.P.V.C. repair couplings (simple joint). Nominal diameter of pipe 20 mm |
| 096029C | Supply U.P.V.C. repair couplings (simple joint). Nominal diameter of pipe 25 mm |
| 096029D | Supply U.P.V.C. repair couplings (simple joint). Nominal diameter of pipe 40 mm |
| 096029E | Supply U.P.V.C. repair couplings (simple joint). Nominal diameter of pipe 50 mm |
| 096030F | Supply C.I. repair couplings (dresser joint). Nominal diameter of pipe 80 mm |
| 096030G | Supply C.I. repair couplings (dresser joint). Nominal diameter of pipe 100 mm |
| 096031E | Supply C.I. flanges - screwed for pipes. Nominal diameter of pipe 50 mm |
| 096031F | Supply C.I. flanges - screwed for pipes. Nominal diameter of pipe 80 mm |
| 096031G | Supply C.I. flanges - screwed for pipes. Nominal diameter of pipe 100 mm |
| 096031H | Supply C.I. flanges - screwed for pipes. Nominal diameter of pipe 150 mm |
| 096032B | Supply Copper alloy longscrews. Nominal diameter of pipe 20 mm |
| 096032C | Supply Copper alloy longscrews. Nominal diameter of pipe 25 mm |
| 096032D | Supply Copper alloy longscrews. Nominal diameter of pipe 40 mm |
| 096032E | Supply Copper alloy longscrews. Nominal diameter of pipe 50 mm |
| 096032F | Supply Copper alloy longscrews. Nominal diameter of pipe 80 mm |
| 096032G | Supply Copper alloy longscrews. Nominal diameter of pipe 100 mm |
| 096033B | Supply Lined G.I. tees. Nominal diameter of pipe 20 mm |
| 096033C | Supply Lined G.I. tees. Nominal diameter of pipe 25 mm |
| 096033D | Supply Lined G.I. tees. Nominal diameter of pipe 40 mm |
| 096033E | Supply Lined G.I. tees. Nominal diameter of pipe 50 mm |
| 096033F | Supply Lined G.I. tees. Nominal diameter of pipe 80 mm |
| 096033G | Supply Lined G.I. tees. Nominal diameter of pipe 100 mm |
| 096034B | Supply Lined G.I. nipples. Nominal diameter of pipe 20 mm |
| 096034C | Supply Lined G.I. nipples. Nominal diameter of pipe 25 mm |
| 096034D | Supply Lined G.I. nipples. Nominal diameter of pipe 40 mm |
| 096034E | Supply Lined G.I. nipples. Nominal diameter of pipe 50 mm |
| 096034F | Supply Lined G.I. nipples. Nominal diameter of pipe 80 mm |
| 096034G | Supply Lined G.I. nipples. Nominal diameter of pipe 100 mm |
| 096035B | Supply Lined G.I. pipe bends and elbows to any angle. Nominal diameter of pipe 20 mm |
| 096035C | Supply Lined G.I. pipe bends and elbows to any angle. Nominal diameter of pipe 25 mm |
| 096035D | Supply Lined G.I. pipe bends and elbows to any angle. Nominal diameter of pipe 40 mm |
| 096035E | Supply Lined G.I. pipe bends and elbows to any angle. Nominal diameter of pipe 50 mm |
| 096035F | Supply Lined G.I. pipe bends and elbows to any angle. Nominal diameter of pipe 80 mm |
| 096035G | Supply Lined G.I. pipe bends and elbows to any angle. Nominal diameter of pipe 100 mm |
| 096036B | Supply Lined G.I. stop ends and plugs. Nominal diameter of pipe 20 mm |
| 096036C | Supply Lined G.I. stop ends and plugs. Nominal diameter of pipe 25 mm |
| 096036D | Supply Lined G.I. stop ends and plugs. Nominal diameter of pipe 40 mm |
| 096036E | Supply Lined G.I. stop ends and plugs. Nominal diameter of pipe 50 mm |
| 096036F | Supply Lined G.I. stop ends and plugs. Nominal diameter of pipe 80 mm |
| 096036G | Supply Lined G.I. stop ends and plugs. Nominal diameter of pipe 100 mm |
| 096037A | Supply Screw jointed valves or stopcocks other than item nos. 096/017 to 096/020. Nominal diameter of pipe 15 mm |
| 096037B | Supply Screw jointed valves or stopcocks other than item nos. 096/017 to 096/020. Nominal diameter of pipe 20 mm |
| 096037C | Supply Screw jointed valves or stopcocks other than item nos. 096/017 to 096/020. Nominal diameter of pipe 25 mm |
| 096037D | Supply Screw jointed valves or stopcocks other than item nos. 096/017 to 096/020. Nominal diameter of pipe 40 mm |
| 096037E | Supply Screw jointed valves or stopcocks other than item nos. 096/017 to 096/020. Nominal diameter of pipe 50 mm |
| 096037F | Supply Screw jointed valves or stopcocks other than item nos. 096/017 to 096/020. Nominal diameter of pipe 80 mm |
| 096037G | Supply Screw jointed valves or stopcocks other than item nos. 096/017 to 096/020. Nominal diameter of pipe 100 mm |
| 096038B | Supply Lined G.I. sockets. Nominal diameter of pipe 20 mm |
| 096038C | Supply Lined G.I. sockets. Nominal diameter of pipe 25 mm |
| 096038D | Supply Lined G.I. sockets. Nominal diameter of pipe 40 mm |
| 096038E | Supply Lined G.I. sockets. Nominal diameter of pipe 50 mm |
| 096038F | Supply Lined G.I. sockets. Nominal diameter of pipe 80 mm |
| 096038G | Supply Lined G.I. sockets. Nominal diameter of pipe 100 mm |
| 096039B | Supply Lined G.I. socket reducers, tee reducers or bush reducers. Nominal diameter of pipe 20 mm |
| 096039C | Supply Lined G.I. socket reducers, tee reducers or bush reducers. Nominal diameter of pipe 25 mm |
| 096039D | Supply Lined G.I. socket reducers, tee reducers or bush reducers. Nominal diameter of pipe 40 mm |
| 096039E | Supply Lined G.I. socket reducers, tee reducers or bush reducers. Nominal diameter of pipe 50 mm |
| 096039F | Supply Lined G.I. socket reducers, tee reducers or bush reducers. Nominal diameter of pipe 80 mm |
| 096039G | Supply Lined G.I. socket reducers, tee reducers or bush reducers. Nominal diameter of pipe 100 mm |
| 096040B | Supply G.I. repair couplings (simple joint). Nominal diameter of pipe 20 mm |
| 096040C | Supply G.I. repair couplings (simple joint). Nominal diameter of pipe 25 mm |
| 096040D | Supply G.I. repair couplings (simple joint). Nominal diameter of pipe 40 mm |
| 096040E | Supply G.I. repair couplings (simple joint). Nominal diameter of pipe 50 mm |
| 096041B | Supply PE pipe bends and elbows to any angle. Nominal diameter of pipe 20 mm |
| 096041C | Supply PE pipe bends and elbows to any angle. Nominal diameter of pipe 25 mm |
| 096041D | Supply PE pipe bends and elbows to any angle. Nominal diameter of pipe 40 mm |
| 096041E | Supply PE pipe bends and elbows to any angle. Nominal diameter of pipe 50 mm |
| 096041F | Supply PE pipe bends and elbows to any angle. Nominal diameter of pipe 80 mm |
| 096041G | Supply PE pipe bends and elbows to any angle. Nominal diameter of pipe 100 mm |
| 096041H | Supply PE pipe bends and elbows to any angle. Nominal diameter of pipe 150 mm |
| 096041I | Supply PE pipe bends and elbows to any angle. Nominal diameter of pipe 200 mm |
| 096041J | Supply PE pipe bends and elbows to any angle. Nominal diameter of pipe 250 mm |
| 096041K | Supply PE pipe bends and elbows to any angle. Nominal diameter of pipe 300 mm |
| 096042B | Supply PE pipe couplers Nominal diameter of pipe 20 mm |
| 096042C | Supply PE pipe couplers Nominal diameter of pipe 25 mm |
| 096042D | Supply PE pipe couplers Nominal diameter of pipe 40 mm |
| 096042E | Supply PE pipe couplers Nominal diameter of pipe 50 mm |
| 096042F | Supply PE pipe couplers Nominal diameter of pipe 80 mm |
| 096042G | Supply PE pipe couplers Nominal diameter of pipe 100 mm |
| 096042H | Supply PE pipe couplers Nominal diameter of pipe 150 mm |
| 096042I | Supply PE pipe couplers Nominal diameter of pipe 200 mm |
| 096042J | Supply PE pipe couplers Nominal diameter of pipe 250 mm |
| 096042K | Supply PE pipe couplers Nominal diameter of pipe 300 mm |
| 096042L | Supply PE pipe couplers Nominal diameter of pipe 400 mm |
| 096042M | Supply PE pipe couplers Nominal diameter of pipe 450 - 525 mm |
| 096042N | Supply PE pipe couplers Nominal diameter of pipe 600 - 675 mm |
| 096043B | Supply PE tees - equal or unequal. Nominal diameter of pipe 20 mm |
| 096043C | Supply PE tees - equal or unequal. Nominal diameter of pipe 25 mm |
| 096043D | Supply PE tees - equal or unequal. Nominal diameter of pipe 40 mm |
| 096043E | Supply PE tees - equal or unequal. Nominal diameter of pipe 50 mm |
| 096043F | Supply PE tees - equal or unequal. Nominal diameter of pipe 80 mm |
| 096043G | Supply PE tees - equal or unequal. Nominal diameter of pipe 100 mm |
| 096043H | Supply PE tees - equal or unequal. Nominal diameter of pipe 150 mm |
| 096043I | Supply PE tees - equal or unequal. Nominal diameter of pipe 200 mm |
| 096043J | Supply PE tees - equal or unequal. Nominal diameter of pipe 250 mm |
| 096043K | Supply PE tees - equal or unequal. Nominal diameter of pipe 300 mm |
| 096044B | Supply PE caps with socket end. Nominal diameter of pipe 20 mm |
| 096044C | Supply PE caps with socket end. Nominal diameter of pipe 25 mm |
| 096044D | Supply PE caps with socket end. Nominal diameter of pipe 40 mm |
| 096044E | Supply PE caps with socket end. Nominal diameter of pipe 50 mm |
| 096044F | Supply PE caps with socket end. Nominal diameter of pipe 80 mm |
| 096044G | Supply PE caps with socket end. Nominal diameter of pipe 100 mm |
| 096044H | Supply PE caps with socket end. Nominal diameter of pipe 150 mm |
| 096044I | Supply PE caps with socket end. Nominal diameter of pipe 200 mm |
| 096044J | Supply PE caps with socket end. Nominal diameter of pipe 250 mm |
| 096044K | Supply PE caps with socket end. Nominal diameter of pipe 300 mm |
| 096045E | Supply PE stub flanges PE/FL end. Nominal diameter of pipe 50 mm |
| 096045F | Supply PE stub flanges PE/FL end. Nominal diameter of pipe 80 mm |
| 096045G | Supply PE stub flanges PE/FL end. Nominal diameter of pipe 100 mm |
| 096045H | Supply PE stub flanges PE/FL end. Nominal diameter of pipe 150 mm |
| 096045I | Supply PE stub flanges PE/FL end. Nominal diameter of pipe 200 mm |
| 096045J | Supply PE stub flanges PE/FL end. Nominal diameter of pipe 250 mm |
| 096045K | Supply PE stub flanges PE/FL end. Nominal diameter of pipe 300 mm |
| 096045L | Supply PE stub flanges PE/FL end Nominal diameter of pipe 400 mm |
| 096045M | Supply PE stub flanges PE/FL end Nominal diameter of pipe 450 - 525 mm |
| 096045N | Supply PE stub flanges PE/FL end Nominal diameter of pipe 600 - 675 mm |
| 096046C | Supply PE saddles, self-tapping on pressurised water main. Nominal diameter of pipe 25 mm |
| 096046D | Supply PE saddles, self-tapping on pressurised water main. Nominal diameter of pipe 40 mm |
| 096046E | Supply PE saddles, self-tapping on pressurised water main. Nominal diameter of pipe 50 mm |
| 096046F | Supply PE saddles, self-tapping on pressurised water main. Nominal diameter of pipe 80 mm |
| 096046G | Supply PE saddles, self-tapping on pressurised water main. Nominal diameter of pipe 100 mm |
| 096046H | Supply PE saddles, self-tapping on pressurised water main. Nominal diameter of pipe 150 mm |
| 096046I | Supply PE saddles, self-tapping on pressurised water main. Nominal diameter of pipe 200 mm |
| 096046J | Supply PE saddles, self-tapping on pressurised water main. Nominal diameter of pipe 250 mm |
| 096046K | Supply PE saddles, self-tapping on pressurised water main. Nominal diameter of pipe 300 mm |
| 096047(I)B | Supply U.P.V.C. Lined stainless steel tees. Nominal diameter of pipe 20 mm |
| 096047(I)C | Supply U.P.V.C. Lined stainless steel tees. Nominal diameter of pipe 25 mm |
| 096047(I)D | Supply U.P.V.C. Lined stainless steel tees. Nominal diameter of pipe 40 mm |
| 096047(I)E | Supply U.P.V.C. Lined stainless steel tees. Nominal diameter of pipe 50 mm |
| 096047(I)F | Supply U.P.V.C. Lined stainless steel tees. Nominal diameter of pipe 80 mm |
| 096047(I)G | Supply U.P.V.C. Lined stainless steel tees. Nominal diameter of pipe 100 mm |
| 096047(I)H | Supply U.P.V.C. Lined stainless steel tees. Nominal diameter of pipe 150 mm |
| 096047(I)I | Supply U.P.V.C. Lined stainless steel tees. Nominal diameter of pipe 200 mm |
| 096047(II)B | Supply Stainless steel tees. Nominal diameter of pipe 20 mm |
| 096047(II)C | Supply Stainless steel tees. Nominal diameter of pipe 25 mm |
| 096047(II)D | Supply Stainless steel tees. Nominal diameter of pipe 40 mm |
| 096047(II)E | Supply Stainless steel tees. Nominal diameter of pipe 50 mm |
| 096047(II)F | Supply Stainless steel tees. Nominal diameter of pipe 80 mm |
| 096047(II)G | Supply Stainless steel tees. Nominal diameter of pipe 100 mm |
| 096047(II)H | Supply Stainless steel tees. Nominal diameter of pipe 150 mm |
| 096047(II)I | Supply Stainless steel tees. Nominal diameter of pipe 200 mm |
| 096048(I)B | Supply U.P.V.C. Lined stainless steel nipples. Nominal diameter of pipe 20 mm |
| 096048(I)C | Supply U.P.V.C. Lined stainless steel nipples. Nominal diameter of pipe 25 mm |
| 096048(I)D | Supply U.P.V.C. Lined stainless steel nipples. Nominal diameter of pipe 40 mm |
| 096048(I)E | Supply U.P.V.C. Lined stainless steel nipples. Nominal diameter of pipe 50 mm |
| 096048(I)F | Supply U.P.V.C. Lined stainless steel nipples. Nominal diameter of pipe 80 mm |
| 096048(I)G | Supply U.P.V.C. Lined stainless steel nipples. Nominal diameter of pipe 100 mm |
| 096048(I)H | Supply U.P.V.C. Lined stainless steel nipples. Nominal diameter of pipe 150 mm |
| 096048(I)I | Supply U.P.V.C. Lined stainless steel nipples. Nominal diameter of pipe 200 mm |
| 096048(II)B | Supply Stainless steel nipples. Nominal diameter of pipe 20 mm |
| 096048(II)C | Supply Stainless steel nipples. Nominal diameter of pipe 25 mm |
| 096048(II)D | Supply Stainless steel nipples. Nominal diameter of pipe 40 mm |
| 096048(II)E | Supply Stainless steel nipples. Nominal diameter of pipe 50 mm |
| 096048(II)F | Supply Stainless steel nipples. Nominal diameter of pipe 80 mm |
| 096048(II)G | Supply Stainless steel nipples. Nominal diameter of pipe 100 mm |
| 096048(II)H | Supply Stainless steel nipples. Nominal diameter of pipe 150 mm |
| 096048(II)I | Supply Stainless steel nipples. Nominal diameter of pipe 200 mm |
| 096049(I)B | Supply U.P.V.C. Lined stainless steel pipe bends and elbows to any angle. Nominal diameter of pipe 20 mm |
| 096049(I)C | Supply U.P.V.C. Lined stainless steel pipe bends and elbows to any angle. Nominal diameter of pipe 25 mm |
| 096049(I)D | Supply U.P.V.C. Lined stainless steel pipe bends and elbows to any angle. Nominal diameter of pipe 40 mm |
| 096049(I)E | Supply U.P.V.C. Lined stainless steel pipe bends and elbows to any angle. Nominal diameter of pipe 50 mm |
| 096049(I)F | Supply U.P.V.C. Lined stainless steel pipe bends and elbows to any angle. Nominal diameter of pipe 80 mm |
| 096049(I)G | Supply U.P.V.C. Lined stainless steel pipe bends and elbows to any angle. Nominal diameter of pipe 100 mm |
| 096049(I)H | Supply U.P.V.C. Lined stainless steel pipe bends and elbows to any angle. Nominal diameter of pipe 150 mm |
| 096049(I)I | Supply U.P.V.C. Lined stainless steel pipe bends and elbows to any angle. Nominal diameter of pipe 200 mm |
| 096049(II)B | Supply Stainless steel pipe bends and elbows to any angle. Nominal diameter of pipe 20 mm |
| 096049(II)C | Supply Stainless steel pipe bends and elbows to any angle. Nominal diameter of pipe 25 mm |
| 096049(II)D | Supply Stainless steel pipe bends and elbows to any angle. Nominal diameter of pipe 40 mm |
| 096049(II)E | Supply Stainless steel pipe bends and elbows to any angle. Nominal diameter of pipe 50 mm |
| 096049(II)F | Supply Stainless steel pipe bends and elbows to any angle. Nominal diameter of pipe 80 mm |
| 096049(II)G | Supply Stainless steel pipe bends and elbows to any angle. Nominal diameter of pipe 100 mm |
| 096049(II)H | Supply Stainless steel pipe bends and elbows to any angle. Nominal diameter of pipe 150 mm |
| 096049(II)I | Supply Stainless steel pipe bends and elbows to any angle. Nominal diameter of pipe 200 mm |
| 096050(I)B | Supply U.P.V.C. Lined stainless steel stop ends and plugs. Nominal diameter of pipe 20 mm |
| 096050(I)C | Supply U.P.V.C. Lined stainless steel stop ends and plugs. Nominal diameter of pipe 25 mm |
| 096050(I)D | Supply U.P.V.C. Lined stainless steel stop ends and plugs. Nominal diameter of pipe 40 mm |
| 096050(I)E | Supply U.P.V.C. Lined stainless steel stop ends and plugs. Nominal diameter of pipe 50 mm |
| 096050(I)F | Supply U.P.V.C. Lined stainless steel stop ends and plugs. Nominal diameter of pipe 80 mm |
| 096050(I)G | Supply U.P.V.C. Lined stainless steel stop ends and plugs. Nominal diameter of pipe 100 mm |
| 096050(I)H | Supply U.P.V.C. Lined stainless steel stop ends and plugs. Nominal diameter of pipe 150 mm |
| 096050(I)I | Supply U.P.V.C. Lined stainless steel stop ends and plugs. Nominal diameter of pipe 200 mm |
| 096050(II)B | Supply Stainless steel stop ends and plugs. Nominal diameter of pipe 20 mm |
| 096050(II)C | Supply Stainless steel stop ends and plugs. Nominal diameter of pipe 25 mm |
| 096050(II)D | Supply Stainless steel stop ends and plugs. Nominal diameter of pipe 40 mm |
| 096050(II)E | Supply Stainless steel stop ends and plugs. Nominal diameter of pipe 50 mm |
| 096050(II)F | Supply Stainless steel stop ends and plugs. Nominal diameter of pipe 80 mm |
| 096050(II)G | Supply Stainless steel stop ends and plugs. Nominal diameter of pipe 100 mm |
| 096050(II)H | Supply Stainless steel stop ends and plugs. Nominal diameter of pipe 150 mm |
| 096050(II)I | Supply Stainless steel stop ends and plugs. Nominal diameter of pipe 200 mm |
| 096051(I)B | Supply U.P.V.C. Lined stainless steel sockets. Nominal diameter of pipe 20 mm |
| 096051(I)C | Supply U.P.V.C. Lined stainless steel sockets. Nominal diameter of pipe 25 mm |
| 096051(I)D | Supply U.P.V.C. Lined stainless steel sockets. Nominal diameter of pipe 40 mm |
| 096051(I)E | Supply U.P.V.C. Lined stainless steel sockets. Nominal diameter of pipe 50 mm |
| 096051(I)F | Supply U.P.V.C. Lined stainless steel sockets. Nominal diameter of pipe 80 mm |
| 096051(I)G | Supply U.P.V.C. Lined stainless steel sockets. Nominal diameter of pipe 100 mm |
| 096051(I)H | Supply U.P.V.C. Lined stainless steel sockets. Nominal diameter of pipe 150 mm |
| 096051(I)I | Supply U.P.V.C. Lined stainless steel sockets. Nominal diameter of pipe 200 mm |
| 096051(II)B | Supply Stainless steel sockets. Nominal diameter of pipe 20 mm |
| 096051(II)C | Supply Stainless steel sockets. Nominal diameter of pipe 25 mm |
| 096051(II)D | Supply Stainless steel sockets. Nominal diameter of pipe 40 mm |
| 096051(II)E | Supply Stainless steel sockets. Nominal diameter of pipe 50 mm |
| 096051(II)F | Supply Stainless steel sockets. Nominal diameter of pipe 80 mm |
| 096051(II)G | Supply Stainless steel sockets. Nominal diameter of pipe 100 mm |
| 096051(II)H | Supply Stainless steel sockets. Nominal diameter of pipe 150 mm |
| 096051(II)I | Supply Stainless steel sockets. Nominal diameter of pipe 200 mm |
| 096052B | Supply Compression fittings for PE pipes - male or female adaptor or compression coupling. Nominal diameter of pipe 20 mm |
| 096052C | Supply Compression fittings for PE pipes - male or female adaptor or compression coupling. Nominal diameter of pipe 25 mm |
| 096052D | Supply Compression fittings for PE pipes - male or female adaptor or compression coupling. Nominal diameter of pipe 40 mm |
| 096052E | Supply Compression fittings for PE pipes - male or female adaptor or compression coupling. Nominal diameter of pipe 50 mm |
| 096053F | Supply Mechanical fittings for PE pipes - mechanical coupling or flange adaptor. Nominal diameter of pipe 80 mm |
| 096053G | Supply Mechanical fittings for PE pipes - mechanical coupling or flange adaptor. Nominal diameter of pipe 100 mm |
| 096053H | Supply Mechanical fittings for PE pipes - mechanical coupling or flange adaptor. Nominal diameter of pipe 150 mm |
| 096053I | Supply Mechanical fittings for PE pipes - mechanical coupling or flange adaptor. Nominal diameter of pipe 200 mm |
| 096053J | Supply Mechanical fittings for PE pipes - mechanical coupling or flange adaptor. Nominal diameter of pipe 250 mm |
| 096053K | Supply Mechanical fittings for PE pipes - mechanical coupling or flange adaptor. Nominal diameter of pipe 300 mm |
| 096053L | Supply Mechanical fittings for PE pipes - mechanical coupling or flange adaptor. Nominal diameter of pipe 400 mm |
| 096053M | Supply Mechanical fittings for PE pipes - mechanical coupling or flange adaptor. Nominal diameter of pipe 450 - 525 mm |
| 096053N | Supply Mechanical fittings for PE pipes - mechanical coupling or flange adaptor. Nominal diameter of pipe 600 - 675 mm |
| 096054C | Supply PE reducers with socket ends. Nominal diameter of pipe 25 mm |
| 096054D | Supply PE reducers with socket ends. Nominal diameter of pipe 40 mm |
| 096054E | Supply PE reducers with socket ends. Nominal diameter of pipe 50 mm |
| 096054F | Supply PE reducers with socket ends. Nominal diameter of pipe 80 mm |
| 096054G | Supply PE reducers with socket ends. Nominal diameter of pipe 100 mm |
| 096054H | Supply PE reducers with socket ends. Nominal diameter of pipe 150 mm |
| 096055C | Supply Stainless steel standpipes for installation of single air valve. Nominal diameter of pipe 25 mm |
| 096055E | Supply Stainless steel standpipes for installation of single air valve. Nominal diameter of pipe 50 mm |
| 096056A | Supply Collars, change collars or flange adaptors for D.I. pipes. Nominal diameter of pipe 80mm & under |
| 096056B | Supply Collars, change collars or flange adaptors for D.I. pipes. Nominal diameter of pipe 100mm |
| 096056C | Supply Collars, change collars or flange adaptors for D.I. pipes. Nominal diameter of pipe 125 -150mm |
| 096056D | Supply Collars, change collars or flange adaptors for D.I. pipes. Nominal diameter of pipe 200mm |
| 096056E | Supply Collars, change collars or flange adaptors for D.I. pipes. Nominal diameter of pipe 250mm |
| 096056F | Supply Collars, change collars or flange adaptors for D.I. pipes. Nominal diameter of pipe 300 - 350mm |
| 096056G | Supply Collars, change collars or flange adaptors for D.I. pipes. Nominal diameter of pipe 400mm |
| 096056H | Supply Collars, change collars or flange adaptors for D.I. pipes. Nominal diameter of pipe 450 - 525mm |
| 096056I | Supply Collars, change collars or flange adaptors for D.I. pipes. Nominal diameter of pipe 600 - 675mm |
| 096057(I)G | Supply Steel collars - 'split type' - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 400mm |
| 096057(I)H | Supply Steel collars - 'split type' - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 450 - 525mm |
| 096057(I)I | Supply Steel collars - 'split type' - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 600 - 675mm |
| 096057(I)J | Supply Steel collars - 'split type' - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 700 - 750mm |
| 096057(I)K | Supply Steel collars - 'split type' - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 800 mm |
| 096057(I)L | Supply Steel collars - 'split type' - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 900 mm |
| 096057(I)M | Supply Steel collars - 'split type' - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 1000 - 1100 mm |
| 096057(I)N | Supply Steel collars - 'split type' - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 1200 mm |
| 096057(I)O | Supply Steel collars - 'split type' - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 1350 - 1400 mm |
| 096057(I)P | Supply Steel collars - 'split type' - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 1600 mm |
| 096057(I)Q | Supply Steel collars - 'split type' - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 1800 mm |
| 096057(I)R | Supply Steel collars - 'split type' - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 1950 - 2100 mm |
| 096057(I)S | Supply Steel collars - 'split type' - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 2200 mm |
| 096057(I)T | Supply Steel collars - 'split type' - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 2400 mm |
| 096057(II)G | Supply Steel collars - 'split type' - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 400mm |
| 096057(II)H | Supply Steel collars - 'split type' - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 450 - 525mm |
| 096057(II)I | Supply Steel collars - 'split type' - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 600 - 675mm |
| 096057(II)J | Supply Steel collars - 'split type' - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 700 - 750mm |
| 096057(II)K | Supply Steel collars - 'split type' - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 800 mm |
| 096057(II)L | Supply Steel collars - 'split type' - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 900 mm |
| 096057(II)M | Supply Steel collars - 'split type' - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 1000 - 1100 mm |
| 096057(II)N | Supply Steel collars - 'split type' - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 1200 mm |
| 096057(II)O | Supply Steel collars - 'split type' - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 1350 - 1400 mm |
| 096057(II)P | Supply Steel collars - 'split type' - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 1600 mm |
| 096057(II)Q | Supply Steel collars - 'split type' - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 1800 mm |
| 096057(II)R | Supply Steel collars - 'split type' - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 1950 - 2100 mm |
| 096057(II)S | Supply Steel collars - 'split type' - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 2200 mm |
| 096057(II)T | Supply Steel collars - 'split type' - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 2400 mm |
| 096058(I)C | Supply Slip-on type couplings for Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 125 -150mm |
| 096058(I)D | Supply Slip-on type couplings for Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 200mm |
| 096058(I)E | Supply Slip-on type couplings for Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 250mm |
| 096058(I)F | Supply Slip-on type couplings for Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 300 - 350mm |
| 096058(I)G | Supply Slip-on type couplings for Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 400mm |
| 096058(I)H | Supply Slip-on type couplings for Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 450 - 525mm |
| 096058(I)I | Supply Slip-on type couplings for Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 600 - 675mm |
| 096058(I)J | Supply Slip-on type couplings for Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 700 - 750mm |
| 096058(I)K | Supply Slip-on type couplings for Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 800 mm |
| 096058(I)L | Supply Slip-on type couplings for Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 900 mm |
| 096058(I)M | Supply Slip-on type couplings for Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 1000 - 1100 mm |
| 096058(I)N | Supply Slip-on type couplings for Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 1200 mm |
| 096058(I)O | Supply Slip-on type couplings for Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 1350 - 1400 mm |
| 096058(I)P | Supply Slip-on type couplings for Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 1600 mm |
| 096058(I)Q | Supply Slip-on type couplings for Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 1800 mm |
| 096058(I)R | Supply Slip-on type couplings for Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 1950 - 2100 mm |
| 096058(I)S | Supply Slip-on type couplings for Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 2200 mm |
| 096058(I)T | Supply Slip-on type couplings for Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 2400 mm |
| 096058(II)C | Supply Slip-on type couplings for Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 125 -150mm |
| 096058(II)D | Supply Slip-on type couplings for Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 200mm |
| 096058(II)E | Supply Slip-on type couplings for Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 250mm |
| 096058(II)F | Supply Slip-on type couplings for Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 300 - 350mm |
| 096058(II)G | Supply Slip-on type couplings for Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 400mm |
| 096058(II)H | Supply Slip-on type couplings for Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 450 - 525mm |
| 096058(II)I | Supply Slip-on type couplings for Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 600 - 675mm |
| 096058(II)J | Supply Slip-on type couplings for Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 700 - 750mm |
| 096058(II)K | Supply Slip-on type couplings for Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 800 mm |
| 096058(II)L | Supply Slip-on type couplings for Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 900 mm |
| 096058(II)M | Supply Slip-on type couplings for Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 1000 - 1100 mm |
| 096058(II)N | Supply Slip-on type couplings for Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 1200 mm |
| 096058(II)O | Supply Slip-on type couplings for Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 1350 - 1400 mm |
| 096058(II)P | Supply Slip-on type couplings for Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 1600 mm |
| 096058(II)Q | Supply Slip-on type couplings for Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 1800 mm |
| 096058(II)R | Supply Slip-on type couplings for Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 1950 - 2100 mm |
| 096058(II)S | Supply Slip-on type couplings for Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 2200 mm |
| 096058(II)T | Supply Slip-on type couplings for Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 2400 mm |
| 096058a(I)C | Supply Slip-on type couplings for steel pipes (PN 64). - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 125 -150mm |
| 096058a(I)D | Supply Slip-on type couplings for steel pipes (PN 64). - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 200mm |
| 096059(I)C | Supply Slip-on type flange adaptors for Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 125 -150mm |
| 096059(I)D | Supply Slip-on type flange adaptors for Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 200mm |
| 096059(I)E | Supply Slip-on type flange adaptors for Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 250mm |
| 096059(I)F | Supply Slip-on type flange adaptors for Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 300 - 350mm |
| 096059(I)G | Supply Slip-on type flange adaptors for Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 400mm |
| 096059(I)H | Supply Slip-on type flange adaptors for Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 450 - 525mm |
| 096059(I)I | Supply Slip-on type flange adaptors for Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 600 - 675mm |
| 096059(I)J | Supply Slip-on type flange adaptors for Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 700 - 750mm |
| 096059(I)K | Supply Slip-on type flange adaptors for Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 800 mm |
| 096059(I)L | Supply Slip-on type flange adaptors for Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 900 mm |
| 096059(I)M | Supply Slip-on type flange adaptors for Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 1000 - 1100 mm |
| 096059(I)N | Supply Slip-on type flange adaptors for Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 1200 mm |
| 096059(I)O | Supply Slip-on type flange adaptors for Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 1350 - 1400 mm |
| 096059(I)P | Supply Slip-on type flange adaptors for Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 1600 mm |
| 096059(I)Q | Supply Slip-on type flange adaptors for Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 1800 mm |
| 096059(I)R | Supply Slip-on type flange adaptors for Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 1950 - 2100 mm |
| 096059(I)S | Supply Slip-on type flange adaptors for Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 2200 mm |
| 096059(I)T | Supply Slip-on type flange adaptors for Steel pipes - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 2400 mm |
| 096059(II)C | Supply Slip-on type flange adaptors for Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 125 -150mm |
| 096059(II)D | Supply Slip-on type flange adaptors for Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 200mm |
| 096059(II)E | Supply Slip-on type flange adaptors for Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 250mm |
| 096059(II)F | Supply Slip-on type flange adaptors for Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 300 - 350mm |
| 096059(II)G | Supply Slip-on type flange adaptors for Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 400mm |
| 096059(II)H | Supply Slip-on type flange adaptors for Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 450 - 525mm |
| 096059(II)I | Supply Slip-on type flange adaptors for Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 600 - 675mm |
| 096059(II)J | Supply Slip-on type flange adaptors for Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 700 - 750mm |
| 096059(II)K | Supply Slip-on type flange adaptors for Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 800 mm |
| 096059(II)L | Supply Slip-on type flange adaptors for Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 900 mm |
| 096059(II)M | Supply Slip-on type flange adaptors for Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 1000 - 1100 mm |
| 096059(II)N | Supply Slip-on type flange adaptors for Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 1200 mm |
| 096059(II)O | Supply Slip-on type flange adaptors for Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 1350 - 1400 mm |
| 096059(II)P | Supply Slip-on type flange adaptors for Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 1600 mm |
| 096059(II)Q | Supply Slip-on type flange adaptors for Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 1800 mm |
| 096059(II)R | Supply Slip-on type flange adaptors for Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 1950 - 2100 mm |
| 096059(II)S | Supply Slip-on type flange adaptors for Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 2200 mm |
| 096059(II)T | Supply Slip-on type flange adaptors for Steel pipes - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 2400 mm |
| 096060(I)A | Supply Steel flange puddles - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 80mm & under |
| 096060(I)B | Supply Steel flange puddles - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 100mm |
| 096060(I)C | Supply Steel flange puddles - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 125 -150mm |
| 096060(I)D | Supply Steel flange puddles - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 200mm |
| 096060(I)E | Supply Steel flange puddles - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 250mm |
| 096060(I)F | Supply Steel flange puddles - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 300 - 350mm |
| 096060(I)G | Supply Steel flange puddles - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 400mm |
| 096060(I)H | Supply Steel flange puddles - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 450 - 525mm |
| 096060(I)I | Supply Steel flange puddles - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 600 - 675mm |
| 096060(I)J | Supply Steel flange puddles - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 700 - 750mm |
| 096060(I)K | Supply Steel flange puddles - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 800 mm |
| 096060(I)L | Supply Steel flange puddles - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 900 mm |
| 096060(I)M | Supply Steel flange puddles - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 1000 - 1100 mm |
| 096060(I)N | Supply Steel flange puddles - refer to fittings with the protection of epoxy coating etc. in accordance with Clause 15 of P.S. Appendix 22.02 . Nominal diameter of pipe 1200 mm |
| 096060(II)A | Supply Steel flange puddles - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 80mm & under |
| 096060(II)B | Supply Steel flange puddles - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 100mm |
| 096060(II)C | Supply Steel flange puddles - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 125 -150mm |
| 096060(II)D | Supply Steel flange puddles - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 200mm |
| 096060(II)E | Supply Steel flange puddles - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 250mm |
| 096060(II)F | Supply Steel flange puddles - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 300 - 350mm |
| 096060(II)G | Supply Steel flange puddles - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 400mm |
| 096060(II)H | Supply Steel flange puddles - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 450 - 525mm |
| 096060(II)I | Supply Steel flange puddles - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 600 - 675mm |
| 096060(II)J | Supply Steel flange puddles - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 700 - 750mm |
| 096060(II)K | Supply Steel flange puddles - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 800 mm |
| 096060(II)L | Supply Steel flange puddles - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 900 mm |
| 096060(II)M | Supply Steel flange puddles - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 1000 - 1100 mm |
| 096060(II)N | Supply Steel flange puddles - refer to fittings with the protection of bitumen lining etc. in accordance with Clause 16 of P.S. Appendix 22.02 . Nominal diameter of pipe 1200 mm |
| 096061(I)A | Supply D.I. flange spigot puddle Pipes - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 80mm & under |
| 096061(I)B | Supply D.I. flange spigot puddle Pipes - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 100mm |
| 096061(I)C | Supply D.I. flange spigot puddle Pipes - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 125 -150mm |
| 096061(I)D | Supply D.I. flange spigot puddle Pipes - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 200mm |
| 096061(I)E | Supply D.I. flange spigot puddle Pipes - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 250mm |
| 096061(I)F | Supply D.I. flange spigot puddle Pipes - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 300 - 350mm |
| 096061(I)G | Supply D.I. flange spigot puddle Pipes - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 400mm |
| 096061(I)H | Supply D.I. flange spigot puddle Pipes - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 450 - 525mm |
| 096061(I)I | Supply D.I. flange spigot puddle Pipes - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 600 - 675mm |
| 096061(II)A | Supply D.I. flange spigot puddle Pipes - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 80mm & under |
| 096061(II)B | Supply D.I. flange spigot puddle Pipes - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 100mm |
| 096061(II)C | Supply D.I. flange spigot puddle Pipes - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 125 -150mm |
| 096061(II)D | Supply D.I. flange spigot puddle Pipes - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 200mm |
| 096061(II)E | Supply D.I. flange spigot puddle Pipes - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 250mm |
| 096061(II)F | Supply D.I. flange spigot puddle Pipes - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 300 - 350mm |
| 096061(II)G | Supply D.I. flange spigot puddle Pipes - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 400mm |
| 096061(II)H | Supply D.I. flange spigot puddle Pipes - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 450 - 525mm |
| 096061(II)I | Supply D.I. flange spigot puddle Pipes - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 600 - 675mm |
| 096062(I)B | Supply D.I. double flange pipe bends and elbows to any angle - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 100mm |
| 096062(I)C | Supply D.I. double flange pipe bends and elbows to any angle - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 125 -150mm |
| 096062(I)D | Supply D.I. double flange pipe bends and elbows to any angle - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 200mm |
| 096062(I)E | Supply D.I. double flange pipe bends and elbows to any angle - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 250mm |
| 096062(I)F | Supply D.I. double flange pipe bends and elbows to any angle - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 300 - 350mm |
| 096062(I)G | Supply D.I. double flange pipe bends and elbows to any angle - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 400mm |
| 096062(I)H | Supply D.I. double flange pipe bends and elbows to any angle - refer to fittings with the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 450 - 525mm |
| 096062(II)B | Supply D.I. double flange pipe bends and elbows to any angle - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 100mm |
| 096062(II)C | Supply D.I. double flange pipe bends and elbows to any angle - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 125 -150mm |
| 096062(II)D | Supply D.I. double flange pipe bends and elbows to any angle - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 200mm |
| 096062(II)E | Supply D.I. double flange pipe bends and elbows to any angle - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 250mm |
| 096062(II)F | Supply D.I. double flange pipe bends and elbows to any angle - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 300 - 350mm |
| 096062(II)G | Supply D.I. double flange pipe bends and elbows to any angle - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 400mm |
| 096062(II)H | Supply D.I. double flange pipe bends and elbows to any angle - refer to fittings without the epoxy coating respectively as stipulated in Clause 14 of Appendix 22.03 to PS. Nominal diameter of pipe 450 - 525mm |
| 096063A | Supply High strength leakage repair clamps for pressurised water mains. Nominal diameter of pipe 80mm & under |
| 096063B | Supply High strength leakage repair clamps for pressurised water mains. Nominal diameter of pipe 100mm |
| 096063C | Supply High strength leakage repair clamps for pressurised water mains. Nominal diameter of pipe 125 -150mm |
| 096063D | Supply High strength leakage repair clamps for pressurised water mains. Nominal diameter of pipe 200mm |
| 096063E | Supply High strength leakage repair clamps for pressurised water mains. Nominal diameter of pipe 250mm |
| 096063F | Supply High strength leakage repair clamps for pressurised water mains. Nominal diameter of pipe 300 - 350mm |
| 096065C | Supply Stainless steel insert ring for the swaged PE pipe rehabilitated by close fit lining method. Nominal diameter of pipe 125 -150mm |
| 096065D | Supply Stainless steel insert ring for the swaged PE pipe rehabilitated by close fit lining method. Nominal diameter of pipe 200mm |
| 096065E | Supply Stainless steel insert ring for the swaged PE pipe rehabilitated by close fit lining method. Nominal diameter of pipe 250mm |
| 096065F | Supply Stainless steel insert ring for the swaged PE pipe rehabilitated by close fit lining method. Nominal diameter of pipe 300 - 350mm |
| 096065G | Supply Stainless steel insert ring for the swaged PE pipe rehabilitated by close fit lining method. Nominal diameter of pipe 400mm |
| 096065H | Supply Stainless steel insert ring for the swaged PE pipe rehabilitated by close fit lining method. Nominal diameter of pipe 450 - 525mm |
| 096065I | Supply Stainless steel insert ring for the swaged PE pipe rehabilitated by close fit lining method. Nominal diameter of pipe 600 - 675mm |
| 096066I | Supply Stainless steel end ring with rubber gasket for jointing pipe rehabilitated by Tyfo Fibrwrap System. Nominal diameter of pipe 600 - 675mm |
| 096066J | Suuply Stainless steel end ring with rubber gasket for jointing pipe rehabilitated by Tyfo Fibrwrap System. Nominal diameter of pipe 700 - 750mm |
| 096066K | Supply Stainless steel end ring with rubber gasket for jointing pipe rehabilitated by Tyfo Fibrwrap System. Nominal diameter of pipe 800mm |
| 096066L | Supply Stainless steel end ring with rubber gasket for jointing pipe rehabilitated by Tyfo Fibrwrap System. Nominal diameter of pipe 900mm |
| 097001 | Supply 150 mm (6 in) pedestal hydrant. |
| 097002 | Supply Swan neck hydrant. |
| 097003 | Supply 150 mm C.I. duckfoot bend. |
| 097004 | Supply Type I (DN 100) DI fire hydrant cap. |
| 097005 | Supply Type II (DN 80) DI fire hydrant cap. |
| 097006 | Supply C.I. distance piece, flanged, DN 150 x 150 mm long. |
| 097007 | Supply C.I. distance piece, flanged, DN 150 x 200 mm long. |
| 097008 | Supply C.I. distance piece, flanged, DN 150 x 300 mm long. |
| 097009 | Supply C.I. distance piece, flanged, DN 150 x 400 mm long. |
| 097010 | Supply C.I. distance piece flanged, DN 150 x 450 mm long. |
| 097011 | Supply D.I. distance piece, flanged, epoxy coated, DN 150 x 200 mm long. |
| 097012 | Supply D.I. distance piece, flanged, epoxy coated, DN 150 x 250 mm long. |
| 097013 | Supply D.I. distance piece, flanged, epoxy coated, DN 150 x 300 mm long. |
| 097014 | Supply D.I. distance piece, flanged, epoxy coated, DN 150 x 400 mm long. |
| 097015 | Supply D.I. distance piece flanged, epoxy coated, DN 150 x 500 mm long. |
| 097016a | Supply sleeve pipe for laying split steel sleeve pipe halves as detailed in Drawing No. SK 3380/8. 300 mm |
| 097016b | Supply sleeve pipe for laying split steel sleeve pipe halves as detailed in Drawing No. SK 3380/8. 400 mm |
| 097016c | Supply sleeve pipe for laying split steel sleeve pipe halves as detailed in Drawing No. SK 3380/8. 450 mm |
| 097016d | Supply sleeve pipe for laying split steel sleeve pipe halves as detailed in Drawing No. SK 3380/8. 500 mm |
| 097016e | Supply sleeve pipe for laying split steel sleeve pipe halves as detailed in Drawing No. SK 3380/8. 550 mm |
| 097016f | Supply sleeve pipe for laying split steel sleeve pipe halves as detailed in Drawing No. SK 3380/8. 600 mm |
| 097016g | Supply sleeve pipe for laying split steel sleeve pipe halves as detailed in Drawing No. SK 3380/8. 700 mm |
| 097016h | Supply sleeve pipe for laying split steel sleeve pipe halves as detailed in Drawing No. SK 3380/8. 750 mm |
| 097016i | Supply sleeve pipe for laying split steel sleeve pipe halves as detailed in Drawing No. SK 3380/8. 800 mm |
| 097017 | Supply steel sleeve pipe of diameter not less than 2000mm for jacking of sleeve pipe. |
| 098001 | Supply "Glenfield" 1049 quick acting float valve or equivalent 80 mm or below. |
| 098002 | Supply "Glenfield" 1049 quick acting float valve or equivalent 100 mm. |
| 098003 | Supply "Glenfield" 1049 quick acting float valve or equivalent 150 mm. |
| 098004 | Supply "Glenfield" 1049 quick acting float valve with auxiliary tank 1064 or equivalent 80 mm or below. |
| 098005 | Supply "Glenfield" 1049 quick acting float valve with auxiliary tank 1064 or equivalent 100 mm. |
| 098006 | Supply "Glenfield" 1049 quick acting float valve with auxiliary tank 1064 or equivalent 150 mm. |
| 098007 | Supply 140 mm x 115 mm light grade C.I. surface box as shown in Drawing No. WSD 7.24. |
| 098008 | Supply 140 mm x 115 mm light grade D.I. surface box as shown in Drawing No. WSD 7.44. |
| 098009 | Supply 180 mm x 180 mm C.I. Surface box as shown in Drawing No. WSD 7.25. |
| 098010 | Supply 180 mm x 180 mm D.I. Surface box as shown in Drawing No. WSD 7.45. |
| 098011 | Supply 285 mm x 200 mm C.I. Fire hydrant surface box as shown in Drawing No. WSD 7.26. |
| 098012 | Supply 285 mm x 200 mm D.I. Fire hydrant surface box as shown in Drawing No. WSD 7.46. |
| 098013 | Supply 300 mm x 300 mm D.I. Surface box as shown in Drawing No. WSD 7.47. |
| 098014 | As item no. 098/013, but for frame 150mm thick. |
| 098015 | Supply 600 mm x 600 mm M.S. manhole cover as shown in Drawing No. WSD 7.22. |
| 098016 | Supply 600 mm x 600 mm D.I. Manhole cover as shown in Drawing No. WSD 7.48. |
| 098017 | Supply fabricated steel recessed cover and frame to 600 mm x 600 mm manhole opening as shown in Drawing No. WSD 7.50. |
| 098018 | Supply fabricated steel recessed cover and frame to 915 mm x 915 mm manhole opening as shown in Drawing No. WSD 7.51. |
| 099001A | Supply pipeworks materials complete with pipes, fittings such as tees, valves and valve covers etc. for tee-connection. Size of pipe off which connection is to be made 50 mm & under |
| 099001B | Supply pipeworks materials complete with pipes, fittings such as tees, valves and valve covers etc. for tee-connection. Size of pipe off which connection is to be made 80 mm |
| 099001C | Supply pipeworks materials complete with pipes, fittings such as tees, valves and valve covers etc. for tee-connection. Size of pipe off which connection is to be made 100 mm |
| 099001D | Supply pipeworks materials complete with pipes, fittings such as tees, valves and valve covers etc. for tee-connection. Size of pipe off which connection is to be made 150 mm |
| 099001E | Supply pipeworks materials complete with pipes, fittings such as tees, valves and valve covers etc. for tee-connection. Size of pipe off which connection is to be made 200 mm |
| 099001F | Supply pipeworks materials complete with pipes, fittings such as tees, valves and valve covers etc. for tee-connection. Size of pipe off which connection is to be made 250 mm |
| 099001G | Supply pipeworks materials complete with pipes, fittings such as tees, valves and valve covers etc. for tee-connection. Size of pipe off which connection is to be made 300 mm |
| 099001H | Supply pipeworks materials complete with pipes, fittings such as tees, valves and valve covers etc. for tee-connection. Size of pipe off which connection is to be made 375 mm |
| 099001I | Supply pipeworks materials complete with pipes, fittings such as tees, valves and valve covers etc. for tee-connection. Size of pipe off which connection is to be made 400 mm |
| 099002 | Extra over item no. 099/001 for using 300mm x 300mm D.I. Surface Box with frame 150mm thick. |
| 099003A | Supply pipeworks materials for each additional metre run of branch pipe between 2 m and 8 m from the pipe junction. Size of branch pipe 50 mm & under |
| 099003B | Supply pipeworks materials for each additional metre run of branch pipe between 2 m and 8 m from the pipe junction. Size of branch pipe 80 mm |
| 099003C | Supply pipeworks materials for each additional metre run of branch pipe between 2 m and 8 m from the pipe junction. Size of branch pipe 100 mm |
| 099003D | Supply pipeworks materials for each additional metre run of branch pipe between 2 m and 8 m from the pipe junction. Size of branch pipe 150 mm |
| 099003E | Supply pipeworks materials for each additional metre run of branch pipe between 2 m and 8 m from the pipe junction. Size of branch pipe 200 mm |
| 099003F | Supply pipeworks materials for each additional metre run of branch pipe between 2 m and 8 m from the pipe junction. Size of branch pipe 250 mm |
| 099003G | Supply pipeworks materials for each additional metre run of branch pipe between 2 m and 8 m from the pipe junction. Size of branch pipe 300 mm |
| 099003H | Supply pipeworks materials for each additional metre run of branch pipe between 2 m and 8 m from the pipe junction. Size of branch pipe 375 mm |
| 099003I | Supply pipeworks materials for each additional metre run of branch pipe between 2 m and 8 m from the pipe junction. Size of branch pipe 400 mm |
| 100001 | In-situ concrete Grade 10/20. |
| 100002 | In-situ concrete Grade 20/20. |
| 100003 | In-situ concrete Grade 20/10. |
| 100004 | In-situ concrete Grade 25/20. |
| 100005 | In-situ concrete Grade 25/10. |
| 100006 | In-situ concrete Grade 30/20. |
| 100007 | In-situ concrete Grade 30/10. |
| 100008 | In-situ concrete Grade 35/20. |
| 100009 | In-situ concrete Grade 40/20. |
| 100010 | In-situ concrete Grade 40/10. |
| 100011a | In-situ concrete Grade 35/20D for liquid retaining structures. |
| 100011b | In-situ concrete Grade 45/20D for liquid retaining structures. |
| 100012 | In-situ concrete No-fines concrete. |
| 100013 | In-situ concrete Lean concrete. |
| 100014 | Concrete under water Grade 20/20. |
| 100015 | Concrete under water Grade 20/10. |
| 100016 | Concrete under water Grade 25/20. |
| 100017 | Concrete under water Grade 25/10. |
| 100018 | Concrete under water Grade 30/20. |
| 100019 | Concrete under water Grade 30/10. |
| 100020 | Concrete under water Grade 35/20. |
| 100021 | Foam concrete. |
| 100022 | Rapid hardening concrete Extra over Item Nos. 100/001 to 100/020 for use of rapid hardening concrete. |
| 100023 | Cut hole In concrete or reinforced concrete on highways structures, earth retaining structures, culverts, manholes and the like. |
| 100024 | Cut chase or pocket In concrete or in reinforced concrete. |
| 100025 | Cut letter, character or numeral In concrete area, not exceeding 300 mm x 300 mm. |
| 100026 | Drill hole in concrete Diameter not exceeding 25 mm. |
| 100027 | Drill hole in concrete Diameter exceeding 25 mm but not exceeding 50 mm. |
| 100028 | Drill hole in concrete Diameter exceeding 50 mm but not exceeding 75 mm. |
| 100029 | Drill hole in concrete Diameter exceeding 75 mm but not exceeding 100 mm. |
| 100030 | Drill hole in concrete Diameter exceeding 100 mm but not exceeding 150 mm. |
| 100031 | Remove precast concrete unit. |
| 100032 | Remove for re-use precast concrete unit. |
| 100033 | Fix precast concrete unit. |
| 100034 | Supply precast concrete unit Grade 30 or below. |
| 100035 | Supply precast concrete unit Grade 35 or above. |
| 100036 | Establishment of coring equipment. |
| 100037 | Coring not exceeding 50 mm diameter. |
| 100038 | Coring 65 mm diameter. |
| 100039 | Coring 75 mm diameter. |
| 100040 | Coring 100 mm diameter. |
| 100041 | Coring 150 mm diameter. |
| 100042 | Fast hardening mortar. |
| 100043 | Epoxy resin mortar not exceeding 10 mm thick. |
| 100044 | Epoxy resin mortar in excess of 10 mm thick. |
| 100045 | Hight strength repair mortar BASF Emaco S188 high strength concrete repair mortar or approved products having equivalent functions and performance not exceeding 10 mm thick. |
| 100046 | Hight strength repair mortar BASF Emaco S188 high strength concrete repair mortar or approved products having equivalent functions and performance in excess of 10 mm thick. |
| 101001 | Formwork not exceeding 300 mm wide Class F1 Inclination to the horizontal Exceeding -- Not exceeding 5 degree |
| 101002 | Formwork not exceeding 300 mm wide Class F1 Inclination to the horizontal Exceeding 5 degree Not exceeding 85 degree |
| 101003 | Formwork not exceeding 300 mm wide Class F1 Inclination to the horizontal Exceeding 85 degree Not exceeding 90 degree |
| 101004 | Formwork not exceeding 300 mm wide Class F2 Inclination to the horizontal Exceeding -- Not exceeding 5 degree |
| 101005 | Formwork not exceeding 300 mm wide Class F2 Inclination to the horizontal Exceeding 5 degree Not exceeding 85 degree |
| 101006 | Formwork not exceeding 300 mm wide Class F2 Inclination to the horizontal Exceeding 85 degree Not exceeding 90 degree |
| 101007 | Formwork not exceeding 300 mm wide Class F3 Inclination to the horizontal Exceeding -- Not exceeding 5 degree |
| 101008 | Formwork not exceeding 300 mm wide Class F3 Inclination to the horizontal Exceeding 5 degree Not exceeding 85 degree |
| 101009 | Formwork not exceeding 300 mm wide Class F3 Inclination to the horizontal Exceeding 85 degree Not exceeding 90 degree |
| 101010 | Formwork not exceeding 300 mm wide Class F4 Inclination to the horizontal Exceeding -- Not exceeding 5 degree |
| 101011 | Formwork not exceeding 300 mm wide Class F4 Inclination to the horizontal Exceeding 5 degree Not exceeding 85 degree |
| 101012 | Formwork not exceeding 300 mm wide Class F4 Inclination to the horizontal Exceeding 85 degree Not exceeding 90 degree |
| 101013 | Formwork exceeding 300 mm wide Class F1 Inclination to the horizontal Exceeding -- Not exceeding 5 degree |
| 101014 | Formwork exceeding 300 mm wide Class F1 Inclination to the horizontal Exceeding 5 degree Not exceeding 85 degree |
| 101015 | Formwork exceeding 300 mm wide Class F1 Inclination to the horizontal Exceeding 85 degree Not exceeding 90 degree |
| 101016 | Formwork exceeding 300 mm wide Class F2 Inclination to the horizontal Exceeding -- Not exceeding 5 degree |
| 101017 | Formwork exceeding 300 mm wide Class F2 Inclination to the horizontal Exceeding 5 degree Not exceeding 85 degree |
| 101018 | Formwork exceeding 300 mm wide Class F2 Inclination to the horizontal Exceeding 85 degree Not exceeding 90 degree |
| 101019 | Formwork exceeding 300 mm wide Class F3 Inclination to the horizontal Exceeding - Not exceeding 5 degree |
| 101020 | Formwork exceeding 300 mm wide Class F3 Inclination to the horizontal Exceeding 5 degree Not exceeding 85 degree |
| 101021 | Formwork exceeding 300 mm wide Class F3 Inclination to the horizontal Exceeding 85 degree Not exceeding 90 degree |
| 101022 | Formwork exceeding 300 mm wide Class F4 Inclination to the horizontal Exceeding - Not exceeding 5 degree |
| 101023 | Formwork exceeding 300 mm wide Class F4 Inclination to the horizontal Exceeding 5 degree Not exceeding 85 degree |
| 101024 | Formwork exceeding 300 mm wide Class F4 Inclination to the horizontal Exceeding 85 degree Not exceeding 90 degree |
| 101025 | Curved formwork on any plane Class F1 Width Exceeding -- Not exceeding 300 mm |
| 101026 | Curved formwork on any plane Class F2 Width Exceeding -- Not exceeding 300 mm |
| 101027 | Curved formwork on any plane Class F3 Width Exceeding -- Not exceeding 300 mm |
| 101028 | Curved formwork on any plane Class F4 Width Exceeding -- Not exceeding 300 mm |
| 101029 | Curved formwork on any plane Class F1 Width Exceeding 300 mm Not exceeding -- |
| 101030 | Curved formwork on any plane Class F2 Width Exceeding 300 mm Not exceeding -- |
| 101031 | Curved formwork on any plane Class F3 Width Exceeding 300 mm Not exceeding -- |
| 101032 | Curved formwork on any plane Class F4 Width Exceeding 300 mm Not exceeding -- |
| 110001 | Plain steel reinforcing bar, Grade 250, not exceeding 12.00 metres in length 16 mm diameter and below. |
| 110002 | Plain steel reinforcing bar, Grade 250, not exceeding 12.00 metres in length 20 mm diameter and above. |
| 110003 | Ribbed steel reinforcing bar, Grade 500B, not exceeding 12.00 metres in length 16 mm diameter and below. |
| 110004 | Ribbed steel reinforcing bar, Grade 500B, not exceeding 12.00 metres in length 20 mm diameter and above. |
| 110005 | Steel fabric reinforcement as BS 4483 Ref. BS Reference A 393. |
| 110006 | Steel fabric reinforcement as BS 4483 Ref. BS Reference A 252. |
| 110007 | Steel fabric reinforcement as BS 4483 Ref. BS Reference A 193. |
| 110008 | Steel fabric reinforcement as BS 4483 Ref. BS Reference A 142. |
| 110009 | Steel fabric reinforcement as BS 4483 Ref. BS Reference A 98. |
| 110010 | Steel fabric reinforcement as BS 4483 Ref. BS Reference C 785. |
| 110011 | Steel fabric reinforcement as BS 4483 Ref. BS Reference C 636. |
| 110012 | Steel fabric reinforcement as BS 4483 Ref. BS Reference C 503. |
| 110013 | Steel fabric reinforcement as BS 4483 Ref. BS Reference C 385. |
| 110014 | Steel fabric reinforcement as BS 4483 Ref. BS Reference C 283. |
| 110015 | Drill hole in edge of carriageway and embed dowel bar with dowel sheath or P.V.C. sleeve using low viscosity epoxy resin. Bar diameter 12 mm and embedded length 500 mm. |
| 110016 | Drill hole in edge of carriageway and embed dowel bar with dowel sheath or P.V.C. sleeve using low viscosity epoxy resin. Bar diameter 20 mm and embedded length 325 mm. |
| 110017 | Drill hole in edge of carriageway and embed dowel bar with dowel sheath or P.V.C. sleeve using low viscosity epoxy resin. Bar diameter 25 mm and embedded length 325 mm. |
| 110018 | Drill hole in wall of catchwater and embed 16 mm diameter dowel bar not exceeding 1000 mm long using non-shrinkage cement grout with an embedded length of 300 mm. |
| 120001 | Mobilize full set of drilling equipment over land |
| 120002 | Mobilize full set of portable coring equipment over land |
| 120003 | Mobilize full set of portable drilling equipment over land |
| 120004 | Moving full set of drilling equipment:- moving distance not exceeding 100m |
| 120005 | Moving full set of drilling equipment:- moving distance exceeding 100m but not exceeding 200m |
| 120006 | Extra over items 120/004 and 120/005 by using : Heavy scaffolding |
| 120007 | Extra over items 120/004 and 120/005 by using : Light scaffolding |
| 120008 | Moving full set of portable drilling equipment |
| 120009 | Moving full set of portable coring equipment |
| 120010 | Standing time for full set of drilling equipment |
| 120011 | Standing time for full set of portable coring equipment |
| 120012 | Standing time for full set of portable drilling equipment |
| 120013 | Drilling, hole size N, vertically downwards, from ground level to a depth not exceeding 20 m in length : - material other than rock, artificial hard material or boulder |
| 120014 | Drilling, hole size N, vertically downwards, from ground level to a depth not exceeding 20 m in length : - rock |
| 120015 | Drilling, hole size N, vertically downwards, from ground level to a depth not exceeding 20 m in length : - artificial hard material and boulder |
| 120016 | Drilling, hole size N, vertically downwards, from ground level to a depth exceeding 20m but not exceeding 40 m in length : - material other than rock, artificial hard material or boulder |
| 120017 | Drilling, hole size N, vertically downwards, from ground level to a depth exceeding 20m but not exceeding 40 m in length : - rock |
| 120018 | Drilling, hole size N, vertically downwards, from ground level to a depth exceeding 20m but not exceeding 40 m in length : - artificial hard material and boulder |
| 120019 | Drilling, hole size N, vertically downwards, from ground level to a depth exceeding 40m but not exceeding 60 m in length : - material other than rock, artificial hard material or boulder |
| 120020 | Drilling, hole size N, vertically downwards, from ground level to a depth exceeding 40m but not exceeding 60 m in length : - rock |
| 120021 | Drilling, hole size N, vertically downwards, from ground level to a depth exceeding 40m but not exceeding 60 m in length : - artificial hard material and boulder |
| 120022 | Drilling, hole size H, vertically downwards, from ground level to a depth not exceeding 20 m in length:- material other than rock, artificial hard material or boulder |
| 120023 | Drilling, hole size H, vertically downwards, from ground level to a depth not exceeding 20 m in length:- rock |
| 120024 | Drilling, hole size H, vertically downwards, from ground level to a depth not exceeding 20 m in length:- artificial hard material and boulder |
| 120025 | Drilling, hole size H, vertically downwards, from ground level to a depth exceeding 20m but not exceeding 40 m in length : - material other than rock, artificial hard material or boulder |
| 120026 | Drilling, hole size H, vertically downwards, from ground level to a depth exceeding 20m but not exceeding 40 m in length : - rock |
| 120027 | Drilling, hole size H, vertically downwards, from ground level to a depth exceeding 20m but not exceeding 40 m in length : - artificial hard material and boulder |
| 120028 | Drilling, hole size H, vertically downwards, from ground level to a depth exceeding 40m but not exceeding 60 m in length : - material other than rock, artificial hard material or boulder |
| 120029 | Drilling, hole size H, vertically downwards, from ground level to a depth exceeding 40m but not exceeding 60 m in length : - rock |
| 120030 | Drilling, hole size H, vertically downwards, from ground level to a depth exceeding 40m but not exceeding 60 m in length : - artificial hard material and boulder |
| 120031 | Drilling, hole size P, vertically downwards, from ground level to a depth not exceeding 20 m in length : - material other than rock, artificial hard material or boulder |
| 120032 | Drilling, hole size P, vertically downwards, from ground level to a depth not exceeding 20 m in length : - rock |
| 120033 | Drilling, hole size P, vertically downwards, from ground level to a depth not exceeding 20 m in length : - artificial hard material and boulder |
| 120034 | Drilling, hole size P, vertically downwards, from ground level to a depth exceeding 20m but not exceeding 40 m in length : - material other than rock, artificial hard material or boulder |
| 120035 | Drilling, hole size P, vertically downwards, from ground level to a depth exceeding 20m but not exceeding 40 m in length : - rock |
| 120036 | Drilling, hole size P, vertically downwards, from ground level to a depth exceeding 20m but not exceeding 40 m in length : - artificial hard material and boulder |
| 120037 | Drilling, hole size P, vertically downwards, from ground level to a depth exceeding 40m but not exceeding 60 m in length : - material other than rock, artificial hard material or boulder |
| 120038 | Drilling, hole size P, vertically downwards, from ground level to a depth exceeding 40m but not exceeding 60 m in length : - rock |
| 120039 | Drilling, hole size P, vertically downwards, from ground level to a depth exceeding 40m but not exceeding 60 m in length : - artificial hard material and boulder |
| 120040 | Drilling, hole size N, downwards at an angle of 0° to 45° to the vertical, from ground level to a depth not exceeding 20m in length: - material other than rock, artificial hard material or boulder |
| 120041 | Drilling, hole size N, downwards at an angle of 0° to 45° to the vertical, from ground level to a depth not exceeding 20m in length: - rock |
| 120042 | Drilling, hole size N, downwards at an angle of 0° to 45° to the vertical, from ground level to a depth not exceeding 20m in length: - artificial hard material and boulder |
| 120043 | Drilling, hole size H, downwards at an angle of 0° to 45° to the vertical, from ground level to a depth not exceeding 20m in length: - material other than rock, artificial hard material or boulder |
| 120044 | Drilling, hole size H, downwards at an angle of 0° to 45° to the vertical, from ground level to a depth not exceeding 20m in length: - rock |
| 120045 | Drilling, hole size H, downwards at an angle of 0° to 45° to the vertical, from ground level to a depth not exceeding 20m in length: - artificial hard material and boulder |
| 120046 | Drilling, hole size P, downwards at an angle of 0° to 45° to the vertical, from ground level to a depth not exceeding 20m in length: - material other than rock, artificial hard material or boulder |
| 120047 | Drilling, hole size P, downwards at an angle of 0° to 45° to the vertical, from ground level to a depth not exceeding 20m in length: - rock |
| 120048 | Drilling, hole size P, downwards at an angle of 0° to 45° to the vertical, from ground level to a depth not exceeding 20m in length: - artificial hard material and boulder |
| 120049 | Extra over Item Nos. 120/013 to 120/048 for using triple tube core barrels |
| 120050 | Coring, hole size N, horizontally or downwards at an angle less than 45° to the horizontal : - material other than rock, artificial hard material or boulder |
| 120051 | Coring, hole size N, horizontally or downwards at an angle less than 45° to the horizontal : - rock |
| 120052 | Coring, hole size N, horizontally or downwards at an angle less than 45° to the horizontal : - artificial hard material and boulder |
| 120053 | Coring, hole size H, horizontally or downwards at an angle less than 45° to the horizontal : - material other than rock, artificial hard material or boulder |
| 120054 | Coring, hole size H, horizontally or downwards at an angle less than 45° to the horizontal : - rock |
| 120055 | Coring, hole size H, horizontally or downwards at an angle less than 45° to the horizontal : - artificial hard material and boulder |
| 120056 | Trial pits, maximum depth not exceeding 3.00 m |
| 120057 | Ditto, maximum depth exceeding 3.00 m but not exceeding 6.00 m |
| 120058 | Extra over Item No. 120/056 for excavation in rock, maximum depth not exceeding 3.00 m |
| 120059 | Extra over Item No. 120/057 for excavation in rock, maximum depth exceeding 3.00 m but not exceeding 6.00 m |
| 120060 | Extra over Item No. 120/056 for excavation in artificial hard material, maximum depth not exceeding 3.00 m |
| 120061 | Extra over Item No. 120/057 for excavation in artificial hard material, maximum depth exceeding 3.00 m but not exceeding 6.00 m |
| 120062 | Standing time for trial pit crew |
| 120063 | Filling of trial pit:- With special fill material |
| 120064 | Filling of trial pit:- With Grade 10 concrete |
| 120065 | Filling of trial pit:- With soil-cement fill |
| 120066 | Filling of trial pit:- With rock fill material |
| 120067 | Filling of trial pit:- With Grade 20 sprayed concrete |
| 120068 | Filling of trial pit:- With Grade 30 sprayed concrete |
| 120068a | Handling land and traffic matters/issues for Geotechnical Works located outside WSD boundary |
| 120069 | Take from drillhole / corehole : - Mazier sample |
| 120070 | Take from drillhole / corehole : - rock core; size N |
| 120071 | Take from drillhole / corehole : - rock core; size H |
| 120072 | Take from drillhole / corehole : - core for Common Ground, size N |
| 120073 | Take from drillhole / corehole : - core for Common Ground, size H |
| 120074 | Take from drillhole / corehole : - core for artificial hard material and boulder, size N |
| 120075 | Take from drillhole / corehole : - core for artificial hard material and boulder, size H |
| 120076 | Take from drillhole / corehole : - groundwater sample |
| 120077 | Take from drillhole / corehole : - U76 sample |
| 120078 | Take from drillhole / corehole : - U100 sample |
| 120079 | Take from trial pit : - U76 sample |
| 120080 | Take from trial pit : - U100 sample |
| 120081 | Take from trial pit : - block sample |
| 120082 | Take from trial pit : - bulk sample |
| 120083 | Standard penetration test including liner sample |
| 120084 | Standard penetration test excluding liner sample |
| 120085 | In-situ density test; (GEOSPEC 3, Test 11.1) |
| 120086 | In-situ density test; (GEOSPEC 3, Test 11.2) |
| 120087 | Rebound hammer test |
| 120088 | Falling head permeability test |
| 120089 | Constant head permeability test |
| 120090 | Packer (water absorption) test, from ground level to a depth not exceeding 60m |
| 120091 | Response test in standpipe / piezometer |
| 120092 | Impression packer survey, from ground level to a depth not exceeding 60m |
| 120093 | Pressuremeter test, testing depth not exceeding 60m |
| 120094 | Inclination and bearing measurement, depth not exceeding 60m |
| 120095 | GCO Probe Test : - Testing depth not exceeding 3.00m |
| 120096 | GCO Probe Test : - Testing depth exceeding 3.00m but not exceeding 6.00m |
| 120097 | GCO Probe Test : - Testing depth exceeding 6.00m but not exceeding 9.00m |
| 120098 | GCO Probe Test : - Testing depth exceeding 9.00m but not exceeding 12.00m |
| 120099 | GCO Probe Test : - Resistivity Test by Wenner probe method (BS 1377:Part 3:1990, clause 10.3) |
| 120100 | Geophysical Testing Acoustic borehole televiewer survey, from ground level to a depth not exceeding 60m. |
| 120101 | Geophysical Testing Magnetometry survey |
| 120102 | Standpipe Piezometer as shown in Drawing No. C2005: - depth of piezometer tip not exceeding 10m |
| 120103 | Standpipe Piezometer as shown in Drawing No. C2005: - depth of piezometer tip exceeding 10m but not exceeding 20m |
| 120104 | Standpipe Piezometer as shown in Drawing No. C2005: - depth of piezometer tip exceeding 20m but not exceeding 30m |
| 120105 | Standpipe Piezometer as shown in Drawing No. C2005: - depth of piezometer tip exceeding 30m but not exceeding 40m |
| 120106 | Standpipe : - depth not exceeding 10m |
| 120107 | Standpipe : - depth exceeding 10m but not exceeding 20m |
| 120108 | Standpipe : - depth exceeding 20m but not exceeding 30m |
| 120109 | Standpipe : - depth exceeding 30m but not exceeding 40m |
| 120110 | String for Halcrow buckets, depth not exceeding 40m |
| 120111 | Halcrow bucket |
| 120112 | Inclinometer, depth not exceeding 40m |
| 120113 | Final ground investigation field work report |
| 120114 | Additional copy of final ground investigation field work report |
| 120115 | Installation of settlement monitoring point as shown in Drawing Nos. C2512 and C2513 |
| 120116 | Installation of survey monitoring point as shown in Drawing No. H6119: Survey nail with Type A SS washer for horizontal control |
| 120117 | Installation of survey monitoring point as shown in Drawing No. H6119: Survey nail with Type B SS washer for horizontal control |
| 120118 | Installation of survey monitoring point as shown in Drawing No. H6119: Type A SS Pin with Type C SS washer for vertical control |
| 120119 | Installation of survey monitoring point as shown in Drawing No. H6119: Type B SS Pin with Type C SS washer for vertical control |
| 120120 | Installation of tell-tale |
| 120121 | Monitoring of survey monitoring point |
| 120122 | Monitoring of tell-tale |
| 120123 | Monitoring of existing Standpipes/Piezometers and the associated Piezometer Buckets |
| 120124 | Monitoring of inclinometer |
| 120136 | Inspection scaffolding |
| 120137 | Install a system of nylon ropes 12mm diameter for scaffolding |
| 120138 | Stripping to existing soil slope surface |
| 120139 | Stripping to existing impermeable slope surface |
| 120140 | Reinstatement of existing slope surface |
| 120141 | Rock scaling |
| 120142 | Removing of boulders |
| 120143 | Mesh protection as shown in Drawing No. C2205 |
| 120144 | Sealing rock joints with 1:3 cement mortar |
| 120145 | Infilling rock joint with no-fines concrete |
| 120146 | Ditto, with grade 20/20 concrete |
| 120147 | Ditto, with soil-cement fill |
| 120148 | Relief drains 200 mm wide as shown in Drawing No. C2404 |
| 120149 | Establishment of equipment for raking drain. |
| 120150 | Moving equipment for raking drain. |
| 120151 | Drilling drain hole, upwards at an angle 0o - 45o to the horizontal, length not exceeding 25m, minimum diameter:- 55 mm |
| 120152 | Drilling drain hole, upwards at an angle 0o - 45o to the horizontal, length not exceeding 25m, minimum diameter:- 60 mm |
| 120153 | Drilling drain hole, upwards at an angle 0o - 45o to the horizontal, length not exceeding 25m, minimum diameter:- 95 mm |
| 120154 | Raking drains, upwards at an angle 0° - 45° to the horizontal as shown in Drawing No. C2403, length not exceeding 25 m :- Type 1 |
| 120155 | Raking drains, upwards at an angle 0° - 45° to the horizontal as shown in Drawing No. C2403, length not exceeding 25 m :- Type 2 |
| 120156 | Raking drains, upwards at an angle 0° - 45° to the horizontal as shown in Drawing No. C2403, length not exceeding 25 m :- Type 3 |
| 120157 | Drilling drain hole, upwards at an angle 0° - 45° to the horizontal, length exceeding 25m but not exceeding 40m, minimum diameter:- 55 mm |
| 120158 | Drilling drain hole, upwards at an angle 0° - 45° to the horizontal, length exceeding 25m but not exceeding 40m, minimum diameter:- 60 mm |
| 120159 | Drilling drain hole, upwards at an angle 0° - 45° to the horizontal, length exceeding 25m but not exceeding 40m, minimum diameter:- 95 mm |
| 120160 | Raking drains, upwards at an angle 0° - 45° to the horizontal as shown in Drawing No. C2403, length exceeding 25 m but not exceeding 40 m :- Type 1 |
| 120161 | Raking drains, upwards at an angle 0° - 45° to the horizontal as shown in Drawing No. C2403, length exceeding 25 m but not exceeding 40 m :- Type 2 |
| 120162 | Raking drains, upwards at an angle 0° - 45° to the horizontal as shown in Drawing No. C2403, length exceeding 25 m but not exceeding 40 m :- Type 3 |
| 120163 | Forming drain hole by coring, minimum diameter:- Extra over Item Nos. 120/151 and 120/157 for minimum diameter 55mm |
| 120164 | Forming drain hole by coring, minimum diameter:- Extra over Item Nos. 120/152 and 120/158 for minimum diameter 60mm |
| 120165 | Forming drain hole by coring, minimum diameter:- Extra over Item Nos. 120/153 and 120/159 for minimum diameter 95mm |
| 120166 | Raking drain connection to surface channel, 100mm nominal size as shown in Drawing No. C2414:- For soil slope with erosion control mat |
| 120167 | Raking drain connection to surface channel, 100mm nominal size as shown in Drawing No. C2414:- For soil slope without erosion control mat |
| 120168 | Raking drain connection to surface channel, 100mm nominal size as shown in Drawing No. C2414:- For shotcreted slope |
| 120169 | Permanent PVC casing:- for raking drain in hole of 55mm diameter |
| 120170 | Permanent PVC casing:- for raking drain in hole of 60mm diameter |
| 120171 | Permanent PVC casing:- for raking drain in hole of 95mm diameter |
| 120172 | Permanent steel casing:- for raking drain in hole of 55mm diameter |
| 120173 | Permanent steel casing:- for raking drain in hole of 60mm diameter |
| 120174 | Permanent steel casing:- for raking drain in hole of 95mm diameter |
| 120175 | Establishment of equipment for rock bolts |
| 120176 | Moving equipment for rock bolts |
| 120177 | Rock bolts as shown in Drawing No. C2201, working load 100 kN, free length :- 1 m |
| 120178 | Rock bolts as shown in Drawing No. C2201, working load 100 kN, free length :- 2 m |
| 120179 | Rock bolts as shown in Drawing No. C2201, working load 100 kN, free length :- 3 m |
| 120180 | Rock bolts as shown in Drawing No. C2201, working load 100 kN, free length :- 4 m |
| 120181 | Surface Protection Colouring and Painting. Chunam, 50 mm thick |
| 120183 | Extra over for Item No. 120/181 for each additional 25 mm thickness |
| 120184 | Extra over for Item No. 120/181 for forming channels irrespective of thickness of chunam |
| 120185 | Grade 20 sprayed concrete with one layer of A252 mesh : - 75 mm thick |
| 120186 | Grade 20 sprayed concrete with one layer of A252 mesh : - 100 mm thick |
| 120187 | Grade 20 sprayed concrete with one layer of A252 mesh : - 150 mm thick |
| 120188 | Grade 20 sprayed concrete, 200 mm thick with two layers of A252 mesh |
| 120189 | Grade 20 sprayed concrete, 100 mm thick with one layer of A393 mesh |
| 120190 | Grade 20 sprayed concrete with two layers of A393 mesh: - 200 mm thick |
| 120191 | Grade 20 sprayed concrete with two layers of A393 mesh: - 300 mm thick |
| 120192 | Grade 20 sprayed concrete, with one layer of 50 mm x 50 mm x 2.7 mm (wire diameter) welded mesh, galvanized:- 50 mm thick |
| 120193 | Grade 20 sprayed concrete, with one layer of 50 mm x 50 mm x 2.7 mm (wire diameter) welded mesh, galvanized:- 75 mm thick |
| 120194 | Grade 20 sprayed concrete, with one layer of 50 mm x 50 mm x 2.7 mm (wire diameter) welded mesh, galvanized:- 100 mm thick |
| 120195 | Grade 20 sprayed concrete, 150mm thick with two layers of 50mm x 50mm x 2.7mm (wire diameter) welded mesh, galvanized |
| 120196 | Grade 20 sprayed concrete, without mesh: - 25 mm thick. |
| 120197 | Grade 20 sprayed concrete, without mesh: - 50 mm thick |
| 120198 | Grade 20 sprayed concrete, without mesh: - 75 mm thick |
| 120199 | Grade 20 sprayed concrete, without mesh: - 100 mm thick |
| 120200 | Grade 20 sprayed concrete, without mesh: - 150 mm thick |
| 120201 | Grade 30 sprayed concrete, without mesh: - 25 mm thick. |
| 120202 | Grade 30 sprayed concrete, without mesh: - 50 mm thick. |
| 120203 | Grade 30 sprayed concrete, without mesh: - 75 mm thick. |
| 120204 | Grade 30 sprayed concrete, without mesh: - 100 mm thick. |
| 120206 | Extra over Item No. 120/200 for each additional mm thick of sprayed concrete above 150 mm |
| 120207 | Extra over Item No. 120/204 for each additional mm thick of sprayed concrete above 100 mm |
| 120208 | Extra over for colour pigment in sprayed concrete :- dark brown or dark green |
| 120209 | Extra over for colour pigment in sprayed concrete :- light brown or light green |
| 120210 | Painting on sprayed concrete surface with 2 coats of water based paint |
| 120211 | Establishment of equipment for rock dowels |
| 120212 | Moving equipment for rock dowels |
| 120213 | Rock dowels as shown in Drawing No. C2202, X mm diameter, Y metre in length :- X (mm) : 16 Y (m) : 2 |
| 120214 | Rock dowels as shown in Drawing No. C2202, X mm diameter, Y metre in length :- X (mm) : 20 Y (m) : 2 |
| 120215 | Rock dowels as shown in Drawing No. C2202, X mm diameter, Y metre in length :- X (mm) : 25 Y (m) : 2 |
| 120216 | Rock dowels as shown in Drawing No. C2202, X mm diameter, Y metre in length :- X (mm) : 32 Y (m) : 2 |
| 120217 | Rock dowels as shown in Drawing No. C2202, X mm diameter, Y metre in length :- X (mm) : 16 Y (m) : 3 |
| 120218 | Rock dowels as shown in Drawing No. C2202, X mm diameter, Y metre in length :- X (mm) : 20 Y (m) : 3 |
| 120219 | Rock dowels as shown in Drawing No. C2202, X mm diameter, Y metre in length :- X (mm) : 25 Y (m) : 3 |
| 120220 | Rock dowels as shown in Drawing No. C2202, X mm diameter, Y metre in length :- X (mm) : 32 Y (m) : 3 |
| 120221 | Rock dowels as shown in Drawing No. C2202, X mm diameter, Y metre in length :- X (mm) : 16 Y (m) : 4 |
| 120222 | Rock dowels as shown in Drawing No. C2202, X mm diameter, Y metre in length :- X (mm) : 20 Y (m) : 4 |
| 120223 | Rock dowels as shown in Drawing No. C2202, X mm diameter, Y metre in length :- X (mm) : 25 Y (m) : 4 |
| 120224 | Rock dowels as shown in Drawing No. C2202, X mm diameter, Y metre in length :- X (mm) : 32 Y (m) : 4 |
| 120225 | Rock dowels as shown in Drawing No. C2202, X mm diameter, Y metre in length :- X (mm) : 16 Y (m) : 5 |
| 120226 | Rock dowels as shown in Drawing No. C2202, X mm diameter, Y metre in length :- X (mm) : 20 Y (m) : 5 |
| 120227 | Rock dowels as shown in Drawing No. C2202, X mm diameter, Y metre in length :- X (mm) : 25 Y (m) : 5 |
| 120228 | Rock dowels as shown in Drawing No. C2202, X mm diameter, Y metre in length :- X (mm) : 32 Y (m) : 5 |
| 120229 | Rock dowels as shown in Drawing No. C2202, X mm diameter, Y metre in length :- X (mm) : 16 Y (m) : 6 |
| 120230 | Rock dowels as shown in Drawing No. C2202, X mm diameter, Y metre in length :- X (mm) : 20 Y (m) : 6 |
| 120231 | Rock dowels as shown in Drawing No. C2202, X mm diameter, Y metre in length :- X (mm) : 25 Y (m) : 6 |
| 120232 | Rock dowels as shown in Drawing No. C2202, X mm diameter, Y metre in length :- X (mm) : 32 Y (m) : 6 |
| 120233 | Hot dip galvanized dowels, 20 mm diameter high yield steel with X mm penetrated into existing structures or rock, embedded Y mm into buttress and the like as shown in Drawing No. C2203/1, with standard bends, hooks or the like in shape : ("e." represents "exceeding" and "n.e." represents "not exceeding".) X (mm) : n.e. 500 Y (mm) : n.e. 1000 |
| 120234 | Hot dip galvanized dowels, 20 mm diameter high yield steel with X mm penetrated into existing structures or rock, embedded Y mm into buttress and the like as shown in Drawing No. C2203/1, with standard bends, hooks or the like in shape : ("e." represents "exceeding" and "n.e." represents "not exceeding".) X (mm) : e.500 but n.e.1000 Y (mm) : n.e. 1000 |
| 120235 | Hot dip galvanized dowels, 20 mm diameter high yield steel with X mm penetrated into existing structures or rock, embedded Y mm into buttress and the like as shown in Drawing No. C2203/1, with standard bends, hooks or the like in shape : ("e." represents "exceeding" and "n.e." represents "not exceeding".) X (mm) : e.1000 but n.e.1500 Y (mm) : n.e. 1000 |
| 120236 | Hot dip galvanized dowels, 20 mm diameter high yield steel with X mm penetrated into existing structures or rock, embedded Y mm into buttress and the like as shown in Drawing No. C2203/1, with standard bends, hooks or the like in shape : ("e." represents "exceeding" and "n.e." represents "not exceeding".) X (mm) : e.1500 but n.e.2000 Y (mm) : n.e. 1000 |
| 120237 | Hot dip galvanized dowels, 20 mm diameter high yield steel with X mm penetrated into existing structures or rock, embedded Y mm into buttress and the like as shown in Drawing No. C2203/1, with standard bends, hooks or the like in shape : ("e." represents "exceeding" and "n.e." represents "not exceeding".) X (mm) : e.2000 but n.e.2500 Y (mm) : n.e. 1000 |
| 120238 | Hot dip galvanized dowels, 20 mm diameter high yield steel with X mm penetrated into existing structures or rock, embedded Y mm into buttress and the like as shown in Drawing No. C2203/1, with standard bends, hooks or the like in shape : ("e." represents "exceeding" and "n.e." represents "not exceeding".) X (mm) : e.2500 but n.e.3000 Y (mm) : n.e. 1000 |
| 120239 | Hot dip galvanized dowels, 20 mm diameter high yield steel with X mm penetrated into existing structures or rock, embedded Y mm into buttress and the like as shown in Drawing No. C2203/1, with standard bends, hooks or the like in shape : ("e." represents "exceeding" and "n.e." represents "not exceeding".) X (mm) : e.3000 but n.e.3500 Y (mm) : n.e. 1000 |
| 120240 | Hot dip galvanized dowels, 20 mm diameter high yield steel with X mm penetrated into existing structures or rock, embedded Y mm into buttress and the like as shown in Drawing No. C2203/1, with standard bends, hooks or the like in shape :- ("e." represents "exceeding" and "n.e." represents "not exceeding".) X (mm) : n.e. 500 Y (mm) : e. 1000 but n.e. 1500 |
| 120241 | Hot dip galvanized dowels, 20 mm diameter high yield steel with X mm penetrated into existing structures or rock, embedded Y mm into buttress and the like as shown in Drawing No. C2203/1, with standard bends, hooks or the like in shape : ("e." represents "exceeding" and "n.e." represents "not exceeding".) X (mm) : e.500 but n.e.1000 Y (mm) : e. 1000 but n.e. 1500 |
| 120242 | Hot dip galvanized dowels, 20 mm diameter high yield steel with X mm penetrated into existing structures or rock, embedded Y mm into buttress and the like as shown in Drawing No. C2203/1, with standard bends, hooks or the like in shape : ("e." represents "exceeding" and "n.e." represents "not exceeding".) X (mm) : e.1000 but n.e.1500 Y (mm) : e. 1000 but n.e. 1500 |
| 120243 | Hot dip galvanized dowels, 20 mm diameter high yield steel with X mm penetrated into existing structures or rock, embedded Y mm into buttress and the like as shown in Drawing No. C2203/1, with standard bends, hooks or the like in shape :- ("e." represents "exceeding" and "n.e." represents "not exceeding".) X (mm) : e.1500 but n.e.2000 Y (mm) : e. 1000 but n.e. 1500 |
| 120244 | Hot dip galvanized dowels, 20 mm diameter high yield steel with X mm penetrated into existing structures or rock, embedded Y mm into buttress and the like as shown in Drawing No. C2203/1, with standard bends, hooks or the like in shape :- ("e." represents "exceeding" and "n.e." represents "not exceeding".) X (mm) : e.2000 but n.e.2500 Y (mm) : e. 1000 but n.e. 1500 |
| 120245 | Hot dip galvanized dowels, 20 mm diameter high yield steel with X mm penetrated into existing structures or rock, embedded Y mm into buttress and the like as shown in Drawing No. C2203/1, with standard bends, hooks or the like in shape :- ("e." represents "exceeding" and "n.e." represents "not exceeding".) X (mm) : e.2500 but n.e.3000 Y (mm) : e. 1000 but n.e. 1500 |
| 120246 | Hot dip galvanized dowels, 25 mm diameter high yield steel with X mm penetrated into existing structures or rock, embedded Y mm into buttress and the like as shown in Drawing No. C2203/1, with standard bends, hooks or the like in shape : - ("e." represents "exceeding" and "n.e." represents "not exceeding".) X (mm) : n.e. 500 Y (mm) : n.e. 1000 |
| 120247 | Hot dip galvanized dowels, 25 mm diameter high yield steel with X mm penetrated into existing structures or rock, embedded Y mm into buttress and the like as shown in Drawing No. C2203/1, with standard bends, hooks or the like in shape :- ("e." represents "exceeding" and "n.e." represents "not exceeding".) X (mm) : e.500 but n.e.1000 Y (mm) : n.e. 1000 |
| 120248 | Hot dip galvanized dowels, 25 mm diameter high yield steel with X mm penetrated into existing structures or rock, embedded Y mm into buttress and the like as shown in Drawing No. C2203/1, with standard bends, hooks or the like in shape :- ("e." represents "exceeding" and "n.e." represents "not exceeding".) X (mm) : e.1000 but n.e.1500 Y (mm) : n.e. 1000 |
| 120249 | Hot dip galvanized dowels, 25 mm diameter high yield steel with X mm penetrated into existing structures or rock, embedded Y mm into buttress and the like as shown in Drawing No. C2203/1, with standard bends, hooks or the like in shape :- ("e." represents "exceeding" and "n.e." represents "not exceeding".) X (mm) : e.1500 but n.e.2000 Y (mm) : n.e. 1000 |
| 120250 | Hot dip galvanized dowels, 25 mm diameter high yield steel with X mm penetrated into existing structures or rock, embedded Y mm into buttress and the like as shown in Drawing No. C2203/1, with standard bends, hooks or the like in shape :- ("e." represents "exceeding" and "n.e." represents "not exceeding".) X (mm) : e.2000 but n.e.2500 Y (mm) : n.e. 1000 |
| 120251 | Hot dip galvanized dowels, 25 mm diameter high yield steel with X mm penetrated into existing structures or rock, embedded Y mm into buttress and the like as shown in Drawing No. C2203/1, with standard bends, hooks or the like in shape :- ("e." represents "exceeding" and "n.e." represents "not exceeding".) X (mm) : e.2500 but n.e.3000 Y (mm) : n.e. 1000 |
| 120252 | Hot dip galvanized dowels, 25 mm diameter high yield steel with X mm penetrated into existing structures or rock, embedded Y mm into buttress and the like as shown in Drawing No. C2203/1, with standard bends, hooks or the like in shape :- ("e." represents "exceeding" and "n.e." represents "not exceeding".) X (mm) : e.3000 but n.e.3500 Y (mm) : n.e. 1000 |
| 120253 | Hot dip galvanized dowels, 25 mm diameter high yield steel with X mm penetrated into existing structures or rock, embedded Y mm into buttress and the like as shown in Drawing No. C2203/1, with standard bends, hooks or the like in shape :- ("e." represents "exceeding" and "n.e." represents "not exceeding".) X (mm) : n.e. 500 Y (mm) : e. 1000 but n.e. 1500 |
| 120254 | Hot dip galvanized dowels, 25 mm diameter high yield steel with X mm penetrated into existing structures or rock, embedded Y mm into buttress and the like as shown in Drawing No. C2203/1, with standard bends, hooks or the like in shape :- ("e." represents "exceeding" and "n.e." represents "not exceeding".) X (mm) : e.500 but n.e.1000 Y (mm) : e. 1000 but n.e. 1500 |
| 120255 | Hot dip galvanized dowels, 25 mm diameter high yield steel with X mm penetrated into existing structures or rock, embedded Y mm into buttress and the like as shown in Drawing No. C2203/1, with standard bends, hooks or the like in shape :- ("e." represents "exceeding" and "n.e." represents "not exceeding".) X (mm) : e.1000 but n.e.1500 Y (mm) : e. 1000 but n.e. 1500 |
| 120256 | Hot dip galvanized dowels, 25 mm diameter high yield steel with X mm penetrated into existing structures or rock, embedded Y mm into buttress and the like as shown in Drawing No. C2203/1, with standard bends, hooks or the like in shape :- ("e." represents "exceeding" and "n.e." represents "not exceeding".) X (mm) : e.1500 but n.e.2000 Y (mm) : e. 1000 but n.e. 1500 |
| 120257 | Hot dip galvanized dowels, 25 mm diameter high yield steel with X mm penetrated into existing structures or rock, embedded Y mm into buttress and the like as shown in Drawing No. C2203/1, with standard bends, hooks or the like in shape :- ("e." represents "exceeding" and "n.e." represents "not exceeding".) X (mm) : e.2000 but n.e.2500 Y (mm) : e. 1000 but n.e. 1500 |
| 120258 | Hot dip galvanized dowels, 25 mm diameter high yield steel with X mm penetrated into existing structures or rock, embedded Y mm into buttress and the like as shown in Drawing No. C2203/1, with standard bends, hooks or the like in shape :- ("e." represents "exceeding" and "n.e." represents "not exceeding".) X (mm) : e.2500 but n.e.3000 Y (mm) : e. 1000 but n.e. 1500 |
| 120259 | Hot dip galvanized dowels, 32 mm diameter high yield steel with X mm penetrated into existing structures or rock, embedded Y mm into buttress and the like as shown in Drawing No. C2203/1, with standard bends, hooks or the like in shape :- ("e." represents "exceeding" and "n.e." represents "not exceeding".) X (mm) : n.e. 500 Y (mm) : n.e. 1000 |
| 120260 | Hot dip galvanized dowels, 32 mm diameter high yield steel with X mm penetrated into existing structures or rock, embedded Y mm into buttress and the like as shown in Drawing No. C2203/1, with standard bends, hooks or the like in shape :- ("e." represents "exceeding" and "n.e." represents "not exceeding".) X (mm) : e.500 but n.e.1000 Y (mm) : n.e. 1000 |
| 120261 | Hot dip galvanized dowels, 32 mm diameter high yield steel with X mm penetrated into existing structures or rock, embedded Y mm into buttress and the like as shown in Drawing No. C2203/1, with standard bends, hooks or the like in shape : - ("e." represents "exceeding" and "n.e." represents "not exceeding".) X (mm) : e.1000 but n.e.1500 Y (mm) : n.e. 1000 |
| 120262 | Hot dip galvanized dowels, 32 mm diameter high yield steel with X mm penetrated into existing structures or rock, embedded Y mm into buttress and the like as shown in Drawing No. C2203/1, with standard bends, hooks or the like in shape :- ("e." represents "exceeding" and "n.e." represents "not exceeding".) X (mm) : e.1500 but n.e.2000 Y (mm) : n.e. 1000 |
| 120263 | Hot dip galvanized dowels, 32 mm diameter high yield steel with X mm penetrated into existing structures or rock, embedded Y mm into buttress and the like as shown in Drawing No. C2203/1, with standard bends, hooks or the like in shape :- ("e." represents "exceeding" and "n.e." represents "not exceeding".) X (mm) : e.2000 but n.e.2500 Y (mm) : n.e. 1000 |
| 120264 | Hot dip galvanized dowels, 32 mm diameter high yield steel with X mm penetrated into existing structures or rock, embedded Y mm into buttress and the like as shown in Drawing No. C2203/1, with standard bends, hooks or the like in shape :- ("e." represents "exceeding" and "n.e." represents "not exceeding".) X (mm) : e.2500 but n.e.3000 Y (mm) : n.e. 1000 |
| 120265 | Hot dip galvanized dowels, 32 mm diameter high yield steel with X mm penetrated into existing structures or rock, embedded Y mm into buttress and the like as shown in Drawing No. C2203/1, with standard bends, hooks or the like in shape : - ("e." represents "exceeding" and "n.e." represents "not exceeding".) X (mm) : e.3000 but n.e.3500 Y (mm) : n.e. 1000 |
| 120266 | Hot dip galvanized dowels, 32 mm diameter high yield steel with X mm penetrated into existing structures or rock, embedded Y mm into buttress and the like as shown in Drawing No. C2203/1, with standard bends, hooks or the like in shape : - ("e." represents "exceeding" and "n.e." represents "not exceeding".) X (mm) : n.e. 500 Y (mm) : e. 1000 but n.e. 1500 |
| 120267 | Hot dip galvanized dowels, 32 mm diameter high yield steel with X mm penetrated into existing structures or rock, embedded Y mm into buttress and the like as shown in Drawing No. C2203/1, with standard bends, hooks or the like in shape :- ("e." represents "exceeding" and "n.e." represents "not exceeding".) X (mm) : e.500 but n.e.1000 Y (mm) : e. 1000 but n.e. 1500 |
| 120268 | Hot dip galvanized dowels, 32 mm diameter high yield steel with X mm penetrated into existing structures or rock, embedded Y mm into buttress and the like as shown in Drawing No. C2203/1, with standard bends, hooks or the like in shape : - ("e." represents "exceeding" and "n.e." represents "not exceeding".) X (mm) : e.1000 but n.e.1500 Y (mm) : e. 1000 but n.e. 1500 |
| 120269 | Hot dip galvanized dowels, 32 mm diameter high yield steel with X mm penetrated into existing structures or rock, embedded Y mm into buttress and the like as shown in Drawing No. C2203/1, with standard bends, hooks or the like in shape :- ("e." represents "exceeding" and "n.e." represents "not exceeding".) X (mm) : e.1500 but n.e.2000 Y (mm) : e. 1000 but n.e. 1500 |
| 120270 | Hot dip galvanized dowels, 32 mm diameter high yield steel with X mm penetrated into existing structures or rock, embedded Y mm into buttress and the like as shown in Drawing No. C2203/1, with standard bends, hooks or the like in shape :- ("e." represents "exceeding" and "n.e." represents "not exceeding".) X (mm) : e.2000 but n.e.2500 Y (mm) : e. 1000 but n.e. 1500 |
| 120271 | Hot dip galvanized dowels, 32 mm diameter high yield steel with X mm penetrated into existing structures or rock, embedded Y mm into buttress and the like as shown in Drawing No. C2203/1, with standard bends, hooks or the like in shape : - ("e." represents "exceeding" and "n.e." represents "not exceeding".) X (mm) : e.2500 but n.e.3000 Y (mm) : e. 1000 but n.e. 1500 |
| 120272 | Establishment of equipment for soil nails and pull-out tests |
| 120273 | Moving equipment for soil nails and pull-out tests |
| 120274 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 or C2106/5 as specified, 25 mm diameter, in hole of 100 mm diameter, of length:- 3m |
| 120275 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 or C2106/5 as specified, 25 mm diameter, in hole of 100 mm diameter, of length :- 4m |
| 120276 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 or C2106/5 as specified, 25 mm diameter, in hole of 100 mm diameter, of length :- 5m |
| 120277 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 or C2106/5 as specified, 25 mm diameter, in hole of 100 mm diameter, of length :- 6m |
| 120278 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 or C2106/5 as specified, 25 mm diameter, in hole of 100 mm diameter, of length :- 7m |
| 120279 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 or C2106/5 as specified, 25 mm diameter, in hole of 100 mm diameter, of length :- 8m |
| 120280 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 or C2106/5 as specified, 25 mm diameter, in hole of 100 mm diameter, of length :- 9m |
| 120281 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 or C2106/5 as specified, 25 mm diameter, in hole of 100 mm diameter, of length :- 10m |
| 120282 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 or C2106/5 as specified, 25 mm diameter, in hole of 100 mm diameter, of length :- 11m |
| 120283 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 or C2106/5 as specified, 25 mm diameter, in hole of 100 mm diameter, of length :- 12m |
| 120284 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 or C2106/5 as specified, 25 mm diameter, in hole of 100 mm diameter, of length :- 13m |
| 120285 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 or C2106/5 as specified, 25 mm diameter, in hole of 100 mm diameter, of length :- 14m |
| 120286 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 or C2106/5 as specified, 25 mm diameter, in hole of 100 mm diameter, of length :- 15m |
| 120287 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 or C2106/5 as specified, 25 mm diameter, in hole of 100 mm diameter, of length :- 16m |
| 120288 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 or C2106/5 as specified, 25 mm diameter, in hole of 100 mm diameter, of length :- 17m |
| 120289 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 or C2106/5 as specified, 25 mm diameter, in hole of 100 mm diameter, of length :- 18m |
| 120290 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 or C2106/5 as specified, 25 mm diameter, in hole of 100 mm diameter, of length :- 19m |
| 120291 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 or C2106/5 as specified, 25 mm diameter, in hole of 100 mm diameter, of length :- 20m |
| 120292 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 100 mm diameter, of length :- 3m |
| 120293 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 100 mm diameter, of length :- 4m |
| 120294 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 100 mm diameter, of length :- 5m |
| 120295 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 100 mm diameter, of length :- 6m |
| 120296 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 100 mm diameter, of length :- 7m |
| 120297 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 100 mm diameter, of length :- 8m |
| 120298 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 100 mm diameter, of length :- 9m |
| 120299 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 100 mm diameter, of length :- 10m |
| 120300 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 100 mm diameter, of length :- 11m |
| 120301 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 100 mm diameter, of length :- 12m |
| 120302 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 100 mm diameter, of length :- 13m |
| 120303 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 100 mm diameter, of length :- 14m |
| 120304 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 100 mm diameter, of length :- 15m |
| 120305 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 100 mm diameter, of length :- 16m |
| 120306 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 100 mm diameter, of length :- 17m |
| 120307 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 100 mm diameter, of length :- 18m |
| 120308 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 100 mm diameter, of length :- 19m |
| 120309 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 100 mm diameter, of length :- 20m |
| 120310 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 150 mm diameter, of length :- 3m |
| 120311 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 150 mm diameter, of length :- 4m |
| 120312 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 150 mm diameter, of length :- 5m |
| 120313 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 150 mm diameter, of length :- 6m |
| 120314 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 150 mm diameter, of length :- 7m |
| 120315 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 150 mm diameter, of length :- 8m |
| 120316 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 150 mm diameter, of length :- 9m |
| 120317 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 150 mm diameter, of length :- 10m |
| 120318 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 150 mm diameter, of length :- 11m |
| 120319 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 150 mm diameter, of length :- 12m |
| 120320 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 150 mm diameter, of length :- 13m |
| 120321 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 150 mm diameter, of length :- 14m |
| 120322 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 150 mm diameter, of length :- 15m |
| 120323 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 150 mm diameter, of length :- 16m |
| 120324 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 150 mm diameter, of length :- 17m |
| 120325 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 150 mm diameter, of length :- 18m |
| 120326 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 150 mm diameter, of length :- 19m |
| 120327 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 150 mm diameter, of length :- 20m |
| 120328 | Soil nails, vertically downwards, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 150 mm diameter, of length :- 3m |
| 120329 | Soil nails, vertically downwards, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 150 mm diameter, of length :- 4m |
| 120330 | Soil nails, vertically downwards, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 150 mm diameter, of length :- 5m |
| 120331 | Soil nails, vertically downwards, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 150 mm diameter, of length :- 6m |
| 120332 | Soil nails, vertically downwards, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 150 mm diameter, of length :- 7m |
| 120333 | Soil nails, vertically downwards, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 150 mm diameter, of length :- 8m |
| 120334 | Soil nails, vertically downwards, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 150 mm diameter, of length :- 9m |
| 120335 | Soil nails, vertically downwards, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 150 mm diameter, of length :- 10m |
| 120336 | Soil nails, vertically downwards, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 150 mm diameter, of length :- 11m |
| 120337 | Soil nails, vertically downwards, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 150 mm diameter, of length :- 12m |
| 120338 | Soil nails, vertically downwards, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 150 mm diameter, of length :- 13m |
| 120339 | Soil nails, vertically downwards, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 150 mm diameter, of length :- 14m |
| 120340 | Soil nails, vertically downwards, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 150 mm diameter, of length :- 15m |
| 120341 | Soil nails, vertically downwards, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 150 mm diameter, of length :- 16m |
| 120342 | Soil nails, vertically downwards, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 150 mm diameter, of length :- 17m |
| 120343 | Soil nails, vertically downwards, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 150 mm diameter, of length :- 18m |
| 120344 | Soil nails, vertically downwards, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 150 mm diameter, of length :- 19m |
| 120345 | Soil nails, vertically downwards, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 25 mm diameter, in hole of 150 mm diameter, of length :- 20m |
| 120346 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 100 mm diameter, of length :- 3m |
| 120347 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 100 mm diameter, of length :- 4m |
| 120348 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 100 mm diameter, of length :- 5m |
| 120349 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 100 mm diameter, of length :- 6m |
| 120350 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 100 mm diameter, of length :- 7m |
| 120351 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 100 mm diameter, of length :- 8m |
| 120352 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 100 mm diameter, of length :- 9m |
| 120353 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 100 mm diameter, of length :- 10m |
| 120354 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 100 mm diameter, of length :- 11m |
| 120355 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 100 mm diameter, of length :- 12m |
| 120356 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 100 mm diameter, of length :- 13m |
| 120357 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 100 mm diameter, of length :- 14m |
| 120358 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 100 mm diameter, of length :- 15m |
| 120359 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 100 mm diameter, of length :- 16m |
| 120360 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 100 mm diameter, of length :- 17m |
| 120361 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 100 mm diameter, of length :- 18m |
| 120362 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 100 mm diameter, of length :- 19m |
| 120363 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 100 mm diameter, of length :- 20m |
| 120364 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 100 mm diameter, of length :- 3m |
| 120365 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 100 mm diameter, of length :- 4m |
| 120366 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 100 mm diameter, of length :- 5m |
| 120367 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 100 mm diameter, of length :- 6m |
| 120368 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 100 mm diameter, of length :- 7m |
| 120369 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 100 mm diameter, of length :- 8m |
| 120370 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 100 mm diameter, of length :- 9m |
| 120371 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 100 mm diameter, of length :- 10m |
| 120372 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 100 mm diameter, of length :- 11m |
| 120373 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 100 mm diameter, of length :- 12m |
| 120374 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 100 mm diameter, of length :- 13m |
| 120375 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 100 mm diameter, of length :- 14m |
| 120376 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 100 mm diameter, of length :- 15m |
| 120377 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 100 mm diameter, of length :- 16m |
| 120378 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 100 mm diameter, of length :- 17m |
| 120379 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 100 mm diameter, of length :- 18m |
| 120380 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 100 mm diameter, of length :- 19m |
| 120381 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 100 mm diameter, of length :- 20m |
| 120382 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 3m |
| 120383 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 4m |
| 120384 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 5m |
| 120385 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 6m |
| 120386 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 7m |
| 120387 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 8m |
| 120388 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 9m |
| 120389 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 10m |
| 120390 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 11m |
| 120391 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 12m |
| 120392 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 13m |
| 120393 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 14m |
| 120394 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 15m |
| 120395 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 16m |
| 120396 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 17m |
| 120397 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 18m |
| 120398 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 19m |
| 120399 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 20m |
| 120400 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 3m |
| 120401 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 4m |
| 120402 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 5m |
| 120403 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 6m |
| 120404 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 7m |
| 120405 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 8m |
| 120406 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 9m |
| 120407 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 10m |
| 120408 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 11m |
| 120409 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 12m |
| 120410 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 13m |
| 120411 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 14m |
| 120412 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 15m |
| 120413 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 16m |
| 120414 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 17m |
| 120415 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 18m |
| 120416 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 19m |
| 120417 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 20m |
| 120418 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 3m |
| 120419 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 4m |
| 120420 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 5m |
| 120421 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 6m |
| 120422 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 7m |
| 120423 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 8m |
| 120424 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 9m |
| 120425 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 10m |
| 120426 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 11m |
| 120427 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 12m |
| 120428 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 13m |
| 120429 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 14m |
| 120430 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 15m |
| 120431 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 16m |
| 120432 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 17m |
| 120433 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 18m |
| 120434 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 19m |
| 120435 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 32 mm diameter, in hole of 150 mm diameter, of length :- 20m |
| 120436 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 100 mm diameter, of length :- 3m |
| 120437 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 100 mm diameter, of length :- 4m |
| 120438 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 100 mm diameter, of length :- 5m |
| 120439 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 100 mm diameter, of length :- 6m |
| 120440 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 100 mm diameter, of length :- 7m |
| 120441 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 100 mm diameter, of length :- 8m |
| 120442 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 100 mm diameter, of length :- 9m |
| 120443 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 100 mm diameter, of length :- 10m |
| 120444 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 100 mm diameter, of length :- 11m |
| 120445 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 100 mm diameter, of length :- 12m |
| 120446 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 100 mm diameter, of length :- 13m |
| 120447 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 100 mm diameter, of length :- 14m |
| 120448 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 100 mm diameter, of length :- 15m |
| 120449 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 100 mm diameter, of length :- 16m |
| 120450 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 100 mm diameter, of length :- 17m |
| 120451 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 100 mm diameter, of length :- 18m |
| 120452 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 100 mm diameter, of length :- 19m |
| 120453 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 100 mm diameter, of length :- 20m |
| 120454 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 3m |
| 120455 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 4m |
| 120456 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 5m |
| 120457 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 6m |
| 120458 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 7m |
| 120459 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 8m |
| 120460 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 9m |
| 120461 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 10m |
| 120462 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 11m |
| 120463 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 12m |
| 120464 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 13m |
| 120465 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 14m |
| 120466 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 15m |
| 120467 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 16m |
| 120468 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 17m |
| 120469 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 18m |
| 120470 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 19m |
| 120471 | Soil nails, horizontally or downwards at angle less than 85o to the horizontal, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 20m |
| 120472 | Soil nails, horizontally or downwards at an angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 3 m |
| 120473 | Soil nails, horizontally or downwards at an angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 4 m |
| 120474 | Soil nails, horizontally or downwards at an angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 5 m |
| 120475 | Soil nails, horizontally or downwards at an angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 6 m |
| 120476 | Soil nails, horizontally or downwards at an angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 7 m |
| 120477 | Soil nails, horizontally or downwards at an angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 8 m |
| 120478 | Soil nails, horizontally or downwards at an angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 9 m |
| 120479 | Soil nails, horizontally or downwards at an angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 10 m |
| 120480 | Soil nails, horizontally or downwards at an angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 11 m |
| 120481 | Soil nails, horizontally or downwards at an angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 12 m |
| 120482 | Soil nails, horizontally or downwards at an angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 13 m |
| 120483 | Soil nails, horizontally or downwards at an angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 14 m |
| 120484 | Soil nails, horizontally or downwards at an angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 15 m |
| 120485 | Soil nails, horizontally or downwards at an angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 16 m |
| 120486 | Soil nails, horizontally or downwards at an angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 17 m |
| 120487 | Soil nails, horizontally or downwards at an angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 18 m |
| 120488 | Soil nails, horizontally or downwards at an angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of lengthh :- 19 m |
| 120489 | Soil nails, horizontally or downwards at an angle less than 85o to the horizontal, with double corrosion protection as shown in Sketch No. R1043/3 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 20 m |
| 120490 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 3 m |
| 120491 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 4 m |
| 120492 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 5 m |
| 120493 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 6 m |
| 120494 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 7 m |
| 120495 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 8 m |
| 120496 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 9 m |
| 120497 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 10 m |
| 120498 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 11 m |
| 120499 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 12 m |
| 120500 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 13 m |
| 120501 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 14 m |
| 120502 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 15 m |
| 120503 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 16 m |
| 120504 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 17 m |
| 120505 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 18 m |
| 120506 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 19 m |
| 120507 | Soil nails, vertically downwards, as shown in Drawing No. C2106/1 with 400 mm x 400 mm soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 as specified, 40 mm diameter, in hole of 150 mm diameter, of length :- 20 m |
| 120508 | Pull-out Test |
| 120509 | Extra over for enlarged soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 with size : - 600 mm x 600 mm |
| 120510 | Extra over for enlarged soil nail head as shown in Drawing Nos. C2106/2, C2106/3, C2106/4 and C2106/5 with size : - 800 mm x 800 mm |
| 120511 | Extra over for completing the grouting of soil nails with excessive grout loss |
| 120512 | Extra over for 6.3 mm thick permanent steel casing for soil nail of internal diameter:- 100 mm |
| 120513 | Extra over for 6.3 mm thick permanent steel casing for soil nail of internal diameter:- 150 mm |
| 120514 | Extra over for forming holes for soil nail by coring for hole of internal diameter :- 100 mm |
| 120515 | Extra over for forming holes for soil nail by coring for hole of internal diameter :- 150 mm |
| 120516 | Removal of Existing Masonry Facing for Soil Nail Head Construction with size :- 400 mm x 400 mm soil nail head |
| 120517 | Removal of Existing Masonry Facing for Soil Nail Head Construction with size :- 600 mm x 600 mm soil nail head |
| 120518 | Removal of Existing Masonry Facing for Soil Nail Head Construction with size :- 800 mm x 800 mm soil nail head |
| 120519 | Reinstatement of Existing Masonry Facing for Soil Nail Head Construction with size :- 400 mm x 400 mm soil nail head |
| 120520 | Reinstatement of Existing Masonry Facing for Soil Nail Head Construction with size :- 600 mm x 600 mm soil nail head |
| 120521 | Reinstatement of Existing Masonry Facing for Soil Nail Head Construction with size :- 800 mm x 800 mm soil nail head |
| 120522 | Time domain reflectometry test |
| 120523 | Taking vibration readings |
| 120524 | Construct tree rings with sprayed concrete as shown in Drawing No. C2104, with average inner diameter :- :- Not exceeding 800 mm |
| 120525 | Construct tree rings with sprayed concrete as shown in Drawing No. C2104, with average inner diameter :- :- Exceeding 800 mm but not exceeding 1200 mm |
| 120526 | Construct tree rings with sprayed concrete as shown in Drawing No. C2104, with average inner diameter :- Exceeding 1200 mm but not exceeding 1800 mm |
| 120527 | Construct tree rings with sprayed concrete as shown in Drawing No. C2104, with average inner diameter :- Exceeding 1800 mm but not exceeding 2400 mm |
| 120528 | Construct tree rings with sprayed concrete as shown in Drawing No. C2104, with average inner diameter :- Exceeding 2400 mm but not exceeding 3000 mm |
| 120529 | Construct tree rings with sprayed concrete as shown in Drawing No. C2104, with average inner diameter :- Exceeding 3000mm but not exceeding 3600 mm |
| 120530 | Mats for erosion control :- Polyamide type |
| 120531 | Mats for erosion control :- Polyethylene type |
| 120532 | Mats for erosion control :- Polypropylene type |
| 120533 | Mats for erosion control :- Composite Polypropylene or Polyethylene |
| 120534 | Mats for erosion control : Natural coir type :- Minimum average weight : 400 g/m2 |
| 120535 | Mats for erosion control : Natural coir type :- Minimum average weight : 740 g/m2 |
| 120536 | Mats for erosion control : Natural coir type :- Minimum average weight : 900 g/m2 |
| 120537 | Mats for erosion control : Natural jute fibre type :- Minimum average weight : 500 g/m2 |
| 120538 | Mats for erosion control : Natural jute fibre type :- Minimum average weight : 750 g/m2 |
| 120539 | Mats for erosion control : Natural jute fibre type :- Minimum average weight : 1,000 g/m2 |
| 120540 | Wire mesh for erosion control as shown in Drawing Nos. C2511/1 and C2511/2 |
| 120541 | "Bonded Soil-Fibre Matrix" with a rate of 1,360-3,625 kg per acre or products having equivalent functions and performance |
| 120542 | "Soil Filled Panel" 200 mm thick or approved products having equivalent functions and performance |
| 120543 | "Fibre-reinforced Soil" 300 mm thick or approved products having equivalent functions and performance |
| 120544 | Sand bags 300 mm x 750 mm Supply sand bags |
| 120545 | Sand bags 300 mm x 750 mm Fill sand and lay sand bags |
| 120546 | Sand bags 300 mm x 750 mm Removal of sand bags to dump |
| 120547 | Canvas bags 250 mm x 400 mm Supply canvas bags |
| 120548 | Canvas bags 250 mm x 400 mm Fill sand and lay canvas bags |
| 120549 | Canvas bags 250 mm x 400 mm Removal of canvas bags to dump |
| 120550 | Supply and fix, ‘rock cage’ as shown in Drawing No. SK 2953/5 |
| 120551 | Extra over Item No. 120/550 for supplying rock from sources outside 180 m from place of erection |
| 120552 | Take down rock cages and dispose of cages and rock |
| 120553 | Take down rock cages and dispose of cages only. Rock to be cleaned and stacked on site for re-use. |
| 120554 | Supply and fix to reservoir bank, Tensar Gm-4 gabion or approved equivalent, gabion size 6 m x 2 m x 0.3 m |
| 120555 | Extra over Item No. 120/554 for supplying rock from sources outside 180 m from place of erection |
| 120556 | Supply and lay plastic filter fabric to reservoir bank and surfaces of slopes as directed |
| 120557 | Supply and lay plastic filter fabric over single-sized aggregate on service reservoir roof |
| 120558 | Weepholes in No-fines Concrete 50 mm diameter perforated P.V.C. pipes wrapped around in geotextile filter |
| 120559 | Weepholes in No-fines Concrete 75 mm diameter perforated P.V.C. pipes wrapped around in geotextile filter |
| 121001 | Cut-off drain 225 mm diameter, depth to invert not exceeding 1.5 m as shown in Drawing No. C2401 |
| 121002 | Ditto, depth to invert exceeding 1.5 m but not exceeding 2.5 m |
| 121003 | Ditto, depth to invert exceeding 2.5 m but not exceeding 3.5 m |
| 121004 | Counterfort drain 150 mm diameter, depth to invert not exceeding 1.5 m as shown in Sketch No. R1060 |
| 121005 | Ditto, depth to invert exceeding 1.5 m but not exceeding 2.5 m |
| 121006 | Connections to existing sewers, grey water, collection pipe, drains, ducts, trench drains, culverts, watercourses, manholes, other chambers and drawpits, diameter:- 100 mm |
| 121007 | Connections to existing sewers, grey water, collection pipe, drains, ducts, trench drains, culverts, watercourses, manholes, other chambers and drawpits, diameter:- 150 mm |
| 121008 | Connections to existing sewers, grey water, collection pipe, drains, ducts, trench drains, culverts, watercourses, manholes, other chambers and drawpits, diameter:- 225 mm |
| 121009 | Connections to existing sewers, grey water, collection pipe, drains, ducts, trench drains, culverts, watercourses, manholes, other chambers and drawpits, diameter:- 300 mm |
| 121010 | Connections to existing sewers, grey water, collection pipe, drains, ducts, trench drains, culverts, watercourses, manholes, other chambers and drawpits, diameter:- 375 mm |
| 121011 | Connections to existing sewers, grey water, collection pipe, drains, ducts, trench drains, culverts, watercourses, manholes, other chambers and drawpits, diameter:- 450 mm |
| 121012 | Connections to existing sewers, grey water, collection pipe, drains, ducts, trench drains, culverts, watercourses, manholes, other chambers and drawpits, diameter:- 525 mm |
| 121013 | Connections to existing sewers, grey water, collection pipe, drains, ducts, trench drains, culverts, watercourses, manholes, other chambers and drawpits, diameter:- 600 mm |
| 121014 | Standard manhole Type C as shown in DSD Standard Drawing No. DS1003 and DS1078 with heavy duty cover and frames, depth to invert not exceeding 1.5 m |
| 121015 | Ditto, depth exceeding 1.50 m but not exceeding 2.50 m |
| 121016 | Standard manhole Type D as shown in DSD Standard Drawing No. DS1004 and DS1079 with heavy duty cover and frames, depth to invert not exceeding 1.5 m |
| 121017 | Ditto, depth exceeding 1.5m but not exceeding 2.50 m |
| 121017a | Standard manhole Type E or E1 as shown in DSD Standard Drawing No. DS1005 and DS1080 with heavy duty cover and frames, depth to invert not exceeding 1.5m |
| 121017b | Ditto, depth exceeding 1.5m but not exceeding 2.50 m |
| 121017c | Ditto, depth exceeding 2.5m but not exceeding 3.50 m |
| 121017d | Standard manhole Type F or F1 as shown in DSD Standard Drawing No. DS1006 and DS1081 with heavy duty cover and frames, depth to invert not exceeding 2.5m |
| 121017e | Ditto, depth exceeding 2.5m but not exceeding 3.50 m |
| 121017f | Ditto, depth exceeding 3.5m but not exceeding 4.50 m |
| 121017g | Standard manhole Type L as shown in DSD Standard Drawing No. DS1017 with heavy duty cover and frames, depth to invert not exceeding 3.50m |
| 121017h | Ditto, depth exceeding 3.50m but not exceeding 4.50 m |
| 121017i | Ditto, depth exceeding 4.50m but not exceeding 5.50 m |
| 121017j | Ditto, depth exceeding 5.50m but not exceeding 6.50 m |
| 121018 | Catchpits with trap as shown in Drawing No. C2406 with precast concrete cover, depth to invert not exceeding 1.5 m |
| 121019 | Ditto, depth to invert exceeding 1.5 m but not exceeding 2.5 m |
| 121020 | Catchpits with trap as shown in Drawing No. C2406 without cover, depth to invert not exceeding 1.5 m |
| 121021 | Ditto, depth to invert exceeding 1.5 m but not exceeding 2.5 m |
| 121022 | Catchpits as shown in Drawing No. C2405 with precast concrete cover, depth to invert not exceeding 1.5 m |
| 121023 | Catchpits as shown in Drawing No. C2405 without cover, depth to invert not exceeding 1.5m |
| 121024 | Manhole for cut-off drain as shown in Drawing No. C2402, depth to invert not exceeding 1.5 m |
| 121025 | Ditto, depth to invert exceeding 1.5 m but not exceeding 2.5 m |
| 121026 | Trash rack and downspout assembly as shown in Drawing No. C2408, with precast concrete cover, depth to invert not exceeding 1.5 m |
| 121027 | Ditto, depth to invert exceeding 1.5 m but not exceeding 2.5 m |
| 121028 | Half round channels, as shown in Drawing No. C2409, nominal size:- 150 mm |
| 121029 | Half round channels, as shown in Drawing No. C2409, nominal size:- 225 mm |
| 121030 | Half round channels, as shown in Drawing No. C2409, nominal size:- 300 mm |
| 121031 | U-channels Type A, as shown in Drawing Nos. C2409 and C2413 with masonry apron, nominal size:- 225 mm |
| 121032 | U-channels Type A, as shown in Drawing Nos. C2409 and C2413 with masonry apron, nominal size:- 300 mm |
| 121033 | U-channels Type A, as shown in Drawing Nos. C2409 and C2413 with masonry apron, nominal size:- 375 mm |
| 121034 | U-channels Type A, as shown in Drawing Nos. C2409 and C2413 with masonry apron, nominal size:- 450 mm |
| 121035 | U-channels Type A, as shown in Drawing Nos. C2409 and C2413 with masonry apron, nominal size:- 525 mm |
| 121036 | U-channels Type A, as shown in Drawing Nos. C2409 and C2413 with masonry apron, nominal size:- 600 mm |
| 121037 | U-channels Type A, as shown in Drawing Nos. C2409 and C2413 with masonry apron, nominal size:- 675 mm |
| 121038 | U-channels Type A, as shown in Drawing Nos. C2409 and C2413 with masonry apron, nominal size:- 750 mm |
| 121039 | U-channels Type A, as shown in Drawing Nos. C2409 and C2413 with masonry apron, nominal size:- 900 mm |
| 121040 | U-channels Type A, as shown in Drawing Nos. C2409, C2412 and C2413 with masonry apron and precast concrete slab, nominal size:- 225 mm |
| 121041 | U-channels Type A, as shown in Drawing Nos. C2409, C2412 and C2413 with masonry apron and precast concrete slab, nominal size:- 300 mm |
| 121042 | U-channels Type A, as shown in Drawing Nos. C2409, C2412 and C2413 with masonry apron and precast concrete slab, nominal size:- 375 mm |
| 121043 | U-channels Type A, as shown in Drawing Nos. C2409, C2412 and C2413 with masonry apron and precast concrete slab, nominal size:- 450 mm |
| 121044 | U-channels Type A, as shown in Drawing Nos. C2409, C2412 and C2413 with masonry apron and precast concrete slab, nominal size:- 525 mm |
| 121045 | U-channels Type A, as shown in Drawing Nos. C2409, C2412 and C2413 with masonry apron and cast iron grating, nominal size:- 225 mm |
| 121046 | U-channels Type A, as shown in Drawing Nos. C2409, C2412 and C2413 with masonry apron and cast iron grating, nominal size:- 300 mm |
| 121047 | U-channels Type A, as shown in Drawing Nos. C2409, C2412 and C2413 with masonry apron and cast iron grating, nominal size:- 375 mm |
| 121048 | U-channels Type A, as shown in Drawing Nos. C2409, C2412 and C2413 with masonry apron and cast iron grating, nominal size:- 450 mm |
| 121049 | U-channels Type B, as shown in Drawing Nos. C2410 and C2413 with erosion control mat apron, nominal size:- 225 mm |
| 121050 | U-channels Type B, as shown in Drawing Nos. C2410 and C2413 with erosion control mat apron, nominal size:- 300 mm |
| 121051 | U-channels Type B, as shown in Drawing Nos. C2410 and C2413 with erosion control mat apron, nominal size:- 375 mm |
| 121052 | U-channels Type B, as shown in Drawing Nos. C2410 and C2413 with erosion control mat apron, nominal size:- 450 mm |
| 121053 | U-channels Type B, as shown in Drawing Nos. C2410 and C2413 with erosion control mat apron, nominal size:- 525 mm |
| 121054 | U-channels Type B, as shown in Drawing Nos. C2410 and C2413 with erosion control mat apron, nominal size:- 600 mm |
| 121055 | U-channels Type B, as shown in Drawing Nos. C2410 and C2413 with erosion control mat apron, nominal size:- 675 mm |
| 121056 | U-channels Type B, as shown in Drawing Nos. C2410 and C2413 with erosion control mat apron, nominal size:- 750 mm |
| 121057 | U-channels Type B, as shown in Drawing Nos. C2410 and C2413 with erosion control mat apron, nominal size:- 900 mm |
| 121058 | U-channels Type B, as shown in Drawing Nos. C2410, C2412 and C2413 with erosion control mat apron and precast concrete slab, nominal size:- 225 mm |
| 121059 | U-channels Type B, as shown in Drawing Nos. C2410, C2412 and C2413 with erosion control mat apron and precast concrete slab, nominal size:- 300 mm |
| 121060 | U-channels Type B, as shown in Drawing Nos. C2410, C2412 and C2413 with erosion control mat apron and precast concrete slab, nominal size:- 375 mm |
| 121061 | U-channels Type B, as shown in Drawing Nos. C2410, C2412 and C2413 with erosion control mat apron and precast concrete slab, nominal size:- 450 mm |
| 121062 | U-channels Type B, as shown in Drawing Nos. C2410, C2412 and C2413 with erosion control mat apron and precast concrete slab, nominal size:- 525 mm |
| 121063 | U-channels Type B, as shown in Drawing Nos. C2410, C2412 and C2413 with erosion control mat apron and cast iron grating, nominal size:- 225 mm |
| 121064 | U-channels Type B, as shown in Drawing Nos. C2410, C2412 and C2413 with erosion control mat apron and cast iron grating, nominal size:- 300 mm |
| 121065 | U-channels Type B, as shown in Drawing Nos. C2410, C2412 and C2413 with erosion control mat apron and cast iron grating, nominal size:- 375 mm |
| 121066 | U-channels Type B, as shown in Drawing Nos. C2410, C2412 and C2413 with erosion control mat apron and cast iron grating, nominal size:- 450 mm |
| 121067 | U-channels, as shown in Drawing Nos. C2509 and C2413 with concrete apron and upstand, nominal size:- 225 mm |
| 121068 | U-channels, as shown in Drawing Nos. C2509 and C2413 with concrete apron and upstand, nominal size:- 300 mm |
| 121069 | U-channels, as shown in Drawing Nos. C2509 and C2413 with concrete apron and upstand, nominal size:- 375 mm |
| 121070 | U-channels, as shown in Drawing Nos. C2509 and C2413 with concrete apron and upstand, nominal size:- 450 mm |
| 121071 | U-channels, as shown in Drawing Nos. C2509 and C2413 with concrete apron and upstand, nominal size:- 525 mm |
| 121072 | U-channels, as shown in Drawing Nos. C2509 and C2413 with concrete apron and upstand, nominal size:- 600 mm |
| 121073 | U-channels, as shown in Drawing Nos. C2509 and C2413 with concrete apron and upstand, nominal size:- 675 mm |
| 121073a | U channels alongside access road/pavement with kerb inlet of length not exceeding 1.3m and at intervals equal to or exceeding 8m, as shown in Drawing Nos. WSD 5.3, WSD 5.4 and C2410, nominal size:-225mm |
| 121073b | U channels alongside access road/pavement with kerb inlet of length not exceeding 1.3m and at intervals equal to or exceeding 8m, as shown in Drawing Nos. WSD 5.3, WSD 5.4 and C2410, nominal size:-300mm |
| 121073c | U channels alongside access road/pavement with kerb inlet of length not exceeding 1.3m and at intervals equal to or exceeding 8m, as shown in Drawing Nos. WSD 5.3, WSD 5.4 and C2410, nominal size:-375 mm |
| 121073d | U channels alongside access road/pavement with kerb inlet of length not exceeding 1.3m and at intervals equal to or exceeding 8m, as shown in Drawing Nos. WSD 5.3, WSD 5.4 and C2410, nominal size:-450 mm |
| 121073e | U channels alongside access road/pavement with kerb inlet of length not exceeding 1.3m and at intervals equal to or exceeding 8m, as shown in Drawing Nos. WSD 5.3, WSD 5.4 and C2410, nominal size:-525 mm |
| 121073f | U channels alongside access road/pavement with kerb inlet of length not exceeding 1.3m and at intervals equal to or exceeding 8m, as shown in Drawing Nos. WSD 5.3, WSD 5.4 and C2410, nominal size:-600 mm |
| 121073g | U channels alongside access road/pavement with kerb inlet of length not exceeding 1.3m and at intervals equal to or exceeding 8m, as shown in Drawing Nos. WSD 5.3, WSD 5.4 and C2410, nominal size:-675 mm |
| 121073h | U channels alongside access road/pavement with kerb inlet of length not exceeding 1.3m and at intervals equal to or exceeding 8m, as shown in Drawing Nos. WSD 5.3, WSD 5.4 and C2410, nominal size:-750 mm |
| 121073i | U channels alongside access road/pavement with kerb inlet of length not exceeding 1.3m and at intervals equal to or exceeding 8m, as shown in Drawing Nos. WSD 5.3, WSD 5.4 and C2410, nominal size:-900 mm |
| 121074 | Stepped channels, as shown in Drawing Nos. C2411 and C2413 nominal size:- 225 mm |
| 121075 | Stepped channels, as shown in Drawing Nos. C2411 and C2413 nominal size:- 300 mm |
| 121076 | Stepped channels, as shown in Drawing Nos. C2411 and C2413 nominal size:- 375 mm |
| 121077 | Stepped channels, as shown in Drawing Nos. C2411 and C2413 nominal size:- 450 mm |
| 121078 | Stepped channels, as shown in Drawing Nos. C2411 and C2413 nominal size:- 525 mm |
| 121079 | Stepped channels, as shown in Drawing Nos. C2411 and C2413 nominal size:- 600 mm |
| 121080 | Stepped channels, as shown in Drawing Nos. C2411 and C2413 nominal size:- 675 mm |
| 121081 | Stepped channels, as shown in Drawing Nos. C2411 and C2413 nominal size:- 750 mm |
| 121082 | Stepped channels, as shown in Drawing Nos. C2411 and C2413 nominal size:- 900 mm |
| 121083 | Baffle wall not exceeding 300 mm thick, height not exceeding 1500 mm |
| 121083a | Stepped channels alongside access road/pavement with kerb inlet of length not exceeding 1.3m and at intervals equal to or exceeding 8m, as shown in Drawing Nos. WSD 5.3, WSD 5.4 and C2411, nominal size:-225mm |
| 121083b | Stepped channels alongside access road/pavement with kerb inlet of length not exceeding 1.3m and at intervals equal to or exceeding 8m, as shown in Drawing Nos. WSD 5.3, WSD 5.4 and C2411, nominal size:-300mm |
| 121083c | Stepped channels alongside access road/pavement with kerb inlet of length not exceeding 1.3m and at intervals equal to or exceeding 8m, as shown in Drawing Nos. WSD 5.3, WSD 5.4 and C2411, nominal size:-375 mm |
| 121083d | Stepped channels alongside access road/pavement with kerb inlet of length not exceeding 1.3m and at intervals equal to or exceeding 8m, as shown in Drawing Nos. WSD 5.3, WSD 5.4 and C2411, nominal size:-450 mm |
| 121083e | Stepped channels alongside access road/pavement with kerb inlet of length not exceeding 1.3m and at intervals equal to or exceeding 8m, as shown in Drawing Nos. WSD 5.3, WSD 5.4 and C2411, nominal size:-525 mm |
| 121083f | Stepped channels alongside access road/pavement with kerb inlet of length not exceeding 1.3m and at intervals equal to or exceeding 8m, as shown in Drawing Nos. WSD 5.3, WSD 5.4 and C2411, nominal size:-600 mm |
| 121083g | Stepped channels alongside access road/pavement with kerb inlet of length not exceeding 1.3m and at intervals equal to or exceeding 8m, as shown in Drawing Nos. WSD 5.3, WSD 5.4 and C2411, nominal size:-675 mm |
| 121083h | Stepped channels alongside access road/pavement with kerb inlet of length not exceeding 1.3m and at intervals equal to or exceeding 8m, as shown in Drawing Nos. WSD 5.3, WSD 5.4 and C2411, nominal size:-750 mm |
| 121083i | Stepped channels alongside access road/pavement with kerb inlet of length not exceeding 1.3m and at intervals equal to or exceeding 8m, as shown in Drawing Nos. WSD 5.3, WSD 5.4 and C2411, nominal size:-900 mm |
| 121084 | Supports Left in Excavation; Trench support of any type left in pit or trench |
| 121085 | Drainage Layers; 300 mm thick no-fines concrete drainage layers |
| 121086 | Granular Filters; Coarse granular filter (Filter B) |
| 121087 | Granular Filters; Fine granular filter (Filter A) |
| 121088 | Geotextile filter Tafnel U60 or products having equivalent functions and performance |
| 121089 | Geotextile filter Miradrain 5000 or products having equivalent functions and performance |
| 121090 | Geotextile filter Miradrain 6000 or products having equivalent functions and performance |
| 121091 | Geotextile filter Miradrain 9000 or products having equivalent functions and performance |
| 121092 | Filter drainage pipe as shown in Drawing No. C2302, 50 mm diameter, length not exceeding 3.00 m |
| 121093 | Filter drainage pipe as shown in Drawing No. C2302, 50 mm diameter, for length exceeding 3.00 m but not exceeding 6.00 m |
| 121094 | Perforated UPVC sub-soil drainage pipe, wrapped by geotextile filter, diameter: - 75mm diameter |
| 121095 | Perforated UPVC sub-soil drainage pipe, wrapped by geotextile filter, diameter: - 150mm diameter |
| 121096 | Perforated UPVC sub-soil drainage pipe, wrapped by geotextile filter, diameter: - 225mm diameter |
| 121096a | Perforated UPVC sub-soil drainage pipe, wrapped by geotextile filter, diameter: -300mm diameter |
| 121097 | Perforated UPVC sub-soil drainage pipe, wrapped by geotextile filter, diameter: - 375mm diameter |
| 122001 | Ground cleaning |
| 122002 | Scarifying, 10 mm to 20 mm deep |
| 122003 | Ripping, 300 mm deep |
| 122004 | Cultivation, 150 mm deep |
| 122005 | Soiling with soil-mix, 300 mm thick |
| 122006 | Soiling with soil-mix, 450 mm thick |
| 122007 | Soiling with soil-mix, 600 mm thick |
| 122008 | Soiling with soil-mix, 800 mm thick |
| 122009 | Soiling with soil-mix, 1000 mm thick |
| 122010 | Soil conditioners, to form 300 mm thick soil-mix |
| 122011 | Soil conditioners, to form 600 mm thick soil-mix |
| 122012 | Soil conditioners, to form 1000 mm thick soil-mix |
| 122012a | Extra over items 122/005 to 009 for soiling with light-weight soil-mix |
| 122012b | Soiling with imported subsoil |
| 122013 | Establishment of equipment for hydroseeding |
| 122014 | Hydroseeding, with grass seed mix (including protective fabric material) |
| 122014a | Hydroseeding, with grass seed mix (excluding protective fabric material) |
| 122015 | Hydroseeding, with grass seed and tree seed mix (including protective fabric material) |
| 122015a | Hydroseeding, with grass seed and tree seed mix (excluding protective fabric material) |
| 122015b | Hydroseeding, with grass seed and herbaceous/shrubs seed mix (including protective fabric material) |
| 122016 | Hydroseeding, with grass seed and herbaceous/shrubs seed mix (excluding protective fabric material) |
| 122016a | Sprigging |
| 122016b | Broadcast seeding |
| 122016c | Turfing of species 75-85% Axonopus compressus and 15-25% Cynodon dactylon |
| 122016d | Turfing of species 55-65% Axonopus compressus, 10-20% Cynodon dactylon, 10% Eremochloa ophiuroides and 15% Leptochloa chinensis |
| 122016e | Turfing of species Axonopus compressus |
| 122016f | Turfing of species Cynodon dactylon |
| 122016g | Turfing of species Cynodon hybrid ‘Tifton 419’ |
| 122016h | Turfing of species Paspalum vaginatum |
| 122016i | Turfing of species Eremochloa ophiuroides |
| 122016j | Turfing of species Zoysia matrella |
| 122016k | Turfing of species Zoysia japonica |
| 122017 | Establishment of equipment for hydromulching |
| 122018 | Hydromulching |
| 122018a | Semi-mature trees, Group A |
| 122018b | Semi-mature trees, Group B |
| 122018c | Semi-mature trees, Group C |
| 122019 | Heavy standard trees, Group A |
| 122019a | Heavy standard trees, Group B |
| 122019b | Heavy standard trees, Group C |
| 122020 | Standard trees, Group A |
| 122020a | Standard trees, Group B |
| 122020b | Standard trees, Group C |
| 122021 | Light standard trees, Group A |
| 122021a | Light standard trees, Group B |
| 122021b | Light standard trees, Group C |
| 122022 | Whip trees, Group A |
| 122022a | Whip trees, Group B |
| 122022b | Whip trees, Group C |
| 122023 | Seedling trees, Group A |
| 122023a | Seedling trees, Group B |
| 122023b | Seedling trees, Group C |
| 122024 | Planting Works, Large conifers |
| 122025 | Planting Works, Small conifers |
| 122026 | Planting Works, Large palms, Group A |
| 122027 | Planting Works, Large palms, Group B |
| 122028 | Planting Works, Large palms, Group C |
| 122029 | Planting Works, Large palms, Group D |
| 122030 | Planting Works, Medium palms, Group A |
| 122031 | Planting Works, Medium palms, Group B |
| 122032 | Planting Works, Medium palms, Group C |
| 122033 | Planting Works, Medium palms, Group D |
| 122034 | Planting Works, Medium palms, Group E |
| 122035 | Planting Works, Small palms, Group A |
| 122036 | Planting Works, Small palms, Group B |
| 122037 | Planting Works, Small palms, Group C |
| 122038 | Planting Works, Small palms, Group D |
| 122039 | Planting Works, Small palms, Group E |
| 122040 | Planting Works, Large bamboos |
| 122041 | Planting Works, Small bamboos |
| 122042 | Planting Works, Large shrubs |
| 122043 | Planting Works, Small shrubs |
| 122044 | Planting Works, Ground covers or herbaceous plants, Group A |
| 122044a | Planting Works, Ground covers or herbaceous plants, Group B |
| 122045 | Planting Works, Climbers |
| 122045a | Planting Works, Seasonal flowers |
| 122045b | Planting Works, Small topiary plants |
| 122045c | Planting Works, Large topiary plants |
| 122046 | Planter tubes/holes for ground covers or hebaceous |
| 122047 | Planters tubes/holes for climbers or shrubs |
| 122048 | (Not used)Biocrete System or system having equivalent functions and performance approved. |
| 122049 | (Not used)Instant Evergreen Panel 60 or system having equivalent functions and performance approved. |
| 122050 | (Not used)Instant Evergreen Panel 80 or system having equivalent functions and performance approved. |
| 122051 | (Not used)Rocksgrass System or system having equivalent functions and performance approved. |
| 122052 | (Not used)Eco-Link System or system having equivalent functions and performance approved. |
| 122053 | (Not used)Vetiver Grass Biodrains System or system having equivalent functions and performance approved. |
| 122054 | (Not used)Geofibre or system having equivalent functions and performance approved. |
| 122055 | (Not used)Secumat Muti Layer Green System or system having equivalent functions and performance approved. |
| 122056 | (Not used)Eco-MP System or system having equivalent functions and performance approved. |
| 122057 | (Not used)Green Wall Beautifying Wall System or bio-engineering greening system on hard surface (BGS-HS) system having equivalent functions and performance approved. |
| 122058 | Basic establishment operations for hydroseeded /hydromulched areas. |
| 122058a | Basic establishment operations for turfing, sprigging or broadcast seeding areas. |
| 122058b | Basic establishment operations for semi-mature trees |
| 122059 | Basic establishment operations for heavy standard trees, large palms, large conifers or large topiary plants. |
| 122060 | Basic establishment operations for standard trees, medium palms, small conifers or small topiary plants. |
| 122061 | Basic establishment operations for light standard trees or small palms. |
| 122062 | Basic establishment operations for whip trees or seedling trees. |
| 122063 | Basic establishment operations for bamboos, shrubs, ground covers or herbaceous plants, or climbers. |
| 122063a | Basic establishment operations for seasonal flowers. |
| 122063b | Horticultural maintenance operations for planted areas on ground level |
| 122063c | Horticultural maintenance operations for planted areas other than on ground level |
| 122064 | Weeding |
| 122065 | Grass cutting |
| 122066 | Mulching |
| 122067 | Applying fertilizers to grassed areas |
| 122068 | Apply insectcides, pesticides or fungicides to planted areas |
| 122069 | Apply insectcides, pesticides or fungicides to trees |
| 122070 | Apply fertilizers to planted areas |
| 122071 | Tree pruning with highest cutting point at height above ground not exceeding 7 m |
| 122072 | Tree pruning with highest cutting point at height above ground exceeding 7 m but not exceeding 18m |
| 122072a | Tree pruning with highest cutting point at height above ground exceeding 18m |
| 122072b | Extra over for pruning for limb reduction / removal for each limb of diameter at cutting position: Exceeding 100 - but not exceeding 200mm |
| 122072c | Extra over for pruning for limb reduction / removal for each limb of diameter at cutting position: Exceeding 200 |
| 122073 | Pruning for planted area |
| 122073a | Forking over |
| 122073b | Guying |
| 122073c | Stake and tie with three steel stakes |
| 122073d | Stake and tie with two steel stakes |
| 122073e | Stake and tie with three bamboo stakes |
| 122073f | Stake and tie with one bamboo stakes |
| 122073g | Adjust tree guys and stake anchors |
| 122073h | Adjust tree stakes and ties |
| 122073i | Remove tree guys and stake anchors |
| 122073j | Remove tree stakes and ties |
| 122074 | Transplanting of existing trees within the Site, diameter at breast height:- Exceeding 550 mm but not exceeding 1000 mm |
| 122074a | Transplanting of existing trees within the Site, diameter at breast height:- Exceeding 350 mm but not exceeding 550 mm |
| 122075 | Transplanting of existing trees within the Site, diameter at breast height:- Exceeding 200 mm but not exceeding 350 mm |
| 122076 | Transplanting of existing trees within the Site, diameter at breast height:- Exceeding 100 mm but not exceeding 200 mm |
| 122077 | Transplanting of existing trees within the Site, diameter at breast height:- Not exceeding 100 mm |
| 122078 | Transplanting of existing trees off Site, diameter at breast height:- Exceeding 350 mm but not exceeding 550 mm |
| 122079 | Transplanting of existing trees off Site, diameter at breast height:- Exceeding 200 mm but not exceeding 350 mm |
| 122080 | Transplanting of existing trees off Site, diameter at breast height:- Exceeding 100 mm but not exceeding 200 mm |
| 122081 | Transplanting of existing trees off Site, diameter at breast height:- Not exceeding 100 mm |
| 122082 | Preservation and protection measures to preserved trees, number of existing trees to be preserved :- Not exceeding 20 |
| 122083 | Preservation and protection measures to preserved trees, number of existing trees to be preserved :- Exceeding 20 but not exceeding 50 |
| 122084 | Preservation and protection measures to preserved trees, number of existing trees to be preserved :- Exceeding 50 but not exceeding 100 |
| 122085 | Preservation and protection measures to preserved trees, number of existing trees to be preserved :- Exceeding 100 but not exceeding 150 |
| 122086 | Preservation and protection measures to preserved trees, number of existing trees to be preserved :- Exceeding 150 but not exceeding 200 |
| 122087 | Preservation and protection measures to preserved trees, number of existing trees to be preserved :- Exceeding 200 but not exceeding 250 |
| 122088 | Preservation and protection measures to preserved trees, number of existing trees to be preserved :- Exceeding 250 |
| 122089 | Provide temporary protective mulching to protection zone of preserved trees, mulch thickness : - Exceeding 150 mm but not exceeding 300 mm |
| 122090 | Provide temporary protective mulching to protection zone of preserved trees, mulch thickness : - Exceeding 300 mm but not exceeding 500 mm |
| 122091 | Monthly maintenance for temporary protective mulching to protection zone of preserved trees, with mulch thickness: Exceeding 150mm but not exceeding 300mm |
| 122091a | Monthly maintenance for temporary protective mulching to protection zone of preserved trees, with mulch thickness: Exceeding 300 mm but not exceeding 500 mm |
| 122091b | Monthly maintenance for temporary protective mulching to protection zone of preserved trees, with mulch thickness: Supply temporary steel sheet covering to protection zone of preserved trees, 25 mm of minimum thickness |
| 122091c | Monthly maintenance for temporary protective mulching to protection zone of preserved trees, with mulch thickness: Monthly maintain temporary steel sheet covering to protection zone of preserved trees, steel sheet thickness 25 mm minimum |
| 122092 | Tree survey and identification labelling or marking systems of existing trees, number of trees :- Not exceeding 20 |
| 122093 | Tree survey and identification labelling or marking systems of existing trees, number of trees :- Exceeding 20 but not exceeding 50 |
| 122094 | Tree survey and identification labelling or marking systems of existing trees, number of trees :- Exceeding 50 but not exceeding 100 |
| 122095 | Tree survey and identification labelling or marking systems of existing trees, number of trees :- Exceeding 100 but not exceeding 150 |
| 122096 | Tree survey and identification labelling or marking systems of existing trees, number of trees :- Exceeding 150 but not exceeding 200 |
| 122097 | Tree survey and identification labelling or marking systems of existing trees, number of trees :- Exceeding 200 but not exceeding 250 |
| 122098 | Tree survey and identification labelling or marking systems of existing trees, number of trees :-Exceeding 250 |
| 122099 | Reports on updating of photographic record of preserved trees, number of trees :- Not exceeding 20 |
| 122100 | Reports on updating of photographic record of preserved trees, number of trees :- Exceeding 20 but not exceeding 50 |
| 122101 | Reports on updating of photographic record of preserved trees, number of trees :- Exceeding 50 but not exceeding 100 |
| 122102 | Reports on updating of photographic record of preserved trees, number of trees :- Exceeding 100 but not exceeding 150 |
| 122103 | Reports on updating of photographic record of preserved trees, number of trees :- Exceeding 150 but not exceeding 200 |
| 122104 | Reports on updating of photographic record of preserved trees, number of trees :- Exceeding 200 but not exceeding 250 |
| 122105 | Reports on updating of photographic record of preserved trees, number of trees :- Exceeding 250 |
| 122106 | Preservation and protection measures for Old and Valuable Trees |
| 122107 | Aftercare to Old and Valuable Trees |
| 122108 | Landscape design |
| 122109 | Independent tree specialists for Old and Valuable Trees. |
| 122110 | Individual tree risk assessments (tree base) |
| 122111 | Tomograph analysis |
| 122112 | Resistograph analysis |
| 122113 | Tree failure incident inspection |
| 122114 | Emergency tree failure incident inspection |
| 122115 | GIS information for individual tree |
| 122116a | Tree group inspections, number of trees to be inspected:- Not exceeding 20 |
| 122116b | Tree group inspections, number of trees to be inspected:- Exceeding 20 but not exceeding 50 |
| 122116c | Tree group inspections, number of trees to be inspected:- Exceeding 50 but not exceeding 100 |
| 122116d | Tree group inspections, number of trees to be inspected:- Exceeding 100 but not exceeding 150 |
| 122116e | Tree group inspections, number of trees to be inspected:- Exceeding 150 |
| 122117a | Set up segregation between BRR infected work area and external public area using woven polyethylene sheets protective screens or other approved material |
| 122117b | Provide protective clothing and accessories |
| 122117c | Disinfect infected area, equipment and debris of tree, Diameter at Breast Height (DBH) under 250mm |
| 122117d | Disinfect infected area, equipment and debris of tree, Diameter at Breast Height (DBH) 250mm-500mm |
| 122117e | Disinfect infected area, equipment and debris of tree, Diameter at Breast Height (DBH) 501mm-1000mm |
| 122117f | Disinfect infected area, equipment and debris of tree, Diameter at Breast Height (DBH) 1001mm-2000mm |
| 122117g | Disinfect infected area, equipment and debris of tree, Diameter at Breast Height (DBH) exceeds 2000mm |
| 122118 | Sonic Tomography and Relative Mechanical Strength Loss Analysis on trees |
| 123001 | Concrete maintenance staircase 600 mm wide with single handrailing as shown in Drawing Nos. C2101 and C2103 |
| 123002 | Ditto , with 1000 mm wide, double handrailing |
| 123003 | Steel maintenance staircase as shown in Drawing Nos. C2102/1 & 2 |
| 123004 | Steel maintenance ladder as shown in Drawing No. DS1044 |
| 123005 | Toe wall planter as shown in Drawing No. C2001, height of wall above ground level :- not exceeding 600 mm |
| 123006 | Toe wall planter as shown in Drawing No. C2001, height of wall above ground level :- Exceeding 600 mm but not exceeding 900 mm |
| 123007 | Toe wall planter as shown in Drawing No. C2001, height of wall above ground level :- Exceeding 900 mm but not exceeding 1200 mm |
| 123008 | Toe wall planter with stone facing and coping as shown in Drawing Nos. H5110 and H5111, height of wall above ground level :- not exceeding 800mm |
| 123009 | Toe wall planter with stone facing and coping as shown in Drawing Nos. H5110 and H5111, height of wall above ground level :- Exceeding 800mm but not exceeding 1200mm |
| 123010 | Vertical dwarf wall with stone facing block as shown in Drawing No. H5103, height of block not exceeding 600 mm |
| 123011 | Sloping dwarf wall with stone facing block as shown in Drawing No. H5103 |
| 123012 | Vertical dwarf wall with fractured concrete rib facing as shown in Drawing No. H5104, height of wall not exceeding 600 mm |
| 123013 | Ditto, with height exceeding 600 mm but not exceeding 1000 mm |
| 123014 | Sloping dwarf wall with fractured concrete rib facing as shown in Drawing No. H5104, height of wall not exceeding 600 mm |
| 123015 | Ditto, wiith height exceeding 600 mm but not exceeding 1000 mm |
| 123016 | Granite stone planter wall as shown in Drawing No. C2007, height not exceeding 600 mm |
| 123017 | Special vegetation clearance |
| 123018 | Provision of temporary steel ladders for slope access as shown in Drawing No. C2504 |
| 123019 | Removal of temporary steel ladders for slope access |
| 123020 | Planter Hole in Sprayed Concrete, 150 mm diameter pipe planter holes with top soil mix in sprayed concrete as shown in Drawing No. C2507 |
| 123021 | Planter Hole in Sprayed Concrete, 300 mm diameter pipe planter holes with top soil mix in sprayed concrete as shown in Drawing No. C2507 |
| 123022 | Supply, fix, maintain and remove steel decking including flooring, ladder, cover, fencing, support etc. made up of mild steel plates, channel, angles, sheetpile, universal beams and rods, etc. |
| 123023 | Clear weephole up to 80mm diameter on slopes or walls to a height of 3.5m above ground level or top of catchwater. |
| 123024 | Clear weephole up to 80mm diameter on slopes or walls to a height over 3.5m above ground level or top of catchwater. |
| 123025 | As Item No. 123/023 but to a vertical distance of 3.5m below ground level or top of catchwater. |
| 123026 | As Item No. 123/024 but to a vertical distance over 3.5m below ground level or top of catchwater. |
| 123027 | Clear and flush raking drains. |
| 123028 | Tarpaulin cover to slope or wall to a height of 3.5m measured vertically above ground level or top of catchwater. |
| 123029 | Tarpaulin cover to slope or wall to a height over 3.5m measured vertically above ground level or top of catchwater. |
| 123030 | Empty oil drums filled with aggregates acting as barrier |
| 123031 | Supply and fix type A temporary safety fence as shown in Drawing Nos. C2501/1 & C2501/2, including remove and clear away after works |
| 123032 | Supply and fix type B temporary safety fence as shown in Drawing Nos. C2502/1 & C2502/2, including remove and clear away after works |
| 123033 | Supply and fix type C temporary safety fence as shown in Sketch No. R1062, including remove and clear away after works |
| 123034 | Y20 dowel bar not exceeding 1000mm long with a 300mm bend |
| 123035 | Y20 dowel bar exceeding 1000mm long but not exceeding 2000mm long with a 300mm bend |
| 124001 | Root barriers |
| 124002 | Natural stepping stones, 600mmx300mmx30mm thick |
| 124003 | Permanent plant labels |
| 124004 | Temporary plant labels |
| 124005a | Round washed river pebbles in variety of colours, size:- exceeding 45 mm but not exceeding 60 mm |
| 124005b | Round washed river pebbles in variety of colours, size:- exceeding 60 mm but not exceeding 100 mm |
| 130001 | Transportation of load cell, from storage compound to site |
| 130002 | Transportation of load cell, from site to storage compound |
| 130003 | Transportation of load cell, from storage compound to an approved laboratory |
| 130004 | Transportation of load cell, from an approved laboratory to site |
| 130005 | Transportation of load cell, from an approved laboratory to storage compound |
| 130006 | Transportation of load cell, from site to an approved laboratory |
| 130007 | Calibrate load cell |
| 130008 | Supply and fix load cell adaptors |
| 130009 | Monitoring of ground anchors, ancillary equipment supplied by the Employer |
| 130010 | Monitoring of ground anchors, ancillary equipment supplied by the Contractor |
| 130011 | Remove for re-use and fix Cylindrical protective cap for ground anchor |
| 130012 | Remove for re-use and fix Rubber seal for the cylindrical protective cap for ground anchor |
| 130013 | Supply and fix: Cylindrical protective cap for ground anchor |
| 130014 | Supply and fix: Rubber seal for the cylindrical protective cap for ground anchor |
| 130015 | Clean and treat the base plate and bearing plate for ground anchor with anti-corrosion compound |
| 130016 | Carry out suitability test |
| 130017 | Replace grease Visconorust 2889 or prodcts having equivalent functions and performance as approved by the Engineer in the anchor head. |
| 140001A | Remove All debris and silt from catchwaters, irrigation channels, drainage channels or pits and similar where silt is less than or equal to 100 mm deep. Depth of catchwater, catchpit, irrigation channel or pit, clarifier, tank, service reservoir, valve chamber, intake culvert, tunnel and the like as appropriate Not exceeding 1.5 m |
| 140001B | Remove All debris and silt from catchwaters, irrigation channels, drainage channels or pits and similar where silt is less than or equal to 100 mm deep. Depth of catchwater, catchpit, irrigation channel or pit, clarifier, tank, service reservoir, valve chamber, intake culvert, tunnel and the like as appropriate Exceeding 1.5 m but not exceeding 3.0 m |
| 140001C | Remove All debris and silt from catchwaters, irrigation channels, drainage channels or pits and similar where silt is less than or equal to 100 mm deep. Depth of catchwater, catchpit, irrigation channel or pit, clarifier, tank, service reservoir, valve chamber, intake culvert, tunnel and the like as appropriate Exceeding 3.0 m |
| 140002A | Remove All debris and silt from catchwaters, irrigation channels, drainage channels or pits and similar where silt is more than 100mm but less than or equal to 150mm deep. Depth of catchwater, catchpit, irrigation channel or pit, clarifier, tank, service reservoir, valve chamber, intake culvert, tunnel and the like as appropriate Not exceeding 1.5 m |
| 140002B | Remove All debris and silt from catchwaters, irrigation channels, drainage channels or pits and similar where silt is more than 100mm but less than or equal to 150mm deep. Depth of catchwater, catchpit, irrigation channel or pit, clarifier, tank, service reservoir, valve chamber, intake culvert, tunnel and the like as appropriate Exceeding 1.5 m but not exceeding 3.0 m |
| 140002C | Remove All debris and silt from catchwaters, irrigation channels, drainage channels or pits and similar where silt is more than 100mm but less than or equal to 150mm deep. Depth of catchwater, catchpit, irrigation channel or pit, clarifier, tank, service reservoir, valve chamber, intake culvert, tunnel and the like as appropriate Exceeding 3.0 m |
| 140003A | Remove All debris and silt from catchwaters, irrigation channels, drainage channels or pits and similar where silt is more than 150 mm deep. Depth of catchwater, catchpit, irrigation channel or pit, clarifier, tank, service reservoir, valve chamber, intake culvert, tunnel and the like as appropriate Not exceeding 1.5 m |
| 140003B | Remove All debris and silt from catchwaters, irrigation channels, drainage channels or pits and similar where silt is more than 150 mm deep. Depth of catchwater, catchpit, irrigation channel or pit, clarifier, tank, service reservoir, valve chamber, intake culvert, tunnel and the like as appropriate Exceeding 1.5 m but not exceeding 3.0 m |
| 140003C | Remove All debris and silt from catchwaters, irrigation channels, drainage channels or pits and similar where silt is more than 150 mm deep. Depth of catchwater, catchpit, irrigation channel or pit, clarifier, tank, service reservoir, valve chamber, intake culvert, tunnel and the like as appropriate Exceeding 3.0 m |
| 140004A | Remove Silt and debris from dry weather flow channels. Depth of catchwater, catchpit, irrigation channel or pit, clarifier, tank, service reservoir, valve chamber, intake culvert, tunnel and the like as appropriate Not exceeding 1.5 m |
| 140004B | Remove Silt and debris from dry weather flow channels. Depth of catchwater, catchpit, irrigation channel or pit, clarifier, tank, service reservoir, valve chamber, intake culvert, tunnel and the like as appropriate Exceeding 1.5 m but not exceeding 3.0 m |
| 140004C | Remove Silt and debris from dry weather flow channels. Depth of catchwater, catchpit, irrigation channel or pit, clarifier, tank, service reservoir, valve chamber, intake culvert, tunnel and the like as appropriate Exceeding 3.0 m |
| 140005A | Remove Silt and debris from catchpits. Depth of catchwater, catchpit, irrigation channel or pit, clarifier, tank, service reservoir, valve chamber, intake culvert, tunnel and the like as appropriate Not exceeding 1.5 m |
| 140005B | Remove Silt and debris from catchpits. Depth of catchwater, catchpit, irrigation channel or pit, clarifier, tank, service reservoir, valve chamber, intake culvert, tunnel and the like as appropriate Exceeding 1.5 m but not exceeding 3.0 m |
| 140005C | Remove Silt and debris from catchpits. Depth of catchwater, catchpit, irrigation channel or pit, clarifier, tank, service reservoir, valve chamber, intake culvert, tunnel and the like as appropriate Exceeding 3.0 m |
| 140006A | Remove Boulders between 0.03 m3 and 0.1 m3 from catchwaters and irrigation channels or pits. Depth of catchwater, catchpit, irrigation channel or pit, clarifier, tank, service reservoir, valve chamber, intake culvert, tunnel and the like as appropriate Not exceeding 1.5 m |
| 140006B | Remove Boulders between 0.03 m3 and 0.1 m3 from catchwaters and irrigation channels or pits. Depth of catchwater, catchpit, irrigation channel or pit, clarifier, tank, service reservoir, valve chamber, intake culvert, tunnel and the like as appropriate Exceeding 1.5 m but not exceeding 3.0 m |
| 140006C | Remove Boulders between 0.03 m3 and 0.1 m3 from catchwaters and irrigation channels or pits. Depth of catchwater, catchpit, irrigation channel or pit, clarifier, tank, service reservoir, valve chamber, intake culvert, tunnel and the like as appropriate Exceeding 3.0 m |
| 140007A | Remove Boulders over 0.1 m3, from catchwaters and irrigation channels or pits, blasting permitted. Depth of catchwater, catchpit, irrigation channel or pit, clarifier, tank, service reservoir, valve chamber, intake culvert, tunnel and the like as appropriate Not exceeding 1.5 m |
| 140007B | Remove Boulders over 0.1 m3, from catchwaters and irrigation channels or pits, blasting permitted. Depth of catchwater, catchpit, irrigation channel or pit, clarifier, tank, service reservoir, valve chamber, intake culvert, tunnel and the like as appropriate Exceeding 1.5 m but not exceeding 3.0 m |
| 140007C | Remove Boulders over 0.1 m3, from catchwaters and irrigation channels or pits, blasting permitted. Depth of catchwater, catchpit, irrigation channel or pit, clarifier, tank, service reservoir, valve chamber, intake culvert, tunnel and the like as appropriate Exceeding 3.0 m |
| 140008A | Remove boulders over 0.1 m3, from catchwaters and irrigation channels or pits, blasting not permitted. Depth of catchwater, catchpit, irrigation channel or pit, clarifier, tank, service reservoir, valve chamber, intake culvert, tunnel and the like as appropriate Not exceeding 1.5 m |
| 140008B | Remove boulders over 0.1 m3, from catchwaters and irrigation channels or pits, blasting not permitted. Depth of catchwater, catchpit, irrigation channel or pit, clarifier, tank, service reservoir, valve chamber, intake culvert, tunnel and the like as appropriate Exceeding 1.5 m but not exceeding 3.0 m |
| 140008C | Remove boulders over 0.1 m3, from catchwaters and irrigation channels or pits, blasting not permitted. Depth of catchwater, catchpit, irrigation channel or pit, clarifier, tank, service reservoir, valve chamber, intake culvert, tunnel and the like as appropriate Exceeding 3.0 m |
| 140009A | Remove silt, lime residue, alum residue, etc. from clarifiers, tanks, service reservoirs and the like, or silt and debris from sumps, wet wells and intake culverts in pumping stations. Depth of catchwater, catchpit, irrigation channel or pit, clarifier, tank, service reservoir, valve chamber, intake culvert, tunnel and the like as appropriate Not exceeding 1.5 m |
| 140009B | Remove silt, lime residue, alum residue, etc. from clarifiers, tanks, service reservoirs and the like, or silt and debris from sumps, wet wells and intake culverts in pumping stations. Depth of catchwater, catchpit, irrigation channel or pit, clarifier, tank, service reservoir, valve chamber, intake culvert, tunnel and the like as appropriate Exceeding 1.5 m but not exceeding 3.0 m |
| 140009C | Remove silt, lime residue, alum residue, etc. from clarifiers, tanks, service reservoirs and the like, or silt and debris from sumps, wet wells and intake culverts in pumping stations. Depth of catchwater, catchpit, irrigation channel or pit, clarifier, tank, service reservoir, valve chamber, intake culvert, tunnel and the like as appropriate Exceeding 3.0 m |
| 140010A | Extra over Item No. 140/009 when divers are required, including all crafts, attendants and the necessary equipment and insurance. Depth of catchwater, catchpit, irrigation channel or pit, clarifier, tank, service reservoir, valve chamber, intake culvert, tunnel and the like as appropriate Not exceeding 1.5 m |
| 140010B | Extra over Item No. 140/009 when divers are required, including all crafts, attendants and the necessary equipment and insurance. Depth of catchwater, catchpit, irrigation channel or pit, clarifier, tank, service reservoir, valve chamber, intake culvert, tunnel and the like as appropriate Exceeding 1.5 m but not exceeding 3.0 m |
| 140010C | Extra over Item No. 140/009 when divers are required, including all crafts, attendants and the necessary equipment and insurance. Depth of catchwater, catchpit, irrigation channel or pit, clarifier, tank, service reservoir, valve chamber, intake culvert, tunnel and the like as appropriate Exceeding 3.0 m |
| 140011A | Remove silt and debris from valve chambers. Depth of catchwater, catchpit, irrigation channel or pit, clarifier, tank, service reservoir, valve chamber, intake culvert, tunnel and the like as appropriate Not exceeding 1.5 m |
| 140011B | Remove silt and debris from valve chambers. Depth of catchwater, catchpit, irrigation channel or pit, clarifier, tank, service reservoir, valve chamber, intake culvert, tunnel and the like as appropriate Exceeding 1.5 m but not exceeding 3.0 m |
| 140011C | Remove silt and debris from valve chambers. Depth of catchwater, catchpit, irrigation channel or pit, clarifier, tank, service reservoir, valve chamber, intake culvert, tunnel and the like as appropriate Exceeding 3.0 m |
| 140012A | Remove contaminated aggregates from lime and alum tanks in separate layers for different sizes, wash the aggregate and replace in separate layers. Depth of catchwater, catchpit, irrigation channel or pit, clarifier, tank, service reservoir, valve chamber, intake culvert, tunnel and the like as appropriate Not exceeding 1.5 m |
| 140012B | Remove contaminated aggregates from lime and alum tanks in separate layers for different sizes, wash the aggregate and replace in separate layers. Depth of catchwater, catchpit, irrigation channel or pit, clarifier, tank, service reservoir, valve chamber, intake culvert, tunnel and the like as appropriate Exceeding 1.5 m but not exceeding 3.0 m |
| 140012C | Remove contaminated aggregates from lime and alum tanks in separate layers for different sizes, wash the aggregate and replace in separate layers. Depth of catchwater, catchpit, irrigation channel or pit, clarifier, tank, service reservoir, valve chamber, intake culvert, tunnel and the like as appropriate Exceeding 3.0 m |
| 140013 | Extra over Item No. 140/012 for provision of new aggregates and disposal of old. |
| 140014 | Remove all debris and silt from intakes and the like. |
| 140015 | Remove boulders between 0.03 m3 and 0.1 m3 from intakes. |
| 140016 | Remove boulders over 0.1 m3 from intakes, blasting permitted. |
| 140017 | Remove boulders over 0.1 m3 from intakes, blasting not permitted. |
| 140017a | Extra over Item No. 140/014 to 017 when divers are required, including all crafts, attendants and the necessary equipment and insurance. |
| 140018 | Remove all debris from surface channels such as U channels and flat channels. |
| 140019 | Clear up debris and silt inside tunnel which is physically accessible by mechanical transport, with haulage distance not exceeding 1.6 km inside tunnel. |
| 140020 | Extra over Item No. 140/019 for each additional 0.4 km of transportation or part thereof inside tunnel. (Transportation outside tunnel will be paid under Group F). |
| 140021 | Clear up debris and silt inside tunnel which is NOT physically accessible by mechanical transport, with haulage distance not exceeding 180 m inside tunnel. |
| 140022 | Extra over Item No. 140/021 for each additional 180 m of transportation or part thereof inside tunnel. (Transportation outside tunnel will be paid under Group F). |
| 140023 | Extra over Item No. 140/021 for hoisting onto surface through shafts and dispose of as directed within 45 m of outlet of shaft. |
| 140024 | Desilt half round or U-channels. |
| 140025 | Desilt stepped channels. |
| 150001 | Standard 225 mm irrigation channel (in Grade 20/20S concrete) as shown in Fig. No. 1 of Drawing No. SK 2953/4 and as specified. |
| 150002 | 300 mm irrigation channel (in Grade 20/20S concrete) as shown in Fig. No. 2 of Drawing No. SK 2953/4 and as specified. |
| 150003 | 450 mm irrigation channel (in Grade 20/20S concrete) as shown in Fig. No. 3 of Drawing No. SK 2953/4 and as specified. |
| 150004 | 600 mm irrigation channel (in Grade 20/20S concrete) as shown in Fig. No. 4 of Drawing No. SK 2953/4 and as specified. |
| 150005 | Standard 255 mm irrigation step channel (in Grade 20/20S concrete) as shown in Drawing No. SK 2953/4 and as specified. |
| 150006 | Standard 300 mm irrigation step channel (in Grade 20/20S concrete) as shown in Drawing No. SK 2953/4 and as specified. |
| 150007 | Standard 450 mm irrigation step channel (in Grade 20/20S concrete) as shown in Drawing No. SK 2953/4 and as specified. |
| 150008 | Standard 600 mm irrigation step channel (in Grade 20/20S concrete) as shown in Drawing No. SK 2953/4 and as specified. |
| 150009 | Earth and timber temporary cofferdam. |
| 150010 | Watertight timber flume. |
| 150011 | Hand packed rubble in stream beds to form protective apron or foundation. |
| 150012 | Hardcore to foundation of irrigation channel. |
| 150013 | Embossed number plaque 200 mm x 100 mm on irrigation dams. |
| 150014 | As Item No. 150/013, but for irrigation dams previously constructed. |
| 150015 | Cement mortar plaque 450 mm x 225 mm on irrigation dams. |
| 150016 | As Item No. 150/015, but for irrigation dams previously constructed. |
| 160001A | Dry random rubble wall, uncoursed. Stones provided by the Employer |
| 160001B | Dry random rubble wall, uncoursed. Stones provided by the Contractor |
| 160002A | Random rubble wall in cement mortar, uncoursed. Stones provided by the Employer |
| 160002B | Random rubble wall in cement mortar, uncoursed. Stones provided by the Contractor |
| 160003A | Dry squared rubble wall, coursed. Stones provided by the Employer |
| 160003B | Dry squared rubble wall, coursed. Stones provided by the Contractor |
| 160004A | Squared rubble wall in cement mortar, coursed. Stones provided by the Employer |
| 160004B | Squared rubble wall in cement mortar, coursed. Stones provided by the Contractor |
| 160005A | Ashlar masonry, straight or curved with radius over 15 m. Stones provided by the Employer |
| 160005B | Ashlar masonry, straight or curved with radius over 15 m. Stones provided by the Contractor |
| 160006A | Ashlar masonry, straight or curved with radius over 15 m, battered face. Stones provided by the Employer |
| 160006B | Ashlar masonry, straight or curved with radius over 15 m, battered face. Stones provided by the Contractor |
| 160007A | Ashlar masonry, curved face less than 15 m radius. Stones provided by the Employer |
| 160007B | Ashlar masonry, curved face less than 15 m radius. Stones provided by the Contractor |
| 160008A | Masonry in special shapes, fine punched exposed faces laid close and jointed in cement mortar. Stones provided by the Employer |
| 160008B | Masonry in special shapes, fine punched exposed faces laid close and jointed in cement mortar. Stones provided by the Contractor |
| 160009A | Hand packed rubble, behind walls. Stones provided by the Employer |
| 160009B | Hand packed rubble, behind walls. Stones provided by the Contractor |
| 160010A | 40 mm broken stone laid around drains etc. Stones provided by the Employer |
| 160010B | 40 mm broken stone laid around drains etc. Stones provided by the Contractor |
| 160011A | 225 mm thick granite sets in cement mortar as walls to non-circular wells. Stones provided by the Employer |
| 160011B | 225 mm thick granite sets in cement mortar as walls to non-circular wells. Stones provided by the Contractor |
| 160012A | 225 mm thick granite sets in cement mortar as walls to circular wells. Stones provided by the Employer |
| 160012B | 225 mm thick granite sets in cement mortar as walls to circular wells. Stones provided by the Contractor |
| 160013A | Rip rap. Stones provided by the Employer |
| 160013B | Rip rap. Stones provided by the Contractor |
| 160014A | Rip rap in cement mortar. Stones provided by the Employer |
| 160014B | Rip rap in cement mortar. Stones provided by the Contractor |
| 160015A | Dry rubble pitching of 225 mm nominal thickness to slopes. Stones provided by the Employer |
| 160015B | Dry rubble pitching of 225 mm nominal thickness to slopes. Stones provided by the Contractor |
| 160016A | Dry rubble pitching of 300 mm nominal thickness to slopes. Stones provided by the Employer |
| 160016B | Dry rubble pitching of 300 mm nominal thickness to slopes. Stones provided by the Contractor |
| 160017A | Rubble pitching of 225 mm nominal thickness in cement mortar. Stones provided by the Employer |
| 160017B | Rubble pitching of 225 mm nominal thickness in cement mortar. Stones provided by the Contractor |
| 160018A | Rubble pitching of 300 mm nominal thickness in cement mortar. Stones provided by the Employer |
| 160018B | Rubble pitching of 300 mm nominal thickness in cement mortar. Stones provided by the Contractor |
| 160019A | 80 mm thick granite stone facing, random pattern as shown in Drawing no. C2002/2. Stones provided by the Employer |
| 160019B | 80 mm thick granite stone facing, random pattern as shown in Drawing no. C2002/2. Stones provided by the Contractor |
| 160020A | 300 mm x 150 mm x 50 mm thick granite stone facing, rectangular pattern as shown in Drawing no. C2002/2. Stones provided by the Employer |
| 160020B | 300 mm x 150 mm x 50 mm thick granite stone facing, rectangular pattern as shown in Drawing no. C2002/2. Stones provided by the Contractor |
| 160021A | 200 mm x 200 mm x 50 mm thick granite block stone facing, square pattern as shown in Drawing no. C2002/1. Stones provided by the Employer |
| 160021B | 200 mm x 200 mm x 50 mm thick granite block stone facing, square pattern as shown in Drawing no. C2002/1. Stones provided by the Contractor |
| 160022 | Take down dry rubble wall, rubble pitching or rip rap. |
| 160023 | As Item No. 160/022 but in lime mortar. |
| 160024 | As Item No. 160/022 but in 1:3 cement mortar. |
| 160025 | Take down ashlar masonry. |
| 161001 | Remove brickwork or blockwork in lime mortar. |
| 161002 | Remove brickwork or blockwork in cement mortar. |
| 161003 | 225 mm x 112.5 mm x 75 mm clay bricks in cement mortar in stretcher bond, in wall 112.5 mm thick. |
| 161004 | 225 mm x 112.5 mm x 75 mm clay bricks in cement lime mortar in English bond, in wall 225 mm thick. |
| 161005 | 225 mm x 112.5 mm x 75 mm clay bricks in cement lime mortar in English bond, in wall 337.5 mm thick. |
| 161006 | Extra over Item Nos. 161/003 to 161/005 for arched brickwork. |
| 161007 | 2-layer 2-ply damp proof course. |
| 161008 | Remove for re-use glass block walling. |
| 161009 | Extra over Item No. 161/008 for clean and stack for re-use. |
| 161010 | Fix 80 mm thick glass block walling, glass blocks provided by the Contractor. |
| 161011 | Fix 80 mm thick glass block walling, glass blocks provided by the Employer. |
| 161012 | Cut holes in brickwork or blockwork for holes exceeding 16500 mm3. |
| 161013 | Cut holes in brickwork or blockwork for holes not exceeding 16500 mm3. |
| 162001A | Supply, fix, maintain and remove rough timber boarding. Thickness (mm) 12 |
| 162001B | Supply, fix, maintain and remove rough timber boarding. Thickness (mm) 19 |
| 162001C | Supply, fix, maintain and remove rough timber boarding. Thickness (mm) 25 |
| 162001D | Supply, fix, maintain and remove rough timber boarding. Thickness (mm) 38 |
| 162001E | Supply, fix, maintain and remove rough timber boarding. Thickness (mm) 44 |
| 162001F | Supply, fix, maintain and remove rough timber boarding. Thickness (mm) 50 |
| 162002A | Supply and fix rough timber boarding. Thickness (mm) 12 |
| 162002B | Supply and fix rough timber boarding. Thickness (mm) 19 |
| 162002C | Supply and fix rough timber boarding. Thickness (mm) 25 |
| 162002D | Supply and fix rough timber boarding. Thickness (mm) 38 |
| 162002E | Supply and fix rough timber boarding. Thickness (mm) 44 |
| 162002F | Supply and fix rough timber boarding. Thickness (mm) 50 |
| 162003 | Supply, fix, maintain and remove rough timber scantlings and supports. |
| 162004 | Supply and fix rough timber scantlings and supports not exceeding 0.065 m2 in cross section. |
| 162005 | Supply and fix timber boarding 25 mm thick wrought on both sides and edges, and tongued and grooved if (or as) directed. |
| 162006 | Supply and fix timber scantlings and supports not exceeding 0.065 m2 in cross section, wrought on all faces. |
| 162007 | Supply and fix rough timber weather boarding 19 mm thick in 150 mm width including rebating on thick edge and secured to framing with 50 mm cut nails. |
| 162008A | Supply and fix framed, ledged and braced timber doors filled with tongued and grooved wrought boarding beaded or chamfered both sides. Finished thickness (mm) 44 |
| 162008B | Supply and fix framed, ledged and braced timber doors filled with tongued and grooved wrought boarding beaded or chamfered both sides. Finished thickness (mm) 50 |
| 162008C | Supply and fix framed, ledged and braced timber doors filled with tongued and grooved wrought boarding beaded or chamfered both sides. Finished thickness (mm) 57 |
| 162009A | Supply and fix wrought, framed, square and flat both sides, timber panelled doors. Finished thickness (mm) 44 |
| 162009B | Supply and fix wrought, framed, square and flat both sides, timber panelled doors. Finished thickness (mm) 50 |
| 162009C | Supply and fix wrought, framed, square and flat both sides, timber panelled doors. Finished thickness (mm) 57 |
| 162010A | As for Item No. 162/009 but of teak wood. Finished thickness (mm) 44 |
| 162010B | As for Item No. 162/009 but of teak wood. Finished thickness (mm) 50 |
| 162010C | As for Item No. 162/009 but of teak wood. Finished thickness (mm) 57 |
| 162011A | Supply and fix wrought, framed timber flush doors covered with luan faced 3 mm plywood on both faces. Timber fillet mitred around edges. Finished thickness (mm) 44 |
| 162011B | Supply and fix wrought, framed timber flush doors covered with luan faced 3 mm plywood on both faces. Timber fillet mitred around edges. Finished thickness (mm) 50 |
| 162011C | Supply and fix wrought, framed timber flush doors covered with luan faced 3 mm plywood on both faces. Timber fillet mitred around edges. Finished thickness (mm) 57 |
| 162012A | Supply and fix solid core timber flush doors with teak wood edging and covered with luan faced 3 mm plywood on both sides. Finished thickness (mm) 44 |
| 162012B | Supply and fix solid core timber flush doors with teak wood edging and covered with luan faced 3 mm plywood on both sides. Finished thickness (mm) 50 |
| 162012C | Supply and fix solid core timber flush doors with teak wood edging and covered with luan faced 3 mm plywood on both sides. Finished thickness (mm) 57 |
| 162013A | Supply and fix wrought timber window sashes. Finished thickness (mm) 44 |
| 162013B | Supply and fix wrought timber window sashes. Finished thickness (mm) 50 |
| 162013C | Supply and fix wrought timber window sashes. Finished thickness (mm) 57 |
| 162014 | Extra over Item Nos. 162/008 to 162/012 for formation and fixing of timber louvres to doors. |
| 162015 | Extra over Item Nos. 162/008 to 162/012 for door to be covered with teak faced 3 mm plywood on both sides. |
| 162017 | Supply and fix timber windows and door frames, wrought, framed, rebated on the solid as required, with rounded or chamfered edges, grooved for plaster, pinned at joints with teak pins, including cutting holes, in concrete or brickwork, provision of lugs, etc. and making good of surroundings. |
| 162018 | Remove existing timber doors. |
| 162019 | Remove existing timber windows. |
| 162020 | Remove existing door frames for door opening not exceeding 2.8 m2. |
| 162021 | Remove existing door frames for door opening exceeding 2.8 m2. |
| 162022 | Fix only timber doors supplied by the Employer. |
| 162024 | Supply and fix strong fencing of China fir or other approved poles, for 3 m height. |
| 162026 | Supply soft wood timber scantling in sizes as required. |
| 162027 | Supply hardwood timber scantling in sizes as required. |
| 162028 | Supply and fix plywood boarding, luan faced, 12 mm thick sound flat with glass papered finish. |
| 162029 | Add to or deduct from Item No. 162/028 for each 3 mm, variation in thickness. |
| 162030 | Supply and fix approved standard hardboard, 3 mm nominal thickness. |
| 162031 | Supply and fix fibre insulation board, 12 mm thick. |
| 162032 | Remove and clear away timber boarding not exceeding 25 mm thick. |
| 162033 | Remove and clear away timber boarding exceeding 25 mm thick. |
| 162034 | Remove and clear away timber scantlings of any size. |
| 162035 | Bamboo scaffolding (Single bank). |
| 162036 | Bamboo scaffolding inside service reservoir (Single bank). |
| 162037 | Bamboo scaffolding inside building (Single bank). |
| 162037A | Bamboo scaffolding underneath and running alongside bridge deck (Single bank). |
| 162038 | Bamboo scaffolding (Double bank). |
| 162039 | Bamboo scaffolding inside service reservoir (Double bank). |
| 162040 | Bamboo scaffolding inside building (Double bank). |
| 162040A | Bamboo scaffolding underneath and running alongside bridge deck (Double bank). |
| 170001 | Cement rendering, 10 mm thick. |
| 170002 | Extra over Item No. 170/001 for each additional 5 mm thick coat or part thereof in excess of 10 mm. |
| 170003 | Extra over Item No. 170/001 for isolated patches not exceeding 0.6 m2 each. |
| 170004 | Remove cement rendering or granolithic or terrazzo paving per 5 mm thick. |
| 170005 | Form cement mortar (1:3) fillets, not exceeding 3,870 mm2 in section, including approved bonding additive. |
| 170006 | Form cement mortar (1:3) fillets, exceeding 3,870 mm2 but not exceeding 5,000 mm2 in section, including approved bonding additive. |
| 170007 | Cement rendering with approved waterproofing agent one coat, 10 mm thick (composition of cement mortar : 1 part of cement to 2 parts of fine aggregates by volume). |
| 170007a | Cement rendering with Nafufill KM 250 or equivalent in compliance with BS6920, 10mm thick. |
| 170008 | Extra over Item No. 170/007 for each additional 5 mm thickness or part thereof in excess of 10 mm. |
| 170008a | Extra over Item No. 170/007a for each additional 5 mm thickness or part thereof in excess of 10 mm. |
| 170009 | Rendering with approved epoxy mortar 3 mm thick. |
| 170010 | Extra over Item No. 170/009 for each 3 mm thickness or part thereof in excess of 3 mm thick. |
| 170011 | Grout in with cement mortar bolts, pipe brackets, lifting eye, etc. (composition of cement mortar : 1 part of cement to 2 parts of fine aggregates by volume). |
| 170012 | Fix in position approved resin anchors up to 20 mm diameter. |
| 170013 | Apply waterproof caulking compound to chases of cross section up to 1,250 mm2. Material provided by the Employer. |
| 170014 | Extra over Item No. 170/013 for each 625 mm2 in cross section or part thereof in excess of cross section of 1,250 mm2. |
| 170015 | Granolithic concrete finish to floors, 20 mm thick. |
| 170016 | Granolithic concrete finish to kerbs, 20 mm thick. |
| 170017 | Extra over Item Nos. 170/015 and 170/016 for each additional 20 mm thick or part thereof in excess of 20 mm. |
| 170018 | Shanghai plaster, 20 mm thick. |
| 170019 | Terrazzo finish, 20 mm thick. |
| 170020 | Lime plaster of 15 mm thick to internal surfaces. |
| 170021 | Rendering to floor, 25 mm average thickness. |
| 170022 | Extra over Item No. 170/021 for each additional 12.5 mm in average thickness in excess of 25 mm. |
| 170023 | Sandtex trowel finish to external walls. |
| 170024 | Rub down concrete surfaces with carborundum stone. |
| 170025 | Clean and renovate existing terrazzo surfaces. |
| 170026 | Red Chinese paving tiles, 38 mm thick in single layer to flat roofs. |
| 170027 | Precast insulating concrete tiles over roof slab. |
| 170028 | Break up and remove red Chinese paving tiles and supports, or precast concrete roofing tiles. |
| 170029 | Remove for re-use and refix red Chinese paving tiles or precast concrete roofing tiles. |
| 170030 | Double Chinese roof tiling on pitched roofs complete including rools etc. |
| 170031 | Break up and remove double Chinese roof tiling on pitched roofs. |
| 170032 | Remove for re-use and refix double Chinese roof tiling on pitched roof. |
| 170033 | Break up and remove existing tiling and prepare surface for relaying. |
| 170034 | Mosaic tiles on walls and floor finishing. |
| 170035 | Glazed ceramic mosaic tiles on walls. |
| 170037 | Vinyl tiles. |
| 170038 | Acid resisting plain surface tiles, 150 mm x 150 mm x 12.5 mm, to alum tanks. |
| 170039 | 18 mm x 18 mm x 15 mm thick, glazed ceramic mosaic tiles in assorted colour to form water level indicators, name plates, etc. |
| 170040 | Vitrified clay tiles to floors. |
| 170041 | Unglazed non-slip clay tiles to floors. |
| 170042 | 25 mm thick heavy duty, low sound reflectance coefficient, oil resistant, non-slip ceramic floor tiles. |
| 170043 | Heavy duty, low sound reflectance coefficient, oil resistant, non-slip ceramic tiles, up to 10 mm thick, to walls and columns. |
| 170044 | Heavy duty, low sound reflectance coefficient, oil resistance, non-slip glazed ceramic tiles, up to 10 mm thick, to walls and columns. |
| 180001 | Removal and Disposal of Filter Media |
| 180002 | Supply and Placing of Pebbles |
| 180003 | Supply and Placing of Coarse Sand |
| 180004 | Supply and Placing of Fine Sand |
| 180005 | Supply and Placing of Anthracite |
| 180006 | Wash, Clean and Place Filter Media |
| 180007 | Place Filter Media supplied by the Engineer |
| 180008 | (Not used)Sieve filter media, sand, anthracite, pebbles and the like for use in filter beds. |
| 180009 | Take up, clean and relay perforated tiles to filters. |
| 180010 | Take up, clean and relay lateral drains to filters. |
| 180011 | Remove for re-use graded stone aggregates, 10 mm to 20 mm in size, from existing roof drains of service reservoirs. |
| 180012 | Deposit only graded stone aggregates, 10 mm to 20 mm in size, to roof drains of service reservoirs. Stone aggregates provided by the Employer. |
| 180013 | As Item No. 180/012, but stone aggregates supplied by the Contractor. |
| 180014 | Remove and wash for re-use perforated tiles and bricks etc. from service reservoir roofs, drains, filter beds etc. |
| 180015 | Lay only perforated tiles and bricks to drains. Tiles and bricks provided by the Employer. Width of each line of drain not exceeding 380 mm. |
| 180016 | Lay only perforated tiles and bricks to service reservoir roofs, drains, filter beds etc. Tiles and bricks provided by the Employer. Width of each line of drain exceeding 380 mm. |
| 180017 | As Item No. 180/015, but tiles and bricks supplied by the Contractor. |
| 180018 | As Item No. 180/016, but tiles and bricks supplied by the Contractor. |
| 180019 | Drill holes in P.V.C. pipes for use as replacement laterals. |
| 180019a | Removal and Disposal of Filter Media |
| 180019b | Supply and Placing of Pebbles |
| 180019c | Supply and Placing of Coarse Sand |
| 180019d | Supply and Placing of Fine Sand |
| 180019e | Supply and Placing of Anthracite |
| 180020 | Supply and fix glass-fibre reinforced plastic panels over the roof of service reservoirs and the like. |
| 181001A | (A) Class M precast concrete pipes or stoneware pipes S=0, T=1.5 Nominal diameter of pipe 80 mm & under |
| 181001ae | (C) Class H precast concrete pipes or stoneware pipes S=0, T=1.5 Nominal diameter of pipe 300 mm |
| 181001af | (C) Class H precast concrete pipes or stoneware pipes S=0, T=1.5 Nominal diameter of pipe 375 mm |
| 181001ag | (C) Class H precast concrete pipes or stoneware pipes S=0, T=1.5 Nominal diameter of pipe 450 mm |
| 181001ah | (C) Class H precast concrete pipes or stoneware pipes S=0, T=1.5 Nominal diameter of pipe 600 mm |
| 181001ai | (C) Class H precast concrete pipes or stoneware pipes S=0, T=1.5 Nominal diameter of pipe 750 mm |
| 181001aj | (C) Class H precast concrete pipes or stoneware pipes S=0, T=1.5 Nominal diameter of pipe 900mm |
| 181001ak | (C) Class H precast concrete pipes or stoneware pipes S=0, T=1.5 Nominal diameter of pipe 1050 mm |
| 181001B | (A) Class M precast concrete pipes or stoneware pipes S=0, T=1.5 Nominal diameter of pipe 100 mm |
| 181001C | (A) Class M precast concrete pipes or stoneware pipes S=0, T=1.5 Nominal diameter of pipe 150 mm |
| 181001D | (A) Class M precast concrete pipes or stoneware pipes S=0, T=1.5 Nominal diameter of pipe 225 mm |
| 181001E | (A) Class M precast concrete pipes or stoneware pipes S=0, T=1.5 Nominal diameter of pipe 300 mm |
| 181001F | (A) Class M precast concrete pipes or stoneware pipes S=0, T=1.5 Nominal diameter of pipe 375 mm |
| 181001G | (A) Class M precast concrete pipes or stoneware pipes S=0, T=1.5 Nominal diameter of pipe 450 mm |
| 181001H | (A) Class M precast concrete pipes or stoneware pipes S=0, T=1.5 Nominal diameter of pipe 600 mm |
| 181001I | (A) Class M precast concrete pipes or stoneware pipes S=0, T=1.5 Nominal diameter of pipe 750 mm |
| 181001J | (A) Class M precast concrete pipes or stoneware pipes S=0, T=1.5 Nominal diameter of pipe 900 mm |
| 181001K | (A) Class M precast concrete pipes or stoneware pipes S=0, T=1.5 Nominal diameter of pipe 1050 mm |
| 181002A | (A) Class M precast concrete pipes or stoneware pipes S=1.5, T=2.5 Nominal diameter of pipe 80 mm & under |
| 181002ae | (C) Class H precast concrete pipes or stoneware pipes S=1.5, T=2.5 Nominal diameter of pipe 300 mm |
| 181002af | (C) Class H precast concrete pipes or stoneware pipes S=1.5, T=2.5 Nominal diameter of pipe 375 mm |
| 181002ag | (C) Class H precast concrete pipes or stoneware pipes S=1.5, T=2.5 Nominal diameter of pipe 450 mm |
| 181002ah | (C) Class H precast concrete pipes or stoneware pipes S=1.5, T=2.5 Nominal diameter of pipe 600 mm |
| 181002ai | (C) Class H precast concrete pipes or stoneware pipes S=1.5, T=2.5 Nominal diameter of pipe 750 mm |
| 181002aj | (C) Class H precast concrete pipes or stoneware pipes S=1.5, T=2.5 Nominal diameter of pipe 900mm |
| 181002ak | (C) Class H precast concrete pipes or stoneware pipes S=1.5, T=2.5 Nominal diameter of pipe 1050 mm |
| 181002B | (A) Class M precast concrete pipes or stoneware pipes S=1.5, T=2.5 Nominal diameter of pipe 100 mm |
| 181002C | (A) Class M precast concrete pipes or stoneware pipes S=1.5, T=2.5 Nominal diameter of pipe 150 mm |
| 181002D | (A) Class M precast concrete pipes or stoneware pipes S=1.5, T=2.5 Nominal diameter of pipe 225 mm |
| 181002E | (A) Class M precast concrete pipes or stoneware pipes S=1.5, T=2.5 Nominal diameter of pipe 300 mm |
| 181002F | (A) Class M precast concrete pipes or stoneware pipes S=1.5, T=2.5 Nominal diameter of pipe 375 mm |
| 181002G | (A) Class M precast concrete pipes or stoneware pipes S=1.5, T=2.5 Nominal diameter of pipe 450 mm |
| 181002H | (A) Class M precast concrete pipes or stoneware pipes S=1.5, T=2.5 Nominal diameter of pipe 600 mm |
| 181002I | (A) Class M precast concrete pipes or stoneware pipes S=1.5, T=2.5 Nominal diameter of pipe 750 mm |
| 181002J | (A) Class M precast concrete pipes or stoneware pipes S=1.5, T=2.5 Nominal diameter of pipe 900 mm |
| 181002K | (A) Class M precast concrete pipes or stoneware pipes S=1.5, T=2.5 Nominal diameter of pipe 1050 mm |
| 181003A | (A) Class M precast concrete pipes or stoneware pipes S=2.5, T=3.5 Nominal diameter of pipe 80 mm & under |
| 181003ae | (C) Class H precast concrete pipes or stoneware pipes S=2.5, T=3.5 Nominal diameter of pipe 300 mm |
| 181003af | (C) Class H precast concrete pipes or stoneware pipes S=2.5, T=3.5 Nominal diameter of pipe 375 mm |
| 181003ag | (C) Class H precast concrete pipes or stoneware pipes S=2.5, T=3.5 Nominal diameter of pipe 450 mm |
| 181003ah | (C) Class H precast concrete pipes or stoneware pipes S=2.5, T=3.5 Nominal diameter of pipe 600 mm |
| 181003ai | (C) Class H precast concrete pipes or stoneware pipes S=2.5, T=3.5 Nominal diameter of pipe 750 mm |
| 181003aj | (C) Class H precast concrete pipes or stoneware pipes S=2.5, T=3.5 Nominal diameter of pipe 900mm |
| 181003ak | (C) Class H precast concrete pipes or stoneware pipes S=2.5, T=3.5 Nominal diameter of pipe 1050 mm |
| 181003B | (A) Class M precast concrete pipes or stoneware pipes S=2.5, T=3.5 Nominal diameter of pipe 100 mm |
| 181003C | (A) Class M precast concrete pipes or stoneware pipes S=2.5, T=3.5 Nominal diameter of pipe 150 mm |
| 181003D | (A) Class M precast concrete pipes or stoneware pipes S=2.5, T=3.5 Nominal diameter of pipe 225 mm |
| 181003E | (A) Class M precast concrete pipes or stoneware pipes S=2.5, T=3.5 Nominal diameter of pipe 300 mm |
| 181003F | (A) Class M precast concrete pipes or stoneware pipes S=2.5, T=3.5 Nominal diameter of pipe 375 mm |
| 181003G | (A) Class M precast concrete pipes or stoneware pipes S=2.5, T=3.5 Nominal diameter of pipe 450 mm |
| 181003H | (A) Class M precast concrete pipes or stoneware pipes S=2.5, T=3.5 Nominal diameter of pipe 600 mm |
| 181003I | (A) Class M precast concrete pipes or stoneware pipes S=2.5, T=3.5 Nominal diameter of pipe 750 mm |
| 181003J | (A) Class M precast concrete pipes or stoneware pipes S=2.5, T=3.5 Nominal diameter of pipe 900 mm |
| 181003K | (A) Class M precast concrete pipes or stoneware pipes S=2.5, T=3.5 Nominal diameter of pipe 1050 mm |
| 181004A | (A) Class M precast concrete pipes or stoneware pipes S=3.5, T=4.5 Nominal diameter of pipe 80 mm & under |
| 181004ae | (C) Class H precast concrete pipes or stoneware pipes S=3.5, T=4.5 Nominal diameter of pipe 300 mm |
| 181004af | (C) Class H precast concrete pipes or stoneware pipes S=3.5, T=4.5 Nominal diameter of pipe 375 mm |
| 181004ag | (C) Class H precast concrete pipes or stoneware pipes S=3.5, T=4.5 Nominal diameter of pipe 450 mm |
| 181004ah | (C) Class H precast concrete pipes or stoneware pipes S=3.5, T=4.5 Nominal diameter of pipe 600 mm |
| 181004ai | (C) Class H precast concrete pipes or stoneware pipes S=3.5, T=4.5 Nominal diameter of pipe 750 mm |
| 181004aj | (C) Class H precast concrete pipes or stoneware pipes S=3.5, T=4.5 Nominal diameter of pipe 900mm |
| 181004ak | (C) Class H precast concrete pipes or stoneware pipes S=3.5, T=4.5 Nominal diameter of pipe 1050 mm |
| 181004B | (A) Class M precast concrete pipes or stoneware pipes S=3.5, T=4.5 Nominal diameter of pipe 100 mm |
| 181004C | (A) Class M precast concrete pipes or stoneware pipes S=3.5, T=4.5 Nominal diameter of pipe 150 mm |
| 181004D | (A) Class M precast concrete pipes or stoneware pipes S=3.5, T=4.5 Nominal diameter of pipe 225 mm |
| 181004E | (A) Class M precast concrete pipes or stoneware pipes S=3.5, T=4.5 Nominal diameter of pipe 300 mm |
| 181004F | (A) Class M precast concrete pipes or stoneware pipes S=3.5, T=4.5 Nominal diameter of pipe 375 mm |
| 181004G | (A) Class M precast concrete pipes or stoneware pipes S=3.5, T=4.5 Nominal diameter of pipe 450 mm |
| 181004H | (A) Class M precast concrete pipes or stoneware pipes S=3.5, T=4.5 Nominal diameter of pipe 600 mm |
| 181004I | (A) Class M precast concrete pipes or stoneware pipes S=3.5, T=4.5 Nominal diameter of pipe 750 mm |
| 181004J | (A) Class M precast concrete pipes or stoneware pipes S=3.5, T=4.5 Nominal diameter of pipe 900 mm |
| 181004K | (A) Class M precast concrete pipes or stoneware pipes S=3.5, T=4.5 Nominal diameter of pipe 1050 mm |
| 181005A | (A) Class M precast concrete pipes or stoneware pipes S=4.5, T=5.5 Nominal diameter of pipe 80 mm & under |
| 181005ae | (C) Class H precast concrete pipes or stoneware pipes S=4.5, T=5.5 Nominal diameter of pipe 300 mm |
| 181005af | (C) Class H precast concrete pipes or stoneware pipes S=4.5, T=5.5 Nominal diameter of pipe 375 mm |
| 181005ag | (C) Class H precast concrete pipes or stoneware pipes S=4.5, T=5.5 Nominal diameter of pipe 450 mm |
| 181005ah | (C) Class H precast concrete pipes or stoneware pipes S=4.5, T=5.5 Nominal diameter of pipe 600 mm |
| 181005ai | (C) Class H precast concrete pipes or stoneware pipes S=4.5, T=5.5 Nominal diameter of pipe 750 mm |
| 181005aj | (C) Class H precast concrete pipes or stoneware pipes S=4.5, T=5.5 Nominal diameter of pipe 900mm |
| 181005ak | (C) Class H precast concrete pipes or stoneware pipes S=4.5, T=5.5 Nominal diameter of pipe 1050 mm |
| 181005B | (A) Class M precast concrete pipes or stoneware pipes S=4.5, T=5.5 Nominal diameter of pipe 100 mm |
| 181005C | (A) Class M precast concrete pipes or stoneware pipes S=4.5, T=5.5 Nominal diameter of pipe 150 mm |
| 181005D | (A) Class M precast concrete pipes or stoneware pipes S=4.5, T=5.5 Nominal diameter of pipe 225 mm |
| 181005E | (A) Class M precast concrete pipes or stoneware pipes S=4.5, T=5.5 Nominal diameter of pipe 300 mm |
| 181005F | (A) Class M precast concrete pipes or stoneware pipes S=4.5, T=5.5 Nominal diameter of pipe 375 mm |
| 181005G | (A) Class M precast concrete pipes or stoneware pipes S=4.5, T=5.5 Nominal diameter of pipe 450 mm |
| 181005H | (A) Class M precast concrete pipes or stoneware pipes S=4.5, T=5.5 Nominal diameter of pipe 600 mm |
| 181005I | (A) Class M precast concrete pipes or stoneware pipes S=4.5, T=5.5 Nominal diameter of pipe 750 mm |
| 181005J | (A) Class M precast concrete pipes or stoneware pipes S=4.5, T=5.5 Nominal diameter of pipe 900 mm |
| 181005K | (A) Class M precast concrete pipes or stoneware pipes S=4.5, T=5.5 Nominal diameter of pipe 1050 mm |
| 181006A | (A) Class M precast concrete pipes or stoneware pipes S=5.5, T=6.5 Nominal diameter of pipe 80 mm & under |
| 181006ae | (C) Class H precast concrete pipes or stoneware pipes S=5.5, T=6.5 Nominal diameter of pipe 300 mm |
| 181006af | (C) Class H precast concrete pipes or stoneware pipes S=5.5, T=6.5 Nominal diameter of pipe 375 mm |
| 181006ag | (C) Class H precast concrete pipes or stoneware pipes S=5.5, T=6.5 Nominal diameter of pipe 450 mm |
| 181006ah | (C) Class H precast concrete pipes or stoneware pipes S=5.5, T=6.5 Nominal diameter of pipe 600 mm |
| 181006ai | (C) Class H precast concrete pipes or stoneware pipes S=5.5, T=6.5 Nominal diameter of pipe 750 mm |
| 181006aj | (C) Class H precast concrete pipes or stoneware pipes S=5.5, T=6.5 Nominal diameter of pipe 900mm |
| 181006ak | (C) Class H precast concrete pipes or stoneware pipes S=5.5, T=6.5 Nominal diameter of pipe 1050 mm |
| 181006B | (A) Class M precast concrete pipes or stoneware pipes S=5.5, T=6.5 Nominal diameter of pipe 100 mm |
| 181006C | (A) Class M precast concrete pipes or stoneware pipes S=5.5, T=6.5 Nominal diameter of pipe 150 mm |
| 181006D | (A) Class M precast concrete pipes or stoneware pipes S=5.5, T=6.5 Nominal diameter of pipe 225 mm |
| 181006E | (A) Class M precast concrete pipes or stoneware pipes S=5.5, T=6.5 Nominal diameter of pipe 300 mm |
| 181006F | (A) Class M precast concrete pipes or stoneware pipes S=5.5, T=6.5 Nominal diameter of pipe 375 mm |
| 181006G | (A) Class M precast concrete pipes or stoneware pipes S=5.5, T=6.5 Nominal diameter of pipe 450 mm |
| 181006H | (A) Class M precast concrete pipes or stoneware pipes S=5.5, T=6.5 Nominal diameter of pipe 600 mm |
| 181006I | (A) Class M precast concrete pipes or stoneware pipes S=5.5, T=6.5 Nominal diameter of pipe 750 mm |
| 181006J | (A) Class M precast concrete pipes or stoneware pipes S=5.5, T=6.5 Nominal diameter of pipe 900 mm |
| 181006K | (A) Class M precast concrete pipes or stoneware pipes S=5.5, T=6.5 Nominal diameter of pipe 1050 mm |
| 181007A | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 80 mm & under |
| 181007ae | (D) Class H precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 300 mm |
| 181007af | (D) Class H precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 375 mm |
| 181007ag | (D) Class H precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 450 mm |
| 181007ah | (D) Class H precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 600 mm |
| 181007ai | (D) Class H precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 750 mm |
| 181007aj | (D) Class H precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 900mm |
| 181007ak | (D) Class H precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 1050 mm |
| 181007B | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 100 mm |
| 181007C | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 150 mm |
| 181007D | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 225 mm |
| 181007E | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 300 mm |
| 181007F | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 375 mm |
| 181007G | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 450 mm |
| 181007H | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 600 mm |
| 181007I | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 750 mm |
| 181007J | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 900 mm |
| 181007K | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 1050 mm |
| 181008A | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 80 mm & under |
| 181008ae | (D) Class H precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 300 mm |
| 181008af | (D) Class H precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 375 mm |
| 181008ag | (D) Class H precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 450 mm |
| 181008ah | (D) Class H precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 600 mm |
| 181008ai | (D) Class H precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 750 mm |
| 181008aj | (D) Class H precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 900mm |
| 181008ak | (D) Class H precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 1050 mm |
| 181008B | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 100 mm |
| 181008C | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 150 mm |
| 181008D | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 225 mm |
| 181008E | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 300 mm |
| 181008F | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 375 mm |
| 181008G | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 450 mm |
| 181008H | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 600 mm |
| 181008I | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 750 mm |
| 181008J | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 900 mm |
| 181008K | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 1050 mm |
| 181009A | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 80 mm & under |
| 181009ae | (D) Class H precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 300 mm |
| 181009af | (D) Class H precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 375 mm |
| 181009ag | (D) Class H precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 450 mm |
| 181009ah | (D) Class H precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 600 mm |
| 181009ai | (D) Class H precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 750 mm |
| 181009aj | (D) Class H precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 900mm |
| 181009ak | (D) Class H precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 1050 mm |
| 181009B | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 100 mm |
| 181009C | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 150 mm |
| 181009D | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 225 mm |
| 181009E | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 300 mm |
| 181009F | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 375 mm |
| 181009G | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 450 mm |
| 181009H | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 600 mm |
| 181009I | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 750 mm |
| 181009J | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 900 mm |
| 181009K | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 1050 mm |
| 181010A | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 80 mm & under |
| 181010ae | (D) Class H precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 300 mm |
| 181010af | (D) Class H precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 375 mm |
| 181010ag | (D) Class H precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 450 mm |
| 181010ah | (D) Class H precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 600 mm |
| 181010ai | (D) Class H precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 750 mm |
| 181010aj | (D) Class H precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 900mm |
| 181010ak | (D) Class H precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 1050 mm |
| 181010B | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 100 mm |
| 181010C | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 150 mm |
| 181010D | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 225 mm |
| 181010E | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 300 mm |
| 181010F | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 375 mm |
| 181010G | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 450 mm |
| 181010H | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 600 mm |
| 181010I | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 750 mm |
| 181010J | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 900 mm |
| 181010K | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 1050 mm |
| 181011A | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 80 mm & under |
| 181011ae | (D) Class H precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 300 mm |
| 181011af | (D) Class H precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 375 mm |
| 181011ag | (D) Class H precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 450 mm |
| 181011ah | (D) Class H precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 600 mm |
| 181011ai | (D) Class H precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 750 mm |
| 181011aj | (D) Class H precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 900mm |
| 181011ak | (D) Class H precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 1050 mm |
| 181011B | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 100 mm |
| 181011C | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 150 mm |
| 181011D | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 225 mm |
| 181011E | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 300 mm |
| 181011F | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 375 mm |
| 181011G | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 450 mm |
| 181011H | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 600 mm |
| 181011I | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 750 mm |
| 181011J | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 900 mm |
| 181011K | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 1050 mm |
| 181012A | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 80 mm & under |
| 181012ae | (D) Class H precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 300 mm |
| 181012af | (D) Class H precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 375 mm |
| 181012ag | (D) Class H precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 450 mm |
| 181012ah | (D) Class H precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 600 mm |
| 181012ai | (D) Class H precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 750 mm |
| 181012aj | (D) Class H precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 900mm |
| 181012ak | (D) Class H precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 1050 mm |
| 181012B | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 100 mm |
| 181012C | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 150 mm |
| 181012D | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 225 mm |
| 181012E | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 300 mm |
| 181012F | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 375 mm |
| 181012G | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 450 mm |
| 181012H | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 600 mm |
| 181012I | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 750 mm |
| 181012J | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 900 mm |
| 181012K | (B) Class M precast concrete pipes or stoneware pipes with granular material bed as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 1050 mm |
| 181013A | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 80 mm & under |
| 181013ae | (G) Class H precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 300 mm |
| 181013af | (G) Class H precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 375 mm |
| 181013ag | (G) Class H precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 450 mm |
| 181013ah | (G) Class H precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 600 mm |
| 181013ai | (G) Class H precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 750 mm |
| 181013aj | (G) Class H precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 900mm |
| 181013ak | (G) Class H precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 1050 mm |
| 181013B | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 100 mm |
| 181013C | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 150 mm |
| 181013D | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 225 mm |
| 181013E | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 300 mm |
| 181013F | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 375 mm |
| 181013G | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 450 mm |
| 181013H | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 600 mm |
| 181013I | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 750 mm |
| 181013J | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 900 mm |
| 181013K | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 1050 mm |
| 181014A | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 80 mm & under |
| 181014ae | (G) Class H precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 300 mm |
| 181014af | (G) Class H precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 375 mm |
| 181014ag | (G) Class H precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 450 mm |
| 181014ah | (G) Class H precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 600 mm |
| 181014ai | (G) Class H precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 750 mm |
| 181014aj | (G) Class H precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 900mm |
| 181014ak | (G) Class H precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 1050 mm |
| 181014B | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1C S=1.5, T=2.5 Nominal diameter of pipe 100 mm |
| 181014C | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 150 mm |
| 181014D | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 225 mm |
| 181014E | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 300 mm |
| 181014F | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 375 mm |
| 181014G | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 450 mm |
| 181014H | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 600 mm |
| 181014I | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 750 mm |
| 181014J | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 900 mm |
| 181014K | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 1050 mm |
| 181015A | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 80 mm & under |
| 181015ae | (G) Class H precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 300 mm |
| 181015af | (G) Class H precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 375 mm |
| 181015ag | (G) Class H precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 450 mm |
| 181015ah | (G) Class H precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 600 mm |
| 181015ai | (G) Class H precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 750 mm |
| 181015aj | (G) Class H precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 900mm |
| 181015ak | (G) Class H precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 1050 mm |
| 181015B | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 100 mm |
| 181015C | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 150 mm |
| 181015D | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 225 mm |
| 181015E | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 300 mm |
| 181015F | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 375 mm |
| 181015G | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 450 mm |
| 181015H | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 600 mm |
| 181015I | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 750 mm |
| 181015J | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 900 mm |
| 181015K | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 1050 mm |
| 181016A | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 80 mm & under |
| 181016ae | (G) Class H precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 300 mm |
| 181016af | (G) Class H precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 375 mm |
| 181016ag | (G) Class H precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 450 mm |
| 181016ah | (G) Class H precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 600 mm |
| 181016ai | (G) Class H precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 750 mm |
| 181016aj | (G) Class H precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 900mm |
| 181016ak | (G) Class H precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 1050 mm |
| 181016B | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 100 mm |
| 181016C | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 150 mm |
| 181016D | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 225 mm |
| 181016E | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 300 mm |
| 181016F | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 375 mm |
| 181016G | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 450 mm |
| 181016H | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 600 mm |
| 181016I | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 750 mm |
| 181016J | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 900 mm |
| 181016K | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 1050 mm |
| 181017A | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 80 mm & under |
| 181017ae | (G) Class H precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 300 mm |
| 181017af | (G) Class H precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 375 mm |
| 181017ag | (G) Class H precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 450 mm |
| 181017ah | (G) Class H precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 600 mm |
| 181017ai | (G) Class H precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 750 mm |
| 181017aj | (G) Class H precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 900mm |
| 181017ak | (G) Class H precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 1050 mm |
| 181017B | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 100 mm |
| 181017C | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 150 mm |
| 181017D | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 225 mm |
| 181017E | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 300 mm |
| 181017F | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 375 mm |
| 181017G | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 450 mm |
| 181017H | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 600 mm |
| 181017I | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 750 mm |
| 181017J | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 900 mm |
| 181017K | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 1050 mm |
| 181018A | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 80 mm & under |
| 181018ae | (G) Class H precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 300 mm |
| 181018af | (G) Class H precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 375 mm |
| 181018ag | (G) Class H precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 450 mm |
| 181018ah | (G) Class H precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 600 mm |
| 181018ai | (G) Class H precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 750 mm |
| 181018aj | (G) Class H precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 900mm |
| 181018ak | (G) Class H precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 1050 mm |
| 181018B | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 100 mm |
| 181018C | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 150 mm |
| 181018D | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 225 mm |
| 181018E | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 300 mm |
| 181018F | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 375 mm |
| 181018G | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 450 mm |
| 181018H | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 600 mm |
| 181018I | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 750 mm |
| 181018J | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 900 mm |
| 181018K | (E) Class M precast concrete pipes or stoneware pipes with concrete haunching as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 1050 mm |
| 181019A | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 80 mm & under |
| 181019ae | (H) Class H precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 300 mm |
| 181019af | (H) Class H precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 375 mm |
| 181019ag | (H) Class H precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 450 mm |
| 181019ah | (H) Class H precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 600 mm |
| 181019ai | (H) Class H precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 750 mm |
| 181019aj | (H) Class H precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 900mm |
| 181019ak | (H) Class H precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 1050 mm |
| 181019B | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 100 mm |
| 181019C | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 150 mm |
| 181019D | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 225 mm |
| 181019E | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 300 mm |
| 181019F | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 375 mm |
| 181019G | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 450 mm |
| 181019H | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 600 mm |
| 181019I | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 750 mm |
| 181019J | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 900 mm |
| 181019K | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=0, T=1.5 Nominal diameter of pipe 1050 mm |
| 181020A | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 80 mm & under |
| 181020ae | (H) Class H precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 300 mm |
| 181020af | (H) Class H precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 375 mm |
| 181020ag | (H) Class H precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 450 mm |
| 181020ah | (H) Class H precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 600 mm |
| 181020ai | (H) Class H precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 750 mm |
| 181020aj | (H) Class H precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 900mm |
| 181020ak | (H) Class H precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 1050 mm |
| 181020B | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 100 mm |
| 181020C | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 150 mm |
| 181020D | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 225 mm |
| 181020E | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 300 mm |
| 181020F | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 375 mm |
| 181020G | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 450 mm |
| 181020H | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 600 mm |
| 181020I | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 750 mm |
| 181020J | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 900 mm |
| 181020K | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=1.5, T=2.5 Nominal diameter of pipe 1050 mm |
| 181021A | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 80 mm & under |
| 181021ae | (H) Class H precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 300 mm |
| 181021af | (H) Class H precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 375 mm |
| 181021ag | (H) Class H precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 450 mm |
| 181021ah | (H) Class H precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 600 mm |
| 181021ai | (H) Class H precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 750 mm |
| 181021aj | (H) Class H precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 900mm |
| 181021ak | (H) Class H precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 1050 mm |
| 181021B | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 100 mm |
| 181021C | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 150 mm |
| 181021D | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1C S=2.5, T=3.5 Nominal diameter of pipe 225 mm |
| 181021E | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 300 mm |
| 181021F | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 375 mm |
| 181021G | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 450 mm |
| 181021H | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 600 mm |
| 181021I | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 750 mm |
| 181021J | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 900 mm |
| 181021K | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=2.5, T=3.5 Nominal diameter of pipe 1050 mm |
| 181022A | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 80 mm & under |
| 181022ae | (H) Class H precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 300 mm |
| 181022af | (H) Class H precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 375 mm |
| 181022ag | (H) Class H precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 450 mm |
| 181022ah | (H) Class H precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 600 mm |
| 181022ai | (H) Class H precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 750 mm |
| 181022aj | (H) Class H precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 900mm |
| 181022ak | (H) Class H precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 1050 mm |
| 181022B | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 100 mm |
| 181022C | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 150 mm |
| 181022D | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 225 mm |
| 181022E | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 300 mm |
| 181022F | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 375 mm |
| 181022G | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 450 mm |
| 181022H | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 600 mm |
| 181022I | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 750 mm |
| 181022J | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 900 mm |
| 181022K | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=3.5, T=4.5 Nominal diameter of pipe 1050 mm |
| 181023A | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 80 mm & under |
| 181023ae | (H) Class H precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 300 mm |
| 181023af | (H) Class H precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 375 mm |
| 181023ag | (H) Class H precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 450 mm |
| 181023ah | (H) Class H precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 600 mm |
| 181023ai | (H) Class H precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 750 mm |
| 181023aj | (H) Class H precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 900mm |
| 181023ak | (H) Class H precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 1050 mm |
| 181023B | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 100 mm |
| 181023C | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 150 mm |
| 181023D | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 225 mm |
| 181023E | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 300 mm |
| 181023F | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 375 mm |
| 181023G | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 450 mm |
| 181023H | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 600 mm |
| 181023I | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 750 mm |
| 181023J | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 900 mm |
| 181023K | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=4.5, T=5.5 Nominal diameter of pipe 1050 mm |
| 181024A | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 80 mm & under |
| 181024ae | (H) Class H precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 300 mm |
| 181024af | (H) Class H precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 375 mm |
| 181024ag | (H) Class H precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 450 mm |
| 181024ah | (H) Class H precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 600 mm |
| 181024ai | (H) Class H precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 750 mm |
| 181024aj | (H) Class H precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 900mm |
| 181024ak | (H) Class H precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 1050 mm |
| 181024B | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 100 mm |
| 181024C | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 150 mm |
| 181024D | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 225 mm |
| 181024E | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 300 mm |
| 181024F | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 375 mm |
| 181024G | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 450 mm |
| 181024H | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 600 mm |
| 181024I | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 750 mm |
| 181024J | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 900 mm |
| 181024K | (F) Class M precast concrete pipes or stoneware pipes with concrete surround as shown in Drawing No. WSD 1.1 S=5.5, T=6.5 Nominal diameter of pipe 1050 mm |
| 181019ac | (I) Class 120 vitrified clay pipe with concrete surround as shwon in DSD Standard Drawing No. DS1049 S=0, T=1.5 Nominal diameter of pipe 150 mm |
| 181019ad | (I) Class 120 vitrified clay pipe with concrete surround as shwon in DSD Standard Drawing No. DS1049 S=0, T=1.5 Nominal diameter of pipe 225 mm |
| 181019ae | (I) Class 120 vitrified clay pipe with concrete surround as shwon in DSD Standard Drawing No. DS1049 S=0, T=1.5 Nominal diameter of pipe 300 mm |
| 181019af | (I) Class 120 vitrified clay pipe with concrete surround as shwon in DSD Standard Drawing No. DS1049 S=0, T=1.5 Nominal diameter of pipe 375 mm |
| 181019ag | (I) Class 120 vitrified clay pipe with concrete surround as shwon in DSD Standard Drawing No. DS1049 S=0, T=1.5 Nominal diameter of pipe 450 mm |
| 181019ah | (I) Class 120 vitrified clay pipe with concrete surround as shwon in DSD Standard Drawing No. DS1049 S=0, T=1.5 Nominal diameter of pipe 600 mm |
| 181020ac | (I) Class 120 vitrified clay pipe with concrete surround as shwon in DSD Standard Drawing No. DS1049 S=1.5, T=2.5 Nominal diameter of pipe 150 mm |
| 181020ad | (I) Class 120 vitrified clay pipe with concrete surround as shwon in DSD Standard Drawing No. DS1049 S=1.5, T=2.5 Nominal diameter of pipe 225 mm |
| 181020ae | (I) Class 120 vitrified clay pipe with concrete surround as shwon in DSD Standard Drawing No. DS1049 S=1.5, T=2.5 Nominal diameter of pipe 300 mm |
| 181020af | (I) Class 120 vitrified clay pipe with concrete surround as shwon in DSD Standard Drawing No. DS1049 S=1.5, T=2.5 Nominal diameter of pipe 375 mm |
| 181020ag | (I) Class 120 vitrified clay pipe with concrete surround as shwon in DSD Standard Drawing No. DS1049 S=1.5, T=2.5 Nominal diameter of pipe 450 mm |
| 181020ah | (I) Class 120 vitrified clay pipe with concrete surround as shwon in DSD Standard Drawing No. DS1049 S=1.5, T=2.5 Nominal diameter of pipe 600 mm |
| 181021ac | (I) Class 120 vitrified clay pipe with concrete surround as shwon in DSD Standard Drawing No. DS1049 S=2.5, T=3.5 Nominal diameter of pipe 150 mm |
| 181021ad | (I) Class 120 vitrified clay pipe with concrete surround as shwon in DSD Standard Drawing No. DS1049 S=2.5, T=3.5 Nominal diameter of pipe 225 mm |
| 181021ae | (I) Class 120 vitrified clay pipe with concrete surround as shwon in DSD Standard Drawing No. DS1049 S=2.5, T=3.5 Nominal diameter of pipe 300 mm |
| 181021af | (I) Class 120 vitrified clay pipe with concrete surround as shwon in DSD Standard Drawing No. DS1049 S=2.5, T=3.5 Nominal diameter of pipe 375 mm |
| 181021ag | (I) Class 120 vitrified clay pipe with concrete surround as shwon in DSD Standard Drawing No. DS1049 S=2.5, T=3.5 Nominal diameter of pipe 450 mm |
| 181021ah | (I) Class 120 vitrified clay pipe with concrete surround as shwon in DSD Standard Drawing No. DS1049 S=2.5, T=3.5 Nominal diameter of pipe 600 mm |
| 181022ac | (I) Class 120 vitrified clay pipe with concrete surround as shwon in DSD Standard Drawing No. DS1049 S=3.5, T=4.5 Nominal diameter of pipe 150 mm |
| 181022ad | (I) Class 120 vitrified clay pipe with concrete surround as shwon in DSD Standard Drawing No. DS1049 S=3.5, T=4.5 Nominal diameter of pipe 225 mm |
| 181022ae | (I) Class 120 vitrified clay pipe with concrete surround as shwon in DSD Standard Drawing No. DS1049 S=3.5, T=4.5 Nominal diameter of pipe 300 mm |
| 181022af | (I) Class 120 vitrified clay pipe with concrete surround as shwon in DSD Standard Drawing No. DS1049 S=3.5, T=4.5 Nominal diameter of pipe 375 mm |
| 181022ag | (I) Class 120 vitrified clay pipe with concrete surround as shwon in DSD Standard Drawing No. DS1049 S=3.5, T=4.5 Nominal diameter of pipe 450 mm |
| 181022ah | (I) Class 120 vitrified clay pipe with concrete surround as shwon in DSD Standard Drawing No. DS1049 S=3.5, T=4.5 Nominal diameter of pipe 600 mm |
| 181023ac | (I) Class 120 vitrified clay pipe with concrete surround as shwon in DSD Standard Drawing No. DS1049 S=4.5, T=5.5 Nominal diameter of pipe 150 mm |
| 181023ad | (I) Class 120 vitrified clay pipe with concrete surround as shwon in DSD Standard Drawing No. DS1049 S=4.5, T=5.5 Nominal diameter of pipe 225 mm |
| 181023ae | (I) Class 120 vitrified clay pipe with concrete surround as shwon in DSD Standard Drawing No. DS1049 S=4.5, T=5.5 Nominal diameter of pipe 300 mm |
| 181023af | (I) Class 120 vitrified clay pipe with concrete surround as shwon in DSD Standard Drawing No. DS1049 S=4.5, T=5.5 Nominal diameter of pipe 375 mm |
| 181023ag | (I) Class 120 vitrified clay pipe with concrete surround as shwon in DSD Standard Drawing No. DS1049 S=4.5, T=5.5 Nominal diameter of pipe 450 mm |
| 181023ah | (I) Class 120 vitrified clay pipe with concrete surround as shwon in DSD Standard Drawing No. DS1049 S=4.5, T=5.5 Nominal diameter of pipe 600 mm |
| 181024ac | (I) Class 120 vitrified clay pipe with concrete surround as shwon in DSD Standard Drawing No. DS1049 S=5.5, T=6.5 Nominal diameter of pipe 150 mm |
| 181024ad | (I) Class 120 vitrified clay pipe with concrete surround as shwon in DSD Standard Drawing No. DS1049 S=5.5, T=6.5 Nominal diameter of pipe 225 mm |
| 181024ae | (I) Class 120 vitrified clay pipe with concrete surround as shwon in DSD Standard Drawing No. DS1049 S=5.5, T=6.5 Nominal diameter of pipe 300 mm |
| 181024af | (I) Class 120 vitrified clay pipe with concrete surround as shwon in DSD Standard Drawing No. DS1049 S=5.5, T=6.5 Nominal diameter of pipe 375 mm |
| 181024ag | (I) Class 120 vitrified clay pipe with concrete surround as shwon in DSD Standard Drawing No. DS1049 S=5.5, T=6.5 Nominal diameter of pipe 450 mm |
| 181024ah | (I) Class 120 vitrified clay pipe with concrete surround as shwon in DSD Standard Drawing No. DS1049 S=5.5, T=6.5 Nominal diameter of pipe 600 mm |
| 181019bc | (J) Class 120 vitrified clay pipe with 120o plain concrete bedding as shwon in DSD Standard Drawing No. DS1048 S=0, T=1.5 Nominal diameter of pipe 150 mm |
| 181019bd | (J) Class 120 vitrified clay pipe with 120o plain concrete bedding as shwon in DSD Standard Drawing No. DS1048 S=0, T=1.5 Nominal diameter of pipe 225 mm |
| 181019be | (J) Class 120 vitrified clay pipe with 120o plain concrete bedding as shwon in DSD Standard Drawing No. DS1048 S=0, T=1.5 Nominal diameter of pipe 300 mm |
| 181019bf | (J) Class 120 vitrified clay pipe with 120o plain concrete bedding as shwon in DSD Standard Drawing No. DS1048 S=0, T=1.5 Nominal diameter of pipe 375 mm |
| 181019bg | (J) Class 120 vitrified clay pipe with 120o plain concrete bedding as shwon in DSD Standard Drawing No. DS1048 S=0, T=1.5 Nominal diameter of pipe 450 mm |
| 181019bh | (J) Class 120 vitrified clay pipe with 120o plain concrete bedding as shwon in DSD Standard Drawing No. DS1048 S=0, T=1.5 Nominal diameter of pipe 600 mm |
| 181020bc | (J) Class 120 vitrified clay pipe with 120o plain concrete bedding as shwon in DSD Standard Drawing No. DS1048 S=1.5, T=2.5 Nominal diameter of pipe 150 mm |
| 181020bd | (J) Class 120 vitrified clay pipe with 120o plain concrete bedding as shwon in DSD Standard Drawing No. DS1048 S=1.5, T=2.5 Nominal diameter of pipe 225 mm |
| 181020be | (J) Class 120 vitrified clay pipe with 120o plain concrete bedding as shwon in DSD Standard Drawing No. DS1048 S=1.5, T=2.5 Nominal diameter of pipe 300 mm |
| 181020bf | (J) Class 120 vitrified clay pipe with 120o plain concrete bedding as shwon in DSD Standard Drawing No. DS1048 S=1.5, T=2.5 Nominal diameter of pipe 375 mm |
| 181020bg | (J) Class 120 vitrified clay pipe with 120o plain concrete bedding as shwon in DSD Standard Drawing No. DS1048 S=1.5, T=2.5 Nominal diameter of pipe 450 mm |
| 181020bh | (J) Class 120 vitrified clay pipe with 120o plain concrete bedding as shwon in DSD Standard Drawing No. DS1048 S=1.5, T=2.5 Nominal diameter of pipe 600 mm |
| 181021bc | (J) Class 120 vitrified clay pipe with 120o plain concrete bedding as shwon in DSD Standard Drawing No. DS1048 S=2.5, T=3.5 Nominal diameter of pipe 150 mm |
| 181021bd | (J) Class 120 vitrified clay pipe with 120o plain concrete bedding as shwon in DSD Standard Drawing No. DS1048 S=2.5, T=3.5 Nominal diameter of pipe 225 mm |
| 181021be | (J) Class 120 vitrified clay pipe with 120o plain concrete bedding as shwon in DSD Standard Drawing No. DS1048 S=2.5, T=3.5 Nominal diameter of pipe 300 mm |
| 181021bf | (J) Class 120 vitrified clay pipe with 120o plain concrete bedding as shwon in DSD Standard Drawing No. DS1048 S=2.5, T=3.5 Nominal diameter of pipe 375 mm |
| 181021bg | (J) Class 120 vitrified clay pipe with 120o plain concrete bedding as shwon in DSD Standard Drawing No. DS1048 S=2.5, T=3.5 Nominal diameter of pipe 450 mm |
| 181021bh | (J) Class 120 vitrified clay pipe with 120o plain concrete bedding as shwon in DSD Standard Drawing No. DS1048 S=2.5, T=3.5 Nominal diameter of pipe 600 mm |
| 181022bc | (J) Class 120 vitrified clay pipe with 120o plain concrete bedding as shwon in DSD Standard Drawing No. DS1048 S=3.5, T=4.5 Nominal diameter of pipe 150 mm |
| 181022bd | (J) Class 120 vitrified clay pipe with 120o plain concrete bedding as shwon in DSD Standard Drawing No. DS1048 S=3.5, T=4.5 Nominal diameter of pipe 225 mm |
| 181022be | (J) Class 120 vitrified clay pipe with 120o plain concrete bedding as shwon in DSD Standard Drawing No. DS1048 S=3.5, T=4.5 Nominal diameter of pipe 300 mm |
| 181022bf | (J) Class 120 vitrified clay pipe with 120o plain concrete bedding as shwon in DSD Standard Drawing No. DS1048 S=3.5, T=4.5 Nominal diameter of pipe 375 mm |
| 181022bg | (J) Class 120 vitrified clay pipe with 120o plain concrete bedding as shwon in DSD Standard Drawing No. DS1048 S=3.5, T=4.5 Nominal diameter of pipe 450 mm |
| 181022bh | (J) Class 120 vitrified clay pipe with 120o plain concrete bedding as shwon in DSD Standard Drawing No. DS1048 S=3.5, T=4.5 Nominal diameter of pipe 600 mm |
| 181023bc | (J) Class 120 vitrified clay pipe with 120o plain concrete bedding as shwon in DSD Standard Drawing No. DS1048 S=4.5, T=5.5 Nominal diameter of pipe 150 mm |
| 181023bd | (J) Class 120 vitrified clay pipe with 120o plain concrete bedding as shwon in DSD Standard Drawing No. DS1048 S=4.5, T=5.5 Nominal diameter of pipe 225 mm |
| 181023be | (J) Class 120 vitrified clay pipe with 120o plain concrete bedding as shwon in DSD Standard Drawing No. DS1048 S=4.5, T=5.5 Nominal diameter of pipe 300 mm |
| 181023bf | (J) Class 120 vitrified clay pipe with 120o plain concrete bedding as shwon in DSD Standard Drawing No. DS1048 S=4.5, T=5.5 Nominal diameter of pipe 375 mm |
| 181023bg | (J) Class 120 vitrified clay pipe with 120o plain concrete bedding as shwon in DSD Standard Drawing No. DS1048 S=4.5, T=5.5 Nominal diameter of pipe 450 mm |
| 181023bh | (J) Class 120 vitrified clay pipe with 120o plain concrete bedding as shwon in DSD Standard Drawing No. DS1048 S=4.5, T=5.5 Nominal diameter of pipe 600 mm |
| 181024bc | (J) Class 120 vitrified clay pipe with 120o plain concrete bedding as shwon in DSD Standard Drawing No. DS1048 S=5.5, T=6.5 Nominal diameter of pipe 150 mm |
| 181024bd | (J) Class 120 vitrified clay pipe with 120o plain concrete bedding as shwon in DSD Standard Drawing No. DS1048 S=5.5, T=6.5 Nominal diameter of pipe 225 mm |
| 181024be | (J) Class 120 vitrified clay pipe with 120o plain concrete bedding as shwon in DSD Standard Drawing No. DS1048 S=5.5, T=6.5 Nominal diameter of pipe 300 mm |
| 181024bf | (J) Class 120 vitrified clay pipe with 120o plain concrete bedding as shwon in DSD Standard Drawing No. DS1048 S=5.5, T=6.5 Nominal diameter of pipe 375 mm |
| 181024bg | (J) Class 120 vitrified clay pipe with 120o plain concrete bedding as shwon in DSD Standard Drawing No. DS1048 S=5.5, T=6.5 Nominal diameter of pipe 450 mm |
| 181024bh | (J) Class 120 vitrified clay pipe with 120o plain concrete bedding as shwon in DSD Standard Drawing No. DS1048 S=5.5, T=6.5 Nominal diameter of pipe 600 mm |
| 181025A | UPVC cable ducts S=0, T=1.5 Nominal diameter of pipe 1 x 80 mm & under |
| 181025B | UPVC cable ducts S=0, T=1.5 Nominal diameter of pipe 2 x 80 mm & under |
| 181025C | UPVC cable ducts S=0, T=1.5 Nominal diameter of pipe 3 x 80 mm & under |
| 181025D | UPVC cable ducts S=0, T=1.5 Nominal diameter of pipe 1 x 100 mm |
| 181025E | UPVC cable ducts S=0, T=1.5 Nominal diameter of pipe 2 x 100 mm |
| 181025F | UPVC cable ducts S=0, T=1.5 Nominal diameter of pipe 3 x 100 mm |
| 181025G | UPVC cable ducts S=0, T=1.5 Nominal diameter of pipe 1 x 150 mm |
| 181025H | UPVC cable ducts S=0, T=1.5 Nominal diameter of pipe 2 x 150 mm |
| 181025I | UPVC cable ducts S=0, T=1.5 Nominal diameter of pipe 3 x 150 mm |
| 181026A | UPVC cable ducts S=1.5, T=2.5 Nominal diameter of pipe 1 x 80 mm & under |
| 181026B | UPVC cable ducts S=1.5, T=2.5 Nominal diameter of pipe 2 x 80 mm & under |
| 181026C | UPVC cable ducts S=1.5, T=2.5 Nominal diameter of pipe 3 x 80 mm & under |
| 181026D | UPVC cable ducts S=1.5, T=2.5 Nominal diameter of pipe 1 x 100 mm |
| 181026E | UPVC cable ducts S=1.5, T=2.5 Nominal diameter of pipe 2 x 100 mm |
| 181026F | UPVC cable ducts S=1.5, T=2.5 Nominal diameter of pipe 3 x 100 mm |
| 181026G | UPVC cable ducts S=1.5, T=2.5 Nominal diameter of pipe 1 x 150 mm |
| 181026H | UPVC cable ducts S=1.5, T=2.5 Nominal diameter of pipe 2 x 150 mm |
| 181026I | UPVC cable ducts S=1.5, T=2.5 Nominal diameter of pipe 3 x 150 mm |
| 181027A | Medium grade galvanised steel ducts S=0, T=1.5 Nominal diameter of pipe 1 x 80 mm & under |
| 181027B | Medium grade galvanised steel ducts S=0, T=1.5 Nominal diameter of pipe 2 x 80 mm & under |
| 181027C | Medium grade galvanised steel ducts S=0, T=1.5 Nominal diameter of pipe 3 x 80 mm & under |
| 181027D | Medium grade galvanised steel ducts S=0, T=1.5 Nominal diameter of pipe 1 x 100 mm |
| 181027E | Medium grade galvanised steel ducts S=0, T=1.5 Nominal diameter of pipe 2 x 100 mm |
| 181027F | Medium grade galvanised steel ducts S=0, T=1.5 Nominal diameter of pipe 3 x 100 mm |
| 181027G | Medium grade galvanised steel ducts S=0, T=1.5 Nominal diameter of pipe 1 x 150 mm |
| 181027H | Medium grade galvanised steel ducts S=0, T=1.5 Nominal diameter of pipe 2 x 150 mm |
| 181027I | Medium grade galvanised steel ducts S=0, T=1.5 Nominal diameter of pipe 3 x 150 mm |
| 181028A | Medium grade galvanised steel ducts S=1.5, T=2.5 Nominal diameter of pipe 1 x 80 mm & under |
| 181028B | Medium grade galvanised steel ducts S=1.5, T=2.5 Nominal diameter of pipe 2 x 80 mm & under |
| 181028C | Medium grade galvanised steel ducts S=1.5, T=2.5 Nominal diameter of pipe 3 x 80 mm & under |
| 181028D | Medium grade galvanised steel ducts S=1.5, T=2.5 Nominal diameter of pipe 1 x 100 mm |
| 181028E | Medium grade galvanised steel ducts S=1.5, T=2.5 Nominal diameter of pipe 2 x 100 mm |
| 181028F | Medium grade galvanised steel ducts S=1.5, T=2.5 Nominal diameter of pipe 3 x 100 mm |
| 181028G | Medium grade galvanised steel ducts S=1.5, T=2.5 Nominal diameter of pipe 1 x 150 mm |
| 181028H | Medium grade galvanised steel ducts S=1.5, T=2.5 Nominal diameter of pipe 2 x 150 mm |
| 181028I | Medium grade galvanised steel ducts S=1.5, T=2.5 Nominal diameter of pipe 3 x 150 mm |
| 181029A | Connection to existing drain Nominal diameter of pipe 80 mm & under |
| 181029B | Connection to existing drain Nominal diameter of pipe 100 mm |
| 181029C | Connection to existing drain Nominal diameter of pipe 150 mm |
| 181029D | Connection to existing drain Nominal diameter of pipe 225 mm |
| 181029E | Connection to existing drain Nominal diameter of pipe 300 mm |
| 181029F | Connection to existing drain Nominal diameter of pipe 375 mm |
| 181029G | Connection to existing drain Nominal diameter of pipe 450 mm |
| 181029H | Connection to existing drain Nominal diameter of pipe 600 mm |
| 181029I | Connection to existing drain Nominal diameter of pipe 900 mm |
| 181030A | Connection to existing duct Nominal diameter of pipe 80 mm & under |
| 181030B | Connection to existing duct Nominal diameter of pipe 100 mm |
| 181030C | Connection to existing duct Nominal diameter of pipe 150 mm |
| 181031A | Connection to existing culvert Nominal diameter of pipe 80 mm & under |
| 181031B | Connection to existing culvert Nominal diameter of pipe 100 mm |
| 181031C | Connection to existing culvert Nominal diameter of pipe 150 mm |
| 181031D | Connection to existing culvert Nominal diameter of pipe 225 mm |
| 181031E | Connection to existing culvert Nominal diameter of pipe 300 mm |
| 181031F | Connection to existing culvert Nominal diameter of pipe 375 mm |
| 181031G | Connection to existing culvert Nominal diameter of pipe 450 mm |
| 181031H | Connection to existing culvert Nominal diameter of pipe 600 mm |
| 181031I | Connection to existing culvert Nominal diameter of pipe 900 mm |
| 181032A | Connection to existing manhole Nominal diameter of pipe 80 mm & under |
| 181032B | Connection to existing manhole Nominal diameter of pipe 100 mm |
| 181032C | Connection to existing manhole Nominal diameter of pipe 150 mm |
| 181032D | Connection to existing manhole Nominal diameter of pipe 225 mm |
| 181032E | Connection to existing manhole Nominal diameter of pipe 300 mm |
| 181032F | Connection to existing manhole Nominal diameter of pipe 375 mm |
| 181032G | Connection to existing manhole Nominal diameter of pipe 450 mm |
| 181032H | Connection to existing manhole Nominal diameter of pipe 600 mm |
| 181032I | Connection to existing manhole Nominal diameter of pipe 900 mm |
| 181033A | Connection to existing other chamber Nominal diameter of pipe 80 mm & under |
| 181033B | Connection to existing other chamber Nominal diameter of pipe 100 mm |
| 181033C | Connection to existing other chamber Nominal diameter of pipe 150 mm |
| 181033D | Connection to existing other chamber Nominal diameter of pipe 225 mm |
| 181033E | Connection to existing other chamber Nominal diameter of pipe 300 mm |
| 181033F | Connection to existing other chamber Nominal diameter of pipe 375 mm |
| 181033G | Connection to existing other chamber Nominal diameter of pipe 450 mm |
| 181033H | Connection to existing other chamber Nominal diameter of pipe 600 mm |
| 181033I | Connection to existing other chamber Nominal diameter of pipe 900 mm |
| 181034A | Connection to existing drawpit Nominal diameter of pipe 80 mm & under |
| 181034B | Connection to existing drawpit Nominal diameter of pipe 100 mm |
| 181035 | Supply and fix 80 mm diameter and under C.I. downpipes, ventpipes etc., including all bends, junctions, hopper heads, shoes, cleaning eyes anchor clips etc. |
| 181036 | Supply and fix 100 mm diameter and under C.I. downpipes, ventpipes etc., including all bends, junctions, hopper heads, shoes, cleaning eyes anchor clips etc. |
| 181037 | Supply and fix 50 mm diameter UPVC downpipes, ventpipes etc., including all bends, junctions, hopper heads, shoes, cleaning eyes anchor clips etc. |
| 181038 | Supply and fix 80 mm diameter UPVC downpipes, ventpipes etc., including all bends, junctions, hopper heads, shoes, cleaning eyes anchor clips etc. |
| 181039 | Supply and fix 100 mm diameter UPVC downpipes, ventpipes etc., including all bends, junctions, hopper heads, shoes, cleaning eyes anchor clips etc. |
| 181040 | Supply and fix 150 mm diameter UPVC downpipes, ventpipes etc., including all bends, junctions, hopper heads, shoes, cleaning eyes anchor clips etc. |
| 181041 | Supply and fix 200 mm diameter UPVC downpipes, ventpipes etc., including all bends, junctions, hopper heads, shoes, cleaning eyes anchor clips etc. |
| 181042 | Supply and fix 250 mm diameter UPVC downpipes, ventpipes etc., including all bends, junctions, hopper heads, shoes, cleaning eyes anchor clips etc. |
| 181043 | Supply and fix 300 mm diameter UPVC downpipes, ventpipes etc., including all bends, junctions, hopper heads, shoes, cleaning eyes anchor clips etc. |
| 181044 | Supply and fix 400 mm diameter UPVC downpipes, ventpipes etc., including all bends, junctions, hopper heads, shoes, cleaning eyes anchor clips etc. |
| 181045 | Supply and fix to top of ventpipes strong copper wire balloon grating of requisite diameter. |
| 181046 | Granular filters. |
| 181047 | Supply and fix penstock for washout pipe of 450 mm diameter. |
| 181048 | Supply and fix penstock for 600 mm x 600 mm opening. |
| 181049 | Supply and fix penstock for 750 mm x 750 mm opening. |
| 181050 | Duct plug for blank duct as shown in Drawing Nos. H2243 and H2244. |
| 181051 | Sealing for existing duct containing cables as shown in Drawing No. H2245, Diameter 50mm. |
| 181052 | Sealing for existing duct containing cables as shown in Drawing No. H2245, Diameter 80mm. |
| 181053 | Sealing for existing duct containing cables as shown in Drawing No. H2245, Diameter 100mm. |
| 181054 | Sealing for existing duct containing cables as shown in Drawing No. H2245, Diameter 150mm. |
| 182001 | Supply for temporary use Flashing battery lamps. |
| 182002 | Supply for temporary use Pressure lamps including fuel. |
| 182003 | Supply for temporary use A set of two standard traffic signals by day and two standard traffic signal lights by night, including use of existing barriers. |
| 182004 | Supply for temporary use Day watchmen/labourer to watch and maintain temporary road reinstatement as specified, complete with tools and materials to maintain reinstatement in good condition. |
| 182005 | Supply for temporary use Barricades and fencing to Drawing No. SK 3329/1, metal type. |
| 182006 | Supply for temporary use Pedestrian barrier plastic type. |
| 182007 | Supply for temporary use Water-filled barrier. |
| 182007a | Temporary Safety Barrier with Stipulated Containment Level according to Particular Specification Clause 12.04. |
| 182008 | Supply for temporary use Traffic warning cone, plastic, up to 1,000 mm height. |
| 182009 | Supply for temporary use Traffic warning signs, circular, up to 1,000 mm diameter. |
| 182010 | Supply for temporary use Traffic warning signs, triangular, up to 1,000 mm height. |
| 182011 | Supply for temporary use Traffic warning boards up to 1,600 mm x 1,200 mm. with letter and character as instructed by the Engineer. |
| 182012 | Supply for temporary use Flashing Arrow Sign mounted on vehicle. |
| 182013 | Supply for temporary use Flashing Arrow Sign mounted on trailer or supported frame. |
| 182014 | Extra over Item No. 182/012 for Truck Mounted Attenuator (TMA) |
| 183001 | Supply and drive timber piles of 150 mm minimum diameter up to 4.5 m long, including fixing rings, sharpening, setting in position, painting with two coats of bitumen, and cutting off heads. |
| 183002 | Supply and drive timber piles of 150 mm minimum diameter over 4.5 m and up to 6 m long, including fixing rings, sharpening, setting in position, painting with two coats of bitumen, and cutting off heads. |
| 183003 | Drive 150 mm diameter G.I. pipes as piles up to 4.5 m long, filled with Grade 20/40S concrete. Pipes provided by the Employer. |
| 183004 | Drive 150 mm diameter G.I. pipes as piles over 4.5 m and up to 7.5 m long, filled with Grade 20/40S concrete. Pipes provided by the Employer. |
| 183005 | Drive 80 mm - 100 mm diameter G.I. pipes as piles up to 4.5 m long, filled with Grade 20/40S concrete. Pipes provided by the Employer. |
| 183006 | As Item No. 183/005, but for pipes over 4.5 m and up to 7.5 m long. |
| 183007 | Weld 80 mm - 150 mm diameter G.I. pipes for extension of pile, per joint. |
| 183008 | Deliver, erect and remove piling frame and tackle for driving timber or G.I. pipes including all transportation and staging on site. |
| 183009 | As Item No. 183/008, but for hand driving. |
| 183010 | Supply and drive precast reinforced concrete piles, Grade 30/20S concrete including reinforcement, C.I. shoes, lifting eyes etc. Volume of pile supplied to be measured, no deduction for chamfers or tapered points. |
| 183011 | Cut off head of precast reinforce concrete pile to expose bars. |
| 183012 | Deliver, erect and remove piling frame and tackle for driving precast reinforced concrete piles including all transportation and staging on site. |
| 183013 | Establishment of piling plant for minipile. |
| 183014 | Moving piling plant for minipile. |
| 183015 | Minipile shaft, vertical, up to 300 mm diameter, depth: not exceeding 25 m. |
| 183016 | Minipile shaft, vertical, up to 300 mm diameter, depth: exceeding 25 m but not exceeding 45 m. |
| 183017 | Empty bores, vertical, up to 300 mm diameter minipile. |
| 183018 | Minipile shaft, raking, up to 300 mm diameter, depth: not exceeding 25 m. |
| 183019 | Minipile shaft, raking, up to 300 mm diameter, depth: exceeding 25 m but not exceeding 45 m. |
| 183020 | Empty bores, raking, up to 300 mm diameter minipile. |
| 183021 | Extra over Items Nos. 183/015 to 183/020 for permanent linings 6.3 mm thick for up to 300 mm diameter piles. |
| 183022 | Capping for pile heads. |
| 183023 | Establishment of piling plant for steel sheet piling. |
| 183024 | Supply steel sheet piling with min. section modulus 1360 cm3/m e. 5 m but n.e. 10 m in length. |
| 183025 | Supply steel sheet piling with min. section modulus 1360 cm3/m e. 10 m but n.e. 15 m in length. |
| 183026 | Drive steel sheet piling with min. section modulus 1360 cm3/m e. 5 m but n.e. 10 m in length. |
| 183027 | Drive steel sheet piling with min. section modulus 1360 cm3/m e. 10 m but n.e. 15 m in length. |
| 183028 | Cutting or burning off steel sheet piling with section min. modulus 1360 cm3/m. |
| 184001 | Fabrication of steelwork made up of mild steel rolled sections, plates, hollow sections and composite sections. |
| 184002 | Erection of steelwork made up of mild steel rolled sections, plates, hollow sections and composite sections. |
| 184003 | Fabrication of steelwork made up of grade 316 stainless steel rolled sections, plates, hollow sections and composite sections. |
| 184004 | Erection of steelwork made up of grade 316 stainless steel rolled sections, plates, hollow sections and composite sections. |
| 184005 | Galvanised or zinc spray coating (minimum average coating 305 g/ m2). |
| 184006 | Supply and fix anti-burglar grating and wire mesh screen as shown in Drawing No. WSD 2.6. |
| 184007 | Supply and fix aluminium alloy window frame, sashes and fittings as shown in Drawing No. WSD 2.5. |
| 184008 | Supply and fix glass louvres, ‘Naco’ or similar adjustable metal louvre frame including straightening glazing clips and adjusting as necessary but excluding glazing. |
| 184009 | Supply and fix stainless steel acoustic louvres, with stainless steel wire mesh:- 300 mm nominal thickness. |
| 184010 | Supply and fix stainless steel acoustic louvres, with stainless steel wire mesh:- 600 mm nominal thickness. |
| 184011 | Supply and fix stainless steel louvres, with stainless steel wire mesh as shown in Drawing No. WSD 2.9. |
| 184012 | Supply and fix stainless steel louvres, without stainless steel wire mesh as shown in Drawing No. WSD 2.9. |
| 184013 | Fix metal window frames and sashes but excluding glazing. |
| 184014 | Supply and fix fabricated steel doors and frames. |
| 184015 | Supply and fix fabricated stainless steel doors and frames. |
| 184016 | Supply and fix approved single-leaf fire resistance steel doors and frames, door opening not exceeding 2.1m(H) x 1m(W), 1-hour fire resistance period. |
| 184017 | Supply and fix approved single-leaf fire resistance steel doors and frames, door opening not exceeding 2.1m(H) x 1m(W), 2-hour fire resistance period. |
| 184018 | Supply and fix approved double-leaf fire resistance steel doors and frames, door opening not exceeding 2.1m(H) x 2.3m(W), 1-hour fire resistance period. |
| 184019 | Supply and fix approved double-leaf fire resistance steel doors and frames, door opening not exceeding 2.1m(H) x 2.3m(W), 2-hour fire resistance period. |
| 184019a | Supply and fix access door to 900 x 600 manhole opening as shown in Drawing No. WSD 3.22. |
| 184019b | Supply and fix access door to 900 x 600 manhole opening as shown in Drawing No. WSD 3.23. |
| 184020 | Supply and fix sundry metalwork including flooring, ladder, cover etc. with each item of weight up to 100 kg and made up of mild steel plates, channels, angles and rods. |
| 184021 | Supply and fix flooring, ladder, cover and the like each of weight up to 100 kg and made up of aluminium plates, channels, angles and rods. |
| 184021a | Supply and fix flooring, ladder, cover and the like each of weight up to 100 kg and made up of aluminium alloy plates, channels, angles and rods to BS 1470 as specified in GS19.09(1). |
| 184022 | Supply and fix flooring, ladder, cover and the like each of weight up to 100 kg and made up of stainless steel plates, channels, angles and rods. |
| 184023 | As item 184/020 but for weight exceeding 100 kg. |
| 184024 | As item 184/021 but for weight exceeding 100 kg. |
| 184024a | As item 184/021a but for weight exceeding 100 kg. |
| 184025 | As item 184/022 but for weight exceeding 100 kg. |
| 184027 | Supply and fix milled-lead sheet in accordance with B.S. 1178 : 1982 including all cutting, bending, drilling and provision of clamp bars, bolts etc. |
| 184028 | Supply and fix false ceiling system. |
| 184029 | Supply and fix steel bolts, hooks, eyes etc. |
| 184030 | As Item No. 184/029, but of brass. |
| 184030a | As Item No. 184/029, but of stainless steel. |
| 184031 | Fix step iron provided by the Employer in walls of manholes, valve chambers and buildings including all necessary breaking-in and grouting. |
| 184032 | Supply and fix cast iron step iron in walls of manholes, valve chambers or buildings including all necessary breaking-in and grouting. Step iron should be in accordance with Drawing No. WSD 7.8. |
| 184033 | Supply and fix stainless steel step iron 20 mm diameter and 400 mm wide in walls of manholes, valve chambers or buildings including all necessary breaking-in and grouting. Step iron should be in accordance with Drawing No. SK 20187/5. |
| 184034 | Fix cast iron or mild steel gratings, valve covers etc. weight up to 25 kg each. |
| 184035 | Fix cast iron or mild steel gratings, valve covers etc. weight exceeding 25 kg and not exceeding 50 kg each. |
| 184036 | Fix cast iron or mild steel gratings, valve covers etc. weight exceeding 50 kg each. |
| 184037 | Supply and install stainless steel grating 600 mm x 1300 mm as shown in Drawing no. SK 20187/8. |
| 184038 | Supply and install stainless steel grating 700 mm x 700 mm as shown in Drawing no. SK 20187/6. |
| 184039 | Supply and install stainless steel grating 950 mm x 2000 mm as shown in Drawing no. SK 20187/7. |
| 184040 | Supply and install stainless steel grating 1000 mm x 1000 mm as shown in Drawing no. SK 20187/6. |
| 184041 | Fix only fabricated steel work provided by the Employer made up of mild steel plates, channels, angles and rods including all drilling and welding but excluding machining. |
| 184042 | Fix only corrugated iron or plastic sheets provided by the Employer to roofs or walls. |
| 184043 | Fix aluminium rung ladder. |
| 184044 | Remove for reuse and refix cast iron/ductile iron valve covers, surface boxes, gratings, etc. weight up to 25 kg each. |
| 184045 | Remove for reuse and refix cast iron/ductile iron valve covers, surface boxes, gratings, etc. weight exceeding 25 kg and not exceeding 50 kg. |
| 184046 | Remove for reuse and refix cast iron/ductile iron valve covers, surface boxes, gratings, etc. weight exceeding 50 kg and not exceeding 100 kg. |
| 184047 | Remove for reuse and refix cast iron/ductile iron valve covers, surface boxes, gratings, etc. weight exceeding 100 kg. |
| 184048 | Remove existing fabricated metal work including unscrewing bolts, cutting rivets etc., lowering and removing and stacking. |
| 184049 | Remove existing corrugated iron or plastic sheets from roof or walls. |
| 184050 | Pick up and return to depots as directed by the Engineer cast iron/ductile iron valve covers, weight up to 25 kg each. |
| 184051 | Pick up and return to depots as directed by the Engineer cast iron/ductile iron valve covers, weight exceeding 25 kg and not exceeding 50 kg. |
| 184052 | Pick up and return to depots as directed by the Engineer cast iron/ductile iron valve covers, weight exceeding 50 kg and not exceeding 100 kg. |
| 184053 | Pick up and return to depots as directed by the Engineer cast iron/ductile iron valve covers, weight exceeding 100 kg. |
| 184054 | Sand blast surface with copper slag to remove rust. |
| 184055 | Sand blast surface for metal works excluding steel pipes with steel grits to remove rust. |
| 184056 | Supply and fix copper earthing electrode as shown in Drawing Nos. WSD 2.37 and 6.7. |
| 184057 | Supply and fix stainless steel vertical ladder without safety cage hoop, length not exceeding 5m as shown in Drawing Nos. WSD 7.2 or 7.3. |
| 184058 | Supply and fix stainless steel vertical ladder with safety cage hoop, length not exceeding 5m as shown in Drawing Nos. WSD 7.2 or 7.3. |
| 184059 | Supply and fix stainless steel vertical ladder with safety cage hoop, length exceeding 5m but not exceeding 10m as shown in Drawing Nos. WSD 7.2 or 7.3. |
| 184060 | Supply and fix 6mm diameter detachable stainless steel chain. |
| 184061 | Supply and fix cast iron grating, as shown in Drawing Nos. C2409, C2412 and C2413, on drainage channel of nominal size :- 225mm |
| 184062 | Supply and fix cast iron grating, as shown in Drawing Nos. C2409, C2412 and C2413, on drainage channel of nominal size :- 300mm |
| 184063 | Supply and fix cast iron grating, as shown in Drawing Nos. C2409, C2412 and C2413, on drainage channel of nominal size :- 375mm |
| 184064 | Supply and fix cast iron grating, as shown in Drawing Nos. C2409, C2412 and C2413, on drainage channel of nominal size :- 400mm |
| 184065 | Supply and fix stainless steel extension key type A for a total length not exceeding 2m with clamp type 1 as shown in Drawing No. WSD 7.7. |
| 184066 | Supply and fix stainless steel extension key type B for a total length not exceeding 2m with clamp type 1 as shown in Drawing No. WSD 7.7. |
| 184067 | Supply and fix stainless steel extension key type A for a total length not exceeding 2m with clamp type 2 as shown in Drawing No. WSD 7.7. |
| 184068 | Supply and fix stainless steel extension key type B for a total length not exceeding 2m with clamp type 2 as shown in Drawing No. WSD 7.7. |
| 184069 | Extra over Item Nos. 184/065 and 184/067 for stainless steel extension key type A for each additional metre or part thereof in excess of 2m, as shown in Drawing No. WSD 7.7. |
| 184070 | Extra over Item Nos. 184/066 and 184/068 for stainless steel extension key type B for each additional metre or part thereof in excess of 2m, as shown in Drawing No. WSD 7.7. |
| 184071 | Supply and fix stainless steel cage as shown in Drawing No WSD 3.4. |
| 185001 | Remove for re-use existing handrailing. |
| 185002 | Remove and dispose existing handrailing. |
| 185003 | Fix only G.I. or S.S. handrailing as shown in Drawing No. WSD7.6. |
| 185004 | Fix only G.I. or S.S. handrailing, without toe-plate as shown in Drawing No. WSD7.5. |
| 185005 | Fix only G.I. or S.S. handrailing, with toe-plate as shown in Drawing No. WSD7.5. |
| 185005a | Fix only 50 mm diameter G.I. tubular amenity railing as shown in Drawing No. H2135. |
| 185005b | Supply only 50 mm diameter G.I. tubular amenity railing as shown in Drawing No. H2135. |
| 185006 | Supply only 50 mm diameter G.I. tubular handrailing as shown in Drawing No.WSD7.6. |
| 185007 | Supply only 50 mm diameter stainless steel tubular handrailing as shown in Drawing No.WSD7.6. |
| 185008 | Supply only 40 mm diameter G.I. tubular handrailing, without toe-plate as shown in Drawing No.WSD7.5. |
| 185009 | Supply only 40 mm diameter G.I. tubular handrailing, with toe-plate as shown in Drawing No.WSD7.5. |
| 185010 | Supply only 40 mm diameter stainless steel tubular handrailing, without toe-plate as shown in Drawing No.WSD7.5. |
| 185011 | Supply only 40 mm diameter stainless steel tubular handrailing, with toe-plate as shown in Drawing No.WSD7.5. |
| 185012 | Supply and fix type I chain link fence as shown in Drawing No. WSD 6.1. |
| 185013 | Supply and fix type II chain link fence as shown in Drawing No. WSD 6.4. |
| 185014 | Supply only chain link mesh as shown in Drawing No. WSD 6.1, 6.2, 6.3, 6.4, 6.5 or 6.6. |
| 185015 | Supply only plastic fusion coated chain link mesh as shown in Drawing No. WSD 6.1, 6.2, 6.3, 6.4, 6.5 or 6.6. |
| 185016 | Fix only chain link mesh as shown in Drawing No. WSD 6.1, 6.2, 6.3, 6.4, 6.5 or 6.6. |
| 185017 | Fix only plastic fusion coated chain link mesh as shown in Drawing No. WSD 6.1, 6.2, 6.3, 6.4, 6.5 or 6.6. |
| 185018 | Supply only 2.5 mm diameter barbed wire including eye bolts etc. as shown in Drawing No. WSD 6.1, 6.2 or 6.3. |
| 185019 | Fix only 2.5 mm diameter barbed wire including eye bolts etc. as shown in Drawing No. WSD 6.1, 6.2 or 6.3. |
| 185020 | Supply main gate for Type I Chain Link Fence as shown in Drawing No. WSD 6.2. |
| 185021 | Supply side gate for Type I Chain Link Fence as shown in Drawing No. WSD 6.3. |
| 185022 | Supply main gate for Type II Chain Link Fence as shown in Drawing No. WSD 6.5. |
| 185023 | Supply side gate for Type II Chain Link Fence as shown in Drawing No. WSD 6.6. |
| 185024 | Fix main gate for Type I Chain Link Fence as shown in Drawing No. WSD 6.2. |
| 185025 | Fix side gate for Type I Chain Link Fence as shown in Drawing No. WSD 6.3. |
| 185026 | Fix main gate for Type II Chain Link Fence as shown in Drawing No. WSD 6.5. |
| 185027 | Fix side gate for Type II Chain Link Fence as shown in Drawing No. WSD 6.6. |
| 185028 | Remove for re-use of chain link fence. |
| 185029 | Supply and fix stainless steel sunflower barricade as shown in Drawing No. WSD 3.15. |
| 185029a | Supply and fix drop barrier gate as shown in Drawing No. WSD 5.9. |
| 185030 | Remove for re-use main gate of Type I chain link fence as shown in Drawing No. WSD 6.2. |
| 185031 | Remove for re-use side gate of Type I chain link fence as shown in Drawing No. WSD 6.3. |
| 185032 | Remove for re-use main gate of Type II chain link fence as shown in Drawing No. WSD 6.4. |
| 185033 | Remove for re-use side gate of Type II chain link fence as shown in Drawing No. WSD 6.6. |
| 185034 | Supply and fix Type I hoarding as shown in Drawing No. WSD 7.34. |
| 185035 | Supply and fix Type II hoarding as shown in Drawing No. WSD 7.35. |
| 185036 | Supply only expanded metal mesh as shown in Drawing Nos. WSD 6.10, 6.11, 6.12, 6.13, 6.14 and 6.15 or SK 60044/1 and 2. |
| 185037 | Fix only expanded metal mesh as shown in Drawing Nos. WSD 6.10, 6.11, 6.12, 6.13, 6.14 and 6.15 or SK 60044/1 and 2. |
| 185038 | Supply only lattice post as shown in Drawing No. WSD 6.10. |
| 185038a | Supply only lattice post as shown in Drawing No. WSD 6.13. |
| 185039 | Fix only lattice post as shown in Drawing No. WSD 6.10. |
| 185039a | Fix only lattice post as shown in Drawing No. WSD 6.13. |
| 185040 | Supply and fix high strength security fence as shown in Drawing No. WSD 6.10. (about 2.8 metre high) |
| 185040a | Supply and fix high strength security fence (3 metre high) as shown in Drawing No. WSD 6.13. |
| 185040b | Supply and fix high strength security fence (4.5 metre high) as shown in Drawing No. WSD A6.N16 (provisional). |
| 185041 | Supply and fix main gate for high strength security fence as shown in Drawing No. WSD 6.11. |
| 185041a | Supply and fix main gate for high strength security fence (3metre high) as shown in Drawing No. WSD 6.14 |
| 185041b | Supply and fix main gate for high strength security fence (4.5 metre high) as shown in Drawing No. WSD A6.N17 (provisional). |
| 185042 | Extra over item no.185/041 for each additional gate width. |
| 185042a | Extra over item no.185/041a for each additional gate width. |
| 185042b | Extra over item no.185/041b for each additional gate width. |
| 185043 | Supply and fix side gate for high strength security fence as shown in Drawing No. WSD 6.12. |
| 185043a | Supply and fix side gate for high strength security fence(3 metre high) as shown in Drawing No. WSD 6.15. |
| 185043b | Supply and fix side gate for high strength security fence (4.5 metre high) as shown in Drawing No. WSD A6.N18 (provisional). |
| 185044 | Remove and dispose existing high strength security fence. |
| 185045 | Remove for re-use of expanded metal mesh of high strength security fence. |
| 185046 | Remove for re-use lattice post of high strength security fence as shown in Drawing No. WSD 6.10. |
| 185046a | Remove for re-use lattice post of high strength security fence as shown in Drawing No. WSD 6.13. |
| 185046b | Remove for re-use lattice post of high strength security fence as shown in Drawing No. WSD A6.N16 (provisional). |
| 185047 | Remove for re-use main gate of high strength security fence as shown in Drawing No. WSD 6.11. |
| 185047a | Remove for re-use main gate of high strength security fence (3 metre high) as shown in Drawing No. WSD 6.14. |
| 185047b | Remove for re-use main gate of high strength security fence (4.5 metre high) as shown in Drawing No. WSD A6.N17 (provisional). |
| 185048 | Remove for re-use side gate of high strength security fence as shown in Drawing No. WSD 6.12. |
| 185048a | Remove for re-use side gate of high strength security fence (3 metre high) as shown in Drawing No. WSD 6.15. |
| 185048b | Remove for re-use side gate of high strength security fence (4.5 metre high) as shown in Drawing No. WSD A6.N18 (provisional). |
| 185049 | Supply and fix lockable gate for maintenance stairway as shown in Drawing No. C2508 or C2510. |
| 185049a | Supply and fix Razor Coil with Angel Web as per sketch SK20608/1 |
| 185050 | Extra over item nos. 185/012, 013, 020, 021, 022, 023, 034, 035, 036, 038, 040, 041, 042, 043 and 049a for stainless steel. |
| 185051 | Supply and fix galvanized steel untensioned corrugated beam barrier as shown in Highways Department's Standard Drawing Nos. H2112 to H2117, H2119 to H2129, straight and curved with radius exceeding 12m in radius. |
| 185052 | Supply and fix galvanized steel untensioned corrugated beam barrier as shown in Highways Department's Standard Drawing Nos. H2112 to H2117, H2119 to H2129, curved with radius not exceeding 12m in radius. |
| 185053 | Design and provision of hoarding to enhance site outlook at construction sites as specified in PS Clause 1.59. |
| 186001 | Establishment of cleaning facilities for tanks, clarifiers, pump sumps etc. |
| 186002 | Clean tanks, clarifiers, pump sumps etc. |
| 186003 | Supply and fix flexible curtain between compartments of service reservoirs as shown in Drawing No. WSD 3.19. |
| 186003a | Supply and fix air filter at ventilator of service reservoirs. |
| 186004 | Establishment of cleaning facilities at a distance up to 100 m from service reservoir. |
| 186005 | Extra over Item No. 186/004 for each additional 50 m or part thereof in excess of 100 m. |
| 186006 | Cleaning and sterilising fresh water service reservoir. |
| 186007 | Cleaning salt water service reservoir. |
| 186008 | Establishment of dechlorination plant at a distance up to 100 m from service reservoir. |
| 186009 | Extra over Item No. 186/008 for each additional 50 m or part thereof in excess of 100 m. |
| 186010 | Dechlorinating treatment of effluent from service reservoir. |
| 186011 | Establishment of mobile 'centrifuge and microfiltration plant' or equivalent mobile treatment plant at a distance up to 100 m from service reservoir. |
| 186012 | Extra over Item No. 186/011 for each additional 50 m or part thereof in excess of 100 m. |
| 186013 | Treatment of effluent/sludge from service reservoir by mobile 'centrifuge and microfiltration plant' or equivalent mobile treatment plant to meet Criteria A in the Particular Specifications. |
| 186014 | Treatment of effluent/sludge from service reservoir by mobile 'centrifuge and microfiltration plant' or equivalent mobile treatment plant to meet Criteria B in the Particular Specifications. |
| 186015 | Watertank, mobile, self-propelled up to 4,550 litres. |
| 186016 | Watertank, mobile, self-propelled over 4,550 litres and up to 6,820 litres. |
| 186017 | Establishment of pipeworks and pumping facilities to discharge water, filtrate, final effluent and the like from mobile 'centrifuge and microfiltration plant' or equivalent mobile treatment plant or temporary holding tank to service reservoir at distance up to 100 m from service reservoir. |
| 186018 | Extra over Item No. 186/017 for each additional 50 m or part thereof in excess of a distance of 100 m from service reservoir. |
| 187001 | Supply publicity board for trench works as shown in Drawing No. WSD 7.36. |
| 187002 | Fix publicity board for trench works as shown in Drawing No. WSD 7.36. |
| 187003 | Supply publicity board for motorist as shown in Drawing No. WSD 7.40. |
| 187004 | Fix publicity board for motorist as shown in Drawing No. WSD 7.40. |
| 187004a | Supply "No Entry" signboard for waterworks installation as shown in Drawing No. WSD 7.58. |
| 187004b | Fix "No Entry" signboard for waterworks installation as shown in Drawing No. WSD 7.58. |
| 187005 | Supply "No Entry" signboard as shown in Drawing No. WSD 5.10. |
| 187006 | Fix "No Entry" signboard as shown in Drawing No. WSD 5.10. |
| 187007 | Supply name board as shown in Drawing No. SK 3818/1. |
| 187008 | Fix name board as shown in Drawing No. SK 3818/1. |
| 187009 | Supply and fix portable signboard (1,220 mm x 800 mm) as shown in Drawing No. SK 2953/6. |
| 187010 | Supply and fix 160 mm x 160 mm x 3.0 mm thick plastic valve reference number plate as shown in Drawing No. SK 51000. |
| 187012 | Supply display board as shown in Drawing No. WSD 7.37. |
| 187013 | Fix display board as shown in Drawing No. WSD 7.37. |
| 187014 | Supply display board as shown in Drawing No. SK 3939/1 or SK 60005. |
| 187015 | Fix display board as shown in Drawing No. SK 3939/1 or SK 60005. |
| 187016 | Supply display board as shown in Drawing No. WSD 7.42. |
| 187017 | Supply "Private Road" signboard as shown in Drawing No. SK 3777/1. |
| 187018 | Fix "Private Road" signboard as shown in Drawing No. SK 3777/1. |
| 187019 | Supply "No Parking - Except with Permit" signboard as shown in Drawing No. SK 3777/2. |
| 187020 | Fix "No Parking - Except with Permit" signboard as shown in Drawing No. SK 3777/2. |
| 187021 | Supply "WSD Logo" signboard as shown in Drawing No. SK 3777/3. |
| 187022 | Fix "WSD Logo" signboard as shown in Drawing No. SK 3777/3. |
| 187023 | Supply "Water Gathering Ground" signboard as shown in Drawing No. SK 2855/2. |
| 187024 | Fix "Water Gathering Ground" signboard as shown in Drawing No. SK 2855/2. |
| 187025 | Supply "Warning - Stay Out of the Water" signboard as shown in Drawing No. W60020/1. |
| 187026 | Fix "Warning - Stay Out of the Water" signboard as shown in Drawing No. W60020/1. |
| 187027 | Supply "Drowning Blackspot" signboard as shown in Drawing No. W60020/2. |
| 187028 | Fix "Drowning Blackspot" signboard as shown in Drawing No. W60020/2. |
| 187029 | Supply "Warning - Do Not Enter" signboard as shown in Drawing No. W60020/3. |
| 187030 | Fix "Warning - Do Not Enter" signboard as shown in Drawing No. W60020/3. |
| 187031a | Supply "Danger - Do Not Enter" signboard as shown in Drawing No. W60020/4. |
| 187031b | Fix "Danger - Do Not Enter" signboard as shown in Drawing No. W60020/4. |
| 187032a | Supply "Warning - Mind Your Step" signboard as shown in Drawing No. W60020/5. |
| 187032b | Fix "Warning - Mind Your Step" signboard as shown in Drawing No. W60020/5. |
| 187033a | Supply "Warning - Beware of Falling" signboard as shown in Drawing No. W60020/6. |
| 187033b | Fix "Warning - Beware of Falling" signboard as shown in Drawing No. W60020/6. |
| 187034a | Supply "Warning - Flash Flooding" signboard as shown in Drawing No. W60020/7. |
| 187034b | Fix "Warning - Flash Flooding" signboard as shown in Drawing No. W60020/7. |
| 187035 | Supply wall mounted stainless steel warning board as shown in Drawing No. SK 20187/1. |
| 187036 | Fix wall mounted warning board as shown in Drawing No. SK 20187/1. |
| 187037 | Supply stainless steel warning board with bracket, post and accessaries as shown in Drawing No. SK 20187/2. |
| 187038 | Fix warning board as shown in Drawing No. SK 20187/2 complete with footing. |
| 187039 | Fix display board as shown in Drawing No. WSD 7.42. |
| 187040 | Supply sign plate, 3 mm thick, self mounting on slope type as shown in Drawing Nos. SK 60064/1 to SK 60064/4. |
| 187041 | Fix sign plate, 3mm thick, self-mounting on vegetated slopes as shown in Drawing Nos. SK 60064/1 to SK 60064/4. |
| 187042 | Fix sign plate, 3mm thick, self-mounting on hard surface slopes as shown in Drawing Nos. SK 60064/1 to SK 60064/4. |
| 187043 | Remove sign plate, 3mm thick, self-mounting on slope type, as shown in Drawing Nos. SK 60064/1 to SK 60064/4. |
| 187044 | Remove sign plate, 3mm thick or 6 mm thick, self-mounting on slope type, as shown in Drawing Nos. SK 60064/1 to SK 60064/4. |
| 187045 | Fix sign plate, 3 mm thick, self mounting on slope type, as shown in Drawing Nos. SK 60064/1 to SK 60064/4. |
| 187046 | Supply sign plate, 3 mm thick, mounting on wall type, complete with accessories as shown in Drawing Nos. SK 60064/1 to SK 60064/4. |
| 187047 | Remove sign plate, 3mm thick, mounting on wall type, as shown in Drawing Nos. SK 60064/1 to SK 60064/4. |
| 187048 | Remove sign plate, 3mm thick or 6 mm thick, mounting on wall type, as shown in Drawing Nos. SK 60064/1 to SK 60064/4. |
| 187049 | Fix sign plate, 3 mm thick, mounting on wall type, as shown in Drawing Nos. SK60064/1 to SK 60064/4. |
| 187050 | Supply portable publicity board as shown in Drawing No. SK 60007. |
| 187051 | Fix portable publicity board as shown in Drawing No. SK 60007. |
| 187052 | Supply stainless steel board, 3mm thick, inscribed with letters and characters as instructed. |
| 187053 | Fix stainless steel board supplied under Item No. 187/052, mounting on wall type at height not exceeding 3m, as shown in Drawing Nos. SK60064/1 to SK 60064/4 complete with stainless steel accessories. |
| 187054 | Extra over Item No. 187/053, for mounting on stainless steel frame complete with footing. |
| 187055 | Warning signboard for feature pending upgrading as shown in Sketch R2008114 |
| 187056 | Supply "Warning - No Fishing Without A Valid Fishing Licence" signboard as shown in Drawing No. SK60077/001. |
| 187057 | Fix "Warning - No Fishing Without A Valid Fishing Licence" signboard as shown in Drawing No. SK60077/001. |
| 187058 | Supply "Warning - No Fishing" signboard as shown in Drawing No. SK60077/002. |
| 187059 | Fix "Warning - No Fishing" signboard as shown in Drawing No. SK60077/002. |
| 188001 | Baffle Wall Type 1 baffle wall |
| 188002 | Baffle Wall Type 2 baffle wall |
| 188003 | Supply glass reinforced plastics (GRP) panel – solid type |
| 188004 | Supply glass reinforced plastics (GRP) panel – open mesh type |
| 188005 | Install and fix GRP panels to the supporting frame solid type |
| 188006 | Install and fix GRP panels to the supporting frame – open mesh type |
| 188007 | Supply and install structural support frame and the associated footing for catchwater width not exceeding 3m |
| 188008 | Supply and install structural support frame and the associated footing for catchwater width between 3m and 4m but not exceeding 4m |
| 188009 | Supply and install structural support frame and the associated footing for catchwater width between 4m and 5m but not exceeding 5m |
| 190001A | Ordinary glazing quality British sheet glass of 2 mm thick. Panes up to 0.2 m2 |
| 190001B | Ordinary glazing quality British sheet glass of 2 mm thick. Panes ex. 0.2 m2 and not ex. 0.4 m2 |
| 190001C | Ordinary glazing quality British sheet glass of 2 mm thick. Panes exceeding 0.4 m2 |
| 190002A | As Item No. 190/001, but of 2.5 mm thick. Panes up to 0.2 m2 |
| 190002B | As Item No. 190/001, but of 2.5 mm thick. Panes ex. 0.2 m2 and not ex. 0.4 m2 |
| 190002C | As Item No. 190/001, but of 2.5 mm thick. Panes exceeding 0.4 m2 |
| 190003A | As Item No. 190/001, but of 3 mm thick. Panes up to 0.2 m2 |
| 190003B | As Item No. 190/001, but of 3 mm thick. Panes ex. 0.2 m2 and not ex. 0.4 m2 |
| 190003C | As Item No. 190/001, but of 3 mm thick. Panes exceeding 0.4 m2 |
| 190004A | As Item No. 190/001, but of 4 mm thick. Panes up to 0.2 m2 |
| 190004B | As Item No. 190/001, but of 4 mm thick. Panes ex. 0.2 m2 and not ex. 0.4 m2 |
| 190004C | As Item No. 190/001, but of 4 mm thick. Panes exceeding 0.4 m2 |
| 190005A | As Item No. 190/001, but of 6 mm thick. Panes up to 0.2 m2 |
| 190005B | As Item No. 190/001, but of 6 mm thick. Panes ex. 0.2 m2 and not ex. 0.4 m2 |
| 190005C | As Item No. 190/001, but of 6 mm thick. Panes exceeding 0.4 m2 |
| 190006A | As Item No. 190/001, but white obscured glass 3 mm thick in hammered, cathedral or other similar pattern. Panes up to 0.2 m2 |
| 190006B | As Item No. 190/001, but white obscured glass 3 mm thick in hammered, cathedral or other similar pattern. Panes ex. 0.2 m2 and not ex. 0.4 m2 |
| 190006C | As Item No. 190/001, but white obscured glass 3 mm thick in hammered, cathedral or other similar pattern. Panes exceeding 0.4 m2 |
| 190007A | As Item No. 190/001, but hexagon wired, rough cast glass. Panes up to 0.2 m2 |
| 190007B | As Item No. 190/001, but hexagon wired, rough cast glass. Panes ex. 0.2 m2 and not ex. 0.4 m2 |
| 190007C | As Item No. 190/001, but hexagon wired, rough cast glass. Panes exceeding 0.4 m2 |
| 190008A | As Item No. 190/001, but square wired float glass. Panes up to 0.2 m2 |
| 190008B | As Item No. 190/001, but square wired float glass. Panes ex. 0.2 m2 and not ex. 0.4 m2 |
| 190008C | As Item No. 190/001, but square wired float glass. Panes exceeding 0.4 m2 |
| 190009A | As Item No. 190/001, but reeded glass of 3 mm thick. Panes up to 0.2 m2 |
| 190009B | As Item No. 190/001, but reeded glass of 3 mm thick. Panes ex. 0.2 m2 and not ex. 0.4 m2 |
| 190009C | As Item No. 190/001, but reeded glass of 3 mm thick. Panes exceeding 0.4 m2 |
| 190010A | As Item No. 190/001, but reeded glass of 5 mm thick. Panes up to 0.2 m2 |
| 190010B | As Item No. 190/001, but reeded glass of 5 mm thick. Panes ex. 0.2 m2 and not ex. 0.4 m2 |
| 190010C | As Item No. 190/001, but reeded glass of 5 mm thick. Panes exceeding 0.4 m2 |
| 190011 | Extra over Item Nos. 190/001 to 190/005 for equivalent plastic sheet. |
| 190012 | "Silvering quality" 6 mm thick polished plate, mirror glass, silver backed and painted with two coats copal varnish after silvering fixing with chromium plated clips screwed to backing or to wall as required. |
| 190013 | Remove existing windows and prepare surround for refixing. |
| 190014 | Secure glazing in window sashes. |
| 190015A | Remove old glass or plastic sheets, etc. Panes up to 0.2 m2 |
| 190015B | Remove old glass or plastic sheets, etc. Panes ex. 0.2 m2 and not ex. 0.4 m2 |
| 190015C | Remove old glass or plastic sheets, etc. Panes exceeding 0.4 m2 |
| 200001 | Saloon car (5 seater). |
| 200002 | Four wheel drive jeep (7 seater). |
| 200002a | Electric vehicle (5 seater). |
| 200002b | Electric vehicle (7 seater). |
| 200003 | Multi-purpose wagon (8 seater). |
| 200003a | Multi-purpose goods van (5 seater). |
| 200004 | Passenger Van (16 seater). |
| 200004a | Crew Van (6 seater) |
| 200005 | Operate and maintain saloon car (5 seater). |
| 200006 | Operate and maintain four wheel drive jeep (7 seater). |
| 200006a | Operate and maintain electric vehicle (5 seater). |
| 200006b | Operate and maintain electric vehicle (7 seater). |
| 200007 | Operate and maintain multi-purpose wagon (8 seater). |
| 200007a | Operate and maintain multi-purpose goods van (5 seater). |
| 200008 | Operate and maintain van (16 seater). |
| 200008a | Operate and maintain crew van for day shift (6 seater). |
| 200008b | Operate and maintain crew van for night shift (6 seater). |
| 200009 | Overtime for saloon car (5 seater). |
| 200010 | Overtime for four wheel drive jeep (7 seater). |
| 200010a | Overtime for electric vehicle (5 seater). |
| 200010b | Overtime for electric vehicle (7 seater). |
| 200011 | Overtime for multi-purpose wagon (8 seater). |
| 200011a | Overtime for multi-purpose goods van (5 seater). |
| 200012 | Overtime for passenger van (16 seater). |
| 200012a | Overtime for crew van for day shift (6 seater). |
| 200012b | Overtime for crew van for night shift (6 seater). |
| 200013 | Extra over Item No. 200/005 and 200/006, 200/006a and 200/006b for crossing habour tunnel. |
| 200014 | Extra over Item Nos. 200/007 and 007a for crossing habour tunnel. |
| 200015 | Extra over Item No. 200/008 , 008a and 008b for crossing habour tunnel. |
| 200016 | (Not used) Extra over Item No. 200/005 and 200/006 for crossing Lantau Link. |
| 200017 | (Not used) Extra over Item Nos. 200/007 and 007a for crossing Lantau Link. |
| 200018 | (Not used) Extra over Item No. 200/008 for crossing Lantau Link. |
| 200019 | Motor boat. |
| 200020 | Operate and maintain motor boat. |
| 200021 | Overtime for motor boat. |
| 200022 | Water wagon. |
| 200023 | Operate and maintain water wagon. |
| 200024 | Extra over Item 200/023 for operating and manning water wagon for providing temporary water supply to customers within normal working hours with departure of water wagon for the designated locations made within 15 minutes of receiving the order from the Engineer or the Engineer's Representative. |
| 200025 | Extra over Item 200/023 for operating and manning water wagon for providing temporary water supply to customers outside normal working hours with departure of water wagon for the designated locations made within 15 minutes of receiving the order from the Engineer or the Engineer's Representative. |
| 200025a | Extra over Item 200/023 for operating and manning water wagon for providing temporary water supply to customers within normal working hours with departure of water wagon for the designated locations made in more than 15 minutes of receiving the order from the Engineer or the Engineer’s Representative. |
| 200025b | Extra over Item 200/023 for operating and manning water wagon for providing temporary water supply to customers outside normal working hours with departure of water wagon for the designated locations made in more than 15 minutes of receiving the order from the Engineer or the Engineer’s Representative. |
| 200026 | Extra over Item No. 200/023 for crossing harbour tunnels. |
| 200027 | (Not used) Extra over Item No. 200/023 for crossing Lantau Link. |
| 200028 | Provision of water tanks. |
| 200028a | Maintenance of water tanks. |
| 200029 | Crane lorries, with gross vehicle weight below 24 tonnes, mobilised to collect water tanks for provision of emergency temporary fresh water supply to customers. |
| 200029a | Crane lorries, with gross vehicle weight 24 tonnes or above, mobilised to collect water tanks for provision of emergency temporary fresh water supply to customers. |
| 200029b | Extra over Item No. 200/029 for mobilisation of crane lorries to collect water tanks during General Holidays excluding Lunar New Year Holidays. |
| 200029c | Extra over Item No. 200/029a for mobilisation of crane lorries to collect water tanks during General Holidays excluding Lunar New Year Holidays. |
| 200029d | Extra over Item No. 200/029 for mobilisation of crane lorries to collect water tanks during Lunar New Year Holidays. |
| 200029e | Extra over Item No. 200/029a for mobilisation of crane lorries to collect water tanks during Lunar New Year Holidays. |
| 200029f | Extra over Item No. 200/029 for arrival of mobilised crane lorries to collect water tanks not exceeding 30 minutes of receiving the order from the Engineer. |
| 200029g | Extra over Item No. 200/029a for arrival of mobilised crane lorries to collect water tanks not exceeding 30 minutes of receiving the order from the Engineer. |
| 200029h | Extra over Item No. 200/029 for arrival of mobilised crane lorries to collect water tanks exceeding 30 minutes but not exceeding 1 hour of receiving the order from the Engineer. |
| 200029i | Extra over Item No. 200/029a for arrival of mobilised crane lorries to collect water tanks exceeding 30 minutes but not exceeding 1 hour of receiving the order from the Engineer. |
| 200029j | Extra over Item No. 200/029 for arrival of mobilised crane lorries to collect water tanks exceeding 1 hour but not exceeding 2 hours of receiving the order from the Engineer. |
| 200029k | Extra over Item No. 200/029a for arrival of mobilised crane lorries to collect water tanks exceeding 1 hour but not exceeding 2 hours of receiving the order from the Engineer. |
| 200029l | Operate and maintain water tanks set up at destinations specified by the Engineer for provision of emergency temporary fresh water supply to customers. |
| 200029m | Extra over Item No. 200/029l for crane lorry crossing harbour tunnels, with gross vehicle weight below 24 tonnes. |
| 200029n | Extra over Item No. 200/029l for crane lorry crossing harbour tunnels, with gross vehicle weight 24 tonnes or above. |
| 200029o | (Not used) Extra over Item No. 200/029l for crane lorry crossing Lantau Link, with gross vehicle weight below 24 tonnes. |
| 200029p | (Not used) Extra over Item No. 200/029l for crane lorry crossing Lantau Link, with gross vehicle weight 24 tonnes or above. |
| 200029q | Extra over Item No. 200/029 for provision and maintenance of cargo vessel with cranes of licensed engine up to 300 hp. |
| 200033b | Facilities to Field Officer |
| 200038 | Complete site management plan for trip ticket system. |
| 200039 | Implementation of site management plan for trip ticket system. |
| 200040 | Set of progress photographs. |
| 200041 | Provision of 5G mobile telephone. |
| 200041a | Provision of 5G mobile tablet. |
| 200042 | Maintenance of 5G mobile smartphone. |
| 200042a | Maintenance of 5G mobile tablet. |
| 200043 | Provision of SIM card with telecommunication services (vocie calls usage n.e. 1500 minutes, video calls usage not exceeding 50 minutes, unlimited mobile 5G Internet access, unlimited intra-network SMS and inter-network SMS usage not exceeding 15 nos. per device per month) |
| 200044 | Extra over Item No. 200/043 for each additional 500 minutes non video calls usage or part thereof in excess of 1500 minutes non video calls per telephone per month. |
| 200045 | Extra over Item No. 200/043 for each additional 50 minutes video calls usage or part thereof in excess of 50 minutes video calls per telephone per month. |
| 200046 | Submission of record photographs in association with completion notice submission of excavation permit in Excavation Permit Management System. |
| 200047 | Provision of intermediate bulk container |
| 200048 | Provision of small container |
| 200049 | Maintenance of intermediate bulk container |
| 200050 | Maintenance of small container |
| 200051 | Delivery of 0.05 m3 sodium hypochlorite solution to Tai O Water Treatment Works by stair climbing robot or other approved lifting methods |
| 200052 | Conduct Point Cloud Survey for all exposed water mains in a circular area not exceeding 20m in diameter |
| 200053 | Conduct Point Cloud Survey for service reservoirs with an internal area at floor level not exceeding 1,000 m2 |
| 200054 | Extra over Item No. 200/052 for each additional 10m or part thereof in excess of 20m in diameter |
| 200055 | Extra over Item No. 200/053 for each additional area of 100 m2 or part thereof in excess of 1,000 m2 |
| 200056 | Conduct GPS Survey to record Easting (m) and Northing (m) of the centre points of 5,000 valve pits / covers / water meters according to PS Clause 1.71 |
| 200057 | Conduct additional GPS Survey to record Easting (m) and Northing (m) of the centre point of a valve pit / cover / water meters after satisfactory completion of item no. 200/056 |
| 200058 | Provision of leakage detection survey equipment for Engineer’s staff or his representatives |
| 200059 | Maintenance of leakage detection survey equipment for Engineer’s staff or his representatives |
| 210001 | Labourer (unskilled)/Tradesman's Labourer. |
| 210002 | Labourer (water wagon) |
| 210003 | Excavator. |
| 210005 | Working ganger. |
| 210006 | Concretor. |
| 210007 | Bricklayer. |
| 210008 | Drainlayer. |
| 210009 | Mason, rubble, splitting or ashlar. |
| 210010 | Steel bender/fixer. |
| 210011 | Blacksmith. |
| 210012 | Carpenter and joiner. |
| 210013 | Plumber (including skilled labourer for valve packing). |
| 210014 | Sewerman |
| 210015 | Mainslayer and jointer (including PE pipe layer and jointer). |
| 210016 | Fitter (including Mechanical Fitter). |
| 210017 | Welder. |
| 210018 | Plasterer. |
| 210019 | Terrazzo or granolithic worker. |
| 210020 | Glazier. |
| 210021 | Painter. |
| 210022 | Electrician (Wireman). |
| 210023 | Plant operator. |
| 210024 | Truck driver. |
| 210025 | Forklift truck driver |
| 210026 | Heavy load coolie |
| 210027 | Pneumatic driller. |
| 210028 | Bamboo worker and scaffolder. |
| 210029 | Structural steel erector. |
| 210030 | Diver. |
| 210031 | Diver's linesman. |
| 210032 | Watchman. |
| 210033 | Valve operator. |
| 210034 | Rigger. |
| 210035 | Arborist |
| 210035 | Skilled landscape worker |
| 210036 | Tree Worker |
| 210037 | Tree Worker - Aerial |
| 210038 | Tree Climber |
| 215001 | Reconnaissance survey of water mains |
| 215002 | Detailed survey of water mains |
| 215003 | Inspection of leakage collection manholes as specified in PS Clause 45.02. |
| 215005 | Water Treatment Works Routine Works Team, shift 1 with working hours between 08:00 and 16:00 |
| 215005a | Provision of team leader, shift 1 with working hours between 08:00 and 16:00 |
| 215005b | Provision of worker, shift 1 with working hours between 08:00 and 16:00 |
| 215006 | Water Treatment Works Routine Works Team, shift 2 with working hours between 16:00 and 24:00 |
| 215006a | Provision of team leader, shift 2 with working hours between 16:00 and 24:00 |
| 215006b | Provision of worker, shift 2 with working hours between 16:00 and 24:00 |
| 215007 | Water Treatment Works Routine Works Team, shift 3 with working hours between 24:00 and 08:00 |
| 215007a | Provision of team leader, shift 3 with working hours between 24:00 and 08:00 |
| 215007b | Provision of worker, shift 3 with working hours between 24:00 and 08:00 |
| 215008 | Extra over Item No. 215/005, 215/005a, 215/005b for provision of each crane operator or each fork-lift truck operator for the Water Treatment Works Routine Works Team as specified in Clause 45.04.1(5)(3) of the Particular Specification, shift 1 with working hours between 08:00 to 16:00. |
| 215009 | Extra over Item No. 215/006, 215/006a, 215/006b for provision of each crane operator or each fork-lift truck operator for the Water Treatment Works Routine Works Team as specified in Clause 45.04.1(5)(3) of the Particular Specification, shift 2 with working hours between 16:00 to 24:00. |
| 215010 | Extra over Item No. 215/007, 215/007a, 215/007b for provision of each crane operator or each fork-lift truck operator for the Water Treatment Works Routine Works Team as specified in Clause 45.04.1(5)(3) of the Particular Specification, shift 3 with working hours between 24:00 to 08:00. |
| 215010a | Extra over Item No. 215/005, 215/005a, 215/005b for provision of each worker for the Water Treatment Works Routine Works Team as specified in Clause 45.04.1(4)(3) of the Particular Specification, shift 1 with working hours between 08:00 to 16:00. |
| 215010b | Extra over Item No. 215/006, 215/006a, 215/006bfor provision of each worker for the Water Treatment Works Routine Works Team as specified in Clause 45.04.1(4)(3) of the Particular Specification, shift 2 with working hours between 16:00 to 24:00. |
| 215010c | Extra over Item No. 215/007, 215/007a, 215/007b for provision of each worker for the Water Treatment Works Routine Works Team as specified in Clause 45.04.1(4)(3) of the Particular Specification, shift 3 with working hours between 24:00 to 08:00. |
| 215011 | Pumping Station Routine Works Team |
| 215011a | Extra over Item No. 215/011, 215/011c, 215/011d for provision of each worker for the Pumping Station Routine Works Team as specified in Clause 45.05.1(4)(3) of the Particular Specification. |
| 215011b | Extra over Item No. 215/011, 215/011c, 215/011d for provision of each crane operator for the Pumping Station Routine Works Team as specified in Clause 45.05.1(5)(2A) of the Particular Specification. |
| 215011c | Provision of team leader |
| 215011d | Provision of worker |
| 215012 | Distribution system maintenance team, shift 1 with working hours between 08:00 to 18:00 as specified in PS Clause |
| 215013 | Distribution system maintenance team, shift 2 with working hours between 18:00 to 08:00 as specified in PS Clause |
| 215014 | Competent Person and necessary equipment for confined space. |
| 215015 | Laboratory Attendant, shift 1 with working hours between 08:00 and 16:00 in PS Clause 45.03. |
| 215016 | Laboratory Attendant, shift 2 with working hours between 16:00 and 24:00 in PS Clause 45.03.. |
| 215017 | Laboratory Attendant, shift 3 with working hours between 24:00 and 08:00 in PS Clause 45.03.. |
| 215018 | Reservoir Attendant, shift 1 with working hours between 08:00 and 20:00 as specified in PS Clause 45.07. |
| 215019 | Reservoir Attendant, shift 2 with working hours between 20:00 and 08:00 as specified in PS Clause 45.07. |
| 215020 | Sounding and Visual Inspection of a valve (in a batch not exceeding 150 numbers of valves in a prescribed area), submission of the corresponding Sounding and Visual Inspection Report, in accordance with the Particular Specification Section 45.08. |
| 215021 | Extra over item no. 215/020 for each additional valve in excess of 150 numbers. |
| 215022 | Waterworks Facilities Surveillance Team, shift 1 with working hours between 08:00 and 16:00 as specified in PS Clause 45.09 |
| 215023 | Waterworks Facilities Surveillance Team, shift 2 with working hours between 16:00 and 24:00 as specified in PS Clause 45.09 |
| 215024 | General Cleaning and Environmental Hygiene Control Team as specified in PS Clause 45.11 |
| 220001 | Air compressor (silenced type), up to 4.0 m3/min. |
| 220002 | Air compressor (silenced type), over 4.0 m3/min and up to 8.0 m3/min. |
| 220003 | Air compressor (silenced type), over 8.0 m3/min and up to 12.0 m3/min. |
| 220004 | Air compressor (silenced type), over 12.0 m3/min and up to 20.0 m3/min. |
| 220005 | Pneumatic tool (concrete breaker, drill etc.) including hoses, steels, picks, spades etc. |
| 220006 | Pneumatic paint hammer scraper tool including hoses. |
| 220007 | Hydraulic hand breaker, complete set. |
| 220008 | Air blowers for ventilation, 1 kW. |
| 220011 | Motor lorry, plated gross vehicle weight up to 6.5 t. |
| 220012 | Motor lorry, plated gross vehicle weight over 6.5 t and up to 7.5 t. |
| 220013 | Motor lorry, plated gross vehicle weight over 7.5 t and up to 12 t. |
| 220014 | Motor lorry, plated gross vehicle weight over 12 t and up to 14 t. |
| 220015 | Motor lorry, plated gross vehicle weight over 14 t and up to 17 t. |
| 220016 | Motor lorry, plated gross vehicle weight over 17 t and up to 24.5 t. |
| 220017 | Motor lorry, plated gross vehicle weight over 24.5 t and up to 30 t. |
| 220018 | Extra over Item Nos. 220/011 to 220/017 for motor lorry fitted with crane, maximum safe working load up to 3.5 t. |
| 220019 | Ditto, but for motor lorry fitted with crane, maximum safe working load up to 7.5 t. |
| 220020 | Ditto, but for motor lorry fitted with crane, maximum safe working load up to 12 t. |
| 220021 | Ditto, but for motor lorry fitted with crane, maximum safe working load up to 17 t. |
| 220022 | Ditto, but for motor lorry fitted with crane, maximum safe working load up to 22 t. |
| 220027 | Tipper lorry, plated gross vehicle weight up to 11 t. |
| 220028 | Tipper Lorry, plated gross vehicle weight over 11 t and up to 17 t. |
| 220029 | Water pump, portable, discharge pipe diameter up to 51 mm including hoses and operator. |
| 220030 | Water pump, portable, discharge pipe diameter but over 51 mm and up to 76 mm including hoses and operator. |
| 220031 | Water pump, portable, discharge pipe diameter over 76 mm and up to 102 mm including hoses and operator. |
| 220032 | Water pump, portable, discharge pipe diameter over 102 mm and up to 152 mm including hoses and operator. |
| 220033 | Water pump, submersible, discharge pipe diameter up to 51 mm, including hoses and operator. |
| 220034 | Water pump, submersible, discharge pipe diameter over 51 mm and up to 76 mm including hoses and operator. |
| 220035 | Water pump, submersible, discharge pipe diameter over 76 mm and up to 102 mm including hoses and operator. |
| 220036 | Water pump, submersible, discharge pipe diameter over 102 mm and up to 152 mm including hoses and operator. |
| 220037 | Sludge pump, submersible, discharge pipe diameter up to 76 mm, including hoses and operator. |
| 220038 | Sludge pump, submersible, discharge pipe diameter over 76 mm and up to 102 mm including hoses and operator. |
| 220039 | Sludge pump, submersible, discharge pipe diameter over 102 mm and up to 152 mm including hoses and operator. |
| 220040 | Water pump, portable, to test pipelines up to 250 m head. |
| 220041 | Grout pump (electric), max. output up to 310 litres/min. |
| 220042 | Grout pump (electric), hand operated and maximum output up to 25 litres/min. |
| 220043 | Road roller, over 5 t and up to 8 t. |
| 220044 | Road roller, over 8 t and up to 10 t. |
| 220046 | Crane, mobile road type, maximum working load up to 8.5 t. |
| 220047 | Crane, mobile road type, maximum working load over 8.5 t and up to 12.5 t. |
| 220048 | Crane, mobile road type, maximum working load over 12.5 t and up to 20 t. |
| 220049 | Crane, mobile road type, maximum working load over 20 t and up to 35 t. |
| 220050 | Crane, mobile road type, maximum working load over 35 t and up to 50 t. |
| 220051 | Concrete mixer, up to 300 litres capacity. |
| 220052 | Concrete mixer, capacity over 300 litres and up to 400 litres. |
| 220053 | Grout mixer, roller type, maximum output up to 10 litres/min. |
| 220054 | Grout mixer, roller type, maximum output over 10 litres/min. and up to 22 litres/min. |
| 220055 | Concrete vibrator, poker type, including prime mover (diesel driven). |
| 220056 | Concrete vibrator, poker type, including prime mover (electric driven). |
| 220057 | Concrete vibrator, poker type, including prime mover (air driven). |
| 220058 | Portable electric welding set, 300/480 amps, including cables and welding shields but excluding electrodes. |
| 220059 | Power rammer or vibration rammer. |
| 220060 | Bulldozer, up to 70 kW (Flywheel). |
| 220061 | Bulldozer, over 70 kW and up to 85 kW. |
| 220062 | Bulldozer, over 85 kW and up to 115 kW. |
| 220063 | Bulldozer, over 115 kW and up to 135 kW. |
| 220064 | Bulldozer, over 135 kW and up to 185 kW. |
| 220065 | Bulldozer, over 185 kW. |
| 220066 | Excavator and dragline, rated capacity 0.8 m3. |
| 220067 | Tractor shovel, rated capacity up to 1.0 m3. |
| 220068 | Tractor shovel, rated capacity over 1.0 m3 and up to 1.2 m3. |
| 220069 | Tractor shovel, rated capacity over 1.2 m3 and up to 1.4 m3. |
| 220070 | Generator set, diesel or gasoline engine-driven, output power up to 10 kVA. |
| 220071 | Generator set, diesel or gasoline engine-driven, output power over 10 kVA and up to 16 kVA. |
| 220072 | Generator set, diesel or gasoline engine-driven, output power over 16 kVA and up to 30 kVA. |
| 220073 | Generator set, diesel or gasoline engine-driven, output power over 30 kVA and up to 50 kVA. |
| 220074 | Generator set, diesel or gasoline engine-driven, output power over 50 kVA and up to 70 kVA. |
| 220075 | Generator set, diesel or gasoline engine-driven, output power over 70 kVA and up to 100 kVA. |
| 220076 | Generator set, diesel or gasoline engine-driven, output power over 100 kVA and up to 150 kVA. |
| 220077 | Backhoe excavator, rated capacity up to 0.6 m3. |
| 220078 | Backhoe excavator, rated capacity over 0.6 m3 and up to 1.0 m3. |
| 220079 | Oxy-acetylene cutter, complete with cylinders of gases, hoses, shield etc. |
| 220080 | Bitumen thermometer. |
| 220081 | Expandite melter pourer or equivalent. |
| 220082 | Road hazard warning lantern (battery operated). |
| 220083 | Road hazard warning lantern (electrically operated, generator to be paid separately). |
| 220084 | Lamp-Hurricane. |
| 220085 | Pressure lamp. |
| 220086 | Spotlight, 250 watts with connection cable and stand (generator to be paid separately). |
| 220087 | Traffic signals (set), excluding generator but including mains power. |
| 220088 | Junk or lighter with crew. |
| 220089 | Motor launch with crew up to 6 m in length. |
| 220090 | Motor launch with crew exceeding 6 m but not exceeding 8 m in length. |
| 220091 | Van with driver. |
| 220092 | 5 passenger seats under 5.5 tonne box-typed light goods vehicle with driver (fitted with flashing roof light bar and alternate red and yellow fluorescent and reflectorised rear markings). |
| 220093 | Self-propelled high pressure water jetting unit, minimum water pressure of 300 bars, minimum flow rate 50 litres/minute including all necessary equipment for cleaning water mains and drains. |
| 220094 | Container-type office. |
| 220095 | Telephone socket and electrical equipment for use in container-type office. |
| 220096 | Barge boat with crew and equipped with mechanical crane or hydraulic jack. |
| 220097 | Diver's real time video camera and display monitor for underwater inspection shooting. |
| 220098 | Electric valve actuator (generator to be paid separately). |
| 220099 | Truck mounted aerial working platform with effective working height up to 30m. |
| 230001 | Supply and fix copper pipes, 15 mm outside diameter. |
| 230002 | Supply and fix copper pipes, 22 mm outside diameter. |
| 230003 | Supply and fix copper pipes, 28 mm outside diameter. |
| 230004 | Supply and fix copper pipes, 42 mm outside diameter. |
| 230005 | Supply and fix copper pipes, 54 mm outside diameter. |
| 230006 | Supply and fix copper pipes, 76 mm outside diameter. |
| 230007 | Supply and fix copper pipes, 108 mm outside diameter. |
| 230008 | Supply and fix copper pipes, 159 mm outside diameter. |
| 230009 | Exta over Item No. 230/003 for U.P.V.C. sleeve. |
| 230010 | Exta over Item No. 230/004 for U.P.V.C. sleeve. |
| 230011 | Extra over Item No. 230/001 for valves and stopcocks. |
| 230012 | Extra over Item No. 230/002 for valves and stopcocks. |
| 230013 | Extra over Item No. 230/003 for valves and stopcocks. |
| 230014 | Extra over Item No. 230/004 for valves and stopcocks. |
| 230015 | Extra over Item No. 230/005 for valves and stopcocks. |
| 230016 | Extra over Item No. 230/006 for valves and stopcocks. |
| 230017 | Extra over Item No. 230/007 for valves and stopcocks. |
| 230018 | Extra over Item No. 230/008 for valves and stopcocks. |
| 230019 | Portable type toilet. |
| 230020 | Extra over Item No. 230/019 for cleaning and maintenance. |
| 230021 | Fix only flushing cistern for W.C. or urinals, including connection of flush pipe and inlet pipe. |
| 230022 | Take down and remove existing flushing cistern for W.C. or urinals including disconnection of flush pipe and inlet pipe. |
| 230023 | Supply and fix W.C. seats including removal of old seats. |
| 230024 | Provide attendance to the Engineer or his staff for carrying out in-situ Sand Replacement Test. |
| 230025 | Extra over Item No. 230/024 for each additional working hour or part thereof beyond the period of 4 hours for each day’s operation. |
| 230026 | Extra over Item Nos. 230/024 for the supply of sand for test sample of 100 mm diameter. |
| 230027 | Supply, fix, maintain and remove 1.2 m long steel plates over trench, newly reinstated road surface, trial pit, pipe connection and the like of width up to 800 mm in carriageway as shown in Drawing No. WSD 1.3. |
| 230028 | As Item No. 230/027, but for trench width exceeding 800 mm and not exceeding 1,000 mm. |
| 230029 | As Item No. 230/027, but for trench width exceeding 1,000 mm and not exceeding 1,500 mm. |
| 230030 | As Item No.230/027, but for trench width exceeding 1,500 mm and not exceeding 1,800 mm. |
| 230031 | As Item No. 230/027, but for trench width exceeding 1,800 mm and not exceeding 2,000 mm. |
| 230032 | Disposal of asbestos wastes. |
| 230033 | Tell-tales on cracks. |
| 230034 | Supply for temporary use a modular type mobile inspection platform of 10 m maximum height for the use of the Engineer for inspection of service reservoir and building structures. |
| 230035 | Maintain the inspection platform provided in Item No. 230/034. |
| 230036 | Extra over Item No. 230/034 for each additional 2m of height or part thereof |
| 230036a | Supply, fix, maintain and remove temporary metal inspection platform of an area not less than 1.8 m x 1.2 m and of 10 m maximum height for the use of the Engineer. |
| 230036b | Extra over Item No. 230/036a for each additional 2m of height or part thereof. |
| 230037 | Bitumen dressing compound to horizontal and inclined surfaces sloping at 45 degree or less to the horizontal. Rate of application 0.54 kg/m2. |
| 230038 | As Item No. 230/037, but poured and spread at a rate of 1.6 kg/ m2. |
| 230039 | Remove existing asphaltic roofing in roofs including tiles, surface coating and mastic asphalt and prepare surface for relaying. |
| 230040 | Isolating membrane to G.S. Clause 24.02 on horizontal and inclined surfaces sloping at 45 degree or less to the horizontal. The felt is to be rolled into the hot bitumen of the mopping or bonding coat following up at a distance of 1 m - 1.5 m and using a roller weighing not less than 70 kg. |
| 230041 | As Item No. 230/040, but self finished membrane for top layers, weighing 13 kg per roll of 10 m2. |
| 230042 | As Item No. 230/040, but self finished membrane, weighing 18 kg per roll of 10 m2. |
| 230043 | As Item No. 230/040, but self finished membrane, weighing 23 kg per roll of 10 m2. |
| 230044 | Stone chippings to G.S. Clause 24.06 for surface finishing. |
| 230045 | Sand to G.S. Clause 24.05 for pressing and rolling into bitumen whilst hot. |
| 230046 | Mastic asphalt 20 mm thick as waterproofing to concrete roof in horizontal surfaces and inclined surfaces sloping at 45 degree or less to the horizontal. |
| 230047 | Acid resistant asphalt 30 mm thick as waterproofing to vertical surfaces and inclined surfaces sloping at more than 45 degree to the horizontal. |
| 230048 | Acid resistant asphalt 12.5 mm thick as waterproofing to horizontal surface and inclined surface sloping at 45 degree or less to horizontal. |
| 230049 | "Morter-PlasG" or approved bitumen membrane having equivalent functions and performance as waterproofing to horizontal surface and inclined surface sloping at 45 degree or less to horizontal. |
| 230050 | "Morter-PlasG" or approved bitumen membrane having equivalent functions and performance as waterproofing to horizontal surface and inclined surface sloping at more than 45 degree to the horizontal. |
| 230053 | Hot-applied bitumen rubber joint sealant to G.S. Clause 16.77(5) of cross section area up to 2,580 mm2 to horizontal surfaces. |
| 230054 | Extra over Item No. 230/053 for each additional increase of 625 mm2 cross section or part thereof in excess 2,580 mm2. |
| 230055 | Expansion joint filler to G.S. Clause 16.75, 25 mm thick. |
| 230056 | Expansion joint filler to G.S. Clause 16.75, 25 mm thick using polymer cement waterproofing slurry "Masterseal 540" or approved equivalent. |
| 230057 | Extra over Item No. 230/055 & 230/056 for raking out of old materials in joints. |
| 230058 | Cold-applied bitumen rubber joint sealant to G.S. Clause 16.77(6) for vertical or inclined surfaces other than construction joints. |
| 230059 | Polysulphide-based joint sealant to G.S. Clause 16.77(3) or Polyurethane-based joint sealant to G.S. Clause 16.77(4) for vertical and horizontal expansion joints up to 1,000 mm2 cross section area. |
| 230060 | Extra over Item No. 230/059 for each increase of 625 mm2 in cross section or part thereof in excess of 1,000 mm2. |
| 230061 | "Servigard" or equivalent approved products having equivalent functions or performance as joint sealant for vertical and horizontal joints up to 400mm2 cross section area. |
| 230062 | Joint sealant between precast concrete covers. |
| 230063 | Supply and install "Masterflex 900" or approved equivalent injection hose for gouting works. |
| 230064 | Grout the injection hose with vinylester base, water based swelling injection resin "Masterflex 801" or approved equivalent. |
| 230065 | Drill and insert grout tube to a depth of 150 mm along the joints at 500 mm centres. |
| 230066 | Extra over Item No. 230/065 for each increase of 50 mm in depth or part thereof in excess of 150 mm. |
| 230068 | Supply and fix approved venetian blinds to windows. |
| 230069 | Remove existing venetian blinds from windows. |
| 230070 | Clear blockage for urinals. |
| 230071 | Clear blockage for pan type W.C. |
| 230072 | Clear blockage for Asian type W.C. |
| 230073 | Supply and fix approved nylon mosquito netting to windows and doors. |
| 230074 | Remove and replace existing mosquito netting with new nylon mosquito netting and beading. |
| 230075 | Fix only mortice locks and latches in doors. |
| 230076 | As Item No. 230/075 but rim latches, door closers, locking bars and door furniture. |
| 230077 | Remove from doors mortice locks, latches, door closers, locking bars and door furniture for re-use. |
| 230078 | High pressure water jet cleaning to floors, walls, ceilings and roofs (minimum water pressure 280 bars and minimum flow rate 20 litres/minute). |
| 230079 | Supply silt curtain with height not exceeding 10m for temporary use. |
| 230080 | Maintain silt curtain with height not exceeding 10m. |
| 230081 | Supply oil absorbent boom of 20 cm diameter or width. |
| 230082 | Supply oil absorbent boom of 13 cm diameter or width. |
| 230083 | Supply and lay 40mm thick "Roofmate SL-A" insulation foam board on roof. |
| 230084 | Supply and lay 2mm thick "AB-PUR 500" polyurea waterproof membrance. |
| 230084a | Supply and lay 2mm thick "Sika-901" polyurea spray type waterproof membrane or equivalent. |
| 230084b | Supply and lay "Sikafloor 165" primer or equivalent bonding agent. |
| 230084c | Supply and lay "Sikalastic Eau Top" or equivalent UV-resistant protection coating. |
| 230084d | Supply and lay "Sikalastic Eau Top" with antislip system or equivalent UV protection top coat with antislip system. |
| 230085 | Dispatch of Form WWO49 with a quantity not exceeding 100 copies. |
| 230086 | Extra over Item No. 230/085 for each additional copy of Form WWO49 dispatched in excess of 100 copies. |
| 230087 | Supply of Fibre-Reinforced Polymer (FRP) Mesh Grating without WSD Logo as specified in PS Clause 22.32 |
| 230088 | Installation of Fibre-Reinforced Polymer (FRP) Mesh Grating as specified in PS Clause 22.32 |
| 230089 | Inspection of waterworks installations or location specified by the Engineer and in accordance with the Particular Specification Section 45.10 for the first 2-hours inspection. |
| 230090 | Extra over for each additional 15 minutes of inspection or part thereof using UAV after the first 2-hours of inspection. |
| 230091 | Submission of inspection report in accordance with the Particular Specifcation Section 45.10. |
| 230092 | Flow controllers installation for household |
| 230093 | Flow controllers installation for school |
| 240 | Permit Fees |
| 241 | (Not used) Designated Sub-contractor |
| 242 | Supply of materials |
| 243 | Traffic Impact Assessment Report |
| 244 | Independent checking of temporary works |
| 245 | Transportation of plants |
| 247 | Pressure Management and Continuous Monitoring Assessment |
| 248 | Assistance to Engineer - Site Clerk |
| 249 | Assistance to Engineer - Permit Controller, Public Liaison Manager, Field Officer |
| 250 | Assistance to Engineer - Permit Assistant, Distribution Worker |
| 251 | Assistance to Engineer - Meter Works Co-ordinator, Distribution Ganger |
| 252 | Assistant to Engineer - Investigator, Senior Meter Works Co-ordinator |
| 253 | Assistant to Engineer - Investigation Leader |
| 254 | Assistant to Engineer - Contract Field Officer |
| 260001 | Mobilization to site within 24 hours to carry out leakage detection work for prescribed sections of water main (not exceeding 200 m in total length of pipe(s) surveyed) upon instruction given by the Engineer or his Representatives. |
| 260002 | Mobilization to site at a time more than twenty-four hours to carry out leakage detection work for prescribed sections of water main (not exceeding 200 m in total length of pipe(s) surveyed) upon instruction given by the Engineer or his Representatives. |
| 260003 | Extra over Item Nos. 260/001 and 260/002 for each additional pipe length. |
| 260004 | Extra over Item No. 260/001 for mobilization to site within 8 hours. |
| 260005 | Extra over Item No. 260/001 for mobilization to site within 4 hours. |
| 260006 | Extra over Item No. 260/001 for mobilization to site within 2 hours. |
| 260007 | Leakage Detection Work on Prescribed Sections of Water Mains not exceeding 200 m length. |
| 260008 | Extra over item no. 260/007 for each additional pipe length. |
| 260012 | Leak Pinpointing Following Failure to Locate Leaks by Leak Exposing on Water Mains not exceeding 200 m length. |
| 260013 | Extra over item no. 260/012 for each additional pipe length |
| 260017 | Leak Exposing Existing carriageway : depth not exceeding 1.50 m. |
| 260018 | Leak Exposing Existing carriageway : depth exceeding 1.50 m but not exceeding 2.5 m. |
| 260019 | Leak Exposing Existing carriageway : depth exceeding 2.5 m but not exceeding 3.5 m. |
| 260020 | Leak Exposing Existing footway and cycle track : depth not exceeding 1.50 m. |
| 260021 | Leak Exposing Existing footway and cycle track : depth exceeding 1.50 m but not exceeding 2.5 m. |
| 260022 | Leak Exposing Existing footway and cycle track :depth exceeding 2.5 m but not exceeding 3.5 m. |
| 260023 | Leak Exposing Existing field track : depth not exceeding 1.50 m. |
| 260024 | Leak Exposing Existing field track : depth exceeding 1.50 m but not exceeding 2.5 m. |
| 260025 | Leak Exposing Existing field track :depth exceeding 2.5 m but not exceeding 3.5 m. |
| 260026 | Exposing Leakage Survey Contact Points Existing carriageway :- depth not exceeding 1.50 m. |
| 260027 | Exposing Leakage Survey Contact Points Existing carriageway :- depth exceeding 1.50 m but not exceeding 2.5 m. |
| 260028 | Exposing Leakage Survey Contact Points Existing carriageway :- depth exceeding 2.5 m but not exceeding 3.5 m. |
| 260029 | Exposing Leakage Survey Contact Points Existing concrete footway :- depth not exceeding 1.50 m. |
| 260030 | Exposing Leakage Survey Contact Points Existing concrete footway :-depth exceeding 1.50 m but not exceeding 2.5 m. |
| 260031 | Exposing Leakage Survey Contact Points Existing concrete footway :-depth exceeding 2.5 m but not exceeding 3.5 m. |
| 260032 | Exposing Leakage Survey Contact Points Existing field track :- depth not exceeding 1.50 m. |
| 260033 | Exposing Leakage Survey Contact Points Existing field track :- depth exceeding 1.50 m but not exceeding 2.5 m. |
| 260034 | Exposing Leakage Survey Contact Points Existing field track :- depth exceeding 2.5 m but not exceeding 3.5 m. |
| 261001 | Establishment of CCTV equipment. |
| 261002 | CCTV Survey according to PS Section 28 on Prescribed Sections of Water Mains and Drain Pipes: DN150 and below. |
| 261003 | CCTV Survey according to PS Section 28 on Prescribed Sections of Water Mains and Drain Pipes: DN200. |
| 261004 | CCTV Survey according to PS Section 28 on Prescribed Sections of Water Mains and Drain Pipes: DN250. |
| 261005 | CCTV Survey according to PS Section 28 on Prescribed Sections of Water Mains and Drain Pipes: DN300. |
| 261006 | CCTV Survey according to PS Section 28 on Prescribed Sections of Water Mains and Drain Pipes: DN375. |
| 261007 | CCTV Survey according to PS Section 28 on Prescribed Sections of Water Mains and Drain Pipes: DN400. |
| 261008 | CCTV Survey according to PS Section 28 on Prescribed Sections of Water Mains and Drain Pipes: DN450. |
| 261009 | CCTV Survey according to PS Section 28 on Prescribed Sections of Water Mains and Drain Pipes: DN600 and above. |
| 261010 | Establishment of non-destructive utility survey equipment. |
| 261011 | Non-destructive Utility Survey according to PS Section 29 for Prescribed Areas of: 500 sq. m. and below. |
| 261012 | Non-destructive utility survey according to PS Section 29 for prescribed areas of: exceeding 500 sq. m. but not exceeding 2,500 sq. m. |
| 261013 | Non-destructive utility survey according to PS Section 29 for prescribed areas of: exceeding 2,500 sq. m. but not exceeding 5,000 sq. m. |
| 261014 | Non-destructive utility survey according to PS Section 29 for prescribed areas of: exceeding 5,000 sq. m. but not exceeding 10,000 sq. m. |
| 261015 | Non-destructive utility survey according to PS Section 29 for prescribed areas of: exceeding 10,000 sq. m. but not exceeding 15,000 sq. m. |
| 261016 | Non-destructive utility survey according to PS Section 29 for prescribed areas of: exceeding 15,000 sq. m. |
| 261017 | Pipe coating defect measurement by Coating Defect Survey technique as specified in PS Clause 29.28 or any alternative equivalent survey technique as approved by the Engineer. |
| 261018 | Testing of soil corrosivity by Linear Polarization Resistance (LPR) Soil Testing as specified in PS Clause 29.29 or any alternative equivalent survey technique as approved by the Engineer. |
| 261019 | Pipe wall thickness measurement by Broadband Electromagnetic (BEM) Survey as specified in PS Clause 29.30, Mainscan or Intensive Ultrasonic Test or any alternative equivalent survey technique as approved by the Engineer. |
| 261020 | Stray current meaurement as specified in PS Clause 29.31 on a prescribed section of water main. |
| 261021 | Mobilization and demobilization for underwater survey and inspection works. |
| 261022 | Underwater survey and inspection. |
| 261023 | Underwater survey and inspection report. |
| 261024 | Soil aggressivity assessment and report as specified in PS Clause 29.38. |
| 261025 | Collection of pipe samples for forensic analysis as specified in PS Clause 29.39. |
| 262001A | Supply of flowmeters/water meters : Mechanical flowmeters. Nominal diameter of flowmeter 50 mm |
| 262001AA | Supply of flowmeters/water meters : Ultrasonc flowmeters /water meters Nominal diameter of flowmeter 50mm |
| 262001B | Supply of flowmeters/water meters : Mechanical flowmeters. Nominal diameter of flowmeter 80 mm |
| 262001C | Supply of flowmeters/water meters : Mechanical flowmeters. Nominal diameter of flowmeter 100 mm |
| 262001D | Supply of flowmeters/water meters : Mechanical flowmeters. Nominal diameter of flowmeter 150 mm |
| 262001E | Supply of flowmeters/water meters : Mechanical flowmeters. Nominal diameter of flowmeter 200 mm |
| 262001F | Supply of flowmeters/water meters : Mechanical flowmeters. Nominal diameter of flowmeter 250 mm |
| 262001G | Supply of flowmeters/water meters : Mechanical flowmeters. Nominal diameter of flowmeter 300 mm |
| 262001O | Supply of flowmeters/water meters : Mechanical flowmeters / water meters /water meters Nominal diameter of flowmeter 40mm |
| 262002A | Supply of flowmeters/water meters : Electromagnetic flowmeters for the use of potable and raw water. Nominal diameter of flowmeter 50 mm |
| 262002B | Supply of flowmeters/water meters : Electromagnetic flowmeters for the use of potable and raw water. Nominal diameter of flowmeter 80mm |
| 262002C | Supply of flowmeters/water meters : Electromagnetic flowmeters for the use of potable and raw water. Nominal diameter of flowmeter 100mm |
| 262002D | Supply of flowmeters/water meters : Electromagnetic flowmeters for the use of potable and raw water. Nominal diameter of flowmeter 150mm |
| 262002E | Supply of flowmeters/water meters : Electromagnetic flowmeters for the use of potable and raw water. Nominal diameter of flowmeter 200mm |
| 262002F | Supply of flowmeters/water meters : Electromagnetic flowmeters for the use of potable and raw water. Nominal diameter of flowmeter 250mm |
| 262002G | Supply of flowmeters/water meters : Electromagnetic flowmeters for the use of potable and raw water. Nominal diameter of flowmeter 300mm |
| 262002H | Supply of flowmeters/water meters : Electromagnetic flowmeters for the use of potable and raw water. Nominal diameter of flowmeter 400mm |
| 262002I | Supply of flowmeters/water meters : Electromagnetic flowmeters for the use of potable and raw water. Nominal diameter of flowmeter 450mm |
| 262002J | Supply of flowmeters/water meters : Electromagnetic flowmeters for the use of potable and raw water. Nominal diameter of flowmeter 600mm |
| 262004 | Install flowmeters with nominal diameter 150 mm and below. |
| 262005 | Install flowmeters with nominal diameter 200 mm to 300 mm. |
| 262006 | Install flowmeters with nominal diameter 400 mm and above. |
| 262007 | Extra over item 262/004 for buried electromagnetic flowmeters. |
| 262008 | Extra over item 262/005 for buried electromagnetic flowmeters. |
| 262009 | Extra over item 262/006 for buried electromagnetic flowmeters. |
| 262010 | Replace batteries of electromagnetic flowmeters |
| 263001A | Supply of Pressure Reducing Valves and In-line Strainers : reduced port pressure reducing valves (diaphragm type). Nominal diameter 50 mm |
| 263001B | Supply of Pressure Reducing Valves and In-line Strainers : reduced port pressure reducing valves (diaphragm type). Nominal diameter 80 mm |
| 263001C | Supply of Pressure Reducing Valves and In-line Strainers : reduced port pressure reducing valves (diaphragm type). Nominal diameter 100mm |
| 263001D | Supply of Pressure Reducing Valves and In-line Strainers : reduced port pressure reducing valves (diaphragm type). Nominal diameter 150mm |
| 263001E | Supply of Pressure Reducing Valves and In-line Strainers : reduced port pressure reducing valves (diaphragm type). Nominal diameter 200mm |
| 263001F | Supply of Pressure Reducing Valves and In-line Strainers : reduced port pressure reducing valves (diaphragm type). Nominal diameter 250mm |
| 263001G | Supply of Pressure Reducing Valves and In-line Strainers : reduced port pressure reducing valves (diaphragm type). Nominal diameter 300mm |
| 263001H | Supply of Pressure Reducing Valves and In-line Strainers : reduced port pressure reducing valves (diaphragm type). Nominal diameter 400mm |
| 263001I | Supply of Pressure Reducing Valves and In-line Strainers : reduced port pressure reducing valves (diaphragm type). Nominal diameter 450mm |
| 263001J | Supply of Pressure Reducing Valves and In-line Strainers : reduced port pressure reducing valves (diaphragm type). Nominal diameter 600mm |
| 263002A | Supply of Pressure Reducing Valves and In-line Strainers : full port pressure reducing valves (diaphragm type). Nominal diameter 50 mm |
| 263002B | Supply of Pressure Reducing Valves and In-line Strainers : full port pressure reducing valves (diaphragm type). Nominal diameter 80 mm |
| 263002C | Supply of Pressure Reducing Valves and In-line Strainers : full port pressure reducing valves (diaphragm type). Nominal diameter 100 mm |
| 263002D | Supply of Pressure Reducing Valves and In-line Strainers : full port pressure reducing valves (diaphragm type). Nominal diameter 150 mm |
| 263002E | Supply of Pressure Reducing Valves and In-line Strainers : full port pressure reducing valves (diaphragm type). Nominal diameter 200 mm |
| 263002F | Supply of Pressure Reducing Valves and In-line Strainers : full port pressure reducing valves (diaphragm type). Nominal diameter 250 mm |
| 263002G | Supply of Pressure Reducing Valves and In-line Strainers : full port pressure reducing valves (diaphragm type). Nominal diameter 300 mm |
| 263002H | Supply of Pressure Reducing Valves and In-line Strainers : full port pressure reducing valves (diaphragm type). Nominal diameter 400 mm |
| 263002I | Supply of Pressure Reducing Valves and In-line Strainers : full port pressure reducing valves (diaphragm type). Nominal diameter 450 mm |
| 263002J | Supply of Pressure Reducing Valves and In-line Strainers : full port pressure reducing valves (diaphragm type). Nominal diameter 600 mm |
| 263003A | Supply of Pressure Reducing Valves and In-line Strainers : full port pressure reducing valves (piston type). Nominal diameter 50 mm |
| 263003B | Supply of Pressure Reducing Valves and In-line Strainers : full port pressure reducing valves (piston type). Nominal diameter 80 mm |
| 263003C | Supply of Pressure Reducing Valves and In-line Strainers : full port pressure reducing valves (piston type). Nominal diameter 100 mm |
| 263003D | Supply of Pressure Reducing Valves and In-line Strainers : full port pressure reducing valves (piston type). Nominal diameter 150 mm |
| 263003E | Supply of Pressure Reducing Valves and In-line Strainers : full port pressure reducing valves (piston type). Nominal diameter 200 mm |
| 263003F | Supply of Pressure Reducing Valves and In-line Strainers : full port pressure reducing valves (piston type). Nominal diameter 250 mm |
| 263003G | Supply of Pressure Reducing Valves and In-line Strainers : full port pressure reducing valves (piston type). Nominal diameter 300 mm |
| 263003H | Supply of Pressure Reducing Valves and In-line Strainers : full port pressure reducing valves (piston type). Nominal diameter 400 mm |
| 263003I | Supply of Pressure Reducing Valves and In-line Strainers : full port pressure reducing valves (piston type). Nominal diameter 450 mm |
| 263003J | Supply of Pressure Reducing Valves and In-line Strainers : full port pressure reducing valves (piston type). Nominal diameter 600 mm |
| 263004A | Supply of Pressure Reducing Valves and In-line Strainers : in-line strainers (H type). Nominal diameter 50 mm |
| 263004B | Supply of Pressure Reducing Valves and In-line Strainers : in-line strainers (H type). Nominal diameter 80 mm |
| 263004C | Supply of Pressure Reducing Valves and In-line Strainers : in-line strainers (H type). Nominal diameter 100 mm |
| 263004D | Supply of Pressure Reducing Valves and In-line Strainers : in-line strainers (H type). Nominal diameter 150 mm |
| 263004E | Supply of Pressure Reducing Valves and In-line Strainers : in-line strainers (H type). Nominal diameter 200 mm |
| 263004F | Supply of Pressure Reducing Valves and In-line Strainers : in-line strainers (H type). Nominal diameter 250 mm |
| 263004G | Supply of Pressure Reducing Valves and In-line Strainers : in-line strainers (H type). Nominal diameter 300 mm |
| 263004H | Supply of Pressure Reducing Valves and In-line Strainers : in-line strainers (H type). Nominal diameter 400 mm |
| 263004I | Supply of Pressure Reducing Valves and In-line Strainers : in-line strainers (H type). Nominal diameter 450 mm |
| 263004J | Supply of Pressure Reducing Valves and In-line Strainers : in-line strainers (H type). Nominal diameter 600 mm |
| 263005A | Supply of Pressure Reducing Valves and In-line Strainers : in-line strainers (Y type). Nominal diameter 50 mm |
| 263005B | Supply of Pressure Reducing Valves and In-line Strainers : in-line strainers (Y type). Nominal diameter 80 mm |
| 263005C | Supply of Pressure Reducing Valves and In-line Strainers : in-line strainers (Y type). Nominal diameter 100 mm |
| 263005D | Supply of Pressure Reducing Valves and In-line Strainers : in-line strainers (Y type). Nominal diameter 150 mm |
| 263005E | Supply of Pressure Reducing Valves and In-line Strainers : in-line strainers (Y type). Nominal diameter 200 mm |
| 263005F | Supply of Pressure Reducing Valves and In-line Strainers : in-line strainers (Y type). Nominal diameter 250 mm |
| 263005G | Supply of Pressure Reducing Valves and In-line Strainers : in-line strainers (Y type). Nominal diameter 300 mm |
| 263005H | Supply of Pressure Reducing Valves and In-line Strainers : in-line strainers (Y type). Nominal diameter 400 mm |
| 263005I | Supply of Pressure Reducing Valves and In-line Strainers : in-line strainers (Y type). Nominal diameter 450 mm |
| 263005J | Supply of Pressure Reducing Valves and In-line Strainers : in-line strainers (Y type). Nominal diameter 600 mm |
| 263006A | Supply of Pressure Reducing Valves and In-line Strainers : in-line strainers (basket type). Nominal diameter 50 mm |
| 263006B | Supply of Pressure Reducing Valves and In-line Strainers : in-line strainers (basket type). Nominal diameter 80 mm |
| 263006C | Supply of Pressure Reducing Valves and In-line Strainers : in-line strainers (basket type). Nominal diameter 100 mm |
| 263006D | Supply of Pressure Reducing Valves and In-line Strainers : in-line strainers (basket type). Nominal diameter 150 mm |
| 263006E | Supply of Pressure Reducing Valves and In-line Strainers : in-line strainers (basket type). Nominal diameter 200 mm |
| 263006F | Supply of Pressure Reducing Valves and In-line Strainers : in-line strainers (basket type). Nominal diameter 250 mm |
| 263006G | Supply of Pressure Reducing Valves and In-line Strainers : in-line strainers (basket type). Nominal diameter 300 mm |
| 263006H | Supply of Pressure Reducing Valves and In-line Strainers : in-line strainers (basket type). Nominal diameter 400 mm |
| 263006I | Supply of Pressure Reducing Valves and In-line Strainers : in-line strainers (basket type). Nominal diameter 450 mm |
| 263006J | Supply of Pressure Reducing Valves and In-line Strainers : in-line strainers (basket type). Nominal diameter 600 mm |
| 263006aa | Supply of separators with nominal diameter 80 mm. |
| 263007 | Supply of pressure gauges. |
| 263008 | Supply of electronic pressure reducing valve controllers. |
| 263008a | Supply of electronic pressure reducing valve controllers (NB-IoT). |
| 263009 | Install pressure reducing valves with nominal diameter 150 mm or below. |
| 263010 | Install pressure reducing valves with nominal diameter 200 mm to 300 mm. |
| 263011 | Install pressure reducing valves with nominal diameter 400 mm or above. |
| 263012 | Install in-line strainers with nominal diameter 150 mm or below. |
| 263013 | Install in-line strainers with nominal diameter 200 mm to 300 mm. |
| 263014 | Install in-line strainers with nominal diameter 400 mm or above. |
| 263014a | Install separators with nominal diameter 80 mm with chambers. |
| 263015 | Install pressure gauges. |
| 263016 | Install electronic pressure reducing valve controllers. |
| 263017 | Maintenance of pressure reducing valves with nominal diameter 150 mm or below. |
| 263018 | Maintenance of pressure reducing valves with nominal diameter 200 mm to 300 mm. |
| 263019 | Maintenance of pressure reducing valves with nominal diameter 400 mm or above. |
| 263020 | Maintenance of strainers/in-line strainers/separators with nominal diameter 150 mm or below. |
| 263021 | Maintenance of in-line strainers with nominal diameter 200 mm to 300 mm. |
| 263022 | Maintenance of in-line strainers with nominal diameter 400 mm or above. |
| 264001 | Supply of wireless transmission noise loggers Wireless noise loggers, NB-IoT transmission. |
| 264002 | Supply of modems. |
| 264003 | Supply of Interrogators for noise loggers. |
| 264004 | Supply of Radio signal transmission noise loggers |
| 264005 | Supply of Patrollers. |
| 264006 | Supply of Interrogators for noise loggers. |
| 264007 | Install noise loggers. |
| 264008 | As Item No. 264/007, but for a batch of noise loggers within an area of 1 km x 1 km, the total number of noise loggers exceeding 5 but not exceeding 10. |
| 264009 | As Item No. 264/008, but for a number of noise loggers exceeding 10 but not exceeding 20. |
| 264010 | As Item No. 264/008, but for a number of noise loggers exceeding 20 but not exceeding 30. |
| 264011 | As Item No. 264/008, but for a number of noise loggers exceeding 30 but not exceeding 40. |
| 264012 | As Item No. 264/008, but for a number of noise loggers exceeding 40. |
| 264013 | Extra over Item Nos. 264/007, 264/008, 264/009, 264/010, 264/011 & 264/012 for replacement of noise loggers. |
| 264014 | Remove noise loggers for re-use. |
| 264015 | As Item No. 264/014, but for a batch of noise loggers within an area 1 km x 1 km, the total number of noise loggers exceeding 5 but not exceeding 10. |
| 264016 | As Item No. 264/015, but for a number of noise loggers exceeding 10 but not exceeding 20. |
| 264017 | As Item No. 264/015, but for a number of noise loggers exceeding 20 but not exceeding 30. |
| 264018 | As Item No. 264/015, but for a number of noise loggers exceeding 30 but not exceeding 40. |
| 264019 | As Item No. 264/015, but for a number of noise loggers exceeding 40. |
| 265001 | Supply of Data loggers with 1 pressure channel, NB-IoT |
| 265002 | Supply of Data loggers with 2 pressure channels, NB-IoT |
| 265003 | Supply of GSM modems. |
| 265004 | Install data loggers. |
| 265005 | As item no. 265/004, but for a batch of data loggers in the same service reservoir supply zone, the total number of data loggers exceeding 5 but not exceeding 10. |
| 265006 | As item no. 265/005, but for a number of data loggers exceeding 10 but not exceeding 20. |
| 265007 | As item no. 265/005, but for a number of data loggers exceeding 20 but not exceeding 30. |
| 265008 | As item no. 265/005, but for a number of data loggers exceeding 30 but not exceeding 40. |
| 265009 | As item no. 265/005, but for a number of data loggers exceeding 40. |
| 265010 | Extra over Items Nos. 265/004, 265/005, 265/006, 265/007, 265/008 & 265/009 for replacement of data loggers. |
| 265010a | Extra over Items Nos. 265/004, 265/005, 265/006, 265/007, 265/008 & 265/009 for cable connection and configuration setting of master meter. |
| 265011 | Remove data loggers for re-use. |
| 265012 | As item no. 265/011, but for a batch of data loggers in the same service reservoir supply zone, the total number of data loggers exceeding 5 but not exceeding 10. |
| 265013 | As item no. 265/012, but for a number of data loggers exceeding 10 but not exceeding 20. |
| 265014 | As item no. 265/012, but for a number of data loggers exceeding 20 but not exceeding 30. |
| 265015 | As item no. 265/012, but for a number of data loggers exceeding 30 but not exceeding 40. |
| 265016 | As item no. 265/012, but for a number of data loggers exceeding 40. |
| 266001A | Mechanical or electromagnetic flowmeter chambers on footpath for pipes of nominal diameter up to and including 150 mm, as shown in Drawing No. WSD 1.41. Depth of chamber not exceeding 1.5 m |
| 266001B | Mechanical or electromagnetic flowmeter chambers on footpath for pipes of nominal diameter up to and including 150 mm, as shown in Drawing No. WSD 1.41. Depth of chamber exceeding 1.5 m but not exceeding 2.5 m |
| 266001C | Mechanical or electromagnetic flowmeter chambers on footpath for pipes of nominal diameter up to and including 150 mm, as shown in Drawing No. WSD 1.41. Depth of chamber exceeding 2.5 m |
| 266002A | Mechanical or electromagnetic flowmeter chambers on footpath, but for pipes of nominal diameter greater than 150 mm but not greater than 300 mm. Depth of chamber not exceeding 1.5 m |
| 266002B | Mechanical or electromagnetic flowmeter chambers on footpath, but for pipes of nominal diameter greater than 150 mm but not greater than 300 mm. Depth of chamber exceeding 1.5 m but not exceeding 2.5 m |
| 266002C | Mechanical or electromagnetic flowmeter chambers on footpath, but for pipes of nominal diameter greater than 150 mm but not greater than 300 mm. Depth of chamber exceeding 2.5 m |
| 266003A | Electromagnetic flowmeter chambers on carriageway for pipes of nominal diameter up to and including 150 mm, as shown in Drawing No. WSD 1.41. Depth of chamber not exceeding 1.5 m |
| 266003B | Electromagnetic flowmeter chambers on carriageway for pipes of nominal diameter up to and including 150 mm, as shown in Drawing No. WSD 1.41. Depth of chamber exceeding 1.5 m but not exceeding 2.5 m |
| 266003C | Electromagnetic flowmeter chambers on carriageway for pipes of nominal diameter up to and including 150 mm, as shown in Drawing No. WSD 1.41. Depth of chamber exceeding 2.5 m |
| 266004A | Electromagnetic flowmeter chambers on carriageway, but for pipes of nominal diameter greater than 150 mm but not greater than 300 mm. Depth of chamber not exceeding 1.5 m |
| 266004B | Electromagnetic flowmeter chambers on carriageway, but for pipes of nominal diameter greater than 150 mm but not greater than 300 mm. Depth of chamber exceeding 1.5 m but not exceeding 2.5 m |
| 266004C | Electromagnetic flowmeter chambers on carriageway, but for pipes of nominal diameter greater than 150 mm but not greater than 300 mm. Depth of chamber exceeding 2.5 m |
| 266005A | Transmitter pits on footpath. Depth of chamber not exceeding 1.5 m |
| 266005B | Transmitter pits on footpath. Depth of chamber exceeding 1.5 m but not exceeding 2.5 m |
| 266005C | Transmitter pits on footpath. Depth of chamber exceeding 2.5 m |
| 266006A | Pressure reducing valve chambers on footpath for pipes of nominal diameter up to and including 150 mm. Depth of chamber not exceeding 1.5 m |
| 266006B | Pressure reducing valve chambers on footpath for pipes of nominal diameter up to and including 150 mm. Depth of chamber exceeding 1.5 m but not exceeding 2.5 m |
| 266006C | Pressure reducing valve chambers on footpath for pipes of nominal diameter up to and including 150 mm. Depth of chamber exceeding 2.5 m |
| 266007A | Ditto, but for pipes of nominal diameter greater than 150 mm but not greater than 300 mm. Depth of chamber not exceeding 1.5 m |
| 266007B | Ditto, but for pipes of nominal diameter greater than 150 mm but not greater than 300 mm. Depth of chamber exceeding 1.5 m but not exceeding 2.5 m |
| 266007C | Ditto, but for pipes of nominal diameter greater than 150 mm but not greater than 300 mm. Depth of chamber exceeding 2.5 m |
| 266008A | In-line strainer chambers on footpath for pipes of nominal diameter up to and including 150 mm. Depth of chamber not exceeding 1.5 m |
| 266008B | In-line strainer chambers on footpath for pipes of nominal diameter up to and including 150 mm. Depth of chamber exceeding 1.5 m but not exceeding 2.5 m |
| 266008C | In-line strainer chambers on footpath for pipes of nominal diameter up to and including 150 mm. Depth of chamber exceeding 2.5 m |
| 266009A | Ditto, but for pipes of nominal diameter greater than 150 mm but not greater than 300 mm. Depth of chamber not exceeding 1.5 m |
| 266009B | Ditto, but for pipes of nominal diameter greater than 150 mm but not greater than 300 mm. Depth of chamber exceeding 1.5 m but not exceeding 2.5 m |
| 266009C | Ditto, but for pipes of nominal diameter greater than 150 mm but not greater than 300 mm. Depth of chamber exceeding 2.5 m |
| 266010A | Flowmeter and pressure reducing valve combined chambers on footpath for pipes of nominal diameter up to and including 150 mm. Depth of chamber not exceeding 1.5 m |
| 266010B | Flowmeter and pressure reducing valve combined chambers on footpath for pipes of nominal diameter up to and including 150 mm. Depth of chamber exceeding 1.5 m but not exceeding 2.5 m |
| 266010C | Flowmeter and pressure reducing valve combined chambers on footpath for pipes of nominal diameter up to and including 150 mm. Depth of chamber exceeding 2.5 m |
| 266011A | Ditto, but for pipes of nominal diameter greater than 150 mm but not greater than 300 mm. Depth of chamber not exceeding 1.5 m |
| 266011B | Ditto, but for pipes of nominal diameter greater than 150 mm but not greater than 300 mm. Depth of chamber exceeding 1.5 m but not exceeding 2.5 m |
| 266011C | Ditto, but for pipes of nominal diameter greater than 150 mm but not greater than 300 mm. Depth of chamber exceeding 2.5 m |
| 266012A | Flowmeter, pressure reducing valve and in-line strainer combined chambers on footpath for pipes of nominal diameter up to and including 150 mm. Depth of chamber not exceeding 1.5 m |
| 266012B | Flowmeter, pressure reducing valve and in-line strainer combined chambers on footpath for pipes of nominal diameter up to and including 150 mm. Depth of chamber exceeding 1.5 m but not exceeding 2.5 m |
| 266012C | Flowmeter, pressure reducing valve and in-line strainer combined chambers on footpath for pipes of nominal diameter up to and including 150 mm. Depth of chamber exceeding 2.5 m |
| 266013A | Ditto, but for pipes of nominal diameter greater than 150 mm but not greater than 300 mm. Depth of chamber not exceeding 1.5 m |
| 266013B | Ditto, but for pipes of nominal diameter greater than 150 mm but not greater than 300 mm. Depth of chamber exceeding 1.5 m but not exceeding 2.5 m |
| 266013C | Ditto, but for pipes of nominal diameter greater than 150 mm but not greater than 300 mm. Depth of chamber exceeding 2.5 m |
| 267001 | Group A District Metering Areas or Pressure Management Areas as shown in PS Appendix 48.01 or 49.01 |
| 267002 | Group B District Metering Areas or Pressure Management Areas as shown in PS Appendix 48.01 or 49.01 |
| 267003 | Group C District Metering Areas or Pressure Management Areas as shown in PS Appendix 48.01 or 49.01 |
| 267004 | Group D District Metering Areas or Pressure Management Areas as shown in PS Appendix 48.01 or 49.01 |
| 267005 | Reduction of Water Loss in the Selected District Metering Areas or Pressure Management Areas |
| 267006 | Extra over Item Nos. 267/001 to 267/002 for identifying each Illegal Connection in the specified District Metering Areas or Pressure Management Areas |
| 268001 | Inline Leakage Detection of In-service Pressurised Water Mains Mobilization of Staff, Plant and Equipment for In-line Leakage Detection of prescribed section of In-Service Pressurised Water Mains |
| 268002 | Inline Leakage Detection of In-service Pressurised Water Project planning and preparation Mains |
| 268003 | Inline Leakage Detection of In-service Pressurised Water In-line Leakage Detection Mains |
| 268003a | Inline Leakage Detection of In-service Pressurised Water Extra over for CCTV inspection during leakage detection Mains |
| 268004 | Inline Leakage Detection of In-service Pressurised Water Analysis and reporting Mains |
| 270001 | Complete draft Safety Plan. |
| 270002 | Complete Safety Plan. |
| 270003 | Updating of Safety Plan. |
| 270004 | Provide Safety Officer. |
| 270005 | Attend Site Safety Management Committee. |
| 270006 | Attend Site Safety Committee. |
| 270007 | Arrange and attend weekly safety walk. |
| 270008 | Provide safety training in the form of trade specific advanced safety training to skilled workers. |
| 270009 | Provide safety training in the form of site specific induction training. |
| 270010 | Provide safety training in the form of tool box talks. |
| 270012 | Daily Cleaning |
| 270013 | Weekly Tidying |
| 290001 | For District K Inspection and Maintenance of service reservoirs detailed at PS Appendix 32.01 and in accordance with the Particular Specification Section 32. |
| 290002 | For District K Inspection and Maintenance of water tanks detailed at PS Appendix 32.01 and in accordance with the Particular Specification Section 32. |
| 290006 | For District K Inspection and Maintenance of water treatment works detailed at PS Appendix 36.01 and in accordance with the Particular Specification Section 36. |
| 290007 | For District K Inspection and Maintenance of access roads detailed at PS Appendix 36.01 and in accordance with the Particular Specification Section 36. |
| 290009 | For District K Inspection and Maintenance of access roads detailed at PS Appendix 38.01 and in accordance with the Particular Specification Section 38. |
| 290010 | For District K Inspection and Maintenance of depots and staff quarters detailed at PS Appendix 39.01 and in accordance with the Particular Specification Section 39. |
| 291001 | For District L Inspection and Maintenance of service reservoirs detailed at PS Appendix 32.01 and in accordance with the Particular Specification Section 32. |
| 291002 | For District L Inspection and Maintenance of water tanks detailed at PS Appendix 32.01 and in accordance with the Particular Specification Section 32. |
| 291005 | For District L Inspection and Maintenance of catchwater detailed at PS Appendix 34.01 and in accordance with the Particular Specification Section 34. |
| 291006 | For District L Inspection and Maintenance of pumping stations detailed at PS Appendix 35.01 and in accordance with the Particular Specification Section 35. |
| 291007 | For District L Inspection and Maintenance of water treatment works detailed at PS Appendix 36.01 and in accordance with the Particular Specification Section 36. |
| 291008 | For District L Inspection and Maintenance of impounding reservoirs detailed at PS Appendix 37.01 and in accordance with the Particular Specification Section 37. |
| 291009 | For District L Inspection and Maintenance of access roads detailed at PS Appendix 38.01 and in accordance with the Particular Specification Section 38. |
| 291010 | For District L Inspection and Maintenance of depots and staff quarters detailed at PS Appendix 39.01 and in accordance with the Particular Specification Section 39. |
| 295001 | For District K Flushing of water mains within the Designated Contract Area and in accordance with the Particular Specification Section 42. |
| 295002 | For District K Provision of service connections within the Designated Contract Area and in accordance with the Particular Specification Section 43. |
| 295003 | For District K Trench Inspection Services in accordance with the Particular Specification Section 44. |
| 295004 | For District K Inspection and Maintenance of fire hydrants within the Designated Contract Area and in accordance with the Particular Specification Section 40. |
| 295005 | For District K Extra over for each additional fire hydrant to be inspected and maintained as specified in Clause 40.02(3) of the Particular Specification and in accordance with the Particular Specification Section 40. |
| 296001 | For District L Flushing of water mains within the Designated Contract Area and in accordance with the Particular Specification Section 42. |
| 296002 | For District L Provision of service connections within the Designated Contract Area and in accordance with the Particular Specification Section 43. |
| 296003 | For District L Inspection and Maintenance of fire hydrants within the Designated Contract Area and in accordance with the Particular Specification Section 40. |
| 296004 | For District L Extra over for each additional fire hydrant to be inspected and maintained as specified in Clause 40.02(3) of the Particular Specification and in accordance with the Particular Specification Section 40. |
| 310001 | Temporary safety fence Type A as Standard Drawings C2501/1D and C2501/2C |
| 310002 | Temporary safety fence Type B as Standard Drawings C2502/1E and C2502/2E |
| 310003 | Temporary safety fence Type C as Sketch R1062/1, R1062/2 and R1062/3 |
| 310004 | Removal of landslide debris |
| 310005 | Deposition and compaction of Grade 200 rock fill material |
| 310006 | In-situ Concrete, No-fines concrete |
| 310007 | In-situ Concrete, Grade 20 sprayed concrete infill |
| 310008 | Mesh protection as Standard Drawing C2205F |
| 310009 | Grade 20 sprayed concrete, with one layer of 50 mm x 50 mm x 2.7 mm (wire diameter) welded mesh, galvanised:- 50 mm thick |
| 310010 | Grade 20 sprayed concrete, with one layer of 50 mm x 50 mm x 2.7 mm (wire diameter) welded mesh, galvanised:- 75 mm thick |
| 310011 | Grade 20 sprayed concrete, with one layer of 50 mm x 50 mm x 2.7 mm (wire diameter) welded mesh, galvanised:- 100 mm thick |
| 310012 | Grade 20 sprayed concrete, without mesh: - 50 mm thick |
| 310013 | Grade 20 sprayed concrete, without mesh: - 75 mm thick |
| 310014 | Grade 20 sprayed concrete, without mesh: - 100 mm thick |
| 320001 | LoC for monitoring prescribed sections of water mains |
| 320002 | Operation, maintenance, monitoring for approved numbers of LoC and leak pinpointing work |
| 320003 | LoE for monitoring prescribed sections of water mains |
| 320004 | Operation, maintenance, monitoring for approved numbers of LoE and leak pinpointing work |
| 320005 | Extra over Item Nos. 320/002 and 320/004 for successful pinpointing of leaks in water mains of diameters less than or equal to 100mm subject to the deduction factor stated in PS Clause 46.10. |
| 320006 | Extra over Item Nos. 320/002 and 320/004 for successful pinpointing of leaks in water mains of diameters more than 100mm but less than or equal to 300mm subject to the deduction factor stated in PS Clause 46.10. |
| 320007 | Extra over Item Nos. 320/002 and 320/004 for successful pinpointing of leaks in water mains of diameters more than 300mm but less than or equal to 600mm subject to the deduction factor stated in PS Clause 46.10. |
| 320008 | Extra over Item Nos. 320/002 and 320/004 for successful pinpointing of leaks in water mains of diameters more than 600mm subject to the deduction factor stated in PS Clause 46.10. |
| 320009 | Extra over Item Nos. 320/002 and 320/004 for successful pinpointing of leaks in concealed valves subject to the deduction factor stated in PS Clause 46.10. |
| 320010 | Extra over Item Nos. 320/002 and 320/004 for successful pinpointing of leaks in valves by visual inspection. |
| 320011 | Extra over Item No. 320/004 for replacement of battery |
| 350001 | For District K Inspection and Maintenance of Facilities for each District Metering Areas and any additional District Metering Area ordered by the Engineer with thirty (30) or less number of chambers and pits in accordance with the Particular Specification Section 48. |
| 350002 | For District K Extra over for each additional chamber or pit exceeding thirty (30) numbers in a District Metering Areas in accordance with the Particular Specification Section 48. |
| 350003 | For District K Inspection and Maintenance of Facilities for Pressure Management Areas and any additional Pressure Management Area ordered by the Engineer with seventy (70) or less number of chambers and pits in accordance with the Particular Specification Section 49. |
| 350004 | For District K Extra over for each additional chamber exceeding seventy (70) numbers in a Pressure Management Areas in accordance with the Particular Specification Section 49. |
| 350005 | For District K Inspection and Maintenance of Facilities for each Master Meters and any additional Master Meter ordered by the Engineer with four (4) or less number of chambers and pits in accordance with the Particular Specification Section 50. |
| 350006 | For District K Extra over for each additional chamber or pit exceeding four (4) numbers in a Master Meters in accordance with the Particular Specification Section 50 |
| 351001 | For District L Inspection and Maintenance of Facilities for each District Metering Areas and any additional District Metering Area ordered by the Engineer with thirty (30) or less number of chambers and pits in accordance with the Particular Specification Section 48. |
| 351002 | For District L Extra over for each additional chamber or pit exceeding thirty (30) numbers in a District Metering Areas in accordance with the Particular Specification Section 48. |
| 351003 | For District L Inspection and Maintenance of Facilities for each Pressure Management Area and any additional Pressure Management Area ordered by the Engineer with seventy (70) or less number of chambers and pits in accordance with the Particular Specification Section 50. |
| 351004 | For District L Extra over for each additional chamber exceeding seventy (70) numbers in a Pressure Management Area in accordance with the Particular Specification Section 49. |
| 351005 | For District L Inspection and Maintenance of Facilities for each Master Meters and any additional Master Meter ordered by the Engineer with four (4) or less number of chambers and pits in accordance with the Particular Specification Section 50. |
| 351006 | For District L Extra over for each additional chamber or pit exceeding four (4) numbers in a Master Meters in accordance with the Particular Specification Section 50. |
| 360001 | For District K Inspection and Maintenance of man-made slopes detailed at PS Appendix 33.01 and in accordance with the Particular Specification Section 33. |
| 360002 | For District K Extra over for each additional man-made slope to be inspected and maintained as specified in Clause 33.02(1) of the Particular Specification and in accordance with the Particular Specification Section 33. |
| 361001 | For District L Inspection and Maintenance of man-made slopes detailed at PS Appendix 33.01 and in accordance with the Particular Specification Section 33. |
| 361002 | For District L Extra over for each additional man-made slope to be inspected and maintained as specified in Clause 33.02(1) of the Particular Specification and in accordance with the Particular Specification Section 33. |
| 370001 | For District K Inspection and Maintenance of Sacrificial Anode Cathodic Protection (SACP) System as specified in Particular Specification Section 51. |
| 370002 | For District K Extra over for each additional Test Location of SACP System to be inspected and maintained as specified in Clause 51.02(3) of the Particular Specification Section 51. |
| 371001 | For District L Inspection and Maintenance of Sacrificial Anode Cathodic Protection (SACP) System as specified in Particular Specification Section 51. |
| 371002 | For District L Extra over for each additional Test Location of SACP System to be inspected and maintained as specified in Clause 51.02(3) of the Particular Specification Section 51. |